DC Series RFI Power Line Filters Line Filters for DC Applications UL Recognized* CSA Certified* TUV Approved* * Approvals pending Specifications Hipot rating (one minute): line-to-ground line-to-line Operating Voltage (max): Operating ambient temp. range: DC Series The DC series filters were designed as general purpose line filters for DC applications. They are available with or without circuit breakers for extra protection. They will also be available soon with feed-through capacitors for added performance (contact factory for more information). The DC series is designed to comply with UL 1283, CSA 22.2 No. 8 and EN60950. The DC series was developed in response to the increasing demand for DC filtering in the telecom-datacom market. These filters are generally used in central office equipment like switches, routers, and hubs to clean up the 48 VDC power, but are not exclusive to that equipment. They can also be used at the primary input of the DC power supply. Electrical Schematics Standard Performance Version Note 2 Note 3 2250VDC 1450VDC 80VDC -10oC to 55oC In an ambient, To, higher than 55oC, the maximum operating current, Io, is as follows: 85 - T Io = Ir Minimum insertion loss in dB:* Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .1 .15 .5 1 3 15A 1 12 20 41 45 61 30A 4 15 23 47 59 64 60A 9 17 29 40 59 100A 10 18 38 39 53 125A 1 12 20 41 45 61 Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .01 .05 .1 .15 .5 1 3 15A 7 22 27 30 30 36 56 30A 7 22 28 31 32 59 56 60A 15 30 36 40 40 35 60 100A 14 29 35 39 33 30 53 125A 7 22 27 30 30 36 56 o 30 5 63 56 50 50 63 10 47 44 39 35 47 30 39 36 34 21 39 5 49 51 51 53 49 10 38 41 39 41 38 30 31 28 32 30 31 * Contact factory for insertion loss data on high performance versions. Note 1 Note 1 High Performance Version Note 4 Note 2 Note 1 Note 1 Note 4 Resistor location for reference only. Note 1: Depicts style 6 terminals are redundant. Note 2: Depicts optional circuit breaker. Note 3: For 100 & 125A versions delete second coil. Note 4: Depicts style 10 terminal versions have seperate ground stud. www.cor.com - Libertyville, IL (847) 680-7400 Series DC Cutout Dimensions Terminations Style 6 (15, 30 & 60A) Supplied with #10-32 redundant studs - 0.625" spacing. Style 6 (100 & 125A) Supplied with 1/4-20 redundant studs - 0.75" spacing Style 10 (15 & 30A) Phoenix Contact P/N VDFK4 Accepts 12 AWG stranded wire Torque Spec: 5.5 - 7.0 in-lb. Ground Stud 8-32 Style 10 (60A) Phoenix Contact P/N HDFK 16-VP Accepts 6 AWG stranded wire Torque Spec: 17.7 - 21.2 in-lb. Ground Stud 10-32 Style 10 (100A) Phoenix Contact P/N HDFK 25-VP Accepts 4 AWG stranded wire Torque Spec: 35.4 - 39.9 in-lb. Ground Stud 1/4 - 20 Style 10 (125A) Phoenix Contact P/N HDFK 50-VP Accepts 1 AWG stranded wire Torque Spec: 35.4 - 39.9 in-lb. Ground Stud 1/4 - 20 Ordering Information Consult your local Corcom sales representative for pricing 60DCB6B Current Rating Options 15, 30, 60, 100, 