Digital Fiber Amplifier E3X-DA-N CSM_E3X-DA-N_DS_E_7_2 Note: Manufacturing of the E3X-DA@TW Series was discontinued at the end of March 2012. Manufacture of the E3X-DA11-N/DA41-N/DA11D/DA6/DA8/DA6D will be discontinued in March 2017. The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance Be sure to read Safety Precautions on page 23. UL991* * UL certification including UL 991 testing and evaluation * Applicable standards: UL 3121-1 * Additional application testing and evaluations standards: UL 991 and SEMI S2-0200S Features Models with New Connector System Reduces Wiring, Saves Space, and Makes Maintenance Easier First in the Industry Patent Pending In Amplifiers with wire-saving connectors, the power supply is distributed to 1-conductor slave connectors through a 3conductor master connector. This design has three major advantages. 1. Wiring time is significantly reduced. 2. Relay connectors are unnecessary, so wiring takes up less space and costs are reduced. 3. Storage and maintenance are simpler because it isn't necessary to distinguish between master connector and slave connectors on the Amplifier. Super Digital Display with Auto Power Control (APC) Circuit First in the Industry The passage of time causes the intensity of the Sensor's lightemitting LED elements to deteriorate, which may make stable detection impossible. The E3X-DA-N is the first series of Fiber Sensors to use an Auto Power Control (APC) circuit. This achieves strict detection by eliminating fluctuation in the digital value and is ideal for subtle detection such as stable detection of liquidcrystal glass. Incident level 3000 Simplified Connector Design Up to 16 Amplifiers can be connected. Previous Digital Fiber Amplifiers Threshold Unstable detection Time Incident level 3000 Optical communications Power supply pin Master connector E3X-DA-N Series Threshold Stable detection Slave connector Time 1 E3X-DA-N Power Consumption Reduced by As Much As 70% Digital Display Can Be Turned OFF or Dimmed during Operation Eco-mode Power consumption is reduced by as much as 70% from 1800 mW to 600 mW (when the digital display is OFF). When the digital display is viewed infrequently during operation, current consumption can be reduced by dimming the display or turning it OFF entirely. (Eco-mode can be set from the Mobile Console only.) 1800 mW 600 mW Previous model This eco-label is displayed on products that meet environmental standards established by OMRON. E3X-DA-N (with digital display OFF) New Generation of Mobile Consoles the Size of Cellular Phones. Further Developing the Ultimate Power of Fiber Amplifiers. Remote Setting and Adjustment Perform settings, teaching, and fine adjustments at the end of the Fiber Unit. Previously, settings and teaching could be performed only on the Amplifier. Now, however, using a Mobile Console enables these operations at the end of the fiber. Strict adjustments can be made while checking the workpiece position. With group teaching, teach multiple amplifiers simultaneously. The tedious teaching that had to be performed separately for each Amplifier can now be performed for several Amplifiers at once using the Mobile Console. Group teaching Eliminate inconsistency by using group zero reset. Display the light intensity and threshold at the same time. New Concept The group zero reset function can simultaneously reset the digital displays of multiple Amplifiers to 0. This function is useful to minimize variation between Amplifier values. Patent Pending Flash the Sensor head and display the amplifier channels during operation. Function indicator section Channel setting section Even if the Amplifier and Sensor head are separated during operation, it is still possible to flash the Sensor head and display the amplifier channels. Light intensity monitor Channel 5 Threshold Channel 4 Channel 3 Channel 2 Operation keys Channel 1 Battery monitor Head Optical communications 2 E3X-DA-N Ordering Information Amplifiers Pre-wired Amplifiers Type Appearance Standard models Control output ON/OFF output * ON/OFF output * Monitor output Monitor-output models Mark-detecting models (blue LED) Mark-detecting models (green LED) Infrared models Differential-output model *1 Water-resistant models Model NPN output PNP output E3X-DA11-N 2M *2 E3X-DA41-N 2M *2 E3X-DA21-N 2M E3X-DA51-N 2M E3X-DAB11-N 2M E3X-DAG11-N 2M E3X-DAH11-N 2M E3X-DA11D 2M *2 E3X-DAB41-N 2M E3X-DAG41-N 2M E3X-DAH41-N 2M --- E3X-DA11V 2M E3X-DA41V 2M E3X-DA11TW 2M *2 E3X-DA41TW 2M *2 ON/OFF output Twin-output models *1. For details, refer to page 6. *2. Manufacturing of the E3X-DA@TW Series was discontinued at the end of March 2012. Manufacture of the E3X-DA11-N/DA41-N/DA11D will be discontinued in March 2017. Amplifiers with Standard Connectors Type Standard models Monitor-output models Mark-detecting models (Blue LED) Mark-detecting models (Green LED) Infrared models Differential-output model *1 Water-resistant models (M8 connector) Appearance Applicable Connector (order separately) Master Slave Master Slave Master Slave Master Slave Master Slave Master Slave E3X-CN11 E3X-CN12 E3X-CN21 E3X-CN22 E3X-CN11 E3X-CN12 E3X-CN11 E3X-CN12 E3X-CN11 E3X-CN12 E3X-CN11 E3X-CN12 XS3F-M421-40@-A XS3F-M422-40@-A Master Control output Model NPN output PNP output ON/OFF output E3X-DA6 *2 E3X-DA8 *2 * ON/OFF output * Monitor output E3X-DA7 E3X-DA9 E3X-DAB6 E3X-DAB8 E3X-DAG6 E3X-DAG8 E3X-DAH6 E3X-DAH8 E3X-DA6D *2 ON/OFF output E3X-DA14V E3X-DA44V E3X-CN21 E3X-DA6TW Twin-output models E3X-DA8TW *2 Slave --- *2 E3X-CN22 *1. For details, refer to page 6. *2. Manufacturing of the E3X-DA@TW Series was discontinued at the end of March 2012. Manufacture of the E3X-DA6/DA8/DA6D will be discontinued in March 2017. 