DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
Outer jacket color will be white (designated by a “-9)" appended
to the part number, e.g. 5028D5312-9) unless otherwise
specied.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and sufxes may be added to
the part number, as necessary, to capture any additional
requirements imposed by the purchase order.
Users should evaluate the suitability of this product for their application. Specications are subject to change without notice. Tyco Electronics
Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication,
without notication to Buyer.
Page 1 of 1 Rayfoam, Thermorad, Cheminax, Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
© 2013 Tyco Electronics Corporation, All rights reserved.
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
Raychem Wire & Cable THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS
REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE
ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
DIELECTRIC
Rayfoam L
Color - Natural
CONDUCTOR
AWG 28, 7 Strands of
AWG 36, Silver-Coated
Copper
.0150
SPECIFICATION CONTROL DRAWING 5028D5312
CHEMINAX 50 OHM, AWG 28, 7 STRANDS OF AWG 36, TRIAXIAL CABLE Date 7-15-13
Revision E
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
2nd SHIELD
AWG 40,
Silver-Coated Copper
2nd JACKET
Thermorad F
CHARACTERISTIC IMPEDANCE 50 ± 2 ohms, Method A
CAPACITANCE 27.8 pF/ft. (nominal)
28.3 pF/ft. (maximum)
VELOCITY OF PROPAGATION 73% (nominal)
ATTENUATION 92.0 dB/100 ft. (maximum) at 4 GHz
ADDITIONAL REQUIREMENTS
ELECTRICAL
CONDUCTOR RESISTANCE 62.0 ohms/1000 ft. (nominal)
INSULATION RESISTANCE
CONDUCTOR TO SHIELD
10,000 megohms (minimum)
for 1000 ft.
JACKET FLAWS
SPARK TEST
IMPULSE TEST
1.0 kV (rms)
6.0 kV (peak)
VOLTAGE WITHSTAND
CONDUCTOR TO SHIELD
SHIELD TO SHIELD
750 volts (rms) (minimum)
500 volts (rms) (minimum)
ENVIRONMENTAL
FLAMMABILITY Method C
HEAT SHOCK 225°C
LOW TEMPERATURE-COLD BEND -55°C/3.00 inch mandrel
VOLTAGE WITHSTAND
(Post Environmental)
1000 volts (rms), 1 minute
PHYSICAL
INSULATION (DIELECTRIC)
ELONGATION
TENSILE STRENGTH
50% (minimum)
1000 lbf/in2 (minimum)
JACKET (EACH)
ELONGATION
TENSILE STRENGTH
100% (minimum)
2000 lbf/in2 (minimum)
JACKET THICKNESS (EACH) .008 inch (minimum)
.010 inch (nominal)
SHIELD COVERAGE (EACH) 90% (minimum)
WEIGHT 8.8 lbs/1000 ft. (nominal)
1st JACKET
Thermorad F
Color - White
1st SHIELD
AWG 40,
Silver-Coated Copper
.039
± .003
.052
.072
.085
.105
(nominal)
.110
(maximum)