R
1
Self -P owered Count Totalizer H7EC
Subminiature Total Counters With
Improved Appearance and Features
HLarge display with 8.6 mm (0.338 in) height
HAvailable with backlit LCD
HPNP/NPN DC voltage input available
HEight-digits, counting range 0 to 99999999
HKey-protect switch to prevent front resetting
HSelectable input speed: 30 Hz or 1 kHz
(except for AC/DC multi-voltage input
models)
HNEMA 4/IP66 front
HReplaceable battery
HNew black case
Ordering Information
TOTAL COUNTERS
C
o
u
n
t
i
n
p
u
t
M
a
x
c
o
u
n
t
i
n
g
s
p
e
e
d
D
i
s
p
l
a
y
P
a
r
t
n
u
m
b
e
r
Count input Max. counting speed Display Part number
PNP/NPN universal DC
voltage input
30 Hz or 1 kHz (Selectable) 7-segment LCD with
backlight
H7EC-NV-BH
g
p
7-segment LCD H7EC-NV-B
AC/DC multi-voltage input 20 Hz 7-segment LCD H7EC-NFV-B
No-voltage 30 Hz or 1 kHz (Selectable) 7-segment LCD H7EC-N-B
MODEL NUMBER LEGEND
1. Count Input
None: No-voltage input
V: PNP/NPN universal DC voltage input
FV: AC/DC multi-voltage input
3. Case Color
B: Black
2. Display
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
JACCESSORIES (ORDER SEPARATELY)
Item Part number
Replacement Battery Y92S-36
Wire-wrap Terminal (set of two Terminals)Y92S-37
Flush Mounting Adapter 26 mm ×45 mm Y92F-75
g
p
24.8 mm ×48.8 mm Y92F-77B
H7EC H7EC
2
Specifications
GENERAL
Item H7EC-NV-B
H7EC-NV-BH
H7EC-NFV-B H7EC-N-B
Operating mode Up type
Mounting method Flush mounting
External connections Screw terminals, optional Wire-wrap Terminals (See Note 1.)
Reset External/Manual reset
Number of digits 8
Count input PNP/NPN universal DC voltage
input
AC/DC multi-voltage input No-voltage input
Display 7-segment LCD with or without backlight (character height: 8.6 mm) (See Note 2.)
Max. counting speed 30 Hz/1 kHz 20 Hz 30 Hz/1 kHz
Case color black
Attachment Waterproof packing, flush mounting bracket
Approved standard UL508, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Note: 1. Wire-wrap Terminals (Y92S-37) can be ordered separately.
2. Only PNP/NPN universal DC voltage input models (-H models) are available with a backlight.
JRATINGS
Item H7EC-NV-B
H7EC-NV-BH
H7EC-NFV-B H7EC-N-B
Supply voltage Backlight model: 24 VDC (only
for backlight)
No-backlight model: Not
required (powered by battery)
Not required (powered by battery)
Count input High (logic) level: 4.5 to
30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx.
4
7
k
)
High (logic) level: 24 to
240 VAC/VDC, 50/60 Hz
Low (logic) level: 0 to 2.4 VAC/
VDC, 50/60 Hz
No voltage input
Maximum short-circuit
impedance: 10 kmax.
Short-circuit residual voltage:
0
5
V
Reset input
(
p
p
p
p
4.7 k)No voltage input
Maximum short-circuit
impedance: 10 kmax.
Short-circuit residual voltage:
0.5 V max.
Minimum open impedance:
750 kmin.
g
0.5 V max.
Minimum open impedance:
750 kmin.
Max. counting speed
(see Note.)