3 E3X-DA-N Amplifier Connectors (Order Separately) Note: Seal provided as accessory. Type Appearance Cable length No. of conductors Master Connector Model 3 E3X-CN11 4 E3X-CN21 1 E3X-CN12 2 E3X-CN22 2m Slave Connector Combining Amplifiers and Connectors (Basically Amplifiers and Connectors are sold separately.) Refer to the following tables when placing an order. Amplifiers Type Standard models NPN E3X-DA6 E3X-DAB6 Mark-detecting models E3X-DAG6 Infrared models E3X-DAH6 Differential-output model E3X-DA6D Monitor-output models E3X-DA7 Twin-output models E3X-DA6TW PNP E3X-DA8 E3X-DAB8 E3X-DAG8 E3X-DAH8 --E3X-DA9 E3X-DA8TW Applicable Connectors (Order Separately) Master Connector Slave Connector + E3X-CN11 E3X-CN12 E3X-CN21 E3X-CN22 1 Master Connector 4 Slave Connectors When Using 5 Amplifiers Amplifiers (5 Units) + Sensor I/O Connectors (Order Separately) Size Cable specifications Appearance Cable type XS3F-M421-402-A 2m M8 Standard cable Straight connector 5m 2m L-shaped connector 5m Model 4-wire connection XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A 4 E3X-DA-N Mobile Console (Order Separately) Appearance Model Remarks Mobile Console with head, cable, and AC (model number of set) adapter provided as accessories. E3X-MC11 Power supply method: chargeable battery E3X-MC11-C1 Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1.5 m) Accessories (Order Separately) Operating Instructions Sticker Mounting Brackets Appearance Applicable model E3X-DA-N Series Model Quantity Model E39-Y1 E39-L143 1 E3X-DA@V Remarks --- E39-L148 * When using a Through-beam Fiber Unit, order one Bracket for the Receiver and one for the Emitter. Remarks Attach near the Sensor. Refer to page 25. End Plate Appearance Model Quantity PFP-M 1 5 E3X-DA-N Ratings and Specifications For dimensions, refer to page 26 to 29. Amplifiers Pre-wired Amplifiers Output type Item Monitoroutput models Type Standard models NPN output E3X -DA11-N E3X -DA21-N E3X -DAB11-N PNP output E3X -DA41-N E3X -DA51-N E3X -DAB41-N Infrared models Waterresistant models Twin-output models E3X -DAG11-N E3X -DAH11-N E3X -DA11V E3X -DA11TW E3X -DAG41-N E3X -DAH41-N E3X -DA41V E3X -DA41TW Mark-detecting models Light source (wavelength) Red LED (660 nm) Power supply voltage 12 to 24 VDC10%, ripple (p-p) 10% max. Power consumption Normally: 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Eco Mode: 720 mW max. (current consumption: 30 mA max. at power supply voltage of 24 VDC) Digital display not lit: 600 mW max. (current consumption: 25 mA max. at power supply voltage of 24 VDC) Control output ON/OFF output Monitor output Protection circuit Super-highspeed mode ReStandard sponse mode time Super-longdistance mode Sensitivity setting Functions Blue LED (470 nm) Green LED (525 nm) Infrared LED (870 nm) Red LED (660 nm) Load current: 50 mA (residual voltage (NPN/PNP): 1 V max., Open collector (NPN or PNP output, depending on the model) Light ON/Dark ON selectable --- Load 1 to 5 VDC, 10 k min. --- Power supply reverse polarity, Output short-circuit protection, Mutual interference prevention (supported for up to 10 Units) 0.25 ms for operation and reset respectively 0.5 ms for operation and reset respectively 1 ms for operation and reset respectively 2 ms for operation and reset 4 ms for operation and reset respectively 7 ms for operation and reset respectively Teaching or manual method Timer function OFF-delay timer: 0 to 200 ms, 1 to 20 ms (set in 1-ms units); 20 to 200 ms (set in 5-ms units) Using Mobile Console: OFF delay, ON delay, or one shot (selectable) Automatic power control (APC) Fiber-optic current digital control Zero-reset Negative values can be displayed. Initial reset Settings can be returned to defaults as required. Monitor focus Upper and lower limits can be set as required for every 100 digital values. --- --- Fiber-optic current digital control --- Indicators Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level percentage display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-segment digital threshold display (red) Display timing Switching between normal/peak-hold/bottom-hold possible Display orientation Switching between normal/reverse possible Optical axis adjustment Optical axis adjustment possible (hyper-flashing function) Ambient illumination (receiver side) Incandescent lamp: 10,000 lx max. Sunlight: 20,000 lx max. 6 E3X-DA-N Output type Item Monitoroutput models Type Standard models NPN output E3X -DA11-N E3X -DA21-N E3X -DAB11-N PNP output E3X -DA41-N E3X -DA51-N E3X -DAB41-N Infrared models Waterresistant models Twin-output models E3X -DAG11-N E3X -DAH11-N E3X -DA11V E3X -DA11TW E3X -DAG41-N E3X -DAH41-N E3X -DA41V E3X -DA41TW IEC IP66 (with Protective Cover attached) IEC IP50 (with Protective Cover attached) Approx. 110 g Approx. 100 g Mark-detecting models Ambient temperature Operating:Groups of 1 to 3 Amplifiers: -25 to 55C Groups of 4 to 11 Amplifiers: -25 to 50C Groups of 12 to 16 Amplifiers: -25 to 45C Storage:-30 to 70C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 M min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and Z directions Shock resistance (destruction) 500m/s2, for 3 times each in X, Y and Z directions Degree of protection IEC IP50 (with Protective Cover attached) Connection method Pre-wired (standard cable length: 2 m) Weight (packed state) Approx. 100 g Material Case Polybutylene terephthalate (PBT) Cover Polycarbonate Accessories Polyethersulfo ne Instruction sheet Amplifiers with Connectors (Specifications different to those for Pre-wired Amplifiers) Output type Item Type Standard models Monitor-output models NPN output E3X-DA6 E3X-DA7 E3X-DAB6 PNP output E3X-DA8 E3X-DA9 E3X-DAB8 Infrared models Waterresistant models* Twin-output models E3X-DAG6 E3X-DAH6 E3X -DA14V E3X -DA6TW E3X-DAG8 E3X-DAH8 E3X -DA44V E3X -DA8TW Mark-detecting models Connection method Standard connector M8 connector Standard connector Weight (packed state) Approx. 55 g Approx. 65 g Approx. 55 g * The dielectric strength for water-resistant models is 500 VAC at 50/60 Hz for 1 min. Connectors Mobile Console Model Item E3X-CN11/21/22 E3X-CN12 Rated current 2.5 A Rated voltage 50 V Contact resistance 20 m max. (20 mVDC max., 100 mA max.) The figure is for connection to the Amplifier and the adjacent Connector. It does not include the conductor resistance of the cable. No. of insertions (durability) 50 times The figure for the number of insertions is for connection to the Amplifier and the adjacent Connector. Material Housing Contacts Weight (packed state) Polybutylene terephthalate (PBT) Item Model E3X-MC11 Power supply voltage Charged with AC adapter Connection method Connected via adapter Weight (packed state) Approx. 580 g (Console only: 120 g) Refer to Instruction Manual provided with the Mobile Console for details. Phosphor bronze/gold-plated nickel Approx. 