Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Overview Applications The R46 series is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material that meets the requirements of UL 94 V-0. For worldwide use in electromagnetic interference (EMI) suppression in across-the-line applications that require X2 safety classification. Intended for use in situations in which capacitor failure would not result in exposure to electric shock. Not for use in "series with mains" type applications. Benefits * Approvals: ENEC, UL, cUL, CQC * X2 CLASS (IEC 60384-14) * Rated voltage: 310 VAC 50/60 Hz * Capacitance range: 0.01 - 10 F * Lead spacing: 10.0 - 37.5 mm * Capacitance tolerance: 20%, 10% * Climatic category 40/110/56, IEC 60068-1 * Tape & Reel in accordance with IEC 60286-2 * RoHS compliant and lead-free terminations * Operating temperature range of -40C to +110C * 100% screening factory test at 2,200 VDC/1,500 VAC * Self healing properties Click image above for interactive 3D content Open PDF in Adobe Reader for full functionality Part Number System R46 3 N 3150 00 01 M Series Rated Voltage (VAC) Lead Spacing (mm) Capacitance Code (pF) Packaging Internal Use Capacitance Tolerance See Ordering Options Table 01 02 L2 M1 M2 N0 N1 N2 X2, Metallized Polypropylene 3 = 310 F = 10.0 I = 15.0 N = 22.5 R = 27.5 W = 37.5 The last three digits represent significant figures. The first digit specifies number of zeros to be added. K = 10% M = 20% Built Into Tomorrow (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 1 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Ordering Options Table Lead Spacing Nominal (mm) 10 15 22.5 27.5 37.5 Type of Leads and Packaging Lead Length (mm) Lead and Packaging Code Standard Lead and Packaging Options Bulk (Bag) - Short Leads Ammo Pack Other Lead and Packaging Options 4 +2/-0 H0 = 18.5 0.5 00 DQ Tape & Reel (Large Reel) H0 = 18.5 0.5 CK Bulk (Bag) - Short Leads 2.7 +0.5/-0 JA Bulk (Bag) - Short Leads 3.5 +0.5/-0 JB Bulk (Bag) - Short Leads 4.0 +0.5/-0 JE Bulk (Bag) - Short Leads 3.2 +0.3/-0.2 JH Bulk (Bag) - Long Leads 18 1 JM Bulk (Bag) - Long Leads 30 +5/-0 40 Bulk (Bag) - Long Leads 25 +2/-1 50 Bulk (Bag) - Insulated Rigid Leads 30 +5/-0 (sp 8 2) 51 Bulk (Bag) - Insulated Flexible Leads 150 5 (sp 8 2) 52 4 +2/-0 H0= 18.5 0.5 00 CK1 2.7 +0.5/-0 3.5 +0.5/-0 4.0 +0.5/-0 3.2 +0.3/-0.2 18 1 30 +5/-0 25 +2/-1 30 +5/-0 (sp 8 2) 150 5 (sp 8 2) JA JB JE JH JM 40 50 51 52 4 +2/-0 00 2.7 +0.5/-0 3.5 +0.5/-0 4.0 +0.5/-0 3.2 +0.3/-0.2 18 1 JA JB JE JH JM 30 +5/-0 25 +2/-1 30 +5/-0 (sp 8 2) 150 5 (sp 8 2) 40 50 51 52 Standard Lead and Packaging Options Bulk (Bag) - Short Leads Tape & Reel (Large Reel) Other Lead and Packaging Options Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Long Leads Bulk (Tray) - Long Leads Bulk (Tray) - Long Leads Bulk (Bag) - Insulated Rigid Leads Bulk (Bag) - Insulated Flexible Leads Standard Lead and Packaging Options Bulk (Tray) - Short Leads Other Lead and Packaging Options Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Short Leads Bulk (Tray) - Long Leads Bulk (Tray) - Long Leads Bulk (Tray) - Long Leads Bulk (Bag) - Insulated Rigid Leads Bulk (Bag) - Insulated Flexible Leads 1 Not for all sizes, see "Packaging Quantities" table. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 2 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Dimensions - Millimeters Loose Insulated Rigid Leads Insulated Flexible Leads 0.5 mm2 FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW L T L T L T H H S LL S T H 8 2 8 2 OF 150 5 35 +0/-5 F H L F Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance 10.0 10.0 10.