Solid State Relays G3CN Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). PCB-mounting SSR for FA Equipment Requiring High Reliability * Wide I/O voltage range: 3 to 28 VDC input and 75 to 264 VAC output or 3 to 28 VDC input and 3 to 52.8 VDC output. * Two load currents available: 2 A and 3 A * Flat and vertical models available for a variety of applications. * Certified by UL and CSA. Model Number Structure Model Number Legend G3CN-@@@@@@@ 1 2 3 4 5 6 7 8 1. Basic Model Name G3CN: Solid State Relay 2. Load Power Supply D: DC output Blank: AC output 3. Rated Load Power Supply Voltage X: 50 VDC 2: 200 VAC 4. Rated Load Current 02: 2A 03: 3A 5. Terminal Type P: PCB terminals 6. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 7. Housing Blank: Flat type 1: Vertical type 8. Certification US: Certified by UL and CSA Solid State Relays G3CN 249 Ordering Information List of Models Isolation Photocoupler Zero cross function Yes Indicator No Rated output voltage 2 A at 100 to 240 VAC Rated input voltage 4 to 24 VDC Model G3CN-202P-US G3CN-202P1-US (See note 1.) 3 A at 100 to 240 VAC G3CN-203P-US G3CN-203P1-US (See note 1.) Phototriac No 2 A at 100 to 240 VAC 5, 12, 24 VDC (See note 2.) 3 A at 100 to 240 VAC G3CN-202PL-US G3CN-202PL1-US (See note 1.) G3CN-203PL-US G3CN-203PL1-US (See note 1.) Photocoupler --- 2 A at 4 to 48 VDC 4 to 24 VDC G3CN-DX02P-US G3CN-DX02P1-US (See note 1.) 3 A at 4 to 48 VDC G3CN-DX03P-US G3CN-DX03P1-US (See note 1.) Note: 1. Vertical models. 2. When ordering, specify the input voltage. 250 Solid State Relays G3CN Specifications Ratings (at an Ambient Temperature of 25C) Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage G3CN-202P(1)-US G3CN-203P(1)-US G3CN-202PL(1)-US G3CN-203PL(1)-US G3CN-DX02P(1)-US G3CN-DX03P(1)-US 4 to 24 VDC 3 to 28 VDC 1.5 k +20%/-10% 3 VDC max. 4 VDC max. 1 VDC min. 5 VDC 4 to 6 VDC 390 20% 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. 4 to 24 VDC 3 to 28 VDC 1.5 k +20%/-10% 3 VDC max. Note: The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the input impedance is measured at 28 VDC. Output Model Applicable load Rated load voltage Load voltage range Load current Inrush current Without heat sink G3CN-202P(1)-US G3CN-202PL(1)-US 100 to 240 VAC 75 to 264 VAC G3CN-203P(1)-US G3CN-203PL(1)-US G3CN-DX02P(1)-US 4 to 48 VDC 3 to 52.8 VDC G3CN-DX03P(1)-US 0.1 to 2 A 30 A (60 Hz, 1 cycle) 0.1 to 3 A 45 A (60 Hz, 1 cycle) 0.1 to 2 A 12 A (10 ms) 0.1 to 3 A 18 A (10 ms) Characteristics Item G3CN-202P(1)-US/203P(1)-US G3CN-202PL(1)-US/203PL(1)-US G3CN-DX02P(1)-US/03P(1)-US Operate time 1/2 of load power source cycle + 1 1 ms max. ms max. 0.5 ms max. Release time 1/2 of load power source cycle + 1 1/2 of load power source cycle + 1 2 ms max. ms max. ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 1.5 V max. 2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 5 mA max. (at 50 VDC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Certified standards UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535 Weight Approx. 25 g -30C to 80C (with no icing nor condensation) -30C to 100C (with no icing nor condensation) Solid State Relays G3CN 251 Engineering Data Load Current vs. Ambient Temperature Characteristics G3CN-203P(1)-US/-203PL(1)-US/-DX03P(1)-US Load current (A) Load current (A) G3CN-202P(1)-US/-202PL(1)-US/-DX02P(1)-US Ambient temperature (C) Ambient temperature (C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3CN-DX02P(1)-US Inrush current (A. Peak) Inrush current (A. Peak) G3CN-202P(1)-US/-202PL(1)-US Energized time (ms) Energized time (ms) 252 G3CN-DX03P(1)-US Inrush current (A. Peak) Inrush current (A. Peak) G3CN-203P(1)-US/-203PL(1)-US Energized time (ms) Solid State Relays G3CN Energized time (ms) Dimensions Note: All units are in millimeters unless otherwise indicated. Flat Model Terminal Arrangement/ Mounting Holes (Bottom View) G3CN-20@P-US/-20@PL-US/-DX0@P-US 33 max. Four 1.2-dia. holes Two, 4 dia. holes 25 25 max. 12.5 10 20 max. Two, 2-dia. holes 14.5 max. 1.5 max. Terminal Arrangement/ Internal Connections (Bottom View) 0.4 250.5 0.7 0.7 + 100.5 12.50.5 Input voltage 3 1 + (+) Input - Load Load power supply Load - (-) 4 2 (+) (-) Note: Values in parentheses apply to the DC-load versions. Vertical Model G3CN-20@P1-US/-20@PL1-US/-DX0@P1-US Two, 2-dia. holes 33 max. Four 1.2-dia. holes Pattern 14 max. Pattern (17.5) 27.5 5 5 Terminal Arrangement/ Internal Connections (Bottom View) Input voltage 26.5 max. 32 max. 1.5 max. - (-) (+) Load 4 50.5 Load power supply + (17.5) 27.50.5 0.7 50.5 0.4 31 - 3 + Input 2 1 (-) (+) Load Note: Values in parentheses apply to the DC-load versions. Solid State Relays G3CN 253 Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Protective Component Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K063-E1-04 254 In the interest of product improvement, specifications are subject to change without notice. Solid State Relays G3CN Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE OMRON ARGENTINA * SALES OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 * www.omron247.com Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE OMRON CHILE * SALES OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com 54.11.4783.5300 (c) 2009 Omron Electronics LLC Cat. No. K063-E1-04 Specifications are subject to change without notice. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3CN-202PL-3-US DC12 G3CN-203P-US DC3-28