Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
1
1
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
1
Features
 Up or Down Frequency Mixer
 Low Conversion Loss: 11 dB
 2xLO & 3xLO Rejection: 50 dB
 RF Frequency: 14 - 32 GHz
 LO Frequency: 4 - 20 GHz
 IF Frequency: DC - 7 GHz
 Lead-Free 1.5x1.2 mm 6-lead TDFN Package
 Halogen-Free “Green” Mold Compound
 RoHS* Complaint and 260oC Reflow
Description
The MAMX-011009 is a lead-free 1.5 x 1.2 mm
TDFN surface mount plastic packaged sub-harmonic
mixer. No bias is required, although DC-offset on the
IF port can improve performance.
The MAMX-011009 can be used for up or down
frequency conversion. The mixer integrates an 180o
balanced diode topology that allows the LO to be
injected at ½ the mixing LO frequency. This
improves LO isolation and simplifies system
requirements.
When used as a down converting mixer, it can
convert RF port signals from 14 to 32 GHz to IF port
signals of DC to 7 GHz.
When used as an up converting mixer, it can convert
IF port signals from DC to 7 GHz to RF port signals
of 14 to 32 GHz.
In either mode the +15 dBm LO signal of 4 to 20
GHz drives the frequency conversion at ½ the
mixing product. Typical conversion loss is 11 dB
with 2xLO and 3xLO isolation typically greater than
50 dB. Typical input IP3 is greater than +12 dBm. Ordering Information3,4
Part Number Package
MAMX-011009-TR1000 1000 piece reel
MAMX-011009-001SMB Sample Board
MAMX-011009 bulk
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
Functional Schematic
Pin Configuration1
3. Reference Application Note M513 for reel size information.
4. All sample boards include 5 loose parts.
Pin No. Pin Name Description
1 RF Mixer RF port
2 N/C No Connection
3 IF Mixer IF port
4 N/C No Connection
5 N/C No Connection
6 LO Mixer LO port
7 Paddle2 Primary Ground
1. M/A-COM Technology Solutions recommends connecting
unused package pins to ground.
2. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
2
2
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
2
Electrical Specifications: IF Freq. = 2 GHz, LO Drive = +15 dBm ,TA = 25°C, Z0 = 50
Unless otherwise noted all measurement are as an up converter.
Absolute Maximum Ratings6,7
Parameter Absolute Maximum
Input Power +25 dBm
Junction Temperature8 +150°C
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM Technology Solutions does not recommend
sustained operation near these survivability limits.
8. Operating at nominal conditions with TJ +150°C will ensure
MTTF > 1 x 106 hours.
Parameter Test Conditions Units Min. Typ. Max.
Frequency
RF
IF
LO
GHz —
24
2
11
RF Return Loss 16 - 30 GHz dB 8
IF Return Loss DC - 7 GHz dB 10
Down Conversion Loss
16 GHz
24 GHz
32 GHz
dB —
13
11
12
Up Conversion Loss
16 GHz
24 GHz
32 GHz
dB —
12
10
11
11
Input IP3 Down Conversion
Up Conversion dB — +12
+14
Down Conversion Isolation
LO to IF
2LO to IF
3LO to IF
RF to IF
dB —
30
55
50
18
Up Conversion Isolation
LO to RF5
2LO to RF5
3LO to RF
IF to RF
dB
18
48
25
50
40
35
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
Class 1A (HBM) devices.
5. Measured at 24 GHz RF.
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
3
3
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
3
Application Schematic
Parts List
Part Value Case Style
R1 - R3 0 0201
PCB Layout
PCB Footprint Application Information
The MAMX-011009 is designed to be economical
and easy to use. By employing a sub-harmonic
topology, the user only has to deal with one high
frequency port (RF). This simplifies system design,
lowers cost, and combined with an ultra-small
plastic package delivers a superior system solution.
The MAMX-011009 design allows bi-direction
frequency conversion (IF to RF or RF to IF). The
conversion loss, isolation, and linearity are similar
either way.
For proper up or down frequency mixing the
MAMX-011009 must be driven with sufficient power
to activate the mixing diodes, typically 14 dBm or
higher. We highly recommend M/A-COM
Technology Solutions MAAM-011101, which has
been engineered to match the LO requirements of
the MAMX-011009.
Grounding
The printed circuit board (PCB) layout is simple for
the MAMX-011009 since no external components
are needed. The LO port is internally DC blocked;
DC voltages up to 20 V are acceptable. However,
proper grounding must be used for operation. It is
recommended that the total common ground
inductance not exceed 0.03 nH. This is equivalent
to placing a least four 8-mil (200 μm) diameter vias
under the device, assuming an 8-mil (200 μm) thick
RF layer to ground. More ground vias are recom-
mended if possible.