55 g Approx. 25 g 7 E3X-DA-N Digital Fiber Amplifiers with Differential Outputs (E3X-DA11D/E3X-DA6D) Characteristics of Applicable Fiber Units Through-beam Fiber Units Sensing distance (mm) (The figures in parentheses apply when using the 39-F1 Lens Unit.) Sensitivity selection HIGH 11-level setting 1 Response time 270 or 570 s Fiber Unit LOW 2 3 to 11 0.5 or 1 ms 1 to 200 ms or 2 to 400 ms 1 270 or 570 s 2 3 to 11 0.5 or 1 ms 1 to 200 ms or 2 to 400 ms Standard object (mm) *1 (min. sensing object *2: opaque) E32-T11R 240 (1680) 280 (1960) 370 (2590) 140 (980) 180 (1260) 240 (1680) E32-T21R 50 60 80 30 40 50 E32-T16WR 580 690 910 350 450 580 (0.3 dia.) *1 E32-T16PR 380 450 600 230 290 380 (0.2 dia.) *2 1 dia. (0.01 dia.) *1. These values are for sensing objects that are moving. *2. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating temperature. (The value is for sensing objects that are moving.) *3. The values given in the above table are those that can be detected at a digital value of 1,000 in each sensing area. Reflective Fiber Units Sensing distance (mm) *1 Sensitivity selection HIGH 11-level setting Response time Fiber Unit 1 270 or 570 s LOW 2 3-11 0.5 or 1 ms 1 to 200 ms or 2 to 400 ms 1 270 or 570 s 2 3-11 0.5 or 1 ms 1 to 200 ms or 2 to 400 ms Standard object (mm) *2 (min. sensing object *3: opaque) E32-D11R 80 90 120 45 60 80 150 x 150 (0.01 dia.) E32-D21R 13 15 20 7 10 13 25 x 25 (0.01 dia.) *1. Sensing distances are given for white paper. *2. These values are for sensing objects that are moving. *3. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating temperature. (The value is for sensing objects that are moving.) Differences Compared with E3X-DA-N Amplifier Differential-output Models (Edge-detection Models) Type Item NPN output Pre-wired Wire-saving connector E3X-DA11D E3X-DA6D Current consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Control output Load current: 50 mA max., (Residual voltage: 1 V max. for NPN/PNP output) Open collector Switchable between Light ON (ON at edge detection) and Dark ON (OFF at edge detection) ON/OFF output Detection mode Switchable between single edge and double edge detection mode Response time Single edge: Can be set to 270 s, 500 s, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, or 200 ms. Double edge: Can be set to 570 s, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms or 400 ms. Functions Timer functions Light ON: OFF-delay timer, Dark ON: ON-delay timer 0 to 5 s (1 to 20 ms: 1-ms units, 20 to 200 ms: 5-ms units, 200 ms to 1 s: 100 ms, 1 to 5 s: 1-s units) APC Yes Zero-reset Yes (Negative values can be displayed.) Initial reset Yes (Settings can be returned to defaults.) Sensitivity selection Yes (HIGH/LOW) Teaching level One-point teaching level can be varied from 1% to 50% in increments of 1% Indicators Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital detection level display (red) For other information, refer to the instruction manual supplied with the product. 8 E3X-DA-N Engineering Data (Reference Value) E3X-DA-N/E3X-DA@V/E3X-DA@TW X 600 Y 400 200 0.5 1 1.5 2 2.5 3 3.5 -400 High speed -600 Super-long distance 400 Standard 200 1 -800 2 3 Super-high speed -400 Y 400 200 0 0.4 0.8 1.2 Super-high speed -200 1.6 Standard 600 X Y 400 200 Standard 0 1 2 3 100 0.2 0.4 0.6 0.8 1 1.2 -200 High speed Super-long distance X Super-long distance Y Standard 0 -200 -400 Standard 10 20 40 Super-high speed 0.4 0.8 60 80 100 120 1.2 1.6 2 2.4 Distance X (m) Super-long distance X 300 Y 200 100 0.2 0.4 -100 0.6 0.8 Super-high speed High speed 80 X Y Standard 100 200 300 400 500 Distance X (mm) -50 20 0 50 100 150 200 250 300 350 Distance X (mm) Standard -60 Super-long distance 150 High speed Super-long distance Super-high speed X Y 100 50 0 -50 -100 -200 Y 40 Through-beam E32-T14LR 50 -150 X Super-high speed 60 -80 100 -800 1.4 Distance X (m) Super-long distance -40 150 -600 1.2 Standard -20 Super-long distance 200 0 1 -300 140 160 Distance X (mm) Through-beam E32-T22B 400 200 20 -40 Distance Y (mm) Distance Y (mm) 600 Y -30 Through-beam E32-T11 800 X 30 -20 Super-long distance 5 Through-beam E32-T22R -10 Standard 4 Distance X (m) -400 40 0 1.4 -300 Super-high speed 3 -200 Distance X (m) -100 2 400 0 5 Distance Y (mm) Y 200 -400 4 Distance X (m) -200 Distance Y (mm) Distance Y (mm) X 300 1 -800 Through-beam E32-T21R 400 0 -200 -600 -600 Through-beam E32-T12R High speed 200 Through-beam E32-T11R Super-long distance -600 Standard -400 Super-long distance -400 -400 Y 400 Through-beam E32-TC200 + E39-F1 (separately sold Long-distance Lens Unit) 2 Distance X (m) X 600 Distance Y (mm) X 800 5 -800 600 0 4 Distance X (m) -200 -600 Standard Through-beam E32-TC200 Distance Y (mm) Y 0 4 Distance X (m) X 600 Distance Y (mm) 0 -200 800 Distance Y (mm) Distance Y (mm) 800 Distance Y (mm) Distance Y (mm) Parallel Operating Range At maximum sensitivity. (Use for optical axis adjustment at installation.) Through-beam Through-beam Through-beam E32-T11L E32-T11L + E39-F1 (separately sold E32-T12L Long-distance Lens Unit) 100 200 300 400 Standard 500 600 Distance X (mm) -100 Super-long distance -150 9 E3X-DA-N 40 X 30 Y 20 10 Super-high speed 80 120 160 -20 Standard Super-long distance -40 Y 300 200 100 0.4 0.6 0.8 1 -100 High speed -400 -500 1.2 Super-long distance -400 Standard Y 40 Standard 20 2 3 4 Distance X (m) High speed Super-long distance Y 100 50 Standard 1 80 Y 40 Standard 1 2 3 4 High speed Super-long distance Distance X (m) X 100 Y Standard 50 Super-high speed 1 2 High speed Distance Y (mm) Standard 50 0 1 2 3 4 -50 -100 High speed Super-long distance -200 50 X 100 Y 50 -50 3 4 Standard 1 2 3 4 5 Distance X (m) -50 Standard -100 Super-long distance -200 Y 50 5 Distance X (m) -100 2 High speed 3 4 5 Distance X (m) 200 -150 Super-long distance Standard Y 100 50 0 1 2 3 4 5 -50 -150 Super-long distance X 150 -100 -150 2 High speed X Super-high speed 100 Through-beam E32-T16PR 150 1 150 0 1 -50 Distance Y (mm) Distance Y (mm) Through-beam E32-T16P -100 Y -150 -150 0 X 100 0 5 Distance X (m) 6 Super-long distance -150 Distance Y (mm) 100 150 5 -100 Super-long distance Distance Y (mm) Y 4 Distance X (m) Through-beam E32-T16JR 150 3 -50 Through-beam E32-T16J 200 5 150 0 