125A Series Name D C - Series Name Mounting Style F - Flange Mounting B - Bulkhead and Rack Mounting B - Circuit Breaker F - Feedthru Capacitors for High Performance BF - Circuit Breaker and Feedthru Capacitors Termination Style 6 - Redundant Stud 10 - Phoenix Terminal Available Part Numbers 15DCF6 30DCF6 60DCF6 100DCF6 125DCF6 15DCF6B 30DCF6B 60DCF6B 15DCB6 30DCB6 60DCB6 100DCB6 125DCB6 15DCB6B 30DCB6B 60DCB6B 15DCB6F 30DCB6F 60DCB6F 100DCB6F 125DCB6F 15DCB6BF 30DCB6BF 60DCB6BF 15DCF10 30DCF10 60DCF10 100DCF10 125DCF10 15DCF10B 30DCF10B 60DCF10B 15DCB10 30DCB10 60DCB10 100DCB10 125DCB10 15DCB10B 30DCB10B 60DCB10B 15DCB10F 30DCB10F 60DCB10F 100DCB10F 125DCB10F 15DCB10BF 30DCB10BF 60DCB10BF Metric shown in italics. Part Number A B C D E F Fig. 15DCB6 1.375 34.93 1.249 31.72 3.472 88.19 15DCB6B 1.449 36.80 0.756 19.20 1.308 33.22 15DCB10 0.781 19.84 1.218 30.94 3.472 88.19 15DCB10B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.218 30.94 0.781 19.84 2 15DCF6B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.375 34.93 1.249 31.72 2 15DCF10B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.218 30.94 0.781 19.84 2 30DCB6 1.375 34.93 1.249 31.72 3.472 88.19 30DCB6B 1.449 36.80 0.756 19.20 1.308 33.22 30DCB10 0.781 19.84 1.218 30.94 3.472 88.19 30DCB10B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.218 30.94 0.781 19.84 2 30DCF6B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.375 34.93 1.249 31.72 2 30DCF10B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.218 30.94 0.781 19.84 2 60DCB6 1.375 34.93 1.249 31.72 3.472 88.19 60DCB6B 1.449 36.80 0.756 19.20 1.308 33.22 60DCB10 1.005 25.53 1.635 41.53 3.462 87.93 60DCB10B 1.449 36.80 0.756 19.20 1.308 33.22 3.462 87.93 1.005 25.53 1.635 41.53 2 60DCF6B 1.449 36.80 0.756 19.20 1.308 33.22 3.472 88.19 1.375 34.93 1.249 31.72 2 60DCF10B 1.449 36.80 0.756 19.20 1.308 33.22 3.462 87.93 1.005 25.53 1.635 41.53 2 100DCB6 1.700 43.18 1.549 39.34 3.221 81.81 1 100DCB10 1.281 32.54 2.000 50.80 2.244 57.00 1 125DCB6 1.700 43.18 1.549 39.34 3.221 81.81 1 125DCB10 1.562 39.67 2.188 55.58 2.180 55.37 1 1 3.472 88.19 1.375 34.93 1.249 31.72 1 1 3.472 88.19 1.375 34.93 1.249 31.72 1 3.472 88.19 1.375 34.93 1.249 31.72 2 1 Recommended Panel Cutouts Recommended Panel Cutouts Fig. 1 Fig. 2 Libertyville, IL (847) 680-7400 - www.cor.com 2 1 Contact factory for availability of 100 & 125 amp circuit breaker versions. Holes: .157 Dia.(4) 3.99 2 Holes: .157 Dia.(4) 3.99 DC Series Case Style Metric shown in italics. Fig. 7 Fig. 3 Tapped insert: 6-32 (4) Note: Delete circuit breaker for DCB10 models Tapped insert: 6-32 (4) Typical dimensions Mounting slots: .260 x .39 (4) 6.6 x 9.9 Fig. 4 Fig. 8 Typical dimensions Mounting holes: . 