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 22.5 22.5 22.5 22.5 22.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 4.0 5.0 6.0 5.0 6.0 6.0 7.5 7.5 8.5 9.0 10.0 11.0 13.0 6.0 7.0 10.0 11.0 13.0 9.0 11.0 13.0 13.0 14.0 18.0 22.0 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.2/-0.7 +0.2/-0.7 +0.2/-0.7 +0.2/-0.7 +0.2/-0.7 +0.2/-0.7 +0.2/-0.7 9.0 11.0 12.0 11.0 12.0 17.5 13.5 18.5 14.5 12.5 16.0 19.0 12.0 15.0 16.0 18.5 20.0 22.0 17.0 20.0 22.0 25.0 28.0 33.0 37.0 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.5 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 13.0 13.0 13.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 26.5 26.5 26.5 26.5 26.5 32.0 32.0 32.0 32.0 32.0 32.0 32.0 +0.2/-0.5 +0.2/-0.5 +0.2/-0.5 +0.3/-0.5 +0.3/-0.5 +0.3/-0.5 +0.5/-0.5 +0.5/-0.5 +0.5/-0.5 +0.5/-0.5 +0.5/-0.5 +0.5/-0.5 +0.5/-0.5 +0.3/-0.5 +0.3/-0.5 +0.3/-0.5 +0.3/-0.5 +0.3/-0.5 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0.6 0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 Note: See Ordering Options Table for lead length (LL/H 0) options. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 3 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Dimensions - Millimeters cont. Loose Insulated Rigid Leads Insulated Flexible Leads 0.5 mm2 FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW L T L T L T H H S LL S T H 8 2 8 2 OF 150 5 35 +0/-5 F H L F Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance 37.5 37.5 37.5 37.5 37.5 37.5 37.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 11.0 13.0 16.0 19.0 20.0 24.0 30.0 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 22.0 24.0 28.5 32.0 40.0 44.0 45.0 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 +0.1/-0.7 41.5 41.5 41.5 41.5 41.5 41.5 41.5 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 +0.3/-0.7 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.05 0.05 0.05 0.05 0.05 0.05 0.05 Note: See Ordering Options Table for lead length (LL/H 0) options. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 4 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Performance Characteristics Dielectric Plates Winding Leads Protection Related Documents Rated Voltage VR Recommended DC Voltage Polypropylene film Metal layer deposited by evaporation under vacuum Non-inductive type Tinned wire Plastic case, thermosetting resin filled. Box material is solvent resistant and flame retardant according to UL94. IEC 60384-14, EN 60384-14 310 VAC (50/60 Hz) 630 VDC Capacitance Range 0.010 - 10 F Capacitance Values E6 series (IEC 60063) measured at 1 kHz and +20 1C Capacitance Tolerance Temperature Range Climatic Category 10%, 20% -40C to +110C 40/110/56 IEC 60068-1 Storage time: 24 months from the date marked on the label package Average relative humidity per year 70% Storage Conditions RH 85% for 30 days randomly distributed throughout the year Dew is absent Temperature: -40 to 80C (see "Maximum Humidity in Storage Conditions" graph below) Approvals Dissipation Factor (tan) Test Voltage Between Terminals ENEC, UL, cUL, CQC 0.1% (0.06%*) at 1 kHz , +25C 5C (* typical value) The 100% screening factory test is carried out at 2,200 VDC/1,500 VAC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. This test cannot be repeated, as