Amphenol
162GB Series
Miniature Bayonet Lock Connectors
Amphenol
CONTENTS Pages
Introduction to 162GB Crimp Connectors 2
Audio Applications 2
Cable Assembly Facilities at Amphenol Ltd 2
MIL-C-26482 Qualification Approval Tests 3-4
DEF 5325 Qualification Approval Tests
Table of Shell Styles 5
Insert Availability and Voltage Ratings 6-7
How to Order 162GB Crimp Connectors 8
Box Mounting Receptacles 9-10
Single Hole Fixing Receptacles 11-12
Cable Mounting Receptacles 13-14
Plugs 15-16
Plugs with optional Coupling Rings 17-18
Cable Accessories 19
Cables to DEF 10 20
Accessories
Dust Caps 21-28
AIA Backshells Interconnection Accessories 29-31
Interconnection Accessories Installation Procedure 32-33
Interconnection Accessories Shield Term Process 34
Key/keyway Orientations 35
Insert Orientations 36
162GB Crimp Assembly Instructions 37-42
2
Development and manufacture of 162GB miniature
bayonet lock connectors has been closely
coordinated with the solder version. The entire
programme has been carried out at Amphenol’s
Whitstable Plant. The precision machinery and
measurement control processes used for the
production of 162GB crimp connectors are the same
as those used to produce 62GB solder connectors.
Full intermountability and intermateability are
absolutely guaranteed.
162GB Series crimp connectors share many of the
features of 62GB solder connectors. Coupling is
achieved with a triple-track bayonet locking system
which gives positive alignment on all shell sizes.
When connector halves are fully mated there is a
definite click. Inspection holes in the coupling ring
will then reveal the bayonet pins on the receptacle
which are clearly marked in yellow.
The Amphenol design means simplified removal of
coupling rings for servicing or replacement as they
are front demountable. In addition there is a rough
grip heavy duty style for arduous conditions and a
lever coupling ring which allows extremely close
mounting of connectors.
The method of sealing is the same as for 62GB
connectors; using peripheral seals on the rubber
inserts and sealing the mating shells with a square
section gasket. Wire sealing is by multiple risers in
the rear grommet.
Derating
Connectors must be derated under the following operating
temperatures:
1. At elevated temperatures, the current ratings are
reduced as show in the table on page 10.
2. At high altitudes, revised voltage ratings become
effective as shown on page 11.
3. When connectors to different specifications are
intermated (e.g. BS 9522-N001 and MIL-C-26482), the
combination must not be operated under conditions
more severe than the less stringent clause of either
specification.
Amphenol 162GB connectors are designed to meet the
most stringent requirements of both specifications.
Audio Applications
Contacts are suitable for tinsel cord applications.
Cable Assemblies
Amphenol is fully equipped to undertake the preparation of
all types of cable assemblies complying with the military
vehicles and engineering establishments and fighting
vehicles requirements of the Ministry of Defence the
Ministry of Environment (Motorways) for motorway control
equipment the Post Office manufacturing code and to the
British Standards Institute when applicable to Cable
systems. Control procedures carried out in accordance
with MIN DEF 05-21. Approval numbers BS 9000, 1043/M
and CAA AD/1450/58. Moulded terminations form a
specialised service by the company. The process offers
such advantages as a waterproof seal between cable and
connector back-end, mechanical protection, and a
homogeneous joint between moulding and cable.
Other Amphenol Products
Amphenol products include: printed circuit, rack and panel,
microminiature, audio; hermetic and R.F. connectors;
integrated circuit components; trimming and precision
potentiometers; concentric and digital microdials; cable,
cable assemblies; fans and blowers; relays and keys;
chokes and coils; R.F. coaxial switches.
Amphenol 162GB
Crimp Connectors
DESIGNED TO COMPLY WITH MIL-C-26482
AND BS 9522-N0001, THE SUCCESSOR TO
DEF 5326 Patt. 603
3
Tests Brief Description
Examination of Product
Maintenance Ageing Crimp only
There is no damage to the contacts or connectors after 10
removals and insertions of the contacts
Contact Insertion and Removal Forces Crimp only
Insertion does not exceed 66.7 N (15lbf.) For individual contacts.
Removal does not exceed 44.5N (10lbf.)
Crimp Contact
Contact locking mechanisms withstands the following minimum
axial forces:
CONTACT SIZE 20 16 12
FORCE (N) 89 111 133
FORCE (LBF) 20 25 30
Contact Retention
Axial displacement does not exceed 0.304mm (0.012in) when
pressure is applied from face side.
Operating Forces Torque measurement of mating and unmating.
Ranges from 0.905 Nm. (8 lbf. in.) on shell size 8 to 4.971 Nm. (44
lbf. in.) on shell size 24 couplings.
Insulation Resistance, Room Temperature Unmated connectors tested in accordance with Method 302 test
condition B of MIL-STD-202.
Dielectric Withstanding Voltage (Sea Level) Mated and unmated connectors tested in accordance with Method
301 of MIL-STD-202.
Dielectric Withstanding Voltage (Altitude) Tested in accordance with Method 105, test condition C of MIL-
STD-202. After 30 minutes tested in accordance with Method 301
of MIL-STD-202 unmated and mated.
Initial Contact Resistance Between 45 and 95 millivolts drop on wire sizes from 24 to 12.
Crimp contacts to meet MIL-C-23216.
Thermal Shock Unmated connectors tested in accordance with Method 107,
condition B of MIL-STD-202 except min. temp is –55oC.
Insulation Resistance at Elevated Temps (Short Time)
(Long Time)
Greater than 3 megohms 250 hr at 125oC
Greater than 12 megohms 1000 hr at 105oC
Durability 500 cycles of coupling and uncoupling
Vibration In accordance with Method 204 Condition B of MIL-STD–202
Shock Impulses of 50 G’s duration of 11 ±1 milliseconds
Moisture Resistance In accordance with Method 106 of MIL-STD-202
Corrosion Salt Spray to Method 101 Condition B of MIL-STD-202
Operating Forces From 0.905 Nm. (8 lb. In.) for shell size 8 to 4.971 Nm. (44 lb. in.)
for shell size 24.
Contact Resistance As per contact resistance test of MIL-C-23216.
(a) Solvent Immersion Hydraulic Fluid
(b) Solvent Immersion Lubricating Oil
Conforming to MIL-H-5606 20 hrs
Conforming to MIL-H-7808 20 hrs
Insert Retention Effective pressure differential of 5 17.0 KN/m2 (75 p.s.i..)
Insert Retention Hermetic Effective pressure differential of 13 80.0 KN/m2 200 (p.s.i.)
Contact Retention Crimp Axial loads between 6 6.67 N (15 lbf.) and 111.2 N (25 lbf.)
Amphenol 162GB Series
DESIGNED TO COMPL
Y WITH MIL
26482
SCHEDULE OF TESTS REQUIRED FOR
QUALIFICATION APPROVAL
4
Protective Covers and Storage
Tests Brief Description
Examination of Product Components suitability after storage and use of recommended Protective Covers
Operating Forces Measurement of Receptacles, Plugs and Protective Covers mating and unmating forces.
Moisture Resistance Crimp Contacts to Method 106 of MIL-STD-202.
Corrosion Salt Spray to Method 101, Condition B of MIL-STD-202.
Cover Chains Tensile Strength 111.2 N (25 lbf.) from various directions
Air Leakage 69.0 KN/m2 (10 p.s.i.) applied to inside of Protective Covers
Crimp Contact Retention Feature
Tests Brief Description
Examination of Product Test to establish Crimp effectiveness
Maintenance Ageing
(Contacts only) Involves repeated insertion/removal of contacts and mating and unmating of connectors.
Contact Retention Loads applied in both directions.
Connector Assembly Class J
Tests Brief Description
Examination of Product
Thermal Shock In accordance with Method 107 Condition B of MIL-STD-202
Water Pressure Immersion 1.829 m (6 ft.) under water for solder type connectors
Air Leakage Solder Receptacles 206.9 KN/m2 (30 p.s.i.) across connectors.
Others to Method 112 Condition C, Procedure 1 of MIL-STD-202
5
Table of Shell Styles
PLAIN SHELL
THREADED
SHELL
GROMMET SEAL
STRAIN RELIEF
CLAMP
(For details of Right
Angle Strain Relief
Clamps, see Page
20)
THREADED
SHELL
GROMMET SEAL
STRAIN RELIEF
CLAMP
(For details of Right
Angle Strain Relief
Clamps, see Page
BOX MOUNTING RECEPTACLES
(4-hole Fixing)
Page
BOX MOUNTING RECEPTACLES
(4-hole Fixing)
Page
SINGLE HOLE FIXING
RECEPTACLES
Page
162GB 12E
162GB 30T
162GB 14E
162GB
162GB 10F
162GB 14F
10E
CABLE MOUNTING
RECEPTACLES
Page
NON GROUNDED PLUGS
Page
162GB 31T
162GB 36T
11E 162GB 16E
162GB
16F
162GB
11F
162GB
CC1304 CC1305
162GB 37T
GROUNDED PLUGS
Page
162GB 36TG
6
Insert Availability
8 10 12 14 16 18 20
Notes
* These insert arrangements are not included in
Pattern 105 but are available and listed in MIL-
C-26482.
