Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para -
me ters, test conditions and
processing information only
to be used together with the
'Definitions' section in the
cat -
alogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays SCHRACK
2
Power PCB Relay RT2 (Continued)
PCB layout / terminal assignment
Bottom view on solder pins
2 CO contacts
2 NO contacts
S0418-CA
S0163-BJ
S0163-BK
*) With the recommended PCB hole sizes a grid
pattern from 2.5 mm to 2.54 mm can be used.
Coil versions, DC-coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC cmW
005 5 3.5 0.5 62+10% 403
006 6 4.2 0.6 90+10% 400
012 12 8.4 1.2 360+10% 400
024 24 16.8 2.4 1440+10% 400
048 48 33.6 4.8 5520+10% 417
060 60 42.0 6.0 8570+12% 420
110 110 77.0 11.0 28800+12% 420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Coil versions, AC-coil 50Hz
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
50 Hz 50 Hz 50 Hz
VAC VAC VAC cVA
524 24 18.0 3.6 350+10% 0.76
615 115 86.3 17.3 8100+15% 0.76
620 120 90.0 18.0 8800+15% 0.75
700 200 150.0 30.0 24350+15% 0.76
730 230 172.5 34.5 32500+15% 0.74
All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
Dielectric strength coil-contact circuit 5000 Vrms
open contact circuit 1000 Vrms
adjacent contact circuits 2500 Vrms
Clearance / creepage coil-contact circuit W10 / 10 mm
adjacent contact circuits W3 / 4 mm
Material group of insulation parts IIIa
Tracking index of relay base PTI 250 V
Insulation to IEC 60664-1
Type of insulation coil-contact circuit reinforced
open contact circuit micro disconnection
adjacent contact circuits basic
Rated insulation voltage 250 V
Pollution degree 3 2
Rated voltage system 240 V 230 / 400 V
Overvoltage category III
Other data
Mechanical endurance DC coil > 30 x 106cycles
AC coil > 5 x 106cycles
Material
RoHS - Directive 2002/95/EC compliant as per product date code 0413
Resistance to heat and fire, WG version according EN60335, par30.
Environment
Ambient temperature range -40...+85°C
max. ambient temperature AC coil 70°C
max. ambient temperature AgSnO contacts 70°C
Vibration resistance (function) NO / NC contact 20 / 5 g, 30 ... 300 Hz
Shock resistance (destruction) 100 g
Category of protection RTII - flux proof, RTIII - wash tight
Procesing
Mounting pcb or on socket
Mounting distance DC / AC coil W 0 / W 2.5 mm
Resistance to soldering heat flux-proof version 270°C / 10 s
wash-tight version 260°C / 5 s
Relay weight 13 g
Packaging unit 20 / 500 pcs
Accessories
For details see datasheet accessories RT