Pressure Sensors 160PC Series
Low Pressure Differential, Gage, Vacuum Gage/Amplified
38 Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-800-737-3360 Canada
FEATURES
1
Low pressure measurement
1
PCB terminals on opposite side from
the ports
1
Fully signal conditioned
160PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 ±0.01 VDC
Excitation, 25°C(Exception163PC at10 ±0.01 VDC Excitation, 25°C)
Min. Typ. Max. Units
Excitation 6.00 8.00 16 VDC
Supply Current --- 8.00 20 mA
Current Sourcing Output --- --- 10 mA
Null Offset (161/162/164PC)* 0.95 1.00 1.05 V
Null Offset (163PC)** 3.45 3.50 3.55 V
Output at Full Pressure (161/162/164PC) 5.90 6.00 6.10 V
Output at Full Vacuum (163PC) 0.80 1.00 1.20 V
Span (161/162/164PC) 4.85 5.00 5.15 V
Span (163PC)** --- 5.00 --- V
Ratiometricity Error
7to8Vor8to9V --- ±0.50 --- %Span
9to12V --- ±2.00 ---
Stability over One Year --- ±0.50 --- %Span
Response Time --- --- 1.00 msec
Weight --- 28 --- grams
Short Circuit Protection Output may be shorted indefinitely to ground
Output Ripple None, DC device
Ground Reference Supply and output are common
*Positive (or negative) pressure measurement.
**Positive AND negative pressure measurement.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –40°to +85°C (–40°to +185°F)
Storage Temperature –55°to +125°C (–67°to +257°F)
Compensated Temperature –18°to +63°C(0°to +145°F)
Shock MIL-STD-202, Method 213 (50 g, half sine, 6 msec)
Vibration MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g)
Media P2 port Wetted materials; polyester housing, epoxy
adhesive, silicon, borosilicate glass,and silicon-to-
glass bond*
P1 port Dry gases only
*Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube
bond.
Pressure Sensors 160PC Series
Low Pressure Differential, Gage, Vacuum Gage/Amplified
Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-800-737-3360 Canada 39
160PC SERIES ORDER GUIDE, VACUUM GAGE AND GAGE TYPE
Combined Null & Sensitivity Shift
(%Span) Linearity, B.F.S.L.
25 to 5°25 to –18°25 to –40°P2 >P1 P2 <P1
25 to 45°C25to+63°C 25to85°C %Span
Catalog
Listing
Pressure
Range
NH
2
O Max. Max. Max. Sensitivity
V/NH
2
O
Overpressure
psi
Max. Max. Max.
Repeatability
& Hysteresis
%Span
Typ.
161PC01D 0-27.68 --- ±1.00 ±2.00 0.18 5 --- ±1.00 ±0.15 Vacuum
Gage
162PC01G 0-27.68 --- ±1.00 ±2.00 0.18 5 --- ±1.00 ±0.15 Gage
160PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE
Combined Null & Sensitivity Shift
(%Span) Linearity, B.F.S.L.
25 to 5°25 to –18°25 to –40°P2 >P1 P2 <P1
25 to 45°C25to+63°C 25to85°C %Span
Catalog
Listing
Pressure
Range
NH
2
O Max. Max. Max. Sensitivity
V/NH
2
O
Overpressure
psi
Max. Max. Max.
Repeatability
& Hysteresis
%Span
Typ.
162PC01D 0-27.68 --- ±1.00 ±2.00 0.18 5 ±2.00 --- ±0.15
163PC01D36 ±5±1.00 --- --- 0.50 5 ±2.00 ±1.00 ±0.25
164PC01D37 0-10 ±1.00 --- --- 0.50 5 ±2.00 --- ±0.25
163PC01D75 ±2.5 ±1.25 --- --- 1.00 5 ±2.00 ±1.00 ±0.25
164PC01D76 0-5 ±1.25 --- --- 1.00 5 ±2.00 --- ±0.25
160PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE @10 VDC ±0.01 EXCITATION, 25°C
Combined Null & Sensitivity Shift
(%Span) Linearity, B.F.S.L.
25 to 5°25 to –18°25 to –40°P2 >P1 P2 <P1
25 to 45°C25to+63°C 25to85°C %Span
Catalog
Listing
Pressure
Range
cmH
2
O Max. Max. Max. Sensitivity
V/cmH
2
O
Overpressure
cmH
2
O
Max. Max. Max.
Repeatability
& Hysteresis
%Span
Typ.
163PC01D48 –20 to +120 ±0.75* --- --- 0.36 350 ±1.5 --- ±0.15
*Null shift. Span shift is ±1.00/Span
Amplified
Pressure Sensors 160PC Series
Low Pressure Differential, Gage, Vacuum Gage/Amplified
40 Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-800-737-3360 Canada
INTERNAL CIRCUITRY
NOTES
1. Terminals are labeled on the sensor.
2. Input and output share a common
ground.
3. RLmust be greater than or equal to
3000 ohms.
RATIOMETRICITY
Ratiometricityrefersto the output voltage
being directly proportional to supply volt-
age. 160PC sensors in this catalog are
calibrated at 8 VDC supply voltage (ex-
cept 163PC) to provide a 1-6 volt (5 V
Span) output swing. For example, if sup-
ply increases by 50% to12 VDC, the out-
put voltage increased by 50% to 1.5-9
volts (7.5 V Span).
NOTE
The output is not perfectly ratiometric.
See Accuracy specifications for the de-
gree of error.
NULL AND SENSITIVITY
TEMPERATURE SHIFT
Amplified pressure sensor are 100%
tested to insure that the maximum null
and sensitivity temperature shift does not
exceed the specification. The diagram
below illustrates how null and sensitivity
shift relates to temperature. Note that the
maximum shift occurs at temperature ex-
tremes. Therefore, if a sensor is not ex-
posed to the entire temperature range,
the maximum null and sensitivity shift will
actually be less than the value specified.
Thisdiagramindicatesthetemperature
shiftpertainingtoafewlistings.Maximum
null and sensitivity shift varies from listing
to listing.
SCALING OF 160PC SERIES SENSORS WITH 8V EXCITATIONS
161PC01D Vacuum Gage VOJ1Vat0psig&6Vat–1psig
162PC01D Differential VOJ1Vat0psig&6Vat1psig
163PC01D36 Differential VOJ1Vat–5NH
2
O&6Vat–5NH
2
O
NOTE:161PC sensors are scaled for greater pressure on the P1 side of the chip.162PC sensors
arescaled forgreater pressureon theP2 sideof thechip. Otherscalings availableupon request.
Pressure Sensors 160PC Series
Low Pressure Differential, Gage, Vacuum Gage/Amplified
Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-800-737-3360 Canada 41
MOUNTING DIMENSIONS (For reference only)
160PC CONSTRUCTION
Amplified