Due to the arrangement of contacts in the 14-12 insert
arrangement it is classified, for current derating, in
the shell size range 18-24.
Lettering of inserts shown above corresponds to views
of front (mating) surface of pin inserts or rear face
(cable accessory end) of socket inserts.
KEY ? No. 16 size contacts
? No. 20 size contacts
No. 12 size contacts
8-03
10-06
10-02
12-03
14-05
16-08
18-11
14-19
14-15
14-12
12-10 16-23*
16-26
18-32 20-41
15
10
5
0
CURRENT AMPS PER CONTACT
CURRENT AMPS PER CONTACT
0
1
2
3
4
5
SIZE 20 CONTACTS
SIZE 16 CONTACTS
-55 -25 0 25 50 75 100 125
AMBIENT TEMPERATURE oC
Current-temperature derating curve
8-98
8-33 10-07
20-16
16-04
12-08
7
Insert Availability
22 24
Rating 3 Sea Level
1013 mbart 8500m (27,900 ft)
320 mbar 21,340m (70,000 ft)
44 mbar
Working Voltage
Working Voltages ** (nominal)
d.c. or a.c. peak
Voltage Proof
d.c. or a.c. peak
III
1500
3000
III
800
1300
III
450
750
162GB only
Altitude
Rating 1
Sea Level
300mb at 20oC
8.500m
(27,800 ft)
44 mb at 20oC
20,000 m
(66,000 ft)
Rating 2
Sea Level
300mb at 20oC
8.500m
(27,800 ft)
44 mb at 20oC
20,000 m
(66,000 ft)
dc Working
Voltage
700
375
200
1250
550
300
ac Working
Voltage r.m.s.
500
265
140
900
390
210
Proof Voltage
500
265
140
3250
1750
775
FLASHOVER VOLTAGE kW
4
3
2
1
020
(6)
40
(12)
60
(18)
80
(24)
100
(30)
120
(36) 140
(42)
160
(48)
180
(54)
ALTITUDE
THOUSANDS OF FEET (METRES)
Relationship between flashover voltage and altitude
for each voltage rating
(Figures in bold type are from DEF STAN 59-35 (Part 1) Sec. 3 Patt. 105)
NOTES
Because safe working voltages at altitude above sea-level are dependent upon individual
conditions of use, these values are not specified in DEF STAN 59-35 (Part 1) Sec. 3 Patt.
105 but approximate values are included here for the guidance of designs.
VOLTAGE RATINGS
Two categories of voltage rating are specified in DEF STAN 59-35 (Part 1) Sec. 3 Patt.
105.
Rating 1 (700V d.c. working at sea-level)
Applicable to the high contact density inserts shown in the upper section of the insert
availability diagram above.
Rating 2 (1250V d.c. working at sea-level)
Applicable to the inserts shown in the lower section of the insert availability diagram.
Rating 3 (1500V d.c. working at sea-level)
(a) Maximum current per individual contact (in isolation)* at ambient temperature of 85oC
Contact Size 12: 23A
(b) Maximum current per contact through all contacts simultaneously at an ambient
temperature of 85oC
Contact Size 12: 20A
Altitude Derating
Information on voltage derating for operation at altitudes above se-level can be obtained
from the flashover voltage altitude curves on the left.
VOLTAGE RATING 2
VOLTAGE RATING 1
Working Voltage
8
Ordering Amphenol
162GB Series Connectors
HOW TO ORDER FROM MS CONNECTOR NUMBERS
Connector numbers in the AMPHENOL and MS numbering systems. Only alternative insert orientations are specified in MIL-C-26482 which does
not include alternative key/keyway orientations
MS31 -24 E18-11 P
162GB -14 E18-11 PX
X
Deviations
(218) Lever coupling ring
(044) Rough grip heavy duty
coupling ring
(639) Bright cadmium plated shells
(714) Cadmium Olive Drab
(416) Electroless Nickel
(608) Hard Black Anodised
(771) Black Zinc Cobalt
Orientation
Keys/Keyways:
B, C, E, F
Inserts:
W, X, Y, Z
Series Designation
162GB
Specification Key
1 Styles originally specified in
MIL-C-26482
3 Styles exclusive to DEF STAN
59-35 (Part 1) Sec. 3
Shell Style
0 - Receptacle, wall mounting
1 - Receptacle, cable mounting
2 - Receptacle, box mounting
4 - Receptacle, internally threaded,
with cable accessories as
illustrated, for single hole
mounting
6 - Plug, cable mounting
7 - Single hole fixing receptacle
Environmental Code
E - Insert seal and grommet seal
with grommet nut (excluding
12E which has plain shell and
no grommet nut)
F - As (E) but grommet nut has
integral strain relief clamp
T -Threaded shell for cable
accessories
162GB -3 6 E
Shell Style
Shell Size (in sixteenths of an inch)
8, 10, 12, 14,16, 18, 20, 22, 24
Number of Contacts
3, 5, 6, 7, 8, 10, 11, 12, 19, 21*,
23, 26, 32, 41, 55, 61
*consult factory for availability
Contact Style
P - Pins
S - Sockets
22 36 PB(044)
Insert Arrangement
-
9
Box Mounting Receptacles
Description Amphenol Part No Military No
30T 4-hole flange mounting
with threaded shell to
accept standard cable
accessories
162 Series
162GB-30T etc
10E 4-hole flange mounting
with grommet and
grommet nut
162 Series
162GB-10E etc MS3120E etc
10F
4-hole flange mounting
with grommet and
grommet nut fitted with
integral strain relief
clamp
162 Series
162GB-10F etc MS 3120F etc
12E
4-hole flange mounting
with plain shell for
direct wiring to exposed
solder buckets. Film
wire terminations
available on 62 Series
as deviation (219).
162 Series style has
integral grommet
162 Series
162GB-12E etc MS 3122E etc
A
Y
A
F
B
X
Thread
G
Y
A
G
F
B
H
Y
A
G
F
B
Y
A
L
G
L
A
B
F
10
Dimensions and Mounting Details
‘A’ Overall Length Max ‘L’ Shell Lengths
Shell Size
30T
in mm
(162)
10E
in mm
(162)
10F
in mm
(162)
12E
in mm
(162)
12E
in mm
08
10
12
14
16
18
20
22
24
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.348
34.24
1.348
34.24
1.348
34.24
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.382
35.10
1.382
35.10
1.382
35.10
1.759
44.68
1.759
44.68
1.759
44.68
1.733
44.02
1.873
47.575
1.873
47.575
2.115
53.72
2.115
53.72
2.247
57.075
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.348
34.24
1.348
34.24
1.348
34.24
0.917
23.29
0.917
23.29
0.917
23.29
0.917
23.29
0.917
23.29
0.917
23.29
0.980
24.89
0.980
24.89
1.023
29.895
Flange
thickness
±0.005
0.127)
Flange
dim.
max.
sq.
Flange
hole
centres
TP
Flange
holes dia.
±0.005
0.127)
-0.002
(-0.051)
Mtg.
Flange
location
±0.005
0.127)
Overall Rear
dia. max.
Cable
sleeve int.
dia.
±0.005
0.127)
Thread Shell ext.
dia. Max.
