H7EC H7EC
3
JCHARACTERISTICS
Item H7EC-NV-B
H7EC-NV-BH
H7EC-NFV-B H7EC-N-B
Insulation resistance 100 MΩmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts, and
between the backlight power
supply terminal and count input
terminals/reset terminals for
backlight models
100 MΩmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts and
between count input terminals
and reset terminals
100 MΩmin. (at 500 VDC)
between current-carrying metal
parts and exposed non-current
carrying metal parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts and
between the backlight power
supply terminal and count input
terminals/reset terminals for
backlight models
3,700 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts
2,200 VAC, 50/60 Hz for 1 min
between reset terminals and
exposed non-current-carrying
metal parts and between count
input terminals and reset
terminals
1,000 VAC, 50/60 Hz for 1 min
between current-carrying metal
parts and exposed non-current
carrying metal parts
Impulse withstand voltage 4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
3 kV between input terminals
and reset terminals
4.5 kV between current-carrying
terminal and exposed
non-current-carrying metal
parts
Noise immunity Between input terminals: ±600
V in normal mode, ±1.5 kV in
command mode
For backlight power supply
(backlight model): ±480 V in
normal mode, ±1.5 kV in
command mode
Between count input terminals:
±1.5 kV in normal mode, ±1.5
kV in command mode
Between reset input terminals:
±500 V in normal mode, ±1.5
kV in command mode
±500 V in normal mode, ±1.5
kV in command mode
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.35-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s23 times each in 6 directions
Destruction: 300 m/s23 times each in 6 directions
Battery life 7 years min. with continuous input at 25°C (lithium battery)
EMC (EMI) EN50081-1
Emission Enclosure: EN55022 class B
(EMS) EN50082-2
Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
ENV50204: 10 V/m (900 MHz ±5MHz)(level3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3)
Immunity Burst: EN61000-4-4: 2-kV power line (level 3)
2-kV I/O signal line (level 4)
Enclosure rating Front panel: IP66, NEMA4
Terminal block: IP20
Weight (See Note.) Non-backlight model: Approx.
60 g
Backlight model: Approx. 65 g
Approx. 60 g Approx. 60 g