5 -120 X 4 Distance X (m) Through-beam E32-T16J 200 3 -50 -150 X -40 -60 2 -200 -80 -80 X 150 Through-beam E32-T16WR -40 Super-long distance 200 0 High speed 0 5 2 -800 5 120 X 60 1.6 Super-long Standard distance High speed -100 Distance Y (mm) Distance Y (mm) 4 Through-beam E32-T16W 80 -20 3 -600 Through-beam E32-T24S 1.2 Distance X (m) -600 Distance X (m) -200 0.8 Through-beam E32-T22S Standard 2 0.4 -400 400 1 200 0 Y 0 Y 400 -200 X 200 X 600 700 800 Super-long distance 600 800 Distance X (mm) 500 600 Standard Distance X (m) -200 1 400 High speed -100 Distance Y (mm) Distance Y (mm) X 0 200 300 Through-beam E32-T61 + E39-F1 (separately sold Long-distance Lens Unit) 500 400 -300 100 -300 Through-beam E32-T61 0.2 100 -200 -30 0 200 200 Distance X (mm) Y Distance Y (mm) 40 X Distance Y (mm) 0 300 0 -10 Through-beam E32-T51 Distance Y (mm) Through-beam E32-T81R Distance Y (mm) Distance Y (mm) Through-beam E32-T24R -200 Standard Super-high speed Distance X (m) Super-long distance 10 E3X-DA-N Y 20 10 0 100 200 300 -20 X Y 100 Super-long distance Standard 50 0 400 100 Distance X (mm) -10 150 Distance Y (mm) X Standard Super-high speed 200 300 500 400 Distance X (mm) -50 -150 X Y 60 40 20 100 400 200 -20 -40 -60 Super-high speed Standard -80 -100 Distance Y (mm) 4 2 -8 -10 X Standard Super-high speed Y 4 2 0 6 10 30 40 60 10 20 30 40 50 Distance X (mm) -2 Super-long distance X High speed Y 1 2 3 4 5 4 2 20 60 40 80 100 Distance X (mm) Super-long Super-high speed Standard distance 20 X Standard 15 Y 10 5 0 20 40 60 80 100 120 140 Distance X (mm) -5 -15 Super-long distance -20 20 X Standard Y 10 5 0 20 40 60 80 100 Distance X (mm) -10 High speed Super-long distance 30 X Y 20 10 Standard 0 -10 20 40 High speed 60 80 100 Distance X (mm) -20 -30 Super-long distance High speed Reflective E32-C41 Reflective E32-C31 Distance Y (mm) Distance Y (mm) Y -4 6 Standard -0.6 Reflective E32-D22B -20 X -10 -8 -15 Super-long distance High speed -2 Distance X (mm) -0.2 -0.4 Super-long distance -6 -5 500 Reflective E32-D21B -4 15 400 6 -8 -10 0.2 0 300 10 8 -6 High speed 0.6 0.4 200 Distance X (mm) 0 80 90 Distance X (mm) 50 20 70 Reflective E32-D331 8 6 Y -6 Reflective E32-D33 X -4 Super-long distance 100 Reflective E32-D22R Standard -2 Distance X (mm) 300 10 8 0 500 10 -20 Distance Y (mm) 0 20 -10 Distance Y (mm) Distance Y (mm) 100 80 Reflective E32-D21R Distance Y (mm) Distance Y (mm) Reflective E32-D12R Y 30 -40 -50 High speed -30 X Standard -30 -100 Super-long distance 50 40 0 600 Distance Y (mm) 30 Distance Y (mm) Distance Y (mm) Operating Range With standard sensing object at maximum sensitivity. (Use for the positioning of the object and Sensor.) Reflective Reflective Reflective E32-D21L E32-DC200 E32-D11R 12 Y 4 High speed 0 10 20 30 40 50 60 Distance X (mm) -4 -8 Super-long distance X 8 Standard Super-long distance -12 11 E3X-DA-N Y High speed 4 0 20 10 30 40 50 -8 Standard Super-long distance Distance Y (mm) Reflective E32-D24 10 40 20 X Standard 15 Y 10 5 20 -20 40 80 60 100 10 8 High speed High speed Reflective E32-D36P1 X 2 20 30 40 -4 Super-high speed Distance Y (mm) Y 100 50 200 100 300 400 500 600 Distance X (mm) -50 High speed -150 Standard Super-long distance -200 50 80 120 160 200 Distance X (mm) Standard Super-long distance Standard 120 Y Standard 40 0 60 X 80 100 200 400 -40 -80 500 Distance X (mm) 300 High speed Super-long distance -120 Reflective E32-L56E@ X Standard Y 80 40 0 200 100 -40 300 500 400 High speed 600 Distance X (mm) -80 -120 Super-high speed 40 -10 Super-long distance 120 X 5 -5 Distance X (mm) Reflective E32-D36P1 150 10 Reflective E32-D61 -8 -10 Super-long distance Y 15 -20 -25 Super-long distance 10 X 20 -15 4 -2 25 0 240 Distance X (mm) 6 0 120 Distance X (mm) -20 -100 200 Y -6 0 160 -10 -10 -15 80 120 Reflective E32-D24R -5 Distance Y (mm) 20 -40 0 Y -30 -12 200 Standard 0 60 Distance X (mm) -4 X 30 Distance Y (mm) 8 40 Distance Y (mm) X Reflective E32-D14LR Super-long distance Distance Y (mm) 12 Distance Y (mm) Reflective E32-D32 Distance Y (mm) Distance Y (mm) Reflective E32-C42 2.0 X 1.5 Y 1.0 0.5 0 -0.5 4 8 12 16 20 24 Distance X (mm) -1.0 -1.5 -2.0 Distance Y (mm) Limited Reflective E32-L25L 1 0.5 0 -0.5 -1 2 4 6 8 Distance X (mm) 10 Y X X 12 E3X-DA-N Super-long distance 10 5 3 Standard Oper- 1 ating level 0.5 0.3 0 0.4 10 5 3 Super-long distance Oper1 ating level 0.5 0.3 Super-high speed 0.1 100 50 30 0.8 1.2 1.6 2 100 200 300 400 500 Y X 10 0.02-mm -dia. copper wire 5 0 10 20 700 800 30 0.1-mm -dia. copper wire 40 -5 50 50 100 150 200 250 25 Distance Hysteresis ON OFF Standard -20 Super-long distance Super-high speed 5 0 100 X 80 70 Super-high speed ON 60 50 Standard 40 30 20 Super-long distance 10 200 350 400 100 Sensing object: White paper 90 Sensing object: White paper 20 300 Distance (mm) Repeat Accuracy vs. Sensing Distance Reflective E32-DC200 10 0.4-mm-dia. copper wire -15 30 15 60 Distance X (mm) -10 0 Distance (mm) Hysteresis vs. Sensing Distance Reflective E32-D11L 15 600 Standard Super-high speed 0.1 0 Hysteresis (mm) Distance Y (mm) Operating Range Reflective E32-DC200 Super-long distance 10 5 3 0.1 Distance (m) 20 100 50 30 Oper1 ating level 0.5 0.3 Standard Super-high speed 1,000 500 300 Repeat accuracy (mm) 100 50 30 1,000 500 300 Excess gain ratio (times) 1,000 500 300 Excess gain ratio (times) Excess gain ratio (times) Excess Gain Ratio vs. Distance With standard sensing object at maximum sensitivity. Through-beam Reflective Reflective E32-TC200 E32-DC200 E32-D21L 300 400 500 Distance (mm) 0 20 40 60 80 100 Distance X (mm) E3X-DA-N Monitor output (V) Monitor output (V) Monitor Output vs. Distance (Standard Mode) Through-beam Reflective E32-TC200 E32-DC200 6 5 4 6 5 4 3 3 2 2 1 1 0 50 100 150 200 250 300 Distance (mm) 0 10 20 30 40 50 60 70 80 90 100 Distance (mm) 13 E3X-DA-N E3X-DAB-N/E3X-DAG-N 80 X 60 Y 40 20 0 Distance Y (mm) Distance Y (mm) Parallel Operating Range At maximum sensitivity. (Use for optical axis adjustment at installation.) Through-beam Through-beam E32-TC200 E32-TC200 + E39-F1(separately sold Long-distance Lens Unit) Superlong distance Standard Super-high speed 50 100 150 200 X 150 Y 100 50 0 250 Distance X (mm) -20 200 0.5 1 1.5 2 -40 -100 -60 -150 -80 -200 2.5 Distance X (m) -50 Super-high speed Standard