NC1V Circuit Protectors IDEC's original Spring-up Terminals and Cover Provide IP20 Finger-safe Protection. 35.0 mm 52.5 mm 78.8 mm 17.5 mm (1-pole) Auxiliary/alarm contact terminals are equipped with terminal covers. (2-pole) Finger-safe, spring-up terminals reduce wiring time. Ring terminal tabs can be installed easily, and screws are held secure. (3-pole) Retractable Actuator The actuator retracts when the circuit protector turns on. Inadvertent operation, due to touching the actuator, is prevented. Status of the circuit protector can easily be confirmed by viewing the position of the actuator. Retractable Actuator ON OFF Slim Housing Saves Space Main Circuit Terminals are Fingersafe (IP20) Spring-up, fingersafe structure requires no terminal cover. 1-pole 2-pole 3-pole 17.5mm Wide 35.0mm Wide 52.5mm Wide Auxiliary/Alarm Contact Terminals are Equipped with a Terminal Cover Voltage coil terminals on the relay trip version are also equipped with a terminal cover as standard. 2 Auxiliary/Alarm Contact, and Relay Trip Voltage Coil Terminals are Equipped with a Terminal Cover. 35mm-wide DIN Rail Mounting or Direct Panel Mounting Conforms to various international standards After tripping, the retractable actuator is in the middle position. Circuit protector must be turned off before it can be reset. Distinguishing Characteristics Wide variety of rated currents and tripping curves. One and 2-pole models are AC/DC compatible and allow for a reduction in inventory. Rated Short-circuit Capacity 2500A Available with Inertia Delay Allows for use with large inrush currents such as motors and lamps. ON OFF Tripped Safe Trip-free Mechanism The circuit remains open even when the operator is turned on after tripping (unit must be manually reset after removing the cause of the tripping). Available with Auxiliary or Alarm Contacts Auxiliary or Alarm Contact (Shown without terminal cover.) 3 NC1V Circuit Protectors IDEC's original spring-up, fingersafe terminals enhance reliability and safety. * Integrated electric shock protection structure (IP20). * Auxiliary/alarm contact terminals and voltage coil terminals on the relay trip types are equipped with terminal covers. * Spring-up, fingersafe terminals reduce wiring time. * Ring terminals can be installed. Captive terminal screws. * Available with inertia delay * Available with auxiliary or alarm contacts * Rated short-circuit capacity: 2500A * Slim, space-saving housing 1-pole: 17.5mm wide 2-pole: 35.0mm wide 3-pole: 52.5mm wide * Retractable actuator * The trip-free mechanism maintains the circuit open even when the operator is turned on after tripping. Applicable Standards Certification Mark Certification Organization (File No.) UL1077 E68029 CSA C22.2 No. 235 LR83454 B07 09 13332 063 EN60934 European Commission's Low Voltage Directive No. 2008010307265840 GB17701-1999 Electrical Applicance and Material Safety Law Technical Standard Series Trip JET Relay Trip Note: TUV, CE, and CCC marks are applicable for series trip type only. Specifications Operator Style Retractable actuator Internal Circuit Protection Method No. of Poles Rated Voltage (AC/DC) (Note 1) Rated Short-circuit Capacity Series Trip Rated Current (Current Trip) Operation Characteristics (Note 2) Rated Current Relay Trip (Voltage Trip) (Note 3) Trip Voltage Series trip (current trip), Relay trip (voltage trip) Hydraulic magnetic tripping system, Magnetic tripping system (voltage trip) 1-pole 2-pole 3-pole 250V AC 50/60Hz, 65V DC 250V AC 50/60Hz, 125V DC 250V AC, 50/60Hz 250V AC, 2500A 250V AC, 2500A 250V AC, 2500A 65V DC, 2500A 125V DC, 2500A 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A, 15A, 20A, 25A, 30A Time delay curve curve M (slow), curve A (medium), S (instantaneous) Curves M and A are avilable with inertia delay. 30A 24 to 48V DC (at 25C) Voltage application duration 10 sec maximum, tripping time 0.1 sec maximum (at rated voltage) 125V AC 3A (resistive load), 30V DC 2A (resistive load) 24V DC 1mA (resistive load, reference value) 100 M minimum (500V DC megger) 2000V AC, 1 minute (between terminals when main contacts are open, between live parts of different poles, between live and dead parts) 600V AC (between terminals when auxiliary circuits are open) Damage limits: 147 m/s2 (10 to 55 Hz) (1-pole, 2-pole), 78 m/s2 (3-pole) Operating extremes: 98 m/s2 (1-pole, 2-pole), 78 m/s2 (3-pole) Auxiliary Contact/ Alarm Contact Contact Rating Minimum Applicable Load Insulation Resistance Dielectric Strength Vibration Resistance (with rated current applied) Shock Resistance (S time delay curve: 80% rated current, A, M time delay curve: 100% rated current) Electrical Life Reference Temperature Operating Tempperature Operating Humidity Main Circuit Terminal Terminal Style Auxiliary/Alarm Contacts, Voltage Coil Terminal Weight (approx.) Damage limits: 490 m/s2 (1-pole, 2-pole), 297 m/s2 (3-pole) Operating extremes: 196 m/s2 (S, A, M types) 10,000 cyles minimum (at rated curent), 10 operations per minute 40C -10 to +60C (no freezing) Rated current is based on an ambient temperature of 40C. When the operating temperature exceeds 40C, derate the rated current by using the factors shown below. 45 to 85% RH (no condensation) Spring-up, fingersafe terminal: M4 screw (up to 20A), M5 screw (25A and 30A) M3.5 screw 1-pole: 90g, 2-pole: 170g, 3-pole: 260g Note 1: 3-pole type is for AC voltage only. Note 2: For S (instantaneous) tripping curve, humming sound may be caused when used in an AC sinusoidal-wave current circuit around 80% of the rated current, however, the performance of the circuit protector will not be affected. To avoid unnecessary tripping, do not use in circuits where inrush currents may be present. Note 3: Relay trip (voltage trip) type is not equipped with an overcurrent trip function. * Do not use the NC1V circuit protectors in environments where they are exposed to extreme temperature, humidity, dust, corrosive gases, vibration, shock, or in a circuit where inrush current may be present, otherwise unnecessary operations and damage may occur. 