LS Series * SIP SSR * Ratings to 12A @ 280 VAC * SCR output for heavy industrial loads * DC control * Zero-crossing (resistive loads) or random-fire (inductive loads) output PRODUCT SELECTION Control Voltage 4-10 VDC 20-28 VDC 8A 12A LS240D8 LSE240D8 LS240D12 LSE240D12 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (2) Maximum Load Current [Arms](3) Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [C/W] Minimum Power Factor (with Maximum Load) LS240D8 LS240D12 24-280 600 0.1 500 8 0.15 80 1.6 2.2 0.5 24-280 600 0.1 500 12 0.15 120 1.6 2.0 0.5 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn On Voltage Minimum Turn-Off Voltage Typical Input Current @ Nominal Voltage Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] LS LSE 4-10 VDC 4.0 VDC 1.0 VDC 15 mAdc 270 Ohm 1/2 Cycle 1/2 Cycle 20-28 VDC 20 VDC 1.0 VDC 15 mAdc 1500 Ohm 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Parameters 2500 Vrms 10 9 Ohm 10pF -30 to 80C -30 to 125C 0.6 oz. (17g) Therminally Conductive Epoxy GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 WIRING DIAGRAM 3) See current derating curve. MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS E116950 LR816889 (For 12A models only) R72060707 Rev. 111611 ANNEX - ENVIROMENTAL INFORMATION