2 of 8
RF1156
DS110802
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter Rating Unit
VDD, V1, V2, V3 6.0 V
Maximum Input Peak Power
Momentary Infrequent Occurance
27 at 1:1 VSWR
24 at 6:1 VSWR
dBm
Maximum Continuous Power (PAR <4) 23 at 1:1 VSWR
20 at 6:1 VSWR
dBm
Operating Temperature -30 to +90 °C
Storage Temperature -65 to +125 °C
Parameter Specification Unit Condition
Min. Typ. Max.
Operating Characteristics
Active Mode:VHIGH>1.8V,VLOW <0.4V;
VDD=2.75V; Temp=25°C; PIN =16dBm unless
otherwise specified.
Insertion Loss
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT
0.40 0.55 dB 450MHz to 960MHz
0.45 0.60 dB 960 MHz to 1710 MHz
0.55 0.75 dB 1710 MHz to 1990 MHz
0.65 0.85 dB 1990 MHz to 2500 MHz
0.65 0.95 dB 2500 MHz to 2690 MHz
Isolation
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT
26 30 dB 450MHz to 960MHz
21 24 dB 960 MHz to 1710 MHz
20 22 dB 1710 MHz to 1990 MHz
19 21 dB 1990 MHz to 2500 MHz
18 21 dB 2500 MHz to 2690 MHz
Return Loss
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT
18 20 dB 450MHz to 2690MHz, All RF ports in Insertion
Loss state.s
Harmonics
Second Harmonic (2F0)7083 dBcF
0=880MHz
70 84 dBc F0=1880MHz
Third Harmonic (3F0)7079 dBcF
0=880MHz
70 75 dBc F0=1880MHz
IIP2
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT (Cell)
103.5 106 dBm Tone 1: 824MHz @ 16dBm, Tone 2: 1693MHz
@ -20dBm, Receive Freq: 869MHz
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT (AWS)
100 108 dBm Tone 1: 1710MHz @ 16dBm, Tone 2:
3820MHz @ -20dBm, Receive Freq: 2110MHz
RF1-ANT, RF2-ANT, RF3-ANT,
RF4-ANT, RF5-ANT (PCS)
100 108 dBm Tone 1: 1850 MHz @ 16dBm, Tone 2:
3780MHz @ -20dBm, Receive Freq: 1930MHz
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EU Directive2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.