TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Circuit Breaker for Equipment thermal, 2 pole, Push button actuation See below: Approvals and Compliances Description - Thermal circuit breaker 1 or 2 pole thermal overload protection Positively trip-free release High configurability Snap-in or flange mounted Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2) Applications - Power tools - Industrial appliances - Power supplies Weblinks pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News Technical Data Rated Voltage AC Rated Voltage DC Rated current range AC Conditional short circuit capacity Degree of Protection Dielectric Strength Insulation Resistance Lifetime AC 240 V 60 V 0.05 - 20 A IEC: Inc, PC1, AC 240 V: 1 kA from front side IP40 acc. to IEC 60529 4 kV 500 VDC > 100 M mechanical: 50'000 switching cycles AC: 1 x Ir: 50'000 switching cycles DC: 1 x Ir: 50'000 switching cycles Overload Allowable Operation Temp. Vibration Resistance Shock Resistance Tripping Type Actuation Type Weight AC: min. 40 trips @ 6 x Ir DC: min. 50 trips @ 4 x Ir -10 C to 55 C 0.75 mm @ 5 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc 30 G / 18 ms acc. to IEC 60068-2-27, test Ea Thermal Pushbutton 35 - 40 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: TA45 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40019880 UL Approvals UL UL File Number: E71572 CCC Approvals CCC CCC Certificate Number: 2013010307660082 Circuit Breakers 1 TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Dimension [mm] Snap-in type and quick connect terminal Snap-in type and screw clamp terminal 34 25 34 10.8 P1 a LINE 44.1 LINE 63 23.7 3 P1 a 5 3 5 10.6 26.7 5.3 26.9 5 18.5 6 59 50 6 Identification B) 10.8 A) 8.4 10.8 21.5 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm Flange type and quick connect terminal Flange type and screw clamp terminal 34 25 10.8 23.7 P1 a 3 LINE LINE 44.1 5 3 5 10.6 P1 a 5.3 26.7 8.4 A) B) 10.8 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm 2 10.8 21.5 Circuit Breakers B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm 32.2 63 43.3 39.3 4 13 6 6 74 50 TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Cut-out and pin-out Cut-out snap-in type b 44,5...45,0 44,5...45,0 44,7...45,2 44,7...45,2 44,8...45,3 44,9...45,4 45,0...45,5 4. 2 1.0 1.5 2.0 2.5 3.0 4.0 5.0 +0.2 b 50.5 -0.0 a 60 a (1.0 - 5.0) 21.7 - 0.0 +0.2 Cut-out flange type / Installation from rear 1) +0.2 25.2 -0.0 2) 1) Assemble 2) edge must be sharp Pin-out 4. 2 Cut-out flange type/ Installation from rear with AZZ05 cover b a +0.3 P1 52.5 -0.0 60 U-Relais P2 c 4 +0.3 27.5 -0.0 6 Circuit Breakers 3 5 3 TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Diagrams 1 pole thermal overload protection 1 pole thermal overload protection, Shunt terminal P2 6 P2 P1 3 6 2 pole thermal overload protection 3 5 2 pole thermal overload protection, Shunt terminal P2 P1 4 3 6 Effect of ambient temperature The units are calibrated for an ambient temperature of +23C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A, Environmental temperature = 40 C, --> Correction factor = 1.08, Resulting current = 5.5 A --> Fount to next higher rated current: 6 A 4 P1 Circuit Breakers P2 P1 4 3 5 TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Time-Current-Curves [ min ] [ sec ] 10'000 Type TA45 Rated current In <3 A 60 30 20 2000 Ambient temp. 1000 10 [ min ] [ sec ] 10'000 1 pole protected 2 pole protected 30 +23C 20 10 500 5 2000 2 pole protected Ambient temp. 1000 +23C 500 100 Time in Seconds 1 50 20 10 1 50 20 10 5 5 2 2 1 1 0,5 0,5 0,3 0,3 0,2 0,2 0,1 0,1 1,05 1,32 2 3 4 5 8 10 1,05 1,32 Multiple of Rated Current In Multiple of Rated Current In Reference Temperature +23 Reference Temperature +23 [ min ] [ sec ] 10'000 Type 2 3 4 5 8 10 TA45 In > 18 A Rated current 60 20 3 A > In <18 A 1 pole protected 200 100 30 TA45 5 200 Time in Seconds Type Rated current 60 1 pole protected 2000 2 pole protected Ambient temp. 1000 10 +23C 500 5 Time in Seconds 200 100 1 50 20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Reference Temperature +23 Config. Code TA45|-|AK2|W|F|120|A2|-|AZM11| The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function Circuit Breakers 5 TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 ABU 2-pole, push button, 1pole overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP65 ABV 2-pole, push button, 2pole overload protection, flat connection, snap-in type, push button gasket IP65 ABW 2-pole, push button, 2p overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP65 ABX 2-pole, push button, 1pole overload protection, screw connection, snap-in type, push button gasket IP40 AEL 2-pole, push button, 1p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP40 AEM 2-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP40 AEN 2-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP40 AEP 2-pole, push button, 1pole overload protection, screw