Shell
Size
B
in mm
C
in mm
D
in mm
E
in mm
F
in mm
30T
in mm
12E
in mm
G
10E
in mm
10F
in mm
H
10F only
in mm
X Y
in mm
08
10
12
14
16
18
20
22
24
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.080
2.03
0.080
2.03
0.080
2.03
0.817
20.75
0.942
23.925
1.036
26.315
1.130
28.70
1.223
31.065
1.317
33.45
1.442
36.625
1.567
39.80
1.692
42.98
0.594
15.09
0.719
18.26
0.812
20.625
0.906
23.10
0.969
24.61
1.062
26.575
1.156
29.36
1.250
31.75
1.375
34.925
0.120
3.05
0.120
3.05
0.120
3.05
0.120
3.05
0.120
3.05
0.120
3.05
0.120
3.05
0.120
3.05
0.147
3.735
0.445
11.3
0.445
11.3
0.445
11.3
0.445
11.3
0.445
11.30
0.445
11.3
0.555
14.095
0.555
14.095
0.590
14.985
0.434
11.02
0.558
14.17
0.683
17.35
0.808
20.52
0.933
23.70
1.057
26.85
1.182
30.02
1.307
33.20
1.432
36.37
0. 434
11.02
0.558
14.17
0.683
17.35
0.808
20.52
0.933
23.70
1.057
26.85
1.182
30.02
1.307
33.20
1.432
36.37
0.561
14.25
0.686
17.425
0.811
20.60
0.936
23.775
1.061
26.975
1.186
30.12
1.311
33.30
1.436
36.47
1.561
39.65
0.828
21.03
0.891
22.63
1.016
25.805
1.141
28.98
1.203
30.555
1.426
36.22
1.426
36.22
1.567
39.80
1.735
44.07
0.156
3.96
0.188
4.775
0.312
7.925
0.375
9.575
0.500
12.7
0.625
15.875
0.625
15.875
0.750
19.05
0.800
20.32
7/16-28 UNEF
9/16-24 NEF
11/16-24 NEF
13/16-20 UNEF
15/16-20 UNEF
11/16-18 NEF
13/16-18 NEF
15/16-18 NEF
17/16-18 NEF
0.473
12.015
0.590
14.99
0.750
19.05
0.875
22.225
1.000
25.4
1.125
28.575
1.250
31.75
1.375
34.925
1.500
38.1
162 OVERALL MATED DIMENSIONS
Add the two relevant plug and receptacle overall
dimensions and deduct:
- 0.365 (9.271mm) for shell sizes 20, 22, 24
- 0.303 (7.696mm) for all other sizes
When receptacles are
mounted on the rear
face of the panel, the
maximum value for
dimension W must not
be exceeded otherwise
the receptacle cannot
be mated to a plug
Receptacle
Shell
Panel
Panel thickness with screw head W max.
Shell Size in mm Shell Size in mm
08-18 0.100 20-24 0.210
2.540 5.330
W
11
Single Hole Fixing Receptacles
Description Amphenol Part No Military No
14E
Single hole fixing with
grommet and grommet
nut. Has panel O-ring
seal
162 Series
162GB-14E etc
14F
Single hole fixing with
grommet and grommet
nut fitted with integral
strain relief clamp.
Has panel O-ring seal
162GB Series
162GB-14F etc
37T Single hole fixing with
threaded shell to
accept accessories
162GB Series
162GB-37T etc
A
G
B
F
Y
M
K
X Thread
Y
M
F
B
H
A
K
G
X
Thread
A
G
B
F
Y
M
K
X Thread
12
Dimensions and Mounting Details
162 OVERALL MATED DIMENSIONS
Add the two relevant plug and receptacle overall dimensions and deduct -
- 0.365 (9.271mm) for shell sizes 20, 22, 24
- 0.303 (7.696mm) for all other sizes
SINGLE HOLE FIXING RECEPTACLES
PANEL PIERCING DETAILS
Panel Thickness Overall Length Max. A
Min. Max.
(162) (162)
Shell Size
Mounting
hole dia.
0.005
(±0.127)
R
in mm
Mounting
hole crs.
min.
S
in mm
Diameter
across flat
0.005
0.127)
N
in mm K
in mm
Shell Size 14E
in mm 14F
in mm
8
10
12
14
16
20
20
22
24
0.572
14.53
0.697
17.70
0.885
22.48
1.010
25.65
1.135
28.83
1.260
32.00
1.385
35.18
1.510
38.35
1.635
41.45
1.250
31.75
1.359
34.53
1.531
38.885
1.656
42.06
1.781
45.24
1.891
48.03
2.031
51.59
2.156
54.76
2.277
57.835
0.540
13.72
0.665
16.89
0.828
21.03
0.952
24.18
1.076
27.33
1.201
30.50
1.326
33.68
1.451
36.855
1.576
40.03
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.062
1.575
0.125
3.175
0.125
3.175
0.125
3.175
0.125
3.175
0.125
3.175
0.125
3.175
0.250
6.35
0.250
6.35
0.250
6.35
8
10
12
14
16
18
20
22
24
1.355
34.42
1.355
34.42
1.355
34.42
1.355
34.42
1.355
34.42
1.355
34.42
1.576
40.03
1.576
40.03
1.609
40.87
1.759
44.68
1.759
44.68
1.759
44.68
1.733
44.02
1.873
44.575
1.873
44.575
2.105
53.47
2.105
53.47
2.247
57.075
Flange
thick-
ness
±0.005
0.127)
Mtg.
Flange
location
±0.005
0.127)
Overall Rear
diameter
Cable Sleeve
int. dia.
±0.005
0.127)
Fixing
Nut A/F Fixing nut
thread
Thread flat
+0.000
0.005
(-0.127)
Shell Ext dia.
Max.
Shell Size
B
14E 14F
in mm
F
in
mm
14E
in mm
G
14F
in mm
H
14F
in mm
L
in mm
X M
in mm
Y
in mm
08
10
12
14
16
18
20
22
24
0.117
2.97
0.117
2.97
0.117
2.97
0.117
2.97
0.117
2.97
0.117
2.97
0.148
3.76
0.148
3.76
0.148
3.76
0.706
17.93
0.706
17.93
0.706
17.93
0.706
17.93
0.706
17.93
0.706
17.93
0.894
22.71
0.894
22.71
0.927
23.55
0.713
18.11
0.838
21.29
0.963
24.46
1.088
27.625
1.213
30.81
1.338
33.975
1.463
37.16
1.588
40.325
1.713
43.51
0.828
21.03
0.891
22.63
1.016
25.805
1.141
28.97
1.203
30.555
1.426
36.22
1.426
36.22
1.567
39.80
1.735
44.07
0.156
3.96
0.188
4.775
0.312
7.925
0.375
9.525
0.500
12.7
0.625
15.875
0.625
15.875
0.750
19.05
0.800
20.32
0.750
19.05
0.875
22.225
1.062
26.975
1.187
30.15
1.312
33.32
1.437
36.50
1.562
38.675
1.687
42.85
1.812
46.05
9/16-24 NEF
11/16-24 NEF
? - 20 UNEF
1-20 UNEF
1? -18 NEF
1¼ -18 NEF
1? -18 NEF
1½ -18 NEF
1? -18 NEF
0.527
13.3
0.652
16.56
0.815
20.70
0.939
23.85
1.063
27.00
1.188
30.175
1.313
33.35
1.438
36.53
1.563
39.70
0.473
12.025
0.590
14.99
0.750
19.05
0.875
22.225
1.000
25.40
1.125
28.575
1.250
31.75
1.375
34.925
1.500
38.10
J
K
57A
(219)
5016, 5005, 5024
D
R
N
C
L
13
Cable Mounting Receptacles
Description Amphenol Part No Military No
31T
Basic cable mounting
receptacle with
threaded shell to
accept standard cable
accessories
162 Series
62GB-31T etc
11E Cable mounting
receptacle with
grommet and grommet
nut
162 Series
162GB-11E etc
11F
Cable mounting
receptacle with
grommet and grommet
nut fitted with integral
strain relief clamp
162 Series
162GB-11F etc MS 3121F etc
X THREAD
14
Dimensions and Mounting Details
162 OVERALL MATED DIMENSIONS
Add the two relevant plug and receptacle overall
Dimensions and deduct:
- 0.365 for shell sizes 20, 22, 24 (9.271)
- 0.303 for all other sizes (7.696)
‘A’ Overall Length Max.
Shell Size
31T
in
mm
(162)
11E
in
mm
(162)
11F
in
mm
08
10
12
14
16
18
20
22
24
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.286
32.665
1.348
34.24
1.348
34.24
1.348
34.24
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.320
33.53
1.382
35.10
1.382
35.10
1.382
35.10
1.759
44.68
1.759
44.68
1.759
44.68
1.733
44.02
1.873
47.575
1.873
47.575
2.115
53.72
2.115
53.72
2.247
57.07
Flange
thickness
ness
±0.005
0.127)
Flange
dimensions
max.
sq.
Flange
location
±0.005
0.127)
Overall rear diameter
Max.
Cable Sleeve
int. dia.
±0.005
0.127)
Thread Shell ext. dia.
Max.
