SPECIFICATION CONTROL DRAWING
Tyco Electronics Corporation
300 Constitution Drive,
Menlo Park, CA. 94025, U.S.A.
Raychem
TITLE:
Raychem Hi-Spec Flexible Bus Cable Joint
MIL-STD-1553B Lightweight System
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
DOCUMENT NO.:
D-150-9133
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
DOC. ISSUE:
1
DATE:
27-Sept-00
DRAWN BY:
M. FORONDA
CAGE CODE:
06090
REPLACES:
N/A
DCR NUMBER:
D000423
PROD. REV.:
F
SCALE:
None
SIZE:
A
SHEET:
1 of 2
If this document is printed it becomes uncontrolled. Check for the latest revision.
MATERIALS
1. SEALING SLEEVE: High temperature fluid stabilized cross-linked elastomer to Specification RK-6008.
Color: black.
2. MELTABLE RINGS: Modified stabilized elastomer-fluoropolymer thermoplastic.
3. BRAID: Solder impregnated, flux coated, tin plated copper wire braid.
SOLDER: TYPE Sn96 per ANSI J-STD-006.
FLUX: TYPE ROM1 per ANSI-J-STD-004.
4. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified
polyvinylidene fluoride.
5. SOLDER PREFORM:
SOLDER: TYPE Sn96 per ANSI J-STD-006.
6. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified
polyvinylidene fluoride.
7. CRIMP: Copper Alloy 102 per ASTM B75. Tin plated per MIL-T-10727 Type T. Red stripe code.
APPLICATION
1. This flexible cable joint is designed to facilitate the assembly or maintenance of pre-cabled digital harness
components for MIL-STD-1553B networks. It should be used where continuous flexing is not a
functional requirement.
2. Cables to be joined, Raychem 10612, 10613, 10614.
3. Minimum bend radius; Static: 80mm. Dynamic: not recommended.
4. Temperature range: -65°C to +150°C. Brief excursions to 200°C permissible without degradation.
5. Designed to meet performance requirements of Raychem Specification HPDS-0519.
6. For installation procedure and tooling, see RPIP-600-12.
DRAWN BY:
M. FORONDA
CAGE CODE:
06090
REPLACES:
N/A
DCR NUMBER:
D000423
PROD. REV.:
F
SCALE:
None
SIZE:
A
SHEET:
2 of 2
If this document is printed it becomes uncontrolled. Check for the latest revision.