connection, snap-in type, push button gasket IP65 AEU 2-pole, push button, 1p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP65 AEV 2-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP65 AEW 2-pole, push button, 2p overload protection, shunt terminal, screw connection, snap-in type, push button gasket IP65 AEX 2-pole, push button, 1pole overload protection, flat connection, flange type, push button gasket IP40 AHL 2-pole, push button, 1pole overload protection, shunt terminal, flat connection, flange type, push button gasket IP40 AHM 2-pole, push button, 2pole overload protection, flat connection, flange type, push button gasket IP40 AHN 2-pole, push button, 2p overload protection, shunt terminal, flat connection, flange type, push button gasket IP40 AHP 2-pole, push button, 1pole overload protection, flat connection, flange type, push button gasket IP65 AHU 2-pole, push button, 1pole overload protection, shunt terminal, flat connection, flange type, push button gasket IP65 AHV 2-pole, push button, 2pole overload protection, flat connection, flange type, push button gasket IP65 AHW 2-pole, push button, 2p overload protection, shunt terminal, flat connection, flange type, push button gasket IP65 AHX AJL 2-pole, push button, 1p overload protection, shunt terminal, screw connection, flange type, push button gasket IP40 AJM 2-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP40 AJN 2-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP40 AJP 2-pole, push button, 1pole overload protection, screw connection, flange type, push button gasket IP65 AJU 2-pole, push button, 1p overload protection, shunt terminal, screw connection, flange type, push button gasket IP65 AJV 2-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP65 AJW 2-pole, push button, 2p overload protection, shunt terminal, screw connection, flange type, push button gasket IP65 AJX 6 Circuit Breakers embossed Configuration key F H K L black printed M white printed I 0 P black printed I 0 R white printed black printed white printed ON I 0 OFF white printed 2-pole, push button, 1pole overload protection, screw connection, flange type, push button gasket IP40 TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour Legend I 2-pole, push button, 1pole overload protection, flat connection, snap-in type, push button gasket IP65 TA45|-|AK2|W| F |120|A2|-|AZM11| = Legend 0 ABP ON 2-pole, push button, 2p overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP40 V OFF ABN U Front Grey: Green/Red ON 2-pole, push button, 2pole overload protection, flat connection, snap-in type, push button gasket IP40 Front Yellow: Green/Red OFF ABM T I 2-pole, push button, 1pole overload protection, shunt terminal, flat connection, snap-in type, push button gasket IP40 Front Black: Green/Red 0 ABL Configuration key I 2-pole, push button, 1pole overload protection, flat connection, snap-in type, push button gasket IP40 Actuator colour 0 Configuration key S black printed ON I 0 OFF Basic function T TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current Rated current Configuration key 0.05 A Z05 0.1 A J01 0.2 A J02 0.3 A J03 0.4 A J04 0.5 A J05 0.6 A J06 0.7 A J07 0.8 A J08 0.9 A J09 1.0 A J10 1.1 A J11 1.2 A J12 1.3 A J13 1.4 A J14 1.5 A J15 1.6 A J16 1.7 A J17 1.8 A J18 Other rated currents on request TA45-2P Thermal (T- and TA-Line) https://www.schurter.com /PG17_20 Rated current Configuration key Rated current Configuration key 1.9 A J19 14.0 A 140 2.0 A J20 15.0 A 150 2.1 A J21 16.0 A 160 2.2 A J22 17.0 A 170 2.3 A J23 18.0 A 180 2.5 A J25 19.0 A 190 200 2.8 A J28 20.0 A 3.0 A 030 Other rated currents on request 3.5 A 035 4.0 A 040 4.5 A 045 5.0 A 050 6.0 A 060 6.5 A 065 7.0 A 070 7.5 A 075 8.0 A 080 9.0 A 090 10.0 A 100 11.0 A 110 12.0 A 120 13.0 A 130 TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch Release / lock-out latch Configuration key whithout release / lock-out latch C0 TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories Factory mounted accessories Configuration key Without cover For subsequent fitting accessories see: https://www.schurter.com/pdf/english/typ_TA45-ACC.pdf Other rated currents on request Variants Addition Thermal overload protection connection type Mounting IP Protection Class Front Side Actuator colour Legend Rated current Accessories Config. Code Order Number 2-pole Quick connect terminal Flange type IP65 Front Black: Green/Red white printed 20.0 A Without cover TA45-AHWTL200C0 4430.3513 2-pole Quick connect terminal Snap-in type IP40 Front Black: Green/Red embossed 12.0 A Without cover TA45-ABNTF120C0 4430.3516 1-pole Quick connect terminal Snap-in type IP65 Front Black: Green/Red black printed 10.0 A Without cover TA45-ABUTM100C0 4430.3608 Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging Unit 1 Pcs Accessories Description 31.05.2019 TA45-ACC Accessories to TA45 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Circuit Breakers 7