B C F G H X Y
Shell Size
in mm
in mm
in mm 11F
in mm 11E
in mm 11F
in mm 31T
in mm
08
10
12
14
16
18
20
22
24
0.094
2.39
0.094
2.39
0.094
2.39
0.094
2.39
0.094
2.39
0.094
2.39
0.104/0.100
2.64/2.55
0.104/0.100
2.64/2.55
0.104/0.100
2.64/2.55
0.817
20.75
0.942
23.925
1.036
26.315
1.130
28.70
1.223
31.065
1.317
33.45
1.442
36.63
1.567
39.80
1.692
42.98
0.415
10.54
0.415
10.54
0.415
10.54
0.415
10.54
0.415
10.54
0.415
10.54
0.535
13.59
0.535
13.59
0.560/0.574
14.225/14.58
0.828
21.03
0.891
22.63
1.016
25.805
1.141
28.97
1.203
30.555
1.426
36.22
1.426
36.22
1.567
39.80
1.735
44.07
0.561
14.25
0.686
17.425
0.811
20.60
0.936
23.775
1.061
26.95
1.186
30.125
1.311
33.30
1.436
36.745
1.561
39.65
0.156
3.96
0.188
4.775
0.312
7.925
0.375
9.525
0.500
12.7
0.625
15.875
0.625
15.875
0.750
19.05
0.800
20.32
7/16-28 UNEF
9/16-24 NEF
11/16-24 NEF
13/16-28 UNEF
15/16-20 UNEF
11/16-18 NEF
13/16-18 NEF
15/16-18 NEF
17/16-18 NEF
0.473
12.025
0.590
14.99
0.750
19.05
0.875
22.225
1.000
25.4
1.125
28.575
1.250
31.75
1.375
34.925
1.500
38.10
15
Plugs
Description Amphenol Part No Military No
36T
36TG
Basic plug with
threaded shells to
accept standard cable
accessories
Basic plug with
grounding spring,
threaded shell to
accept standard cable
accessories
162 Series
162GB-36T etc
162 Series
162GB-16E etc
16E Plug with grommet and
grommet nut 162 Series
162GB-16E etc MS 3126E etc
16F Plug with grommet and
grommet nut fitted with
integral strain relief
clamp
162 Series
162GB-16F etc MS3126F etc
X Thread
16
Dimensions and Mounting Details
‘A’ Overall Length max.
Shell Size
36T and 36TG
in mm
16F
in mm
(162)
16E
in mm
08
10
12
14
16
18
20
22
24
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.277
32.44
1.752
44.50
1.752
44.50
1.752
44.50
1.726
43.84
1.866
47.40
1.866
47.40
2.045
51.94
2.045
51.94
2.178
55.32
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
1.310
33.27
162 OVERALL MATED DIMENSIONS
Add the two relevant plug and receptacle overall
Dimensions and deduct:
- 0.365 (9.271mm) for shell sizes 20, 22, 24
- 0.303 (7.696mm) for all other sizes
Overall dia.
Max. Coupling Ring
dia. max. Overall rear diameter
Max.
Cable Sleeve int. dia.
±0.005
0.127)
C Y G H
Shell Size
in mm
in mm 16E
in mm 16F
in mm 16F
in mm
08
10
12
14
16
18
20
22
24
0.750
19.05
0.859
21.82
1.031
26.19
1.156
29.36
1.281
32.54
1.391
35.33
1.531
38.89
1.656
42.06
1.777
45.135
0.750
19.05
0.859
21.82
1.031
26.19
1.156
29.36
1.281
32.54
1.391
35.33
1.531
38.89
1.656
42.06
1.777
45.135
0.561
14.25
0.686
17.425
0.811
20.60
0.936
23.775
1.061
26.95
1.186
30.125
1.311
33.30
1.436
36.745
1.561
39.65
0.828
21.03
0.891
22.63
1.016
25.805
1.141
28.97
1.203
30.555
1.426
36.22
1.426
36.22
1.567
39.80
1.735
44.07
0.156
3.96
0.188
4.775
0.312
7.925
0.375
9.525
0.500
12.7
0.625
15.875
0.625
15.875
0.750
19.05
0.800
20.32
17
Plugs with optional
Coupling Rings
Description Amphenol Part No
(044)
Heavy duty coupling ring.
Available for any of the plugs listed
on page 22
To order complete assembly, add
deviation (044) to connector
number
162 Series
162GB-XXXXX-XX(044)
(218)
Lever coupling ring. Mating and
unmating only requires 120o
movement.
Available in shell size 14 and 16
only. Other sizes to special order.
162 Series
162GB-XXXXX-XX(218)
Dimensions and Mounting Details
HEAVY DUTY COUPLING RINGS
Shell Size Overall dia. max.
W (044) in mm
08
10
12
14
16
18
20
22
24
0.870
22.1
0.979
24.865
1.151
29.235
1.276
32.41
1.401
35.585
1.505
38.225
1.651
41.935
1.776
45.11
1.897
48.18
LEVER COUPLING RINGS
Shell Size A Max in mm C Max. in mm
14
16
1.444
36.67
1.444
36.67
0.787
19.98
0.844
21.43
AUDIO CONNECTORS FOR TINSEL CORD
A Max in mm
Shell Size 162GB-0506-10-6PX
162GB-0506-10-7PX 162GB-5001-10-7SX B dia. Max
in mm H Cable Outlet Min
in mm
10 2.375
60.325 2.75
69.85 0.875
22.225 0.276
7.01
W
W
18
Cable Accessories
SUITABLE FOR ALL EXTERNALLY THREADED
PLUG OR RECEPTACLE SHELLS
Description Amphenol Part No
214
Grommet seal and nut. Provides an
environmental seal for the exposed
solder buckets in the openback class T
shells.
Grommet nut only for 162 Series.
162 Series
162GB-214-XX
For Shell sizes 08-24 respectively
129
Grommet and nut with strain relief
clamp. The clamp prevents the flexing
of the wires in the immediate vicinity of
he risers, so avoiding the risk of leaks.
Grommet nut with strain relief clamp only
for 162 Series.
162Series
162GB-239-XX
201
Grommet and nut with right-angled strain
relief clamp. The clamp prevents flexing
of the wires in the immediate vicinity of
the risers, so avoiding the risk of leaks
(these are supplied to separate order
only for use with style T shells).
Grommet nut with strain relief clamp only
for 162 Series.
162GB Series
162GB-201-XX
5000
75o Clamp for screened jacketed cable
with grommet. Effective sealing is
provided over the range of cables
covered by DEF 10 (Pattern C) as
specified in DEF 5325-3. These are
supplied to separate order only and are
intended for use with style T shells.
162 Series
162GB-5000-XX--XX**
* The suffix XX-XP or S enables the grommet to be matched to the insert arrangement (e.g. 12-3P).
** The suffix XX specifies the cable size.
The suffix XX specifies the shell size.
A
G
H
A
Q
G
Q
A
B
19
Dimensions and Mounting Details
CABLES TO DEF STAN 10 and DEF STAN 61-12 part 5
e.g. def 10-3A or DEF STAN 16-2-3A
PLANFORM CABLE
DEF 10-etc DEF
STAN 16-2 etc PLANFORM
CABLE
DEF 10 etc
DEF STAN
16-2 etc
PLANFORM
CABLE
DEF 10-etc
DEF STAN 16-
2 etc
8-3 3A,3B,3C,2B 14-12 C 12A,12B,12C 20-16 -
8-3 3 C 3A,3B,3C,2B 14-15 - 20-41 C 36C
10-2 2A,2B,2C,2Q 16-8 - 22-55 -
10-6 C 6A,6B,6C,4C 16-23 C - 24-61 C 60C
12-3 C 3A,3B,3C,2Q• 16-26 25A,25B,25C
12-10 10C 18-11 - - -
Applicable to DEF10 only
Part Number Examples:
162GB-151-14-12 (no grommet supplied)
Type A Cables:
Type B Cables:
Type C Cables:
Type Q Cables:
PVC outer sheath, no overall screen, L.T. (14/.0076) unscreened cores
(equivalent DEF STAN 16-2 wire size)
Outer screen, inner PVC sheath, L.T. (14.0076) unscreened cores
(equivalent DEF STAN 16-2 wire size)
Outer PVC sheath, inner screen, L.T. (14.0076) unscreened cores
(equivalent DEF STAN 16-2 wire size)
Outer screen, inner PVC sheath, L.T. (36/.012) unscreened cores
(DEF 10 only)
Overall Length (max.) Straight SJ Clamps 162GB-151-XX
max 75o SJ Clamps 162GB-5000-XX
max
Shell Size
162GB-201-XX
162GB-129-XX
in mm 162GB-160-168
in mm Length including
plug in mm
Length including
receptacle
in mm
Length including
plug
in mm
Length including
receptacle in mm
08
10
12
14
16
18
20
22
24
15/32
13/16
17/32
11/4
15/16
13/8
13/8
129/64
115/32
0.991
25.17
0.991
25.17
0.991
25.17
0.965
24.51
1.105
28.065
1.105
28.065
1.285
32.64
1.285
32.64
1.373
34.875
0.545
13.84
0.545
13.84
0.545
13.84
0.545
13.84
0.545
13.84
0.545
13.84
0.545
13.84
0.545
13.84
0.501
12.725
2.732
69.39
2.742
69.64
3.152
80.06
3.152
80.06
3.272
83.10
-
-
3.272
83.10
-
-
3.696
93.87
2.742
69.64
2.752
69.90
3.162
80.31
3.162
80.31
3.282
83.36
-
-
3.345
84.96
-
-
3.768
95.70
2.375
60.235
2.532
64.39
2.625
66.675
2.719
69.035
2.750
69.80
-
-
3.250
82.55
-
-
3.375
85.725
2.416
61.365
2.573
65.35
2.666
67.715
2.760
70.095
2.790
70.87
-
-
3.312
84.125
-
-
3.500
88.90
B dia. max G J K L
Shell Size
162GB-151-XX
162GB-5000-XX
in mm
162GB-129-XX
in mm 162GB-214 P or S
in mm All SJ Clamps
in mm
Cable Sleeve
Int. dia. ±0.005
±0.127
162GB-201-XX
in mm
36T
162GB-5000-XX
in mm
08
10
12
14
16
18
20
22
24
0.676
17.17
0.676
17.17
0.812
20.62
0.926
23.52
1.051
26.695
-
-
1.280
32.51
-
-
1.620
41.15
0.828
21.03
0.891
22.63
1.016
25.805
1.141
28.98
1.203
30.555
1.426
36.22
1.426
36.22
1.567
39.80
1.735
44.07
0.561
14.25
0.686
17.425
0.811
20.60
0.936
23.775
1.061
26.95
1.186
30.125
1.311
33.30
1.436
36.745
1.561
39.65
0.775
19.68
0.902
22.91
1.030
26.16
1.157
29.385
1.284
32.61
-
-
1.539
39.09
-
-
1.783
45.29
0.161
4.09
0.193
4.90
0.317
8.05
0.380
9.65
0.505
12.83
0.630
16.00
0.630
16.00
0.755
19.175
0.805
20.45
0.733
18.62
0.795
20.19
0.858
21.79
0.915
23.24
1.010
25.65
1.070
27.18
1.140
28.955
1.170
29.72
1.260
32.00
1.750
44.45
1.875
47.625
2.125
53.975
2.125
53.975
2.062
52.375
-
-
2.062
52.375
-
-
2.187
55.55
SJ CLAMPS
The 162 series clamps are identical to the 62 series
clamps except that the grommet is omitted. It is
however, still necessary to quote the full planform
because the piece parts vary to suit the appropriate
cable.