4 Operating Temp. Derating Factor 50C 0.9 55C 0.8 60C 0.7 NC1V Circuit Protectors Type No. Development NC1V - 2 1 00 F - 30A A DC24V 1 Type NC1V: Flap actuator type DIN rail and panel mounting 2 No. of Poles 1: 1-pole 2: 2-pole 3: 3-pole 3 Internal Circuit 1: Series trip (current trip) 5: Relay trip (voltage trip) Types 4 Auxiliary/Alarm Contacts 00: None 11: With one auxiliary contact 12: With two auxiliary contacts 13: With three auxiliary contacts 21: With one alarm contact 31: With one auxiliary contact and one alarm contact 32: With two auxiliary contacts and one alarm contact 8 Voltage Trip Coil Voltage DC24V: 24-48V DC Specified for relay trip only. 7 Time Delay Curve M: Slow A: Medium S: Instantaneous For both AC/DC. Specified for series trip only. 6 Rated Current 0.1A, 0.3A, 0.5A, 1A, 2A, 3A, 5A, 7A, 10A 15A, 20A, 25A, 30A Specified for series trip only. 5 Inertia Delay Blank: Without F: With Inertia delay is for AC voltage only. Available with medium and slow types (not applicable with relay trip). * Specity rated current, time delay curve, or voltage trip coil voltage in place of 6 7 8 in the Ordering Type No. Internal Circuit No. of Poles Inertia Delay Auxiliary Contact Alarm Contact -- - Code Ordering Type No. Applicable Standards 6 Rated 7 Time Delay Current Curve 0.1A 0.3A 0.5A 1A 2A 3A 5A 7A 10A 15A 20A 25A 30A M (slow) A (medium) S (instantaneous) -- -- -- DC24V 8 Voltage Trip Coil Voltage NC1V-1100- 6 7 One Auxiliary Contact NC1V-1111- 6 7 One Alarm Contact NC1V-1121 6 7 1-pole -- With NC1V-1111F- 6 7 One Alarm Contact NC1V-1121F- 6 7 -- -- 2-pole Series Trip (Current Trip) NC1V-2111- 6 7 Two Auxiliary Contacts NC1V-2112- 6 7 One Alarm Contact NC1V-2121- 6 7 One Auxiliary Contact and One Alarm Contact NC1V-2131- 6 7 NC1V-2111F- 6 7 Two Auxiliary Contacts NC1V-2112F- 6 7 One Alarm Contact NC1V-2121F- 6 7 One Auxiliary Contact and One Alarm Contact NC1V-2131F- 6 7 NC1V-3111- 6 7 Two Auxiliary Contacts NC1V-3112- 6 7 Three Auxiliary Contacts NC1V-3113- 6 7 One Alarm Contact NC1V-3121- 6 7 -- With 3-pole NC1V-3132- 6 7 NC1V-3100F- 6 7 NC1V-3111F- 6 7 Two Auxiliary Contacts NC1V-3112F- 6 7 Three Auxiliary Contacts NC1V-3113F- 6 7 One Alarm Contact NC1V-3121F- 6 7 1-pole 2-pole NC1V-3131- 6 7 One Auxiliary Contact One Auxiliary Contact and One Alarm Contact Two Auxiliary Contacts and One Alarm Contact Relay Trip (Voltage Trip) NC1V-3100- 6 7 One Auxiliary Contact One Auxiliary Contact and One Alarm Contact Two Auxiliary Contacts and One Alarm Contact 3-pole NC1V-2100F- 6 7 One Auxiliary Contact -- -- NC1V-2100- 6 7 One Auxiliary Contact -- With NC1V-1100F- 6 7 One Auxiliary Contact NC1V-3131F- 6 7 NC1V-3132F- 6 7 NC1V-1500- 8 -- -- NC1V-2500- 8 NC1V-3500- 8 Note: Inertia delay is for AC circuit. Also, time delay curve of S (instantaneous) is not available with inertia delay. 5 NC1V Circuit Protectors Internal Circuit * 1-pole NC1V-1100 (Without auxiliary/alarm contacts) NC1V-1111 (With auxiliary contact) LINE NC1V-1121 (With alarm contact) One auxiliary contact. LINE NC1V-1500 (Relay Trip) One alarm contact. LINE A B C LOAD N O C LOAD C N C LOAD N O D N C * 2-pole NC1V-2100 (Without auxiliary/alarm contacts) LINE LINE LOAD LOAD NC1V-2111 (With auxiliary contact) NC1V-2121 (With alarm contact) One auxiliary contact. Also available with two LINE auxiliary contacts. LINE LOAD LOAD C N O N C LINE LOAD NC1V-2500 (Relay Trip) One alarm contact. Also available with one LINE auxiliary contact and one alarm contact. LOAD C N O A N C A B B C C D D Note: Those with two auxiliary contacts and with one auxiliary contact and one alarm contact have been applied for UL and CCC. * 3-pole NC1V-3100 (Without