KWD5 SPECIFICATIONS
NEMIC-LAMBDA
PA773-01-01
MODEL KWD5-1212 KWD5-1515
ITEMS
CH1
CH2
CH1
CH2
1 Nominal Output Voltage V+12 (24) -12 +15 (30) -15
2 Minimum Output Current A0.0 0.0 0.0 0.0
3 Maximum Output Current A0.22 0.22 0.18 0.18
4 Maximum Output Power W5.3 5.4
5 Efficiency (Typ) (*1) %69 69
6 Input Voltage Range (*2) -85 - 265VAC (47 - 440Hz) or 110 - 340VDC
7 Input Current (Typ) (*1) -0.2A at 100VAC
8 Inrush Current (Typ) -15A at 100VAC, 30A at 200VAC Ta=25°C
9 Output Voltage Range -Fixed ±5% (Max)
10 Maximum Ripple & Noise (*3) mV 150 150 150 150
11 Maximum Line Regulation (*3, *4) mV 60 60 75 75
12 Maximum Load Regulation (*3, *5) mV 600 600 750 750
13 Maximum Temperature Driff (*3, *6) mV 120 120 150 150
14 Over Current Protection (*7) -105% -
15 Over Voltage Protection (*8) -110% -
16 Parallel Operation - -
17 Series Operation -Possible
18 Hold-Up Time (Typ) -17mS at 5W, 100 VAC, Ta = 25°C
19 Operating Temperature --10 - +70°C (-10°C : 80%, 0 - +50°C : 100%, +70°C : 25%)
20 Operating Humidity -30 - 90%RH (No dewdrop)
21 Storage Temperature --30 - +85°C
22 Storage Humidity -20%RH - 95%RH (No dewdrop)
23 Cooling -Convection Cooling
24 Withstand Voltage -Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA),
Output - FG : 500VAC (100mA) for 1minute each.
25 Isolation Resistance -More than 100M
Ω
at 25°C and 70%RH Output - FG 500VDC
26 Vibration -10 - 55Hz, Constant Amplitude 1.65mm p-p (Max 10G),
sweep 1 minute X,Y,Z 1 hour each
27 Shock -Less than 50G for 11±5mS on ±(X, Y, Z) axis each 3 times
28 Safety -Approved by UL1950, CSA234, EN60950(TUV)
29 Conducted Radio Noise (*9) -Built to meet VCCI - Class B, FCC class B, VDE class B
30 Weight g 75
31 Size (WxHxD) mm 45 x 20.5 x 55
*Read instruction manual carefully, before using the power supply unit.
NOTES :
* 1 : At 100VAC and Maximum Output Power, Ta = 25°C.
* 2 : For cases where conformance to various safety specs (UL, CSA & TUV) are required, to be described
as 100 - 240VAC, 50 / 60Hz on name plate.
* 3 : Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage.
* 4 : From 85 - 265VAC, constant load.
* 5 : From Min load - Full load (Maximum power), constant input voltage.
* 6 : From 0 - +50°C, constant input voltage and load.
* 7 : Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
* 8 : Over Voltage Clamping by Zener Diode (on CH2 only).
* 9 : VDE class B with external capacitor. Measurement point for
output ripple & noise
( EIAJ RC-9002A probe )
-V
A
KWD
COM
+V
Bandwidth of scope : 100MHz
Measurement point for
Vo, load/line regulation Fig. A
L=50mm
C=0.1uF
Film Cap.
C=0.1uF
Film Cap.