SJ clamps are available in 62 series only where
there is an appropriate cable to DEF 10 or DEF
STAN 61-12 part 5 available for the planform.
162 series availability is similar according to the
planforms tooled. These are marked C on the table.
20
Dust Caps
TABLE OF STYLES
62GB-736
62GB-738
62GB-742
62GB-810
62GB-812
62GB-813
21
Dust Caps
TABLE OF STYLES
62GB-997
62GB-998
62GB-1069
62GB-1070
22
Dust Caps
TABLE OF STYLES
736
62GB-736
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.734
18.64
0.859
21.82
1.000
25.4
1.125
28.57
1.250
31.75
1.375
34.92
1.500
38.1
1.625
41.27
1.750
44.45
0.578
14.68
0.703
17.86
0.891
22.63
1.016
25.81
1.141
29.39
1.266
32.16
1.391
35.33
1.516
38.51
1.641
41.68
738
62GB-738
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.734
18.64
0.859
21.82
1.000
25.4
1.125
28.57
1.250
31.75
1.375
34.92
1.500
38.1
1.625
41.27
1.750
44.45
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.152
3.66
Caps and Chains for Single Hole
Mounting Receptacles
Caps and Chains for Flange Mounting
Receptacles
23
Dust Caps
TABLE OF STYLES
742
62GB-742
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.522
13.25
0.522
13.25
0.522
13.25
0.522
13.25
0.522
13.25
0.522
13.25
0.584
14.83
0.584
14.83
0.617
15.67
0.719
18.26
0.844
21.43
1.000
25.4
1.125
28.57
1.250
31.75
1.357
34.92
1.500
38.1
1.625
41.27
1.750
44.45
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.125
3.18
0.152
3.86
Caps and Chains for Single Hole
Mounting Receptacles
24
Dust Caps
TABLE OF STYLES
810
62GB-810
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.522
13.25
0.522
13.25
0.522
13.25
0.522
13.25
0.522
13.25
0.584
14.83
0.584
14.83
0.617
15.67
0.719
18.26
0.844
21.43
1.000
25.4
1.125
28.57
1.250
31.75
1.500
38.1
1.625
41.27
1.750
44.45
0.145
3.68
3.685
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.171
4.34
812
62GB-812
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.734
18.64
0.859
21.82
1.000
25.4
1.125
28.57
1.250
31.75
1.375
34.92
1.500
38.1
1.625
41.27
1.750
44.45
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.145
3.68
0.171
4.34
Caps and Cords for Plugs
BS9522-F0017-A2013
Caps and Cords for Flange Mounting
Receptacles
BS9522-F0017-A2012
25
Dust Caps
TABLE OF STYLES
813
62GB-813
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.734
18.64
0.859
21.82
1.000
25.4
1.125
28.57
1.250
31.75
1.375
34.92
1.500
38.1
1.625
41.27
1.750
44.45
0.578
14.68
0.703
17.86
0.891
22.63
1.016
25.81
1.141
29.39
1.266
32.16
1.391
35.33
1.516
38.56
1.641
41.68
BS9522-F0017-A2014
Caps and Cords for Single
Hole Mounting Receptacles
26
Dust Caps
TABLE OF STYLES
997
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.892
22.66
1.017
26.84
1.142
29.01
1.267
32.19
1.454
36.94
1.563
39.70
1.687
42.85
1.797
45.65
1.922
48.82
0.578
14.69
0.703
17.86
0.891
22.64
1.016
25.81
1.141
28.99
1.266
32.16
1.391
35.34
1.516
38.51
1.641
41.69
998
62GB-998
Shell Size A
± 0.25
(± 6.35) g max C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.562
14.28
0.562
14.28
0.562
14.28
0.562
14.28
0.562
14.28
0.562
14.28
0.624
15.85
0.624
15.85
0.624
15.85
0.892
22.66
1.017
25.84
1.142
29.01
1.267
32.19
1.454
36.94
1.563
39.70
1.687
42.85
1.797
45.65
1.922
48.82
0.124
3.18
0.124
3.18
0.124
3.18
0.124
3.18
0.124
3.18
0.124
3.18
0.124
3.18
0.124
3.18
0.147
3.74
Caps and Chains Ribbed for Single
Hole Mounting Receptacles
62GB
-
997
Caps and Chains Ribbed for Plugs
27
Dust Caps
TABLE OF STYLES
1069
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.010
(± 0.25)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.892
22.66
1.017
26.84
1.142
29.01
1.267
32.19
1.454
36.94
1.563
39.70
1.687
42.85
1.797
45.65
1.922
48.82
0.578
14.69
0.703
17.86
0.891
22.64
1.016
25.81
1.141
28.99
1.266
32.16
1.391
35.34
1.516
38.51
1.641
41.696
1070
Shell Size A
± 0.25
(± 6.35)
B
± 0.005
(± 0.13) C dia. Max J
± 0.005
(± 0.127)
08
10
12
14
16
18
20
22
24
3.0
76.2
3.0
76.2
3.5
88.9
3.5
88.9
3.5
88.9
3.5
88.9
4.0
101.6
4.0
101.6
4.0
101.6
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.521
13.23
0.556
14.12
0.892
22.66
1.017
22.66
1.142
29.01
1.267
32.19
1.454
36.94
1.563
39.70
1.687
42.85
1.797
45.65
1.922
48.82
0.117
3.03
0.119
3.03
0.119
3.03
0.119
3.03
0.119
3.03
0.119
3.03
0.110
3.03
0.119
3.03
0.147
3.74
62GB
-
1069
Caps and Cords Ribbed for Single
Hole Mounting Receptacles
62GB
-
1070
Caps and Cords Ribbed for Flange
Mounting Receptacles
28
Interconnection Accessories
5001 BACKSHELL SERIES
For use on 162GB connector styles
The 5001 Backshells are suitable for termination
using Bandit, Zetalock and Heatshrink product
The 5001 Backshell is designed to give 360o
screening
Part Numbering Information
AIA50 01 XX XX XX XX XX XX
Denotes Backshell Style
50 Zeta Lock Termination with
Heatshrink Boot Groove
51 Spin Coupler to take Heatshrink Boot
Denotes Connector Style
01 Series 2 162GB
Denotes Connector Shell Size
8, 10, 12, 14, 16, 18, 20, 22, 24
Denotes Backshell Inlet Size
See Chart for Inlet Standard
Consult Factory for alternatives
Denotes Backshell Exit Angle
00 = 0o
45 45o
90 90o
Consult Factory for alternatives
Denotes Working Length
10 Standard
Consult Factory for alternatives
Denotes Backshell Material
AA Aluminium Alloy
RB Aluminium Bronze
SS Stainless Steel
Denotes Backshell Plating Finish
01 Unplated
02 Electroless Nickel
03 Cadmium with Olive Drab Chromate Passivation
04 Zinc Cobalt with Green Chromate Passivation
05 Zinc Cobalt with Black Chromate Passivation
29
Interconnection Accessories
5001 BACKSHELL SERIES - STRAIGHT
Part Number A-Thread ØB MAX
ØG MAX
ØH MAX
Rec Hellerman
Boot 90o Rec Hellerman
Boot Straight Spring Ref
5001-08-00-00-10-AA-XX
5001-10-00-00-10-AA-XX
5001-12-00-00-10-AA-XX
5001-14-00-00-10-AA-XX
5001-16-00-00-10-AA-XX
5001-18-00-00-10-AA-XX
5001-20-00-00-10-AA-XX