156 x .203 (4) 4.0 x 5.2 Fig. 5 Typical dimensions Mounting slots: .260 x .39 (4) 6.6 x 9.9 Note: 15DCF6 & 30DCF6 versions come with mounting holes in place of mounting slots. Fig. 9 Tapped insert: 6-32 (4) Typical dimensions Mounting slots: .260 x .39 (4) Tapped insert: 6-32 (4) 6.6 x 9.9 Note: Delete circuit breaker for DCB10 models Fig 6 Fig. 10 Tapped insert: 6-32 (4) Note: Delete circuit breaker for DCB6 models Tapped insert: 6-32 (4) Typical dimensions .260 x .39 Mounting slots: 6.6 x 9.9 (4) www.cor.com - Libertyville, IL (847) 680-7400 Case Style Metric shown in italics. Fig. 11 Typical dimensions Mounting slots: .260 x .39 (4) 6.6 x 9.9 Case Dimensions Metric shown in italics. Part Number A B C (max) (max) (max) D E (max) F Fig. 15DCB6 5.66 143.8 5.06 128.5 1.46 37.0 4.500 114.30 4.06 103.1 0.950 24.13 6 15DCB6B 7.82 198.6 5.06 128.5 1.46 37.0 4.500 114.30 6.06 153.9 0.950 24.13 6 15DCB10 4.88 123.8 5.06 128.5 1.46 37.0 4.500 114.30 4.06 103.1 0.950 24.13 3 15DCB10B 7.06 179.3 5.06 128.5 1.46 37.0 4.500 114.30 6.06 153.9 0.950 24.13 3 15DCF6 5.33 135.4 3.10 78.7 1.78 45.2 2.677 68.00 3.70 94.0 2.000 50.80 8 15DCF6B 7.69 195.3 5.06 128.5 1.46 37.0 5.740 145.80 6.06 153.9 3.520 89.41 7 15DCF10 4.60 116.8 3.10 78.7 1.78 45.2 2.677 68.0 3.70 94.0 2.000 50.80 4 15DCF10B 7.06 179.3 5.06 128.5 1.46 37.0 5.740 145.80 6.06 153.9 3.520 89.41 5 30DCB6 7.69 195.3 5.06 128.5 1.46 37.0 4.500 114.30 6.06 153.9 0.950 24.13 6 30DCB6B 8.69 220.7 5.06 128.5 1.46 37.0 4.500 114.30 7.06 179.3 0.950 24.13 6 30DCB10 6.88 174.6 5.06 128.5 1.46 37.0 4.500 114.30 6.06 153.9 0.950 24.13 3 30DCB10B 8.06 204.7 5.06 128.5 1.46 37.0 4.500 114.30 7.06 179.3 0.950 24.13 3 30DCF6 6.19 157.2 3.96 100.6 2.18 55.4 3.500 88.90 4.56 115.8 2.000 50.80 8 30DCF6B 8.69 220.7 5.00 127.0 1.46 37.0 5.740 145.80 7.06 179.3 4.520 114.81 7 30DCF10 5.95 151.1 3.96 100.6 2.18 55.4 3.500 88.90 4.56 115.8 2.000 50.80 4 30DCF10B 8.06 204.7 5.06 128.5 1.46 37.0 5.740 145.80 7.06 179.3 4.520 114.81 5 8.69 220.73 5.06 128.5 1.46 37.0 4.500 114.30 7.06 179.3 0.950 24.13 6 60DCB6B 10.69 271.5 5.06 128.5 1.46 37.0 4.500 114.30 9.06 230.1 0.950 24.13 6 60DCB10 9.75 247.7 5.06 128.5 1.46 37.0 4.500 114.30 7.06 179.3 0.950 24.13 9 60DCB10B 11.75 298.5 5.06 128.5 1.46 37.0 4.500 114.30 9.06 230.1 0.950 24.13 9 60DCF6 7.56 192.0 5.48 139.2 2.55 64.8 4.920 124.97 5.94 150.9 2.756 70.00 8 60DCF6B 10.69 271.5 5.06 128.5 1.46 37.0 5.740 145.80 9.06 230.1 6.520 165.61 7 60DCF10 8.50 215.9 5.48 139.2 2.55 64.8 4.920 124.97 5.94 150.9 2.576 65.43 11 60DCF10B 11.75 298.5 5.06 128.5 1.46 37.0 5.740 145.80 9.06 230.1 6.520 165.61 10 100DCB6, 125DCB6 10.31 261.9 5.06 128.5 1.78 45.2 4.500 114.30 8.06 204.7 0.950 24.13 6 100DCF6, 125DCF6 10.60 269.2 6.30 160.0 2.52 64.0 5.700 144.78 8.46 214.9 4.583 116.41 8 100DCB10 11.13 282.6 5.06 128.5 1.78 45.2 4.500 114.30 8.06 204.7 0.950 24.13 9 100DCF10 11.50 292.1 6.30 160.0 2.52 64.0 5.700 144.78 8.46 214.9 4.583 116.41 11 125DCB10 11.50 292.1 5.06 128.5 1.78 45.2 4.500 114.30 8.06 204.7 0.950 24.13 9 125DCF10 6.30 160.0 2.52 64.0 5.700 144.78 8.46 214.9 4.583 116.41 10 60DCB6 Libertyville, IL (847) 680-7400 - www.cor.com Series DC 11.75 298.5