Uninterruptible Power Supplies S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS The new SolaHD S4K4U6000C and the S4K6U10KC Industrial UPS Series are the first true On-Line industrial UPS that provide higher output power factor, higher efficiency, flexible output voltage, an integrated maintenance bypass switch and internal batteries all in slim 4U (7.0") and 6U (10.5") enclosures respectively. The S4K4UC and S4K6UC features true On-Line (double conversion) topology providing the ultimate in protection against a wide range of potential power problems. The S4K4UC design of two 3 kVA, 120V inverters allow flexible output voltage to meet mixed load voltage requirements. The UPS automatically configures the output voltage to match the input configuration without requiring tap selections. Self diagnostics simplify maintenance and troubleshooting. The standard maintenance bypass switch provides an additional level of protection. The S4K4UC and S4K6UC also feature a wide input voltage window to support the critical load without having to transfer to the battery. This extends system availability when back-up is truly needed. Industrial Automation Systems Network Servers Enterprise Telecommunication Systems Printing and Publishing Machinery Pharmaceutical and Medical Diagnosis Equipment Industrial and Commercial Machinery Micro-processor Controlled Equipment Mission Critical Devices Certifications and Compliances * Features * True double conversion topology * Higher power factor of 0.80 (6kVA) and 0.90 (10kVA) * Both models offer 208/120V or 240/120V * Configurable as a tower or rack mounting * Highest density, 6 kVA in only 4U and 10 kVA in only 6U of rack space * Easily installed in 18" to 32" deep rack using rack mount kit # SRS1832 * User replaceable, hot-swappable internal battery module * Extended battery cabinets * Includes both automatic and manual maintenance bypass switch 86 * Automatic frequency detection (60 or 50 Hz) * Power factor correction * Self-diagnostics simplify maintenance and troubleshooting * Remote emergency Power Off (REPO) * IntellislotTM USB and terminal block communication ports * Compatible with most standby generators * Uses an average of 35% less energy than their standard counterparts * Provides continuous uptime for the connected equipment, with capacity and battery back-up delivered in cabinets that use 4U to 6U of rack space * Two year limited warranty Applications * Industrial Computers * Robotics and Process Controls * * * * * * * * ENPC E179213 Listed, UPS Equipment - UL 1778 - CSA C22.2 No. 107.3 * IEEE/ANSI C62.41 Category A & B * ISTA Procedure 1A * ABS Type Approved * RoHS Compliant * ENERGY STAR(R) certified Related Products * Portable MCR Power Conditioners * Surge Protective Devices * Active Tracking(R) Filters Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies S4K 6 and 10 kVA Specifications Table 1: UPS Specifications Parameters Rating Model Number S4K4U6000C S4K6U10KC 4800 W/6000 VA 9000 W/10000 VA Dimensions, W x D x h, in. (mm) Unit 6.80 x 26.10 x 16.90 (173.0 x 662.0 x 430.0) 10.30 x 26.50 x 16.90 (261.0 x 672.0 x 430.0) Shipping 13.20 x 33.10 x 26.10 (336.0 x 842.0 x 662.0) 16.70 x 32.80 x 24.10 (424.0 x 832.0 x 612.0) weight, lbs. (kg) Unit 56.2 (25.50) 78.3 (35.50) Shipping 70.5 (32.00) 92.6 (42.00) Input AC Parameters Nominal Operating Frequency 50 or 60 Hz (Factory default is 60 Hz) 120/208 Vac @ 120C Factory Default Vac 120C L1-L2 Factory Default Input Phase Angle Allowable Input Phase Angle 120, 180, 240 degrees; auto-sensing on application of alternating current (Restrictions for L-N voltage other than 120 Vac) 120 Vac nominal Factory Default L1-N, L2-N Vac User Configurable L1-N, L2-N Vac 100/110/115/120/127 Vac (Can be modified with configuration program) 40-70 Hz Input Frequency w/o Battery Operation Input Power Connection Hardwire terminal block 3W + G (L-L-N-G) 150 Vac L1-N, L2-N Maximum Allowable Vac Output AC Parameters 120/208 Vac @ 120C Factory Default Vac 120C L1-L2 Factory Default Output Phase Angle Allowable Output Phase Angle 120, 180, 240 degrees; auto-sensing on initial application of input alternating current Factory Default L1-N, L2-N Vac 120 Vac nominal User Configurable L1-N, L2-N Vac 100/110/115/120/127 Vac, 2% L1-N, L2-N Overload Rating 105% to 130% 1 minute 131% to 150% 10 seconds 151% to 200% 1 second >200% (impact load) Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 At least 5 cycles 87 Uninterruptible Power Supplies S4K 6 and 10 kVA Specifications - continued Table 2: UPS Specifications Parameters Model Number S4K4U6000C S4K6U10KC Bypass Protection Limits Disable