Up Conversion Summary
0
10
20
30
40
0
20
40
60
80
14 18 22 26 30
Conversion Loss
Input IP3
IF to RF Isolation
2xLO to RF Isolation
3xLO to RF Isolation
RF Frequency (GHz)
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
4
4
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
4
Typical Performance Curves for Down Conversion: TA = 25°C, RF = -10 dBm, LO = 15 dBm,
LO = 1/2x (RF+IF) GHz, IF = 2 GHz, ZRF=ZLO=ZIF = 50 , unless noted
Isolation
Conversion Gain vs. RF Frequency Input IP3 vs. RF Frequency (LO = +16 dBm)
LO Leakage
Conversion Gain vs. IF Frequency
Input IP3 vs. LO Drive Level
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
-50
-40
-30
-20
-10
0
14 16 18 20 22 24 26 28 30 32
LO
2xLO
3xLO
RF Frequency (GHz)
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
12 dBm
14 dBm
16 dBm
RF Frequency (GHz)
0
20
40
60
80
14 16 18 20 22 24 26 28 30 32
RF to IF
LO to IF
2xLO to I F
3xLO to I F
RF Frequency (GHz)
-20
-15
-10
-5
0
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
-20
-15
-10
-5
0
02468
16 GHz
24 GHz
32 GHz
IF Frequency (GHz)
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
5
5
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
5
Isolation
Conversion Gain vs. RF Frequency Input IP3 vs. RF Frequency (LO = +16 dBm)
LO Leakage
Conversion Gain vs. IF Frequency
Input IP3 vs. LO Drive Level
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
-50
-40
-30
-20
-10
0
14 16 18 20 22 24 26 28 30 32
LO
2xLO
3xLO
RF Frequency (GHz)
0
5
10
15
20
14 16 18 20 22 24 26 28 30 32
12 dBm
14 dBm
16 dBm
RF Frequency (GHz)
Typical Performance Curves for Up Conversion: TA = 25°C, IF = -10 dBm, LO = 15 dBm,
LO = 1/2x (RF+IF) GHz, IF = 2 GHz, ZRF=ZLO=ZIF = 50 , unless noted
-20
-15
-10
-5
0
02468
16 GHz
24 GHz
32 GHz
IF Frequency (GHz)
-20
-15
-10
-5
0
14 16 18 20 22 24 26 28 30 32
+25°C
-40°C
+85°C
RF Frequency (GHz)
0
15
30
45
60
14 16 18 20 22 24 26 28 30 32
IF to RF
LO to RF
2xLO to RF
3xLO to RF
RF Frequency (GHz)
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
6
6
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
6
RF Return Loss
Down Conversion Gain vs. LO Drive Down Conversion Input IP3 vs. LO drive
Up conversion Gain vs. LO Drive
IF Return Loss
Up Conversion Input IP3 vs. LO Drive
0
5
10
15
20
25
11 12 13 14 15 16 17
14 GHz
24 GHz
32 GHz
LO Power (dBm)
0
5
10
15
20
25
11 12 13 14 15 16 17
14 GHz
24 GHz
32 GHz
LO Power (dBm)
-12
-10
-8
-6
-4
-2
0
0 8 16 24 32
Frequency (GHz)
-16
-12
-8
-4
0
0 8 16 24 32
Frequency (GHz)
Typical Performance Curves:
-20
-16
-12
-8
-4
0
11 12 13 14 15 16 17
14 GHz
24 GHz
32 GHz
LO Power (dBm)
-20
-16
-12
-8
-4
0
11 12 13 14 15 16 17
14 GHz
24 GHz
32 GHz
LO Power (dBm)
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
7
7
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
7
Reference Application Note S2083 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is 100% matte tin over copper.
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN
NOTES:
1. REFERENCE JEDEC MO-153-AB FOR ADDITIONAL DIMENSIONAL AND
TOLERANCE INFORMATION.
2. ALL DIMENSIONS SHOWN AS INCHES/MM.
Sub-Harmonic Pumped Mixer
14 - 32 GHz
Rev. V1
MAMX-011009
8
8
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macomtech.com for additional data sheets and product information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
8
Applications Section
System usage of this Mixer
The MAMX-011009 is designed to be a building
block for more complex systems. The LO buffer
amplifier is deliberately left separate so as to
increase flexibility. If the LO buffer is desired, we
recommend the MAAM-011101 4-20 GHz amplifier
from M/A-COM Technology Solutions.
Typical usage of this mixer includes:
Feedback systems:
The low cost and simple use of the MAMX-011009
allows a low cost down-conversion feedback
system for pre-distortion or phase lock systems.
Combined with the M/A-COM Technology
Solutions MAAM-011101 for LO drive and printed
PCB couplers and the system is complete.
Single Balanced Application:
The MAMX-011009 has only one high frequency
port, so signal routing is simplified.
Double Balanced Image Rejection:
Combine two ultra-small MAMX-011009 mixers
with 90o (Lange) or 180o splitters for image
rejection.
I/Q Modulation:
I/Q quadrature drive two MAMX-011009 mixers into
a summer or 90o (Lange) for a direct conversion
system.