30 Hz or 1 kHz (Selectable) 20 Hz 30 Hz or 1 kHz (Selectable)
Minimum signal width 20 Hz: 25 ms
30 Hz: 16.7 ms
1kHz:0.5ms
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw tightening
torque
0.98 N Smmax.
Ambient Temperature Operating: --10°Cto55°C(14°F to 131°F) with no condensation or icing
Storage: --25°Cto65°C(--13°F to 149°F) with no condensation or icing
Ambient humidity Operating: 25% to 85%
Note:ON/OFF ratio 1:1
H7EC H7EC
3
JCHARACTERISTICS
Item H7EC-NV-B
H7EC-NV-BH
H7EC-NFV-B H7EC-N-B
Insulation resistance 100 Mmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts, and
between the backlight power
supply terminal and count input
terminals/reset terminals for
backlight models
100 Mmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts and
between count input terminals
and reset terminals
100 Mmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts and
between the backlight power
supply terminal and count input
terminals/reset terminals for
backlight models
3,700 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts
2,200 VAC, 50/60 Hz for 1 min
between reset terminals and
exposed non-current-carrying
metal parts and between count
input terminals and reset
terminals
1,000 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts
Impulse withstand voltage 4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
3 kV between input terminals
and reset terminals
4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
Noise immunity Between input terminals: ±600
V in normal mode, ±1.5 kV in
command mode
For backlight power supply
(backlight model): ±480 V in
normal mode, ±1.5 kV in
command mode
Between count input terminals:
±1.5 kV in normal mode, ±1.5
kV in command mode
Between reset input terminals:
±500 V in normal mode, ±1.5
kV in command mode
±500 V in normal mode, ±1.5
kV in command mode
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.35-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s23 times each in 6 directions
Destruction: 300 m/s23 times each in 6 directions
Battery life 7 years min. with continuous input at 25°C (lithium battery)
EMC (EMI) EN50081-1
Emission Enclosure: EN55022 class B
(EMS) EN50082-2
Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
ENV50204: 10 V/m (900 MHz ±5MHz)(level3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3)
Immunity Burst: EN61000-4-4: 2-kV power line (level 3)
2-kV I/O signal line (level 4)
Enclosure rating Front panel: IP66, NEMA4
Terminal block: IP20
Weight (See Note.) Non-backlight model: Approx.
60 g
Backlight model: Approx. 65 g
Approx. 60 g Approx. 60 g
Note:Weight includes waterproof packing and panel mounting bracket.
H7EC H7EC
4
Nomenclature
Front view
Bottom view
Reset Key
Reset the count value. Not operable
under key-protect.
Key-protect Switch
Counting speed switch
For all models except for H7EC-NFV-j
If the switch setting is changed, press the
Reset Key on the front panel.
Key-protect
Front panel
ON
Terminal block
Setting
(see note) Counting speed
Front panel
30 Hz
(default setting)
1kHz
Terminal block
Setting
(see note)
OFF
(default setting)
JTOTAL COUNTER
Note: Perform switch setting before mounting to a control panel.
Operation
JOPERATING MODES
H7EC Total Counter
Incrementing Operation
(Up)
Reset
Counting display values
Full-scale
(Full-scale
-- 1 )
Count input
H7EC H7EC
5
Dimensions
Unit: mm (inch)
JH7EC-N
Panel Cutout
Dimensions with Flush Mounting Bracket
When mounting, insert the Counter into
the cutout. Insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
The appropriate thickness of the panel
is1to5mm.
Separate mounting
Joint mounting
Waterproofing is not possible
for joint mounting
60 min.
22.2 +0.5
0
45+0.5
0
60 min.
22.2 +0.5
0
(48 ¢Units - 2.5) +10
0
44.8
(1.76)
48
(1.89)
24
(0.94)
48.5
(1.91)
22
(0.87)
35
(1.38)
37
(1.46)
Installation
JTERMINAL ARRANGEMENT
Bottom view: View of the Total Counter rotated horizontally 180°
Backlight Model Non-backlight Model
Reset
input
Count
input
Backlight
24 VDC
Reset
input
Count
input
H7EC H7EC
6
Connections
JPNP/NPN UNIVERSAL DC VOLTAGE
INPUT MODEL WITH BACKLIGHT
1. Contact Input (Input by a Relay or Switch Contact) 2. Solid-state Input
Relay
Input Reset
Relay
or Switch or Switch
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Open collector of a
PNP transistor
Open collector of a
PNP transistor
Input Reset
Backlight
24 VDC Backlight
24 VDC
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
H7EC H7EC
7
JNO-VOLTAGE INPUT MODEL
1. Contact Input (Input by a Relay or Switch Contact)
2. Solid-state Input
(Open Collector Input of an NPN Transistor)
Note: Use Relays and Switches that have high contact reli-
ability because the current flowing from terminals 1 or
3 is as small as approx. 10 µA. OMRON’s G3TA-IA/ID
is recommended as the SSR.
Note:1. Residual voltage in the output section of Proximity
Sensors or Photoelectric Sensors becomes less than
0.5 V because the current flowing from terminals 1 or 3
is as small as approx. 10 µA, allowing easy
connection.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
JAC/DC MULTI-VOLTAGE INPUT MODEL
JPNP/NPN UNIVERSAL DC VOLTAGE
INPUT MODEL WITHOUT BACKLIGHT
1. Contact Input (Input by a Relay or Switch Contact)
2. Solid-state Input
or Open collector of an
NPN transistor
or Open collector of an
NPN transistor
Note:1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector 50 V
Leakage current < 1 µA
Relay
Input Reset
Relay
or Switch or Switch
Terminals 2 and 4 are
internally connected.
or Switch
Open collector of an
NPN transistor
Open collector of an
NPN transistor
Input Reset
Terminals 2 and 4 are
internally connected.