Bypass Operation Re-enable Bypass Operation Disable Bypass Operation If input voltage exceeds 15% of the nominal voltage If input voltage returns to within 10% of nominal output voltage When the input frequency prevents synchronous operation Environmental Requirements Operating Temperature 0C to +40C; see Table 11 for operating temperature parameters -15C to +50C Storage Temperature 0% to 95%, non-condensing Relative Humidity Up to 10,000 ft. [3,000 m] Operating Elevation <55 dBA @ 3.2 ft. [1 m] rear; <50 dBA @ 3.2 ft. [1 m] front & sides Audible Noise Standards FCC Part 15, Subpart B, Class A, FCC Class A EMC Table 3: Operating Temperature Parameters Ambient Temperature 88 Model Number S4K4U6000C S4K6U10KC pf @ 30C 3C 0.8 pf 0.9 pf pf @ 40C 3C 0.8 pf 0.8 pf Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies Table 4: Internal Battery Specifications Parameters Used with UPS Models Model Number S4K144INTBATC S4K288INTBATC S4K4U6000C S4K6U10KC Dimensions, W x D x h, in. (mm) Unit Shipping 2.80 x 19.30 x 8.10 (70.0 x 490.0 x 206.0) 5.30 x 19.70 x 8.10 (135.0 x 500.0 x 207.0) 12.20 x 23.70 x 10.30 (310.0 x 602.0 x 262.0) 12.20 x 23.90 x 9.50 (310.0 x 607.0 x 242.0) Weight, lbs. (kg) Unit 75.8 (34.40) 71.1 (32.30) Shipping 81.1 (36.80) 76.4 (34.70) Battery Parameters Type Qty x V x Rating Valve-regulated, non-spillable, flame retardant, lead acid 2 x 6 x 12 V x 9.0 Ah 2 x 12 x 12 V x 9.0 Ah CSB type UPS12460F2 Battery Mfr./Part Number Back-up Time See Table 8 Recharge Time 3 hours to 90% capacity after full discharge into 100% load Environmental Requirements 0C to +40C Operating Temperature -15C to +50C Storage Temperature 0% to 95%, non-condensing Relative Humidity Operating Elevation Up to 10,000 ft. [3,000 m] at +40C without derating Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 89 Uninterruptible Power Supplies Table 5: External Battery Cabinet Specifications Parameters Used with UPS Models Model Number S4K144BATC S4K288BATC S4K4U6000C S4K6U10KC Dimensions, W x D x h, in. (mm) Unit (with bezel) Shipping 3.30 x 26.10 x 16.90 (85.0 x 662.0 x 430.0) 6.80 x 26.50 x 16.90 (173.0 x 672.0 x 430.0) 25.80 x 34.30 x 12.30 (655.0 x 872.0 x 312.0) 13.20 x 33.10 x 24.50 (336.0 x 842.0 x 622.0) Weight, lbs. (kg) Unit 99.9 (45.30) 29.8 (13.50) Shipping 110.2 (50.00) 44.1 (20.00) Battery Parameters Type Qty x V x Rating Valve-regulated, non-spillable, flame retardant, lead acid 2 x 6 x 12 V x 9.0 Ah 2 x 12 x 12 V x 9.0 Ah CSB type UPS12460F2 Battery Mfr./Part Number See Table 8 Back-up Time Environmental Requirements Operating Temperature Storage Temperature Relative Humidity Operating Elevation 90 0C to +40C -15C to +50C 0% to 95%, non-condensing Up to 10,000 ft. [3,000 m] at +40C without derating Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies Table 6: Power Distribution Specifications for S4K4U6000C Model Number Parameters S4KPAD2HDWRC S4KPAD2HDWR-MBSC * S4KPAD2001C S4KPAD2002C S4KPAD2003C S4KPAD2004C S4KPAD2005C S4KPAD2006C Dimensions, W x D x h, in. (mm) Unit 5.20 x 15.50 x 3.50 (132.0 x 393.0 x 88.0) Shipping 9.50 x 20.70 x 9.10 (242.0 x 527.0 x 230.0) Weight, lbs. (kg) Unit 5.1 (2.30) 6.0 (2.70) 8.8 (4.00) 8.6 (3.90) 8.6 (3.90) 9.9 (4.50) 10.6 (4.80) 9.5 (4.30) Shipping 7.3 (3.30) 8.2 (3.70) 11.0 (5.00) 10.8 (4.90) 10.8 (4.90) 12.1 (5.50) 12.8 (5.80) 11.7 (5.30) (4) L5-20R (2) L6-30R (4) L6-20R Electrical Specifications 30 A 2-pole input breaker Amp Rating Input Power Connections Hardwire terminal block 3W + G (L-L-N-G) Output Power Connections Hardwire terminal block 3W + G (L-L-N-G) (1) L14-30R on a 300 mm cord (4) 5-20R (1) L14-30R (1) L6-30R (2) 5-20R (2) L6-20R (4) 5-20R (2) L6-30R (4) L5-20R (2) L5-30R * Standard on S4K4U6000C units Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 91 Uninterruptible Power Supplies Table 7: Power Distribution Specifications for S4K6U10KC Parameters Model Number S4KPAD2-101C S4KPAD2-102C S4KPAD2-103C S4KPAD2-104C S4KPAD2-105C S4KPAD2-106C Dimensions, W x D x h, in. (mm) 7.40 x 5.70 (188.0 x 145.0) Unit 11.90 x 20.60 x 8.70 (302.0 x 522.0 x 220.0) Shipping Weight, lbs. (kg) Unit 4.4 (2.00) 6.6 (3.00) 4.4 (2.00) 6.6 (3.00) Shipping 6.6 (3.00) 8.8 (4.00) 6.6 (3.00) 8.8 (4.00) (4) 5-20R (2) L5-30R (2) L5-20R (4) L6-20R (4) L5-20R Electrical Specifications Amp Rating 60 A 2-pole input breaker Input Power Connections Hardwire terminal block 3W + G (L-L-N-G) to chassis Output Power Connections 92 (2) L6-30 (8) 5-20R (4) L6-20R (4) 5-20R (4) 5-20R (4) L6-30R (4) 5-20R (2) L6-30R (2) L6-20R Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sola/Hevi-Duty: A2D130HW S4K288BATC SRS1832 S4K288INTBATC S4K144BATC