auxiliary/alarm contacts) NC1V-3111 (With auxiliary contact) NC1V-3121 (With alarm contact) One auxiliary contact. Also available with two or three auxiliary contacts. LINE LOAD LINE LINE LOAD LOAD LINE LOAD LINE One alarm contact. Also available with one auxiliary and one alarm contacts, and two auxiliary and one alarm contacts. LINE LINE LOAD LOAD C N O NC1V-3500 (Relay Trip) N C LINE LOAD LINE LOAD LOAD C N O N C A A A B B B C C C D D D Note: Those with two or three auxiliary contacts, with one auxiliary contact and one alarm contact, and with two auxiliary contacts and one alarm contacts have been applied for UL and CCC. Overcurrent-Time Delay Characteristics (sec at 40C) [vertical mounting] Item 125% 150% Percent of Rated Current 175% 200% 400% 600% 800% 1000% NO TRIP -- 0.005 to 0.1 0.003 to 0.06 0.0027 to 0.05 0.002 to 0.03 0.002 to 0.028 0.002 to 0.025 0.002 to 0.022 NO TRIP 25 to 240 16 to 140 -- 6 to 32 0.4 to 4 0.0055 to 1.5 0.004 to 0.8 0.004 to 0.65 M (slow) NO TRIP 60 to 600 30 to 200 -- 9 to 60 0.4 to 10 0.006 to 4.5 0.004 to 1.8 0.004 to 0.8 With Inertia Delay A (medium) NO TRIP 25 to 240 -- -- 6 to 32 0.8 to 6 0.09 to 3.5 0.02 to 1.8 0.01 to 1.0 With Inertia Delay M (slow) NO TRIP 60 to 600 -- -- 10 to 60 0.8 to 10 0.06 to 4.5 0.02 to 3 0.01 to 1.75 Time Delay Curve S (instantaneous) AC (50/60 Hz)/DC A (medium) AC (50/60 Hz) : MAY TRIP on DC 6 100% NC1V Circuit Protectors Time Delay Curves at 40C 1000 1000 DC (Note) DC (Note) Curve A (medium) AC 100 Time in sec Time in sec 10 1 10 1 0.1 0.1 0.01 0.01 100 200 300 400 500 600 700 800 900 Curve M (slow) AC 100 1000 100 125 200 300 400 500 600 700 800 900 1000 125 Current (percent load of the rated current) Current (percent load of the rated current) 1000 Curve S (instantaneous) DC (Note) Note: The entire shaded area applies to AC. For DC, the shaded area on the right of the dashed line applies. 100 Time in sec 10 1 AC 0.1 0.01 100 200 300 400 500 600 700 800 900 1000 125 Current (percent load of the rated current) 1000 Curve A (medium) With Inertia Delay 100 Curve M (slow) With Inertia Delay 100 10 10 Time in sec Time in sec 1000 1 1 0.1 0.1 0.01 0.01 100 200 300 400 500 600 700 800 900 125 Current (percent load of the rated current) 1000 100 200 300 400 500 600 700 800 900 1000 125 Current (percent load of the rated current) 7 NC1V Circuit Protectors Time Delay Curve and Ambient Temperature Inertia Delay NC1V circuit protectors employ an electromagnetic tripping system, where the rated current (trip current) is not affected by ambient temperatures. But the time delay may vary with the oil viscosity in the oil dash pot. Lower oil viscosity at higher temperatures results in a shorter delay, whereas at lower temperatures the delay will be longer. Inertia delay is designed not to trip on a non-repeating single pulse of 20 times the rated current (peak value) for a duration of 8 ms. In addition, circuit protectors equipped with inertia delay do not respond to high inrush currents caused by transformer or lamp loads, but perform the specified interruption on the subsequent overcurrents. Inertia delay is available on AC circuits, and is not available with the series trip curve S (instantaneous). Temperature Correction Curve 12000 The time delay curves on the preceding page are measured at 40C. With reference to the following curves, time delays can be corrected according to ambient temperature. 