APTM20AM10FT VDSS = 200V RDSon = 10m typ @ Tj = 25C ID = 175A @ Tc = 25C Phase leg MOSFET Power Module NT C2 Q1 G1 OUT S1 Q2 G2 S2 0/VBU S G2 S2 VBUS 0/VBUS NT C1 OUT OUT S1 S2 NTC2 G1 G2 NTC1 Application * Welding converters * Switched Mode Power Supplies * Uninterruptible Power Supplies Features * Power MOS 7(R) FREDFETs - Low RDSon - Low input and Miller capacitance - Low gate charge - Fast intrinsic reverse diode - Avalanche energy rated - Very rugged * Kelvin source for easy drive * Very low stray inductance - Symmetrical design - Lead frames for power connections * Internal thermistor for temperature monitoring * High level of integration Benefits * Outstanding performance at high frequency operation * Direct mounting to heatsink (isolated package) * Low junction to case thermal resistance * Solderable terminals both for power and signal for easy PCB mounting * Low profile Absolute maximum ratings Symbol VDSS ID IDM VGS RDSon PD IAR EAR EAS Parameter Drain - Source Breakdown Voltage Tc = 25C Tc = 80C Continuous Drain Current Pulsed Drain current Gate - Source Voltage Drain - Source ON Resistance Maximum Power Dissipation Avalanche current (repetitive and non repetitive) Repetitive Avalanche Energy Single Pulse Avalanche Energy Tc = 25C Max ratings 200 175 131 700 30 12 694 89 50 2500 Unit V A V m W A mJ These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed. APT website - http://www.advancedpower.com 1-6 APTM20AM10FT - Rev 2 July, 2005 VBUS APTM20AM10FT All ratings @ Tj = 25C unless otherwise specified Electrical Characteristics IDSS RDS(on) VGS(th) IGSS Characteristic Zero Gate Voltage Drain Current Drain - Source on Resistance Gate Threshold Voltage Gate - Source Leakage Current Dynamic Characteristics Symbol Ciss Coss Crss Qg Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Total gate Charge Qgs Gate - Source Charge Qgd Gate - Drain Charge Td(on) Turn-on Delay Time Tr Td(off) Test Conditions Rise Time Turn-off Delay Time Tf Fall Time Eon Turn-on Switching Energy Eoff Turn-off Switching Energy Eon Turn-on Switching Energy Eoff Turn-off Switching Energy VGS = 0V,VDS = 200V VGS = 0V,VDS = 160V Min VGS = 10V, ID = 87.5A VGS = VDS, ID = 5mA VGS = 30 V, VDS = 0V Test Conditions VGS = 0V VDS = 25V f = 1MHz VSD dv/dt Characteristic Continuous Source current (Body diode) Diode Forward Voltage Peak Diode Recovery X trr Reverse Recovery Time Qrr Reverse Recovery Charge 10 3 Min VGS = 10V VBus = 100V ID = 150A Typ 13.7 4.36 0.19 224 Unit Max Unit A m V nA nF nC 94 28 Inductive switching @ 125C VGS = 15V VBus = 133V ID = 150A R G = 2.5 56 99 926 1216 J 1062 Min Typ Tc = 25C Tc = 80C VGS = 0V, IS = - 150A Tj = 25C Tj = 125C Tj = 25C Tj = 125C J 910 Inductive switching @ 125C VGS = 15V, VBus = 133V ID = 150A, R G = 2.5 Test Conditions ns 81 Inductive switching @ 25C VGS = 15V, VBus = 133V ID = 150A, R G = 2.5 IS = - 150A VR = 133V diS/dt = 200A/s Max 375 1500 12 5 150 86 Source - Drain diode ratings and characteristics Symbol IS Typ Tj = 25C Tj = 125C 2.14 5.8 Max 175 131 1.3 8 220 420 Unit A V V/ns ns C X dv/dt numbers reflect the limitations of the circuit rather than the device itself. IS - 150A di/dt 700A/s VR VDSS Tj 150C APT website - http://www.advancedpower.com 2-6 APTM20AM10FT - Rev 2 July, 2005 Symbol APTM20AM10FT Thermal and package characteristics Symbol RthJC VISOL TJ TSTG TC Torque Wt Characteristic Junction to Case Min RMS Isolation Voltage, any terminal to case t =1 min, I isol<1mA, 50/60Hz 2500 -40 -40 -40 1.5 Operating junction temperature range Storage Temperature Range Operating Case Temperature Mounting torque Package Weight To Heatsink M5 Typ Max 0.18 150 125 100 4.7 160 Temperature sensor NTC (see application note APT0406 on www.advancedpower.com for more information). Symbol Characteristic R25 