5001-22-00-00-10-AA-XX
5001-24-00-00-10-AA-XX
5001-08-06-00-10-AA-XX
5001-10-08-00-10-AA-XX
5001-12-10-00-10-AA-XX
5001-14-12-00-10-AA-XX
5001-16-14-00-10-AA-XX
5001-18-16-00-10-AA-XX
5001-20-18-00-10-AA-XX
5001-22-20-00-10-AA-XX
5001-24-22-00-10-AA-XX
7/16-28 UNEF
9/16-24 UNEF
11/16-24 UNEF
13/16-20 UNEF
15/16-20 UNEF
1 1/16-18 UNEF
1 3/16-18 UNEF
1 5/16-18 UNEF
1 7/16-18 UNEF
7/16-28 UNEF
9/16-24 UNEF
11/16-24 UNEF
13/16-20 UNEF
15/16-20 UNEF
1 1/16-18 UNEF
1 3/16-18 UNEF
1 5/16-18 UNEF
1 7/16-18 UNEF
18.14
20.45
24.64
29.13
32.13
32.64
39.78
43.28
44.25
18.14
20.45
24.64
29.13
32.13
32.64
39.78
43.28
44.25
6.48
8.05
11.25
12.83
16.00
19.18
22.38
25.55
25.55
4.83
6.48
8.05
11.25
12.83
16.00
19.18
22.38
25.55
14.04
15.61
18.81
20.39
23.57
26.74
29.92
33.09
33.09
14.04
14.04
15.61
18.81
20.39
23.57
26.74
29.92
33.09
1152-4-GW24
1154-4-GW24
1155-4-GW24
1155-4-GW24
1156-4-GW24
1156-4-GW24
1157-4-GW24
1157-4-GW24
1157-4-GW24
1152-4-GW24
1154-4-GW24
1155-4-GW24
1155-4-GW24
1156-4-GW24
1156-4-GW24
1157-4-GW24
1157-4-GW24
1157-4-GW24
152-42-GW24
154-42-GW24
155-42-GW24
155-42-GW24
155-42-GW24
156-42-GW24
157-43-GW24
157-43-GW24
157-43-GW24
152-42-GW24
154-42-GW24
155-42-GW24
155-42-GW24
156-42-GW24
156-42-GW24
157-43-GW24
157-43-GW24
157-43-GW24
HE 050
HE 100
HE 100
HE 200
HE 200
HE 300
HE 300
HE 300
HE 300
HE 050
HE 050
HE 100
HE 100
HE 200
HE 200
HE 300
HE 300
HE 300
All dimensions in mm
36.35 MAX
29.95 MAX
ØB MAX
A THREAD
ØG MAX
ØH MAX
30
Interconnection Accessories
5001 BACKSHELL SERIES RIGHT ANGLE
Part Number A-Thread D MAX ØB MAX
E MAX ØG MAX
ØH MAX J MAX Rec Hellerman
Boot Straight Spring Ref
5001-08-00-90-AA-XX
5001-10-00-90-AA-XX
5001-12-00-90-AA-XX
5001-14-00-90-AA-XX
5001-16-00-90-AA-XX
5001-18-00-90-AA-XX
5001-20-00-90-AA-XX
5001-22-00-90-AA-XX
5001-24-00-90-AA-XX
5001-08-06-90-AA-XX
5001-10-08-90-AA-XX
5001-12-10-90-AA-XX
5001-14-12-90-AA-XX
5001-16-14-90-AA-XX
5001-18-16-90-AA-XX
5001-20-18-90-AA-XX
5001-22-20-90-AA-XX
5001-24-22-90-AA-XX
7/16-28 UNEF
9/16-24 UNEF
11/16-24 UNEF
13/16-20 UNEF
15/16-20 UNEF
1 1/16-18 UNEF
1 3/16-18 UNEF
1 5/16-18 UNEF
1 7/16-18 UNEF
7/16-28 UNEF
9/16-24 UNEF
11/16-24 UNEF
13/16-20 UNEF
15/16-20 UNEF
1 1/16-18 UNEF
1 3/16-18 UNEF
1 5/16-18 UNEF
1 7/16-18 UNEF
35.18
38.35
39.75
46.30
47.70
47.70
55.63
58.80
58.80
33.40
36.58
39.75
44.53
47.70
47.70
55.63
58.80
58.80
18.14
20.45
24.64
29.13
32.13
32.64
39.78
43.28
44.25
18.14
20.45
24.64
29.13
32.13
32.64
39.78
43.28
44.25
25.98
29.16
32.33
37.11
40.28
40.28
48.21
51.38
51.38
25.98
29.16
32.33
37.11
40.28
40.28
48.21
51.38
51.38
6.48
8.05
11.25
12.83
16.00
19.18
22.38
25.55
25.55
4.83
6.48
8.05
11.25
12.83
16.00
19.18
22.38
25.55
14.04
15.61
18.81
20.39
23.57
26.74
29.92
33.09
33.09
14.04
14.04
15.61
18.81
20.39
23.57
26.74
29.92
33.09
32.39
35.56
38.74
43.51
46.69
46.69
54.61
57.79
57.79
32.39
35.56
38.74
43.51
46.69
46.69
54.61
57.79
57.79
152-42-GW24
154-42-GW24
155-42-GW24
155-42-GW24
156-42-GW24
156-42-GW24
157-43-GW24
157-43-GW24
157-43-GW24
152-42-GW24
154-42-GW24
155-42-GW24
155-42-GW24
156-42-GW24
156-42-GW24
157-43-GW24
157-43-GW24
157-43-GW24
HE 050
HE 100
HE 100
HE 200
HE 200
HE 300
HE 300
HE 300
HE 300
HE 050
HE 050
HE 100
HE 100
HE 200
HE 200
HE 300
HE 300
HE 300
All dimensions in mm
J MAX
E MAX
ØG
MAX
ØH
MAX
A THREAD
ØB THREAD
17.98 MAX
D MAX
31
Interconnection Accessories
INSTALLATION - PROCEDURE
Prepare the cable making sure that a sufficient length of shield is available, so that it fits against the front shoulder of the lip groove.
Before insertion of connector contacts, slide the heat-shrinkable connector boot onto the cable followed by the Spring Adapter.
Position the heatshrinkable boot, Spring Adapter, and shield braid out of the way and insert the connector contacts.
Depending upon the shielding braid size, it can either be folded back onto itself or bunched up concertina style out of the way
for easy access to the cable conductors.
Screw the Spring Adapter onto the connector and tighten to the torque value specified by the connector manufacturer. Typical
torque values are shown in table on Page 7. It is recommended that the connector threads are lubricated with a suitable
compound if a liquid thread lock is not used. The adapter should be hand tightened to ensure proper thread alignment and
then tightened with a strap wrench and torque meter to the specified torque.
Bring the cable shield braid up onto the adapter body so that it fits against the front shoulder of the lip groove. Alternatively
extend the braid past the lip groove.
NOTE: After assembly, braid can be trimmed with side cutters
or folded back and secured with high temperature tape
Open up the constant force spring and wrap it around the cable braid section that is positioned over the constant force spring
slot area of the adapter. This is most easily accomplished by lifting up the end of the spring and trapping the braid covered
adapter between the spring coil and raised end. The spring will now stay in place and can be installed by simply rolling the
coil around the braid covered adapter. Refer to appropriate code of practice for procedure to install heatshrink shape.
Lift Up End of Spring
Trap Braid Covered Adapter
between Spring Coil and raised
end
Roll Spring Coil around
Adapter
Secure Cable Braid
End with Tape
Fold Cable Braid back
32
Interconnection Accessories
INSTALLATION - PROCEDURE
Re-Entry Procedure
Reheat the heatshrink shape, remove to expose the ZetalokTM? spring and braid.
Once spring is exposed, lift up the edge of the ZetalokTM spring and push it around the circumference of the assembly to form
a coil which can then be rolled around the assembly to remove the spring.
Lift the cable screen braid off the backshell and push it back out of the way.
Unscrew the backshell and push it back out to facilitate repairs at the connector or exposed connector area.
Follow the practice detailed in these instructions to re-install the ZetalokTM spring backshell
Note: The ZetalokTM? spring can be installed and removed an infinite number of times if not bent or distorted in any way during the
removal process.
33
Interconnection Accessories
SHIELD TERMINATION ASSEMBLY PROCESS
1. Prepare Cable Braid for termination process (Figure 1)
2. Push Braid forward over Adapter Retention Lip to the
Adapter Incline Point (or .4” [10.2mm] minimum braid
length). Milk Braid as required to remove slack and
ensure a snug fit around the shield termination area
(Figure 2).
3. Prepare the Band in the following manner:
IMPORTANT: Due to Connector/ Adapter
circumference, it may be necessary to prepare the
Band around the Cable or Retention Area.
a) Roll Band through the Buckle Slot twice (Bands must
be double-coiled).
b) Pull on Band until Mark (¨È) is within approximately
(.250 inch (6.4mm) of Buckle Slot (Figure 3). The
Band may be tightened further if desired.
NOTE: Prepared Band should have (¨È) Mark visible
approximately where shown in Figure 3.
SHIELD TERMINATION CLAMPING PROCESS (Figures
4 through 8):
NOTE: To free Tool Handles, move Holding Clips to
centre of Tool.
4. Squeeze Gripper Release Lever and insert Band into the
front end opening of the Tool. (NOTE: Circular portion of
looped band must always be face downward).
5. Aligning the Band and Tool with the Shield Termination
Area, squeeze Black Pull-Up Handle repeatedly using
short strokes until it locks against the Tool Body. (This
indicates the Band is compressed to the Tool
Precalibrated Tension).
NOTE: If alignment of band and shield is
unsatisfactory, tension on band can be relaxed by
pushing on slotted release lever on top of tool. Make
adjustments as necessary and again squeeze black
pull-up handle.
6. Complete the Clamping Process by squeezing the Grey
Cut-Off Handle.
7. Remove excess Band from Tool.
8. Inspect Shield Termination.
Adapter Retention Lip
Conductors Braid
Adapter
Incline
Buckle Tail Length
Indicator Mark
.400 (1.2mm)
Minimum Length
Braid over
Termination area
34
Key/Keyway Orientations
FOR Patt. 105 DEF STAN 59-35 (Part 1) Sec. 3
Values for a(degrees) Values for ? (degrees) Values for ß (degrees)
Shell
Size
N A* B C D* E F N A* B C D* E F N A* B C D* E F
8
10
12
14
16
18
20
22
24
105
105
105
105
105
105
105
105
105
92
95
97
98
99
100
100
101
101
-
85
89
91
93
95
95
97
97
-
125
121
119
117
115
115
113
113
118
115
113
112
111
110
110
109
109
118
115
115
75
75
75
75
75
75
82
85
85
120
120
120
120
120
120
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
-
35
35
35
35
35
35
35
35
-
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
30
30
30
30
30
30
30
30
30
50
50
50
50
50
50
50
50
50
75
75
75
75
75
75
75
75
75
75*
75
75
75
75
75
75
75
75
-
75
75
75
75
75
75
75
75
-
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
100
100
100
100
100
100
100
100
100
75
75
75
75
75
75
75
75
75
Values for f (degrees)
Orientation Values for ? (degrees)
Orientation
Shell
Size
N A* B C D* E F N A* B C D* E F
8
10
12
14
16
18
20
22
24
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
-
50
50
50
50
50
50
50
50
-
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
30
30
30
30
30
30
30
30
30
45
45
45
35
35
35
35
35
35
60
60
60
60
60
60
60
60
60
47
50
52
53
54
55
55
56
56
-
40
44
46
48
50
50
52
52
-
80
76
74
72
70
70
68
68
73
70
68
67
66
65
65
64
64
73
70
70
30
30
30
30
30
30
47
50
50
75
75
75
75
75
75
Datum is always taken from major key or keyway.
In receptacles the m
ajor keyway always remains
fixed in relation to the mounting flange. For the
A*, B, C, D*, E and F orientations, the three
bayonet locations and associated minor keyways
are rotated complete, in accordance with the
table below.
N.B. The accompanying diag
ram shows a
receptacle shell, with keyways. Corresponding
key orientations for a mating plug shell are
therefore always clockwise.
3 Pins spaced
120o apart
* now inactive for new designs
against Pattern 105 but available for
replacement purposes. Superseded
in DEF STAN 59-35 (Part 1) Sec. 3.
by orientations E and F.
35
Insert Orientations
FOR MIL-C-26482 AND REPLACEMENT PURPOSES
IN Patt. 105 OF DEF STAN 59-35 (Part 1) Sec. 3
Normal Position
with Pin Contacts Alternative Position of Insert
with Socket Contacts
(Ø counterclockwise)
Alternate Position of Insert
with Pin Contacts
(Ø clockwise)
Each diagram shows mating face of insert
Orientation 0 (degrees)
Insert Arrangement Normal W X Y Z
8-3 0 60 210 - -
8-33 0 90 - - -
8-98 0 - - - -
10-2 0 - - - -
10-6 0 90 - - -
10-7 0 - - - -
12-3 0 - - 180 -
12-10 0 60 155 270 295
14-5 0 40 92 184 273
14-12 0 43 90 - -
14-19 0 30 165 315 -
16-8 0 54 152 180 331
16-23 0 158 270 - -
16-26 0 60 - 275 338
18-11 0 62 119 241 340
18-32 0 85 138 222 265
20-41 0 45 126 225 -
22-21 0 16 135 175 349
22-55 0 30 142 226 314
24-61 0 90 180 270 324
36
Assembly Instructions FOR AMPHENOL STRAIGHT S.J. CLAMPS TO
DEF STAN 59-35 (Part 1) Sec. 3 FOR
INTERNALLY AND EXTERNALLY SCREENED AND UNSCREENED CABLES
INTERNALLY SCREENED JACKETED CABLE TYPE C
Cable and Wire Stripping
Strip the outer P.V.C. Jacket of the cable back to dim ‘A’ to expose the
internal braid. Trim the braid back to within 19.05mm (0.75 in) of
P.V.C. jacket and fold back ‘B’
A Dimension
Size mm in
08
10
12 & 14
16 & 20
24
34.93
36.51
41.27
44.45
49.21
1.375
1.437
1.625
1.750
1.937
FOR 162 SERIES
Strip 5.6
mm (0.220 in) to 6.6mm (0.260 in) of insulation from each wire
taking care not to cut or nick strands. If ends fray twist them back to
their original lay.
INITIAL ASSEMBLY
Slide onto the cable the following items in this order (1) Nut (2) Washer
(3) Gasket (4) Braid Clamp and (5) Clamp Body
CRIMP CONNECTION TO CONTACTS (162 SERIES)
Using the recommended tools, crimp the contacts to the wires and
insert them in the connector as described in the Amform instructions,
which are supplied with each 162 series assembly.
Bring up clamp body taking care not to drag the braid forward. (If
necessary a small amount of thin tape may be used to hold the braid
in position whilst carrying out this operation). Screw the clamp body
onto the connector accessory thread, making sure that the connector
serrations engage with those on clamp body. Fold the braid out at
right angles to the cable and slide forward the braid clamp. Smooth
back braid onto the braid clamp and trim off the surplus. Slide up
gasket, washer, screw on nut and tighten.
Surplus Braid
Trimmed
37
Assembly Instructions
FOR AMPHENOL STRAIGHT S.J. CLAMPS TO
DEF STAN 59-35 (Part 1) Sec. 3 FOR
INTERNALLY AND EXTERNALLY SCREENED AND UNSCREENED CABLES
EXTERNALLY SCREENED JACKETED CABLE TYPES ‘B & Q’
Cable and Wire Stripping
Strip the outer braid and internal P.V.C. jacket of the cable back to
dim ‘A’
A Dimension
Size mm in
08
10
12 & 14
16 & 20
24
33.32
34.93
39.70
42.85
47.63
1.312
1.375
1.563
1.687
1.875
FOR 162 SERIES
Strip 5.6mm (0.220 in) to 6.6mm (0.260 in) of insulation from
each wire taking care not to cut or nick strands. If ends fray
twist them back to their original lay.
INITIAL ASSEMBLY
Slide onto the cable the following items in this order (1) Nut (2)
Washer (3) Male Braid Clamp Convolute Screen (See B) as far
as possible, and slide on times (4) Female Braid Clamp (5)
Gasket and (6) Clamp Body
CRIMP CONNECTION TO CONTACTS (162 SERIES)
Using the recommended tools, crimp the contacts to the wires
and insert them in the connector as described in the Amform
instructions, which are supplied with each 162 series assembly.