Super-long distance X 30 Y 20 10 0 -10 60 20 80 40 100 5 Super-long distance -5 -15 Super-long distance -40 Y 10 -10 Super-high speed Standard X 15 0 Distance X (mm) -20 -30 20 60 20 80 40 X 30 Y 20 10 0 100 Distance X (mm) 40 Super-high speed Distance Y (mm) 40 Distance Y (mm) Distance Y (mm) Operating Range With standard sensing object at maximum sensitivity. (Use for the positioning of the object and Sensor.) Reflective Reflective Limited Reflective E32-DC200 E32-CC200 E32-D11L -10 -20 Standard -30 -20 80 100 120 60 20 Distance X (mm) 40 Super-high speed Standard Super-long distance -40 E3X-DAH-N X 150 Y 100 50 0 Super-high speed 0.2 Standard Super-long distance 0.4 0.6 8.0 X 300 Y 200 Super-long distance 100 0 1 Distance X (m) -50 400 Super-high speed Standard 0.4 0.8 1.2 1.6 200 Distance Y (mm) 200 Distance Y (mm) Distance Y (mm) Parallel Operating Range At maximum sensitivity. (Use for optical axis adjustment at installation.) Through-beam Through-beam Through-beam E32-TC200 E32-T11L E32-T14 Y 100 Standard Super-long distance 50 Super-high speed 0 2 Distance X (m) -100 X 150 1 2 3 -100 -200 -100 -150 -300 -150 -200 -400 -200 4 5 Distance X (m) -50 X 30 20 10 0 -10 Y Standard Super-high speed 40 80 120 160 200 Distance X (mm) -20 -30 -40 Super-long distance 80 Distance Y (mm) 40 Distance Y (mm) Distance Y (mm) Operating Range With standard sensing object at maximum sensitivity. (Use for the positioning of the object and Sensor.) Reflective Reflective Limited Reflective E32-DC200 E32-D11L E32-CC200 X 60 Y 40 20 0 -20 80 160 320 240 Super-high -40 speed Standard Super-long distance -60 -80 400 Distance X (mm) 50 40 X Y 30 20 10 0 -10 -20 -30 -40 -50 40 80 200 120 160 Super-high speed Standard Super-long distance Distance X (mm) For other information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 14 E3X-DA-N (In the following examples, threshold 1 is set to 3,000, and threshold 2 is set to 1,000.) Technical Reference (for E3X-DA-TW Twin-output Models) Output Patterns for Normal Operation Outputs 1 and 2 can be set to operate independently and either Light ON mode or Dark ON mode can be selected (independently) for channels 1and 2 making a total of 4 possible output patterns. Threshold 1: Dark ON Threshold 2: Light ON 4000 Threshold 1 1000 Threshold 2 0 Output 1 Output 2 Output 1 Threshold 1: Light ON Threshold 2: Dark ON ON OFF ON Output 2 OFF Output 1 ON inside threshold area Time ON Threshold 1 Threshold 2 3000 Threshold 1 1000 Threshold 2 Output 1 Threshold 1 Time ON OFF ON Output 2 OFF 4000 1000 ON OFF ON Output 2 OFF Output 1 3000 ON outside threshold area 0 Time 4000 0 4000 Incident level Incident level 0 Threshold 2 Threshold 1: Dark ON Threshold 2: Dark ON 4000 1000 1000 OFF ON Output 2 OFF OFF 3000 Threshold 1 0 Time ON OFF ON 3000 Incident level 3000 Incident level Incident level 4000 Threshold 2 Time Incident level Threshold 1: Light ON Threshold 2: Light ON Output Patterns for Area Sensing This series includes models equipped with area sensing functionality, a first for Digital Fiber Amplifiers. This functionality can be used to monitor whether the incident level is inside or outside the threshold area. The 2 output patterns below are possible for this kind of operation. 3000 Threshold 1 1000 Threshold 2 0 Time ON OFF ON Output 2 OFF Output 1 Note: Output 2 is always OFF. 15 E3X-DA-N I/O Circuit Diagrams NPN Output Model E3X-DA11-N E3X-DAB11-N E3X-DAG11-N E3X-DAH11-N E3X-DA11V E3X-DA6 E3X-DAB6 E3X-DAG6 E3X-DAH6 E3X-DA14V Operation mode Timing charts Light-ON Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black) Mode selector switch Output circuit Operation indicator (orange) L-ON (LIGHT ON) Dark-ON 12 to 24 VDC T D-ON (DARK ON) * Connector Pin Arrangement (M-8 Connector only) L-ON (LIGHT ON) Dark-ON Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black) D-ON (DARK ON) Light-ON CH1/ Incident light CH2 No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black) L-ON (LIGHT ON) E3X-DA11TW E3X-DA6TW Dark-ON CH1/ Incident light CH2 No incident light Operation ON indicator OFF (orange) ON Output transistor OFF 2 1 4 3 Note: Pin 2 is not used. Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black) E3X-DA21-N E3X-DA7 Blue 3 Operate Load (e.g., relay) Reset (Between brown and black) Light-ON Black Load Control output 4 Photoelectric Sensor main circuit Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Brown 1 Display Operation indicator (orange) Brown Display Photoelectric Sensor main circuit 47 Load Black Control output Orange Monitor * output Load 1 to 5 V Blue 12 to 24 VDC * Load resistance: 10 k min. Operation indicator (orange) Display Operation indicator (orange) Brown Black Load Control output 1 Load Orange Control output 2 Photoelectric Sensor main circuit T 12 to 24 VDC Blue D-ON (DARK ON) Operate Load (e.g., relay) Reset (Between brown and black) Note: With E3X-DA@TW models, only channel 1 is output when set for area sensing operation. LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. (Channel 2 is always OFF.) Sensor I/O Connectors for Models with M8 Connectors 4 3 2 1 Wire colors Brown White Blue Black 1 2 3 4 XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Classification Wire colors DC Brown White Blue Black Connection pin No. 1 2 3 4 Application Power supply (+V) --Power supply (0 V) Output Note: Pin 2 is not used. 16 E3X-DA-N PNP Output Operation mode Model E3X-DA41-N E3X-DAB41-N Light-ON E3X-DAG41-N E3X-DAH41-N E3X-DA41V E3X-DA8 E3X-DAB8 E3X-DAG8 E3X-DAH8 Dark-ON E3X-DA44V Timing charts Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Load (e.g., relay) Mode selection switch Output circuit Operation indicator (orange) T Display Photoelectric Sensor main circuit Operate Reset (Between blue and black) Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Brown 1 L-ON (LIGHT ON) 4 Control output Black 12 to 24 VDC Load 3 Blue T D-ON (DARK ON) * Connector Pin Arrangement (M-8 Connector only) Note: Pin 2 is not used. Operate Load (e.g., relay) Reset (Between blue and black) 2 4 1 3 Incident light Light-ON E3X-DA51-N E3X-DA9 Dark-ON Light-ON E3X-DA41TW E3X-DA8TW Dark-ON No incident light Operation ON indicator OFF (orange) T ON OFF Operate Load (e.g., relay) Reset (Between blue and black) Output