Relay
Relay
Input Reset
or Switch or Switch
or Open collector of
an NPN transistor
Relay
Input Reset
Relay
or Switch or Switch
Open collector of a
PNP transistor
Open collector of a
PNP transistor
Input Reset
H7EC H7EC
8
Accessories
(
O
rder
S
eparately
)
An H7EC is supplied with a mounting bracket and nut. In addition, the Flush Mounting Adapters shown here allow the H7EC to be fitted to
existing panel cutouts.
JY92F-77B FLUSH MOUNTING ADAPTER
FOR 24.8 ¢48.8 RECTANGULAR CUTOUT
Must be used with mounting bracket supplied with the Counter Panel cutout
JY92F-75 FLUSH MOUNTING ADAPTER
FOR 26 ¢45 RECTANGULAR CUTOUT
Must be used with mounting bracket supplied with the Counter
Panel Cutout
28.8
(1.13) 24.2 22.2
45.2
48.2
53.8
(2.12)
4
24.8
(0.98)
48.8
(1.92)
31
(1.22) 24.2 22.2
45.2
48.2
Two 3.5 dia. mounting holes
26
(1.02)
4
63
72
(2.83)
Two M3
45
63
(2.48)
26
JY92S-37 WIRE-WRAP TERMINAL
(SET OF TWO TERMINALS)
44.8
(1.76)
24
(0.94)
48
(1.89) 2548.5 17.1
22
Wire-wrap terminal
(1 ×1 mm)
65.6
(2.58)
The wire--wrap terminals have a cross sectional dimension of
1x1 mm. Select one of three guages of wire from the table at
right. Also listed in the table is the appropriate wiring hardware
Wire Bit Sleeve Wrapped
state
AWG22 2-A 2-B Normal
AWG24 1-A 1-B Normal
AWG26 1-B 1-B Normal
H7EC H7EC
9
JY92S-36 REPLACEMENT (LITHIUM)
BATTERY (3 V)
24.5 dia.
7.7
Precautions
WARNING
This product has a built-in lithium battery. Do not short-circuit
the + and -- terminals, charge, disassemble, deform, or expose
the battery to fire. The battery may explode (break), catch fire,
or cause liquid leakage.
Caution
Do not use any battery other than the specified one (Y92S-36).
Using another battery may cause liquid leakage or breakage,
resulting in malfunction or injury.
Caution
If a voltage other than the rated one is applied, internal
elements may be damaged.
Do not use the Counter in the following places:
Locations subject to direct sunlight.
Locations subject to corrosive gases.
Locations subject to dust.
JBEFORE USE
An insulation sheet has been inserted to maintain the quality of
the Totalizer in the event of a long period without use. Be sure to
remove this sheet before attempting to use the product.
Remove the insulation sheet and press the Reset Key on the
front panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H),
models, “0” or “0.0” will be displayed after 1 s.)
Reset Key
Insulation Sheet
Switch settings on the Counter must be performed before
mounting it to a control panel.
Do not use the Counter in locations subject to:
SSevere changes in temperature.
SCondensation as the result of high temperatures.
JMOUNTING PRECAUTIONS FOR FLUSH
MOUNTING
Although the operating section is watertight (conforming to
NEMA4, IP66), rubber packing is provided to avoid water leakage
through the gap between the Counter and panel cutout. Unless
this rubber packing is tightly squeezed on, water may permeate
inside the panel. For this reason, be sure to tighten the screws
for fixing the Flush Mounting Bracket.
Screw for the Flush Mounting Bracket
The wider side must
face the panel.
Adapter
Panel
0.5to1mm
Adapter screw section
Tighten the screw until the
distance is within the range
shown above.
!
!
!
H7EC H7EC
10
JRESET INPUT AND COUNT INPUT
The H7EC operates using its built-in Battery. If the H7EC is
connected to a device that has +V and OUT terminals that are
connected with a diode as shown in the circuit diagram, the
circuit indicated by the arrow 1 or 2 will be formed when the
device is turned OFF. As a result, the H7EC may be reset or
count by one. It is recommended that such devices not be
connected to the H7EC.
Count input
or reset input
circuit
Internal
If an excessive voltage is applied to the count or reset input
terminals, the internal elements may be damaged.