400 Change of Time Delay (%) 10000 Percent of Rated Current (%) 600 500 300 200 100 80 60 1. Percent of rated current Pulse peak current x100 Protector rated current 2. Sinusoidal or parabolic pulse Pulse peak current 8000 Pulse width (Duration) 6000 4000 40 -20 -10 0 10 20 40 30 50 60 70 2000 Ambient Temperature (C) The time delay is based on an ambient temperature of 40C. Time delays at other temperatures are corrected according to the temperature correction curve. The time delay of the instantaneous time delay curve (S) is not affected by the ambient temperature. When operating temperature exceeds 40C, derate the rated current by multiplying the derating factor shown on the right. Operating Temp. Derating Factor 50C 55C 60C 0.9 0.8 0.7 Rated Current 0.1A 0.3A 0.5A 1A 2A 3A 5A 7A 10A 15A 20A 25A 30A For AC 50/60 Hz Impedance () Curve S Curves A, M 66.0 116.0 6.6 11.0 1.92 3.65 0.50 0.93 0.16 0.27 0.07 0.12 0.025 0.050 0.014 0.027 0.007 0.021 0.006 0.010 0.005 0.006 0.004 0.005 0.003 0.004 at 25C For DC Resistance () Curve S Curves A, M 43.0 106.0 4.1 10.0 0.86 3.40 0.25 0.90 0.11 0.25 0.050 0.11 0.015 0.045 0.011 0.025 0.005 0.020 0.005 0.009 0.004 0.005 0.004 0.005 0.003 0.004 Tolerance: 25% (up to 20A), 50% (25A and 30A) * Relay Trip (Voltage Trip) Tripping Voltage 24-48V 100.0 Tolerance: 25% 8 at 25C For DC Resistance () 2 3 4 5 6 7 8 9 10 Pulse Width (ms) Voltage Drop Due to Coil Resistance or Impedance Impedance and Coil Resistance * Series Trip (Current Trip) 1 The internal resistance or impedance of a circuit protector tends to be larger for a smaller rated current. Therefore, when circuit protectors of a small rated current are used, voltage drop should be taken into consideration. Internal resistance also varies with time delay curves, which should also be considered during installation. NC1V Circuit Protectors Dimensions * 1-pole All dimensions in mm. DIN Rail (BNDN1000) M4 Terminal Screw (up to 20A) M5 Terminal Screw (25A or more) 6.6 66.0 48.3 ON 78.8 72.5 44.0 NC1V-1100 71.4 56.0 12.0 2-o4.5 Holes (for screw mounting) 5.0 33.0 17.5 DIN Rail (BNDN1000) M4 Terminal Screw (up to 20A) M5 Terminal Screw (25A or more) 12.0 6.6 66.0 48.3 Mounting Hole Layout (M4 Mounting Screws) 12 NC1V-1111 71.4 78.8 ON 48.4 72.5 NC1V-1121 (Alarm Contact) 71.4 56.0 (Auxiliary Contact) 2-M M3.5 Terminal Screw 4 2-o4.5 Holes (for screw mounting) 17.5 5.0 33.0 Terminal Cover DIN Rail (BNDN1000) 6.6 12.0 66.0 48.3 M5 Terminal Screw (30A) 78.8 ON 48.4 72.5 (Relay Trip) 71.4 56.0 NC1V-1500 M3.5 Terminal Screw 2-o4.5 Holes (for screw mounting) 17.5 5.0 33.0 Terminal Cover * 2-pole DIN Rail (BNDN1000) M4 Terminal Srew (up to 20A) M5 Terminal Screw (25A or more) 6.6 Mounting Hole Layout (M4 Mounting Screws) 29.5 71.4 78.8 44.0 ON 66.0 48.3 72.5 NC1V-2100 71.4 56.0 29.5 2-M 4 2-o4.5 Holes (for screw mounting) 35.0 5.0 33.0 9 NC1V Circuit Protectors * 2-pole DIN Rail (BNDN1000) M4 Terminal Screw (up to 20A) M5 Terminal Screw (25A or more) 6.6 78.8 48.4 ON 66.0 48.3 72.5 71.4 NC1V-2111 (one auxiliary contact) NC1V-2112 (two auxiliary contacts) NC1V-2121 (one alarm contact) NC1V-2131 (one auxiliary contact and one alarm contact) 56.0 29.5 Mounting Hole Layout (M4 Mounting Screws) M3.5 Terminal Screw 2-o4.5 Holes (for screw mounting) 35.0 5.0 33.0 Terminal Cover 29.5 The dimensions are for NC1V-2111 and NC1V-2121. DIN Rail (BNDN1000) 66.0 71.4 6.6 29.5 48.3 M5 Terminal Screws (30A) 2-M ON 78.8 72.5 48.4 56.0 NC1V-2500 (Relay Trip) 71.4 4 M3.5 Terminal Screw 2-o4.5 Holes (for screw mounting) 35.0 5.0 33.0 Terminal Cover * 3-pole DIN Rail (BNDN1000) 47.0 M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) 6.6 66.0 48.3 ON 78.8 72.5 44.0 71.4 56.0 NC1V-3100 Mounting Hole Layout (M4 Mounting Screws) 47.0 2-o4.5 Holes (for screw mounting) 52.5 DIN Rail (BNDN1000) M4 Terminal Screw (up to 20A) M5 Terminal Srew (25A or more) 6.6 M3.5 Terminal Srew 2-o4.5 Holes (for screw mounting) Terminal Cover The dimensions are for NC1V-3111 and NC1V-3121. 10 4 48.3 78.8 ON 52.5 2-M 66.0 72.5 48.4 56.0 47.0 71.4 NC1V-3111 (one auxiliary contact) NC1V-3112 (two auxiliary contacts) NC1V-3113 (three auxiliary contacts) NC1V-3121 (one alarm Contact) NC1V-3131 (one auxiliary contact and one alarm contact) NC1V-3132 (two auxiliary contacts and one alarm contact) 71.4 5.0 33.0 5.0 33.0 NC1V Circuit Protectors * 3-pole All dimensions in mm. DIN Rail (BNDN1000) 47.0 6.6 Mounting Hole Layout (M4 Mounting Screws) 66.0 48.3 71.4 78.8 ON 48.4 47.0 72.5 71.4 NC1V-3500 (Relay Trip) 56.0 M5 Terminal Screw (30A) 2-M 4 M3.5 Terminal Screw 2-o4.5 Holes (for screw mounting) 52.5 5.0 33.0 Terminal Cover Instructions * Applicable Wire and Crimp Terminal Tripping method is hydraulic magnetic. Minimum operating current varies with installation angle. Operating currents are influenced by the weight of movable iron core. With reference to the following figures, correct the rated current. Auxiliary Contact Alarm Contact Voltage Coil Terminals 100% Terminal Main Circuit Terminals * Installation Angle 120% 90% Terminal Screw Spring-up, fingersafe, slotted Phillips screw with square washer (up to 20A) Spring-up fingersafe terminal (25A and 30A) Connectable Wire Size (mm2) Applicable Crimping Terminal 0.25 to 1.65 R1.25-4 1.04 to 2.63 R2-4 2.63 to 6.64 R5.5-4 0.25 to 1.65 R1.25-5 1.04 to 2.63 R2-5 2.63 to 6.64 R5.5-5 0.25 to 1.65 R1.25-3.5 1.04 to 2.63 R2-3.5 Tightening Torque (N*m) Slotted Phillips screw with square washer 1 to 1.4 1.8 to 2.2 0.7 to 0.9 * For wiring the main circuit terminal, use the applicable crimp terminals and tighten to the recommended torque. * When using the NC1V circuit protector as CSA-certified product, use with CSAcertified crimp terminal. * When using the NC1V circuit protector as UL-listed product, use with UL-listed crimp terminal. Panel Mounting Screw (not supplied) 100% Srew Type Tightening Torque Shape Spring Washer M4 0.8 to 1.0 N*m Plain Washer Minimum operating current is calculated from the following formula: (Minimum operating current) = (Rated current) x (Correction factor by installation angle) x (Reference minimum tripping current rate) Product Markings (Example: NC1V-1111-30AA) PSE Certification Type No. Rated Voltage PS E 220VAC 30A I.C.2500A CIRCUIT PROTECTOR Rated Current * DIN Rails No. of Poles Time Delay Curve J E T NC1V-1111 POLE 1 Ue 250VAC 50/60Hz * 65VDC In 30A CURVE A Auxiliary/Alarm Contact Rating Suppl. Prot. Installing AUX. SW 125VAC 3A 30 VDC 2A A.T. 40C JAPAN LINE [Removal from DIN Rail] Using a flat screwdriver, pull the latch on the circuit protector to remove from the DIN rail. LOAD [Installation on DIN Rail] 1. Fasten the DIN rail securely. 2. With the latch facing downward, install the NC1V circuit protector on the DIN rail as shown below. Reference Operating Temperature Certification Marks Installation of Auxiliary/Alarm Terminal Cover After wiring the terminals, install the terminal cover by aligning with the circuit protector as shown below. Removing 35mm-wide DIN Rail 35mm-wide DIN Rail Push Flat Srcrewdriver Terminal cover installed Latch 11 NC1V Circuit Protectors Accessories * DIN Rail F 35mm-wide DIN Rails G H A K B H Overall length 39.4" (1000mm) Length Part No. Material BNDN1000 1000mm D C Aluminum * End Clip Part No. Applicable Rail Material Package Quantity BNDN1000 Galvanized Trivalent Chromate Treatment 10 BNL6 9mm wide * Auxiliary/Alarm Terminal Cover Type No. Material Package Quantity NC1V-AUX-CV Nylon (PA66) 1 * Miscellaneous Accessories (available 2009) Type No. Description NC9Z-MA11 Panel Cut-Out Mounting bracket for 1-pole mode NC9Z-MA21 Panel Cut-Out Mounting bracket for 2-pole model NC9Z-MA31 Panel Cut-Out Mounting bracket for 3-pole model NC9Z-TA1 Fast-On Tab terminal Adapter NC9Z-PW1 Marking Plate NC9Z-LK1 Lock-Out Bracket Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: products@idec.co.jp IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD. 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com Wendenstrasse 331, 20537 Hamburg, Germany Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 E-mail: service@idec.de IDEC CANADA LIMITED Room 608-609, 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 200001, PRC Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 E-mail: idec@cn.idec.com Units 11-15, Level 27, Tower 1, Millennium City 1, 388 Kwun Tong Road, Kwun Tong, Kowloon, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: info@hk.idec.com 3155 Pepper Mill Court, Unit 4, Mississauga, Ontario, L5L 4X7, Canada Tel: +1-905-890-8561, Toll Free: (888) 317-4332 Fax: +1-905-890-8562 E-mail: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. 2/3 Macro Court, Rowville, Victoria 3178, Australia Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Fax: +61-3-9763-3255 E-mail: sales@au.idec.com IDEC ELECTRONICS LIMITED www.idec.com Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: sales@uk.idec.com IDEC (SHANGHAI) CORPORATION IDEC (BEIJING) CORPORATION Room 211B, Tower B, The Grand Pacific Building, 8A Guanghua Road, Chaoyang District, Beijing 100026, PRC Tel: +86-10-6581-6131, Fax: +86-10-6581-5119 IDEC (SHENZHEN) CORPORATION Unit AB-3B2, Tian Xiang Building, Tian'an Cyber Park, Fu Tian District, Shenzhen, Guang Dong 518040, PRC Tel: +86-755-8356-2977, Fax: +86-755-8356-2944 IDEC TAIWAN CORPORATION 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@tw.idec.com IDEC IZUMI ASIA PTE. LTD. No. 31, Tannery Lane #05-01, HB Centre 2, Singapore 347788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com Cat. No. NC9Y-B100-0 PRINTED IN U.S.A. 5K 09/08