Resistance @ 25C B 25/85 T25 = 298.15 K RT = Min R 25 Typ 50 3952 Max Unit C/W V C N.m g Unit k K T: Thermistor temperature 1 1 RT : Thermistor value at T exp B 25 / 85 - T25 T APT website - http://www.advancedpower.com 3-6 APTM20AM10FT - Rev 2 July, 2005 SP4 Package outline (dimensions in mm) APTM20AM10FT Thermal Impedance (C/W) Typical Performance Curve Maximum Effective Transient Thermal Impedance, Junction to Case vs Pulse Duration 0.2 0.18 0.9 0.16 0.14 0.7 0.12 0.5 0.1 0.08 0.3 0.06 Single Pulse 0.04 0.1 0.02 0.05 0 0.00001 0.0001 0.001 0.01 0.1 1 10 rectangular Pulse Duration (Seconds) Low Voltage Output Characteristics VDS > ID(on)xR DS(on)MAX 250s pulse test @ < 0.5 duty cycle 9V 400 7.5V 300 7V 200 6.5V 6V 100 I D, Drain Current (A) 300 200 T J=25C 100 5.5V TJ =125C 0 0 0 5 10 15 20 25 2 VDS, Drain to Source Voltage (V) Normalized to V GS=10V @ 87.5A 1.15 1.1 VGS =10V 1.05 1 VGS =20V 0.95 0.9 0 40 80 120 160 200 I D, Drain Current (A) 3 4 5 6 7 8 9 VGS, Gate to Source Voltage (V) DC Drain Current vs Case Temperature RDS (on) vs Drain Current 1.2 240 I D, DC Drain Current (A) RDS(on) Drain to Source ON Resistance TJ =-55C 200 180 160 140 120 100 80 60 40 20 0 25 50 75 100 125 TC, Case Temperature (C) APT website - http://www.advancedpower.com 150 4-6 APTM20AM10FT - Rev 2 July, 2005 I D, Drain Current (A) V GS=15&10V Transfert Characteristics 400 500 1.1 1.0 0.9 0.8 0.7 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (C) Threshold Voltage vs Temperature I D, Drain Current (A) VGS(TH), Threshold Voltage (Normalized) 1.0 0.9 0.8 2.0 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (C) Maximum Safe Operating Area limited by RDSon 100s 100 1ms 10ms 10 0.7 DC line Single pulse TJ=150C 0.6 1 -50 -25 0 25 50 75 100 125 150 TC, Case Temperature (C) Ciss 10000 Coss 1000 Crss 100 0 10 20 30 40 50 VDS, Drain to Source Voltage (V) 1 VGS, Gate to Source Voltage (V) Capacitance vs Drain to Source Voltage 100000 C, Capacitance (pF) VGS=10V ID= 87.5A 1000 1.2 1.1 ON resistance vs Temperature 2.5 10 100 1000 VDS , Drain to Source Voltage (V) Gate Charge vs Gate to Source Voltage 12 V DS =40V ID=150A 10 TJ=25C V DS =100V 8 V DS =160V 6 4 2 0 0 APT website - http://www.advancedpower.com 50 100 150 200 250 Gate Charge (nC) 5-6 APTM20AM10FT - Rev 2 July, 2005 BVDSS, Drain to Source Breakdown Voltage (Normalized) Breakdown Voltage vs Temperature 1.2 RDS(on), Drain to Source ON resistance (Normalized) APTM20AM10FT APTM20AM10FT Rise and Fall times vs Current 90 160 80 140 td(off) 70 VDS=133V RG=2.5 TJ=125C L=100H 60 50 40 30 100 80 tr 60 20 10 0 0 50 100 150 200 250 300 0 50 I D, Drain Current (A) Eon Eoff 1 0.5 0 250 300 VDS=133V ID=150A TJ=125C L=100H 2.5 Eoff Eon 2 1.5 1 50 100 150 200 250 0 300 V DS=133V D=50% R G=2.5 T J=125C 250 200 150 100 50 0 20 40 60 80 100 120 140 160 ID, Drain Current (A) IDR, Reverse Drain Current (A) Operating Frequency vs Drain Current 300 10 15 20 Gate Resistance (Ohms) ID, Drain Current (A) 350 5 Source to Drain Diode Forward Voltage 1000 100 TJ =150C TJ =25C 10 1 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 VSD, Source to Drain Voltage (V) APT reserves the right to change, without notice, the specifications and information contained herein APT's products are covered by one or more of U.S patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. U.S and Foreign patents pending. All Rights Reserved. APT website - http://www.advancedpower.com 6-6 APTM20AM10FT - Rev 2 July, 2005 0 Frequency (kHz) 200 3 Switching Energy (mJ) Eon and Eoff (mJ) 1.5 150 Switching Energy vs Gate Resistance Switching Energy vs Current VDS=133V RG=2.5 TJ=125C L=100H 100 ID, Drain Current (A) 2.5 2 tf 40 td(on) 20 VDS=133V RG=2.5 T J=125C L=100H 120 t r and tf (ns) td(on) and td(off) (ns) Delay Times vs Current