Ensure that the following voltages are not exceeded:
SPNP/NPN universal voltage input model: 30 VDC
SAC/DC voltage input model:
At count input: 240 VAC (peak voltage: 338V)
240 VDC
At reset input: 3 VDC (no-voltage input)
No-voltage input model: 3 VDC
Do not remove the outer case when voltage is being applied to
the power supply terminals or to the input terminals.
The input for the H7Ej-NFV-jis a high-impedance circuit so
influence from an induced voltage may result in malfunction.
When the input signal wiring is longer than 10 m (stray
capacitance of 120 pF/m, at room temperature), a CR filter or a
bleeder resistor should be connected.
JCOUNT INPUT OR RESET INPUT TO
MORE THAN ONE H7E COUNTER AT
ATIME
PNP/NPN Universal DC Voltage Input
or
or
Note:H (Reset ON) level must be 4.5 V minimum.
H= 4.7 (k)/N + V
4.7 (k)/N + R
No-voltage Input
or
Note: 1. The leakage current of the transistor used for input
must be less than 1 µA.
2. The forward voltage of the diode must be as low as
possible (i.e., 0.1 V maximum with an IFof 20 µA) so
the voltage between terminals 3 and 4 will be 0.5 V
when the reset input is ON.
H7EC H7EC
11
JINPUT AND POWER SUPPLY
Do not apply voltage on the Counter if the Counter is a model
that operates with no-voltage input, to avoid damaging the
internal circuit of the Counter.
Do not connect any single input signal in parallel to Counter
models operating with no-voltage input and those operating with
voltage input, otherwise the Counters may malfunction.
When connecting a sensor to the Counter that operates with
no-voltage input, make sure that the sensor has open collector
output.
Sensor
The operation of the Counter may be affected if the line voltage
of the power supply exceeds 500 pF (about 10 m, with parallel
wires of 2 x 2 mm). Keep all wires as short as possible. When
using shielded wire, stray capacitance may occur.
When connecting an open collector input from a transistor to the
Counter that operates with no-voltage input, make sure that the
leakage current of the transistor is 5 µA maximum.
When connecting count input from an SSR to the Counter that
operates with AC/DC voltage input, use OMRON’s G3TA-IA or
G3TA-ID SSR. Otherwise, make sure that the leakage current of
the SSR is 0.1 mA maximum or connect a bleeder resistor in
parallel to the input circuit of the Counter.
Leakage current:
0.1 mA max.
or
or
or
*Bleeder resistor
The voltage between terminals 1 and 2 must be
1.5 V maximum when the SSR is OFF.
JBACKLIGHT POWER SUPPLY
To reduce variation in the brightness of the backlight when using
more than one H7E with a backlight, use the same power supply
for all the backlights.
When connecting the DC power supply for the backlights, be
sure to connect the polarities correctly.
JBATTERY REPLACEMENT
Remove the wiring when replacing the Battery. Do not come in
contact with any item to which high voltage is being applied.
Doing so may result in electric shock.
Before changing the Battery, be sure that you are not carrying
any static electric charge.
Procedure for replacing the Battery (refer to the diagrams below):
1. Using the tool, pry open the lift-tab on the case. (1)
2. Pull the body out of its outer case. (2)
3. Lift the Battery up by the edge and remove it. (3)
When removing the Battery, do not come in contact with the
display area or any internal parts.
4. Wipe the back of the new Battery before inserting it.
5. Ensure that the + and -- terminals are correctly oriented.
6. After replacing the Battery, re-insert the body into its case. (4)
Check that the case is securely held in by the lift-tab.
7. Press the Reset Key before use (not necessary for
H7ER-N,-NV,-NV1). (5)
When the internal Battery nears expiration, the display may
flicker.
Tool
(2)
(1)
(1)
(3)
(4)
(5)
JEN/IEC STANDARDS
The counter input, reset input, and backlight power supply
terminals of the no-voltage input or PNP/NPN universal DC
voltage input models (H7Ej-N,-N1, H7Ej-NV(-H),-NV1(-H)) are
not isolated.
A SELV power supply conforming to Appendix H of IEC61010-1
should be used for the counter input, reset input and backlight
power supply terminals. A SELV power supply is a power supply
for which the input and output have double or reinforced
insulation, and for which the output voltage is 30 Vrems with 42.4
V peak or 60 VDC max. (Only the H7Ej-NVj-H has a
backlight.)
The terminals for counter input and reset input for AC/DC
multi-voltage input models have basic insulation.
Connect the reset input terminals to a device that does not have
exposed current-carrying parts and has basic insulation for
240 VAC.
H7EC H7EC
12
Cat. No. GC TMCN1 3/02 Specifications subject to c hange without notice. Printed i n U.S.A.
OMRON ELECTRONICS LLC
OneEastCommerceDrive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci