70
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54 / IP 68
Max. 360 m3/h
– Material: Housing: Die-cast aluminum
Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counterclockwise,
looking towards rotor
– Connection: Via single wires AWG 22,
TR 64
– Highlights: Housing with grounding lug for
screw M4 x 8 (Torx)
– Weight: 725 g
1) Fiberglass-reinforced plastic
Tin-plated
Finger guards
from p. 242
3 2 1 8 5 6 1 2 - 8 1
3 2 2 1 5 6 1 2 - 8 1
4 2 2 1 5 6 1 3 - 7 1
4 2 2 1 6 7 2 4 - 7 1
4 2 4 2 5 6 1 3 - 7 1
4 2 4 2 6 7 2 4 - 7 1
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm-1 °C Hours Hours
7212 N 360 212 12 6...15 53 6.2 12.0 3 050 -25...+72 80 000 / 37 500 135 000 ¿
7214 N 360 212 24 12...30 53 6.2 12.0 3 050 -25...+72 80 000 / 37 500 135 000 ¿
7218 N 360 212 48 24...60 53 6.2 12.0 3 050 -25...+72 80 000 / 37 500 135 000 ¿
Subject to change
Nominal voltage
Air flow
Air flow
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption*
Nominal speed
Temperature range
Service life L10 (40 °C)
ebm-papst standard
Service life L10 (Tmax)
ebm-papst standard
Life expectancy L10IPC
(40 °C) see page 17
Curve
* Power consumption at free air flow. These values can be significantly higher in the operating point.
DC axial fans
Ø 150 x 55 mm
Series 7200 N
Nominal data