transistor Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black) CH1/ Incident light CH2 No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black) CH1/ Incident light CH2 No incident light Operation ON indicator OFF (orange) Output transistor L-ON (LIGHT ON) Operation indicator (orange) Photoelectric Sensor main circuit Control output Black 47 Monitor output Load 1 to 5 V 12 to 24 VDC Orange Load * D-ON (DARK ON) Blue * Load resistance: 10 k min. L-ON (LIGHT ON) Operation indicator (orange) Display Operation indicator (orange) Brown Control output 1 Black Control output 2 Photoelectric Sensor main circuit 12 to 24 VDC Load Orange Load T D-ON (DARK ON) ON OFF Brown Display Blue 3 Operate Load (e.g., relay) Reset (Between blue and black) Note: With E3X-DA@TW models, only channel 1 is output when set for area sensing operation. LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. (Channel 2 is always OFF.) Sensor I/O Connectors for Models with M8 Connectors 4 3 2 1 Wire colors Brown White Blue Black 1 2 3 4 XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Classification Wire colors DC Brown White Blue Black Connection pin No. 1 2 3 4 Application Power supply (+V) --Power supply (0 V) Output Note: Pin 2 is not used. 17 E3X-DA-N Connection Connection with K3NX-VD2@ Process Meter K3NX-VD2@ 10 11 12 13 14 15 16 17 Monitor output Orange +V Brown 0 V Blue 12 VDC, 80 mA* 1 2 3 4 5 6 7 8 9 12 to 24 VDC E3X-DA-N Note 1. Various I/O Units are available for the K3NX. Select an appropriate output type depending on the application. 2. This wiring is for the K3NX with DC power supply specifications and the Monitor (Analog) Sensor with DC power supply specifications. Check respective power supply specifications before wiring. * Use this service power supply for the Sensor with reference to the power consumption of each Sensor. Nomenclature Amplifiers Standard, Monitor-output, Mark-detecting, Infrared, and Water-resistant Models Lock Button Level Display Operation Indicator ON when output is ON. OFF when output is OFF. Setting Buttons TEACH MODE Operating Mode Selector Use to switch between Light ON and Dark ON modes. Mode Selector Use to select SET, ADJ, or RUN mode. Twin-output Models Lock Button Level Display Operation Indicator ON when output is ON. Setting Buttons TEACH MODE Channel-selection Switch Use to switch between channels 1 and 2. Mode Selector Use to select SET, ADJ, or RUN mode. 18 E3X-DA-N Amplifier Adjustments All Models 1 Changing the Display (RUN Mode) 2 Digital incident level (4000 max.) Set the mode selector to RUN. Zero-reset (RUN Mode) Set the mode selector to RUN. Digital incident level (4000 max.) RUN RUN (Factory-set to RUN) TEACH * To reset to zero again: MODE 2s 1s TEACH 1s Digital percent To return the initial digital incident level: TEACH MODE Hold down both for 3 s. *There is no limit on the number of times zero-reset can be used. MODE 2s Analog incident level and threshold 3 Initial Reset (SET Mode) Set the mode selector to SET. SET MODE 2s TEACH Manual Tuning (Fine Sensitivity Adjustment) in ADJ Mode Perform fine sensitivity adjustment after teaching and manual tuning (without using the teaching function) in the way shown below: Twin-output Models MODE Hold down both for 5 s. TEACH MODE MODE First, select the channel to be adjusted using the channel Cancel selection switch. CH1 Execute initial reset CH2 Set the mode selector to ADJ. Fine sensitivity adjustment TEACH MODE ADJ Sensitivity increment with threshold decrement Sensitivity decrement with threshold increment The items displayed in ADJ mode vary with the display setting in RUN mode. RUN mode Digital incident level Digital percent Analog value ADJ mode Digital threshold Digital percent Analog value 19 E3X-DA-N 4 Setting Functions in SET Mode Set mode selector to SET. Four types of sensitivity settings are available. Refer to page 22 for details. Teaching SET Digital incident level display MODE Sensing function 2s Available with: E3X-DA21-N E3X-DA51-N E3X-DA7 E3X-DA9 Displayed as "F." Monitor Focus Standard (factory-set) TEACH B A Super-long distance TEACH MODE 2s Super-high speed Setting upper limit Alternates between for monitoring "A-UP" and setting value. TEACH (Factory setting) Alternates MODE Timer function 2s Displayed as "t." TEACH 0 (Factory-set) In units of 100 from 4,000. Alternates TEACH Adjustable in 1-ms units for 0 to 20 ms and in 5-ms units for 25 ms or higher. TEACH 200 Alternates TEACH MODE Flashing setting 2s Displayed as "L." TEACH Alternates OFF (Factory-set) TEACH TEACH Note: It is not possible to set an upper limit that is lower than the lower limit. ON TEACH MODE MODE Hold setting 2s Displayed as "H." OFF (Factory-set) Setting lower limit Alternates between for monitoring "A-LO" and setting value. (Factory setting) Alternates TEACH TEACH In units of 100 from 0 Peak Alternates TEACH Bottom TEACH TEACH Alternates MODE Display orientation setting Reversing display 2s TEACH Standard (factory-set) Alternates TEACH TEACH Reverse B A TEACH Note: It is not possible to set an lower limit that is lower than the lower limit. 20 E3X-DA-N Twin-output Models 4 Setting Functions (SET Mode) Set mode selector to SET. Four types of sensitivity settings are available. Refer to page 22 for details. Teaching SET Digital incident level display A B Setting the operating mode Changing the operating mode The operating mode for the channel set with the channel-selection switch can be changed. MODE Timer function 2s Displayed as "t." Changed using the channel-selection switch CH1 Channel 1 L-ON (Factory setting) CH2 TEACH Channel 2 Adjustable in 1-ms units for 0 to 20 ms and in 5-ms units for 25 ms or higher. 