Pressure Sensors Low Pressure Differential, Gage, Vacuum Gage/Amplified 160PC Series FEATURES 1 Low pressure measurement 1 PCB terminals on opposite side from the ports 1 Fully signal conditioned 160PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 0.01 VDC Excitation, 25C (Exception 163PC at 10 0.01 VDC Excitation, 25C) Min. Typ. Max. Units Excitation 6.00 8.00 16 VDC Supply Current --- 8.00 20 mA Current Sourcing Output --- --- 10 mA Null Offset (161/162/164PC) * 0.95 1.00 1.05 V Null Offset (163PC) * * 3.45 3.50 3.55 V Output at Full Pressure (161/162/164PC) 5.90 6.00 6.10 V Output at Full Vacuum (163PC) 0.80 1.00 1.20 V Span (161/162/164PC) 4.85 5.00 5.15 V Span (163PC)** --- 5.00 --- V Ratiometricity Error 7 to 8 V or 8 to 9 V 9 to 12 V ----- 0.50 2.00 ----- % Span Stability over One Year --- 0.50 --- % Span Response Time --- --- 1.00 msec Weight --- 28 --- grams Short Circuit Protection Output may be shorted indefinitely to ground Output Ripple None, DC device Ground Reference Supply and output are common * Positive (or negative) pressure measurement. * * Positive AND negative pressure measurement. ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40 to +85C (-40 to +185F) Storage Temperature -55 to +125C (-67 to +257F) Compensated Temperature -18 to +63C (0 to +145F) Shock MIL-STD-202, Method 213 (50 g, half sine, 6 msec) Vibration MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g) Media P2 port Wetted materials; polyester housing, epoxy adhesive, silicon, borosilicate glass,and silicon-toglass bond* P1 port Dry gases only * Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube bond. 38 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Pressure Sensors Low Pressure Differential, Gage, Vacuum Gage/Amplified 160PC Series 160PC SERIES ORDER GUIDE, VACUUM GAGE AND GAGE TYPE Combined Null & Sensitivity Shift (%Span) Linearity, B.F.S.L. Catalog Listing Pressure Range NH2O 25 to 5 25 to 45C 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/NH2O Overpressure psi Max. 161PC01D 0-27.68 --- 1.00 2.00 0.18 162PC01G 0-27.68 --- 1.00 2.00 0.18 P2 > P1 P2 < P1 %Span Repeatability & Hysteresis %Span Typ. Max. Max. 5 --- 1.00 0.15 Vacuum Gage 5 --- 1.00 0.15 Gage 160PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE Combined Null & Sensitivity Shift (%Span) Linearity, B.F.S.L. P2 > P1 P2 < P1 Repeatability & Hysteresis %Span Typ. Catalog Listing Pressure Range NH2O 25 to 5 25 to 45C 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/NH2O Overpressure psi Max. 162PC01D 0-27.68 --- 1.00 2.00 0.18 5 2.00 --- 0.15 163PC01D36 5 1.00 --- --- 0.50 5 2.00 1.00 0.25 %Span Max. Max. 164PC01D37 0-10 1.00 --- --- 0.50 5 2.00 --- 0.25 163PC01D75 2.5 1.25 --- --- 1.00 5 2.00 1.00 0.25 164PC01D76 0-5 1.25 --- --- 1.00 5 2.00 --- 0.25 160PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE @ 10 VDC 0.01 EXCITATION, 25C Combined Null & Sensitivity Shift (%Span) Linearity, B.F.S.L. 25 to 5 25 to 45C 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/cmH2O Overpressure cmH2O Max. 163PC01D48 -20 to +120 0.75* --- --- 0.36 350 P2 < P1 Max. Max. Repeatability & Hysteresis %Span Typ. 1.5 --- 0.15 %Span * Null shift. Span shift is 1.00/Span Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 39 Amplified Catalog Listing Pressure Range cmH2O P2 > P1 Pressure Sensors Low Pressure Differential, Gage, Vacuum Gage/Amplified 160PC Series INTERNAL CIRCUITRY NULL AND SENSITIVITY TEMPERATURE SHIFT Amplified pressure sensor are 100% tested to insure that the maximum null and sensitivity temperature shift does not exceed the specification. The diagram below illustrates how null and sensitivity shift relates to temperature. Note that the maximum shift occurs at temperature extremes. Therefore, if a sensor is not ex- posed to the entire temperature range, the maximum null and sensitivity shift will actually be less than the value specified. This diagram indicates the temperature shift pertaining to a few listings. Maximum null and sensitivity shift varies from listing to listing. NOTES 1. Terminals are labeled on the sensor. 2. Input and output share a common ground. 3. RL must be greater than or equal to 3000 ohms. RATIOMETRICITY Ratiometricity refers to the output voltage being directly proportional to supply voltage. 160PC sensors in this catalog are calibrated at 8 VDC supply voltage (except 163PC) to provide a 1-6 volt (5 V Span) output swing. For example, if supply increases by 50% to 12 VDC, the output voltage increased by 50% to 1.5-9 volts (7.5 V Span). SCALING OF 160PC SERIES SENSORS WITH 8V EXCITATIONS NOTE The output is not perfectly ratiometric. See Accuracy specifications for the degree of error. 161PC01D Vacuum Gage VO J 1 V at 0 psig & 6 V at -1 psig 162PC01D Differential VO J 1 V at 0 psig & 6 V at 1 psig VO J 1 V at -5N H2O & 6 V at -5N H2O NOTE: 161PC sensors are scaled for greater pressure on the P1 side of the chip. 162PC sensors are scaled for greater pressure on the P2 side of the chip. Other scalings available upon request. 163PC01D36 Differential 40 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Pressure Sensors Low Pressure Differential, Gage, Vacuum Gage/Amplified 160PC Series MOUNTING DIMENSIONS (For reference only) 160PC CONSTRUCTION Amplified Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 41