Bring up clamp body and screw onto the connector accessory
thread, making sure that the connector serrations engage with
those on clamp body. Slide forward gasket and female braid
clamp. Push forward screen and fold out at right angles braid
which does not return to original position. Slide up male braid
clamp. Smooth back braid onto male braid clamp and trim off
surplus. Slide up washer. Screw on nut and tighten.
UNSCREENED JACKETED CABLES TYPE ‘A’
All procedures concerning this type of cable to be as for
internally screened jacketed cable but all references to screen
(Braid) to be disregarded.
Surplus Braid
Trimmed
38
Assembly Instructions
FOR AMPHENOL ANGLED S.J. CLAMPS TO
DEF STAN 59-35 (Part 1) Sec. 3 FOR
INTERNALLY AND EXTERNALLY SCREENED AND UNSCREENED CABLES
INTERNALLY SCREENED JACKETED CABLE TYPE ‘C’
Cable and Wire Stripping
Strip the outer P.V.C. jacket of the cable back to dim ‘A’ to expose the
internal braid. Trim the braid back to within 19.05mm (0.75 in) of
P.V.C. jacket and fold back ‘B’.
A Dimension
Size mm in
08
10/12 & 14
16
20
24
58.15
66.68
69.85
88.90
95.25
2.890
2.625
2.750
3.500
3.750
FOR 162 SERIES
Strip 5.6mm (0.220 in) to 6.6
mm (0.260 in) of insulation from each wire
taking care not to cut or nick strands. If ends fray twist them back to
their original lay.
INITIAL ASSEMBLY
Slide onto the cable the following items in this order (1) Nut (2) Washer
(3) Gasket (4) Braid Clamp (5) 75o Angled Body
CRIMP CONNECTION TO CONTACTS (162 SERIES)
Using the recommended tools, crimp the contacts to the wires and
insert them in the connector as described in the Amform instructions,
which are supplied with each 162 series assembly. Bring up clamp
body taking care not to drag the braid forward. (If necessary a small
amount of thin tape may be used to hold the braid in position whilst
carrying out this operation). Screw the clamp body onto the connector
accessory thread, making sure that the connector serrations engage
with those on the clamp body. Fold the braid out at right angles to the
cable and slide forward the braid clamp. Smooth back braid onto the
braid clamp and trim off the surplus. Slide up gasket, washer, screw
on nut and tighten.
Surplus Braid
Trimmed
39
Assembly Instructions
FOFOR AMPHENOL ANGLED S.J. CLAMPS TO
DEF STAN 59-35 (Part 1) Sec. 3 FOR
INTERNALLY AND EXTERNALLY SCREENED AND UNSCREENED CABLES
EXTERNALLY SCREENED JACKETED CABLES TYPES ‘B’ & ‘Q’
Cable and Wire Stripping
Strip the outer braid and internal P.V.C. jacket of the cable back to dim ‘A’.
A Dimension
Size mm in
08
10, 12 & 14
16
20
24
58.15
66.68
69.85
88.90
95.25
2.890
2.625
2.750
3.500
3.750
FOR 162 SERIES
Strip 5.6mm (0.220 in) to 6.6mm (0.260 in) of insulation from each wire
taking care not to cut or nick strands. If ends fray twist them back to their
original lay.
INITIAL ASSEMBLY
Slide onto the cable the following items in this order:
(1) Nut (2) Washer (3) Male Braid Clamp Convolute Screen (See B) as
far as possible and slide on items (4) Female Braid Clamp (5) Gasket
(6) 75o Right Angled Body
CRIMP CONNECTION TO CONTACTS (162 SERIES)
Using the recommended tools, crimp the contacts to the wires and insert
them in the connector as described in the Amform instructions, which are
supplied with each 162 series assembly. Bring up clamp body taking care
not to drag the braid forward. (If necessary a small amount of thin tape
may be used to hold the braid in position whilst carrying out this operation). Screw the clamp body onto the connector accessory
thread, making sure that the connector serrations engage with those on
the clamp body. Fold the braid out at right angles to the cable and slide
forward the braid clamp. Smooth back braid onto the braid clamp and trim
off the surplus. Slide up gasket, washer, screw on nut and tighten.
UNSCREENED JACKETED CABLES ‘TYPE A’
All procedures concerning this type of cable to be as for internally screened jacketed cable but all references to screen (Braid) to be
disregarded.
Surplus Braid
Trimmed
40
162GB
Assembly Instructions
WIRE STRIPPING 162GB SERIES
Strip 5.6mm (.220 in) to 6.6mm (.260 in) of insulation from end
of wire for both size 20 and 16 contacts taking care not to cut or
nick strands. If ends fray twist them back to their original lay.
CONTACT AND WIRE DATA 162GB SERIES
Suitable Wire Sizes Stripping
Lengths
Contact
Size Colour
Code Contact Part Nos A.W.G. in mm
Permissible Insulation
O.D. range for Grommet
Sealing in mm
20 RED Pin: 162GB-149-20000-05
Skt: 162GB-101-20000-05 20, 22, 24 0.032 0.020
0.81-0.51 0.047 0.085
1.19 - 2.16 0.220-0.260
5.6 - 6.6
16 BLUE Pin: 162GB-149-16000-05
Skt: 162GB-101-16000-05 16, 18, 20 0.051 0.032
1.295 0.81 0.066 0.109
1.675 2.77 0.220 0.260
5.6 6.6
CRIMP WIRE CONTACTS CRIMPING JAW SETTING
Contact Size Wire Size Crimp Jaw Setting
20
24
22
20
No. 2
No.3
No.4
Use Amphenol 294-542 Crimp Tool (M22520/1-01) with 294-1889-
01 Turret Head (M22520/1-
02). Release and rotate Turret Knob to
proper contact size (as per colour code) and lock adju
st Selector
Knob on handle to correct wire size [see table].
Insert stripped wire into Contact Pocket until it is visible through
inspection hole. Fully seat Contact in Crimp Tool Positioner and
close handles in one full stroke. (The Ratchet will not rel
ease until
tool has completed full stroke). Inspect Crimp for wire visibility
through Inspection Hole.
16 20
18
16
No. 4
No. 5
No. 6
CRIMPING WIRE TO CONTACT
CONTACT INSERTION
TABLE 1
Insertion Tool Part No.
Contact
Size Colour
Code Amphenol M.S.
Grommet Sealing
Plug
20 RED 294GB-5000-20 - 162GB-130-20000
16 BLUE 294-96 MS 24256A-16 162GB-130-16000
Select the proper insertion tool for the size of contact Table
1. The Insertion Tool and procedure are the same for both
pin and socket
contacts. Slide rear accessory and sleeve
over wire bundle. Lay wire in groove of insertion tool and
slide contact into front of tool until it is properly located in
tool probe. Insert contact into the correct hole in the rear
face of the grommet. Keep
ing contact in line with the axis
of the hole, apply a smooth even push on the tool until the
contact is fully seated in position. Note: it is essential that
the contact and tool are correctly aligned with the axis of
hole during insertion to prevent dam
age to contacts.
Withdraw tool at right angles to grommet surface until
complete free of connector. All contacts must be inserted
whether in circuit or not and the appropriate size sealing
plug used behind any contacts that are not wired. Push
the sealing plug in by hand until it is fully seated.
INSPECTION HOLE
41
TABLE 2
Removal Tool Part Number
Contact
Size Colour
Code Amphenol M.S.
20 RED 294-89 MS 24256R-20
16 BLUE 294-97 MS 25246R-16
Contact Size
CAUTION: extra care is required in this operation to prevent dama
ge
to the connector.
Remove the rear accessory and sleeve and slide back on wire bundle.
Select the proper removal tool for the size of contact from table 2. The
same tool is used for both pin and socket contacts. Position the
removal tool over the con
tacts to be removed and push until tool probe
is fully bottomed, shown when indicator band enters insert hole. Tool is
inserted to first band only when removing pin contacts and to the
second band for socket contact removal. Slide the plunger know
forward to remove contact.
Details of operator training are available from Amphenol upon request.
Indicator Band
CONTACT REMOVAL
CONTACT INSERTION
Amphenol Thanet Way, Whitstable, Kent. CT5 3JF Tel: 01227 773200 Fax: 01227 276571
Notice: Products are sold subject to Amphenol’s conditions of sale (“the standard conditions”). All specifications and statements co
ntained
herein are believed to be correct at the time of printing but no representation or warranty, express or implied, is given as to any specification or
statement contained herein. Product specifications including performance characteristics are typic
al only and subject to deviation. Specifications
are also subject to change without notice. Users should not assume that all safety measures are indicated or that other measures may not be
required. No representation or warranty, express or implied, is
given that any use of products (including any stated or suggested use) does not
infringe any patent, registered design or other third party rights and no stated or suggested use of products can be taken to recommend any such
infringement.