200 L-ON TEACH (Factory setting) (Factory setting) TEACH TEACH MODE Flashing setting 2s D-ON Displayed as "L." D-ON OFF (factory-set) TEACH MODE Sensing function 2s Displayed as "F." ON TEACH Standard (factory-set) MODE TEACH Hold setting 2s Displayed as "H." Super-long distance OFF (factory-set) TEACH TEACH Super-high speed Peak TEACH TEACH Area Bottom TEACH B A TEACH MODE 2s Area Sensing Area sensing is possible using the threshold values for channels 1 and 2. * If channel 1 is set to L-ON, output turns ON when the incident level is between the thresholds. * If channel 1 is set to D-ON, output turns OFF when the incident level is between the thresholds. The result is output to control output 1. (Control output 2 is always OFF.) Display orientation setting Reversing display Standard (factory-set) TEACH Reverse TEACH 21 E3X-DA-N All Models Teaching (SET Mode) * The four types of teaching given below are available. * Once the setting is made, the Amplifier operates according to the settings. The red level display will flash if a teaching error occurs. In that case, repeat the whole teaching procedure. With twin-output models, switch to the channel to be adjusted using the channel-selection switch. Maximum Sensitivity Setting 1 2 3 4 CH2 SET Set the mode selector to SET to start teaching. Step CH1 Two-point With/Without-object Teaching Operation Step Set the mode selector to SET. SET Press the TEACH button for at least 3 seconds. Setting is complete when the level display changes from red to green. The level display will display the digital incident level later. Operation 1 Set the mode selector to SET. 2 Press the TEACH button for approximately 1 second when the object is at the sensing position. SET TEACH 3s (Red) Object TEACH 1s (Green) Set to RUN mode. RUN 3 The red level display is lit. 4 Press the TEACH button for approximately 1 second with no object. (Red) One-point Without-object Teaching Step 1 Operation Set the mode selector to SET. SET TEACH 1s 2 Press the TEACH button for approximately 1 second. 5 Teaching is complete when the green level display is lit.The level display will display the digital incident level later. 6 Set to RUN mode. (Green) RUN TEACH 1s 3 4 5 Teaching is complete when the red level display is lit. The level display will display the digital incident level later. (Red) Note: The order of "with-object" and "without-object" setting steps above can be reversed. Pin-point Teaching (for Positioning) Step Set to RUN mode. RUN The threshold is automatically set with the object. Object Operation 1 Set the mode selector to SET. 2 Press the TEACH button for approximately 1 second with no object. SET TEACH 1s Out- ON put 3 The red level display is lit. 4 Place the object in the desired position, and press the TEACH button for at least 3 seconds. (Red) Note: If one-point teaching is not available because the difference in level is too fine, try two-point teaching. Operating Mode Selector Operating mode Light-ON L-ON Dark-ON D-ON Operation (Factory-set) L Object TEACH 3s D 5 Teaching is complete when the green level display is lit. The level display will display the digital incident level later. (The red level display will flash if a teaching error occurs.) 6 Set to RUN mode. Note: There is no operating mode selector for twin-output models. (Green) RUN 22 E3X-DA-N Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Insertion position Lock button Amplifiers Designing Operation after Turning Power ON The Sensor is ready to detect within 200 ms after the power supply is turned ON. If the Sensor and load are connected to separate power supplies, be sure to turn ON the Sensor first. Mounting Joining and Separating Amplifiers Joining Amplifiers (1) Mount the Amplifiers one at a time onto the DIN track. (2) Slide the Amplifiers together, line up the clips, and press the Amplifiers together until they click into place. Clip Fiber Connection and Disconnection The E3X Amplifier uses a one-touch locking mechanism. (Only the E3X-NM uses a locking button mechanism.) Connect or disconnect the fibers to or from the E3X Amplifier using the following procedures: (1) Connection Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier, and lower the lock button. Click into place Fiber Fiber insertion mark 10.7 mm (2) Disconnection Remove the protective cover and raise the lock button to pull out the fiber. Protective cover Locked Unlocked Note: To maintain the fiber properties, confirm that the lock is released before removing the fiber. (3) Precautions for Fiber Connection/Disconnection Be sure to lock or unlock the lock button within an ambient temperature range between -10 and 40C. Mounting the Mobile Console Head Leave a gap of at least 20 mm between the nearest Amplifier and the Mobile Console head. 20 mm Separating Amplifiers Slide Amplifiers away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifiers from the DIN track without separating them first.) Note 1. The specifications for ambient temperature will vary according to the number of Amplifiers used together. For details, refer to Ratings and Specifications. 2. Always turn OFF the power supply before joining or separating Amplifiers. Mounting the Mobile Console Head With Twin-output models (E3X-DA@@TW), up to 16 channels (i.e., eight E3X-DA@@TW Amplifiers) can be set using the E3X-MC11 Mobile Console. (Operating modes and area detection, however, cannot be set.) Adjustment Mutual Interference Protection Function There may be some instability in the digital display values due to light from other sensors. If this occurs, decrease the sensitivity (i.e., increase the threshold) to perform stable detection. EEPROM Writing Error If the data is not written to the EEPROM correctly due to a power failure during teaching or static-electric noise, repeat the whole teaching procedure. 23 E3X-DA-N Optical Communications Several Amplifiers can be slid together and used in groups. Do not, however, slide the Amplifiers or attempt to remove any of the Amplifiers during operation. Hysteresis Adjustment The hysteresis setting can be adjusted using the Mobile Console. Do not, however, set the hysteresis to a value lower than the factory setting. Using a setting less than the factory setting may result in incorrect operation. The clip can also be removed using the following mechanism, which is incorporated in the construction of the section underneath the clip. (1) Insert the clip to be removed into the slit underneath the clip on another Amplifier. Amplifiers with Connectors Mounting Mounting Connectors (1) Insert the Master or Slave Connector into the Amplifier until it clicks into place. (2) Remove the clip by rotating the Amplifier. Rotate Insert (2) Join Amplifiers together as required after all the Master and Slave Connectors have been inserted. (3) Attach the stickers (provided as accessories) to the sides of Master and Slave Connectors that are not connected to other Connectors. Sticker When using the E3X-DA-N with the Mobile Console, mount the End Plate in the way shown below. Sticker Note: Attach the stickers to the sides with grooves. End Plate Removing Connectors (1) Slide the slave Amplifier(s) for which the Connector is to be removed away from the rest of the group. (2) After the Amplifier(s) has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifiers first.) Pull Strengths for Connectors (Including Cables) E3X-CN11, E3X-CN21, E3X-CN22: 30 N max. E3X-CN12: 12 N max. Press down Lever Remove Mounting End Plate (PFP-M) Depending on how it is mounted, an Amplifier may move during operation. In this case, use an End Plate. Before mounting an End Plate, remove the clip from the master Amplifier using a nipper or similar tool. Clip 24 E3X-DA-N Accessories Operating Instructions Sticker E39-Y1 * Attach near the Sensor. * 1 English and 1 Japanese sticker per set * Material: Front side: Paper, Reverse side: Adhesive tape Japanese Sticker 100 62 English Sticker 100 62 25 E3X-DA-N (Unit: mm) Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet. Dimensions Pre-wired Amplifiers E3X-DA11-N E3X-DA21-N E3X-DAB11-N E3X-DA41-N E3X-DA51-N E3X-DA11D With Mounting Bracket Attached E3X-DAG11-N E3X-DAH11-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N *2 Operation indicator 3 Two, 2.4 dia. 4.9 x 3 = 14.7 Incident level indicator Threshold level indicator a *1 17.15 13.05 64.3 10 38.6 5.3 Mounting Holes Two, M3 31.5 8 9.9 10.7 16 10.75 Hole for optical communications 4.1 10.3 16 22.4 13 Two, 3.2-dia. holes 2.4 4 34.8 Mounting Bracket (E39-L143) (order separately) SUS304 stainless steel 3.4 4.4 22.4 *1. The Mounting Bracket can also be used on side A. *2. E3X-DA11-N/DA41-N/DAB11-N: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2; Insulationdiameter: 1.1 mm). Standard length: 2 m. E3X-DA21-N/DA51-N: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2; Insulation diameter:1.1 mm). Standard length: 2 m. 16 Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. Pre-wired Amplifiers, Water-resistant Models E3X-DA11V E3X-DA41V With Mounting Bracket Attached 4.9 x 3 = 14.7 30.05 25.95 Incident level indicator Threshold level indicator Operation indicator *2 a *1 81.5 Two, 2.4 dia. 6.9 12 40 2.8 33 8 9.9 11.2 10.7 3.9 3.4 16 23.9 14.4 4.3 37 67.2 11.5 Mounting Holes Two, M3 16 23.9 3.4 Hole for optical communications 6.6 Mounting Bracket (E39-L148) (order separately) 5.4 SUS304 stainless steel 16 5.4 3.4 *1. The Mounting Bracket can also be used on side A. *2. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). Standard length: 2 m. 26 E3X-DA-N Pre-wired Amplifiers, Twin-output Models E3X-DA11TW E3X-DA41TW With Mounting Bracket Attached *2 Operation indicator 3 Two, 2.4 dia. 4.9 x 3 = 14.7 Incident level indicator Threshold level indicator a *1 17.15 13.05 64.3 10 38.6 5.3 Mounting Holes Two, M3 31.5 8 9.9 10.7 16 10.75 3.4 10.3 E39-L143 Mounting Bracket (order separately) SUS304 stainless steel 3.4 Amplifiers with Standard Connectors E3X-DA6 E3X-DAG6 E3X-DA7 E3X-DAH6 E3X-DA8 E3X-DAB8 E3X-DA9 E3X-DAG8 E3X-DAB6 E3X-DAH8 E3X-DA6D E3X-DA6-P 10 4.4 22.4 *1. The Mounting Bracket can also be used on side A. *2. 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). Standard length: 2 m. 16 Incident level indicator Threshold level indicator Operation indicator 13.05 17.15 Two, 2.4 dia. 2.4 4 34.8 Two, 3.2-dia. holes Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. Hole for optical communications 16 22.4 13 4.9 x 3 = 14.7 3 64.3 31.5 8 14 9.9 10.7 5.5 3.4 1.8 38.6 13 36.7 5.1 3.9 Hole for optical communications 1.8 1.7 4.2 6.2 1.7 Dimensions with Master Connector Connected 71 67.5 64.3 Dimensions with Slave Connector Connected 31.5 1.5 1.8 5.1 3.9 71 67.5 E3X-CN11: 4.0 dia. E3X-CN21: 4.0 dia. E3X-CN02: With no cable E3X-CN12: 2.6 dia. E3X-CN22: 4.0 dia. E3X-CN02: With no cable 64.3 31.5 1.5 12.95 4 10 1.8 5.1 3.9 12.95 3 4.8 17.45 11.55 4 10 27 E3X-DA-N Amplifiers with M8 Connectors, Water-resistant Models E3X-DA14V E3X-DA44V *The Mounting Bracket can With Mounting Bracket Attached 4.9 x 3 = 14.7 30.05 25.95 Incident level indicator Threshold level indicator also be used on side A. Operation indicator a *1 81.5 Two, 2.4 dia. 6.9 12 40 2.8 M8 33 8 9.9 11.2 10.7 3.9 3.4 37 67.2 11.5 Mounting Holes Hole for optical communications 16 23.9 14.4 4.3 11 E39-L148 Mounting Bracket (order separately) SUS304 stainless steel 16 23.9 Two, M3 3.4 5.4 16 5.4 3.4 Incident level indicator Amplifiers with Standard Connectors, Twin-output Models Threshold level indicator E3X-DA6TW Operation indicator E3X-DA8TW 13.05 17.15 10 4.9 x 3 = 14.7 3 Two, 2.4 dia. 64.3 31.5 8 14 9.9 10.7 5.5 3.4 1.8 38.6 13 36.7 Hole for optical communications 5.1 3.9 1.8 1.7 4.2 6.2 Dimensions with Master Connector Connected 1.7 Dimensions with Slave Connector Connected 71 67.5 71 67.5 64.3 64.3 E3X-CN22: 4.0 dia. E3X-CN21: 4.0 dia. 31.5 1.5 1.8 5.1 3.9 31.5 1.5 12.95 4 10 1.8 5.1 3.9 12.95 3 4.8 17.45 11.55 4 10 28 E3X-DA-N Amplifiers with Connectors Master Connectors E3X-CN11 E3X-CN21 +50 0 2,000 10 6 2.9 10.7 6.8 2.6 4 4 dia. * 14.4 6 8.4 15.1 0.8 102 302 +50 0 50 * E3X-CN11: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). Slave Connectors E3X-CN12 E3X-CN22 +50 0 2,000 10 6 10.7 6.8 2.9 4 2.6 * E3X-CN12: 2.6 dia. E3X-CN22: 4 dia. 14.4 6 102 302 8.4 15.1 0.8 3 +50 0 50 * E3X-CN12: 2.6-dia. vinyl-insulated round cable with 1 conductor (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2; Insulation diameter: 1.1 mm). Mobile Console E3X-MC11 Mobile Console AC adapter jack Mobile Console Head Communications jack Communications jack 26 10 20 22 Menu indicators 52.8 (38.2) 31.8 13.2 Connection indicator 13.1 16.3 28.8 1.2 5.1 12.3 17.3 24.3 30.3 27.7 9.9 Channel indicator M5 ball plunger Output indicator Mode display 31.2 36.7 51.3 5.6 Optical communications position Channel buttons 136 Escape button Teaching button Enter button Mode button 57 57 Power supply button Function button Battery indicators 12 26 50 Accessories (Order Separately) Mounting Brackets End Plate In the interest of product improvement, specifications are subject to change without notice. 29 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.