there is a risk of damaging the capacitor. KEMET is not liable in such cases for any failures. Measured at +25C 5C, according to IEC 60384-2 Insulation Resistance Minimum Values Between Terminals Voltage Charge 100 VDC Voltage Charge Time C 0.33 F C > 0.33 F 1 minute 1 * 10 M ( 5 * 105 M )* 30,000 M * F ( 150,000 M * F )* 5 * Typical value (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 5 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Performance Characteristics cont. Maximum Humidity in Storage Condition 100 90 80 20 70 60 Tlim (C) Relative Humidity (%) Maximum Overtemperature Tlim vs Th 25 50 40 30 Days Annual Average 30 20 10 5 10 0 15 0 -40 -20 0 20 Temperature (C) 40 60 80 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 Temperature Th(C) Maximum Irms vs. Th 120% Maximum Irms 100% 80% 60% 40% 20% 0% 40 45 50 55 60 65 70 75 80 85 Temperature Th(C) 90 95 100 105 110 115 Th is the maximum ambient temperature surrounding the capacitor or hottest contact point (e.g. tracks), whichever is higher, in the worst operation conditions in C. Impedance Graph (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 6 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Maximum Voltage (Vrms) Versus Frequency (Sinusoidal Waveform/Th 70C) Lead Spacing 15 mm Lead Spacing 10 mm 100 100 0.01 F 0.047 F 0.068 F 0.1 F 10 1 Voltage (Vrms) 1,000 Voltage (Vrms) 1,000 0.1 1.0 Frequency (kHz) 10.0 0.01 F 0.047 F 0.1 F 0.15 F 0.22 F 0.33 F 0.47 F 10 1 100.0 0.1 1.0 Lead Spacing 22.5 mm 100 1 0.1 Voltage (Vrms) 100 Voltage (Vrms) 1,000 10 F F F F F 1.0 Frequency (kHz) 10.0 10.0 100.0 Lead Spacing 27.5 mm 1,000 0.15 0.33 0.47 0.68 1 Frequency (kHz) 100.0 0.47 1 1.5 2.2 4.7 10 1 0.1 F F F F F 1.0 Frequency (kHz) 10.0 100.0 Lead Spacing 37.5 mm 1,000 Voltage (Vrms) 100 1.5 2.2 4.7 6.8 10 10 1 0.1 F F F F F 1.0 Frequency (kHz) 10.0 100.0 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 7 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Maximum Current (Irms) Versus Frequency (Sinusoidal Waveform/Th 70C) Lead Spacing 15 mm Lead Spacing 10 mm 10 1 1 Current (Arms) Current (Arms) 10 0.1 0.01 0.1 0.01 F 0.047 F 0.068 F 0.1 F 0.1 1.0 Frequency (kHz) 10.0 100.0 0.01 0.01 F 0.047 F 0.1 F 0.15 F 0.22 F 0.33 F 0.47 F 0.1 1.0 Lead Spacing 22.5 mm 1 Current (Arms) 1 Current (Arms) 10 0.01 0.15 F 0.33 F 0.47 F 0.68 F 1 F 0.1 1.0 Frequency (kHz) 10.0 100.0 Lead Spacing 27.5 mm 10 0.1 Frequency (kHz) 10.0 0.47 F 1 F 1.5 F 2.2 F 4.7 F 0.1 100.0 0.01 0.1 1.0 Frequency (kHz) 10.0 100.0 Lead Spacing 37.5 mm 10 1 Current (Arms) 1.5 2.2 4.7 6.8 10 F F F F F 0.1 0.01 0.1 1.0 Frequency (kHz) 10.0 100.0 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 8 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Environmental Test Data Test IEC Publication Procedure Endurance EN/IEC 60384-14 Vibration IEC 60068-2-6 Test Fc 3 directions at 2 hours each 10 - 55 Hz at 0.75 mm or 98 m/s2 Bump IEC 60068-2-29 Test Eb 1,000 bumps at 390 m/s2 Change of Temperature IEC 60068-2-14 Test Na Upper and lower rated temperature 5 cycles Active Flammability IEC 60384-14 VR + 20 surge pulses at 2.5 kV (pulse every 5 seconds) Passive Flammability IEC 60384-14 IEC 60384-1, IEC 60695-11-5 Needle flame test Damp Heat Steady State IEC 60068-2-78 Test Cab 1.25 x VR VAC 50 Hz, once every hour increase to 1,000 VAC for 0.1 second, 1,000 hours at upper rated temperature +40C and 93% RH, 56 days Approvals Certification Body Mark Specification File Number IMQ S-p.A. EN/IEC 60384-14 V4413 UL UL 60384-14 and CAN/CSA E60384-14 (310 VAC) E97797 GB/T 14472 IEC 60384-14 CQC08001026549 CQC11001060118 CQC13001087757 CQC14001116028 CQC13001101266 CQC14001116000 CQC Environmental Compliance All KEMET EMI capacitors are RoHS compliant. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 9 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Table 1 - Ratings & Part Number Reference Dimensions in mm Capacitance Value (F) T H 0.010 0.015 0.022 0.033 0.047 0.068 0.10 0.010 0.015 0.022 0.033 0.047 0.068 0.10 0.15 0.15 0.22 0.22 0.22 0.33 0.33 0.33 0.33 0.47 0.47 0.56 0.60 0.15 0.22 0.33 0.47 0.68 1.0 1.0 1.5 0.47 0.68 1.0 1.5 2.2 2.2 3.3 4.7 4.7 1.5 2.2 2.2 3.3 4.7 4.7 6.8 6.8 10.0 4.0 4.0 4.0 5.0 5.0 6.0 6.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 6.0 9.0 7.5 9.0 6.0 8.5 10.0 7.5 13.0 10.0 11.0 11.0 11.0 6.0 6.0 6.0 7.0 10.0 10.0 11.0 13.0 9.0 9.0 11.0 13.0 13.0 14.0 18.0 18.0 22.0 11.0 11.0 13.0 16.0 16.0 19.0 20.0 24.0 30.0 9.0 9.0 9.0 11.0 11.0 12.0 12.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 12.0 12.5 13.5 12.5 17.5 14.5 16.0 18.5 12.0 16.0 19.0 19.0 19.0 15.0 15.0 15.0 16.0 18.5 18.5 20.0 22.0 17.0 17.0 20.0 22.0 25.0 28.0 33.0 33.0 37.0 22.0 22.0 24.0 28.5 28.5 32.0 40.0 44.0 45.0 Capacitance Value (F) T (mm) H (mm) L Lead Spacing (S) dV/dt (V/s) KEMET Part Number Legacy Part Number 13.0 13.0 13.0 13.0 13.0 13.0 13.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0 41.5 41.5 41.5 41.5 41.5 41.5 41.5 41.5 41.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 27.5 37.5 37.5 37.5 37.5 37.5 37.5 37.5 37.5 37.5 500 500 500 500 500 500 500 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 200 200 200 200 200 200 200 200 150 150 150 150 150 150 150 150 150 100 100 100 100 100 100 100 100 100 463F2100(1)N0(2) 463F2150(1)N0(2) 463F2220(1)N0(2) 463F2330(1)M1(2) 463F2470(1)N0(2) 463F2680(1)M1(2) 463F3100(1)M1(3) 463I2100(1)01(2) 463I2150(1)01(2) 463I2220(1)01(2) 463I2330(1)01(2) 463I2470(1)01(2) 463I2680(1)01(2) 463I3100(1)M1(2) 463I3150(1)M2(2) 463I3150(1)L2(2) 463I3220(1)M2(2) 463I3220(1)L2(2) 463I3220(1)02(2) 463I3330(1)N0(2) 463I3330(1)M1(2) 463I3330(1)02(2) 463I3330(1)01(2) 463I3470(1)N0(3) 463I3470(1)M1(2) 463I3560(1)N0(2) 463I3600(1)N0(2) 463N3150(1)01(2) 463N3220(1)M1(2) 463N3330(1)N0(2) 463N3470(1)N0(2) 463N3680(1)M2(2) 463N4100(1)N2(3) 463N4100(1)N1(2) 463N4150(1)N1(2) 463R3470(1)01(2) 463R3680(1)M1(2) 463R4100(1)M1(2) 463R4150(1)M1(2) 463R4220(1)M2(2) 463R4220(1)M1(2) 463R4330(1)M2(2) 463R4470(1)M2(2) 463R4470(1)M1(2) 463W4150(1)M1(2) 463W4220(1)M2(3) 463W4220(1)M1(2) 463W4330(1)M1(2) 463W4470(1)M2(3) 463W4470(1)M1(2) 463W4680(1)M2(2) 463W4680(1)M1(2) 463W5100(1)M1(2) R463F2100(1)N0(2) R463F2150(1)N0(2) R463F2220(1)N0(2) R463F2330(1)M1(2) R463F2470(1)N0(2) R463F2680(1)M1(2) R463F3100(1)M1(3) R463I2100(1)01(2) R463I2150(1)01(2) R463I2220(1)01(2) R463I2330(1)01(2) R463I2470(1)01(2) R463I2680(1)01(2) R463I3100(1)M1(2) R463I3150(1)M2(2) R463I3150(1)L2(2) R463I3220(1)M2(2) R463I3220(1)L2(2) R463I3220(1)02(2) R463I3330(1)N0(2) R463I3330(1)M1(2) R463I3330(1)02(2) R463I3330(1)01(2) R463I3470(1)N0(3) R463I3470(1)M1(2) R463I3560(1)N0(2) R463I3600(1)N0(2) R463N3150(1)01(2) R463N3220(1)M1(2) R463N3330(1)N0(2) R463N3470(1)N0(2) R463N3680(1)M2(2) R463N4100(1)N2(3) R463N4100(1)N1(2) R463N4150(1)N1(2) R463R3470(1)01(2) R463R3680(1)M1(2) R463R4100(1)M1(2) R463R4150(1)M1(2) R463R4220(1)M2(2) R463R4220(1)M1(2) R463R4330(1)M2(2) R463R4470(1)M2(2) R463R4470(1)M1(2) R463W4150(1)M1(2) R463W4220(1)M2(3) R463W4220(1)M1(2) R463W4330(1)M1(2) R463W4470(1)M2(3) R463W4470(1)M1(2) R463W4680(1)M2(2) R463W4680(1)M1(2) R463W5100(1)M1(2) L (mm) Lead Spacing (S) dV/dt (V/s) KEMET Part Number Legacy Part Number (1) Insert lead and packaging code. See Ordering Options Table for available options. (2) M = 20%, K = 10% (3) M = 20% (only available tolerance). (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 10 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Soldering Process The implementation of the RoHS directive has resulted in the selection of SnAuCu (SAC) alloys or SnCu alloys as primary solder material. This has increased the liquidus temperature from 183C for SnPb eutectic alloys to 217 - 221C for the new alloys. As a result, the heat stress to the components, even in wave soldering, has increased considerably due to higher preheat and wave temperatures. Polypropylene capacitors are especially sensitive to heat (the melting point of polypropylene is 160 - 170C). Wave soldering can be destructive, especially for mechanically small polypropylene capacitors (with lead spacing of 5 - 15 mm). Great care must be taken during soldering. The recommended solder profiles from KEMET should be used. Consult KEMET with any questions. In general, the wave soldering curve from IEC Publication 61760-1 Edition 2 serves as a solid guideline for successful soldering. See Figure 1. Reflow soldering is not recommended for through-hole film capacitors. Exposing capacitors to a soldering profile in excess of the above-recommended limits may result to degradation of or permanent damage to the capacitors. Do not place the polypropylene capacitor through an adhesive curing oven to cure resin for surface mount components. Insert through-hole parts after curing surface mount parts. Consult KEMET to discuss the actual temperature profile in the oven, if through-hole components must pass through the adhesive curing process. A maximum two soldering cycles is recommended. Allow time for the capacitor surface temperature to return to normal temperature before performing the second soldering cycle. Wave Soldering Recommendations Manual Soldering Recommendations Following is the recommendation for manual soldering with a soldering iron. 300 Second Wave First Wave Recommended Soldering Temperature 200 Temperature (C) 400 350 Soldering Iron Bit Temperature (C) 2+3 seconds max 260C 250 300 250 T < 150C Cooling Preheating 150 ca. 2C/second ca. 3.5C/second typical ca. 5C/second Tpreheat 100 Typical 200 50 150 100 0 50 0 40 80 120 160 200 240 Time (seconds) 0 0 1 2 3 4 5 6 7 8 Soldering Time (seconds) The soldering iron tip temperature should be set at 350C (+10C maximum), with the soldering duration not to exceed more than 3 seconds. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 11 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Soldering Process cont. Wave Soldering Recommendations cont. 1. The table indicates the maximum set-up temperature of the soldering process. Dielectric Film Material Maximum Preheat Temperature Maximum Peak Soldering Temperature Capacitor Capacitor Capacitor Capacitor Pitch Pitch Pitch Pitch 15 mm > 15 mm 15 mm > 15 mm Polyester 130C 130C 270C 270C Polypropylene 110C 130C 260C 270C Paper 130C 140C 270C 270C Polyphenylene Sulphide 150C 160C 270C 270C 2. The maximum temperature measured inside the capacitor: set the temperature so that the maximum temperature inside the element is below the limit. Dielectric Film Material Maximum Temperature Measured Inside the Element Polyester 160C Polypropylene 110C Paper 160C Polyphenylene Sulphide 160C Temperature monitored inside the capacitor. Selective Soldering Recommendations Selective dip soldering is a variation of reflow soldering. In this method, the printed circuit board with through-hole components to be soldered is preheated and transported over the solder bath as it is in normal flow soldering, without touching the solder. When the board is over the bath, it is stopped. Pre-designed solder pots are lifted from the bath with molten solder, only at the places of the selected components, and pressed against the lower surface of the board to solder the components. The temperature profile for selective soldering is similar to the double wave flow soldering outlined in this document. However, instead of two baths, there is only one with a time from 3 - 10 seconds. In selective soldering, the risk of overheating is greater than in double wave flow soldering, and great care must be taken so that the parts do not overheat. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 12 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Construction Molded Plastic Case Single-sided Metallized Polypropylene Film (First Layer) Detailed Cross Section Molded Plastic Self-Extinguishing Case Resin Single-sided Metallized Polypropylene Film (Second Layer) Margin Margin Metal Contact Layer Metal Contact Layer Margin FILM WINDING SCHEME OPTIONS Leads Single-sided Metallized Polypropylene Film Double-sided Winding Scheme Single-sided Metallized Polypropylene Film 1 Section Single-sided Metallized Polypropylene Film Double-sided Metallized Polyester Carrier Film 2 Sections Single-sided Metallized Polypropylene Film Polypro Film Die 1 Section Single-sided Metallized Polypropylene Film 3 Sections 4 Sections Metallized Impregnated Paper Metallized Polyphenylene (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Sulfide Film (SMR) Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com Double-sided Metallized Polyester Carrier Film Polyprop Film Die 3 Sections KEM_F3095_R46_X2_310_110C * 11/3/2020 13 Polyp Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Marking Lead Spacing 10 mm FRONT TOP Series, Dielectric Code, Safety Class, Self Healing Capacitance, Rated Voltage Approval Marks Manufacturer's Logo IEC Climatic Category Capacitance Tolerance Date Code Passive Flammability Category: C for volume < 1750 mm3 Manufacturing Plant NOTE: Hot imprinting with or without color or ink jet or laser marking Lead Spacing 15 mm, 22.5 mm, and 27.5 mm FRONT TOP Series, Dielectric Code, Safety Class, Self Healing Capacitance, Rated Voltage Approval Marks Manufacturer's Logo IEC Climatic Category Capacitance Tolerance Date Code Passive Flammability Category: B for volume 1750 mm3 C for volume < 1750 mm3 Manufacturing Plant NOTE: Hot imprinting with or without color or ink jet or laser marking Lead Spacing 22.5 and 27.5 mm (alternatives*) and 37.5 mm FRONT TOP Series Dielectric Safety Code Class Approval Marks Manufacturer's Logo IEC Climatic Category (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com Self Healing Capacitance, Capacitance Tolerance, Rated Voltage QA Number Passive Manufacturing Date Code Flammability KEM_F3095_R46_X2_310_110C * 11/3/2020 Plant Category 14 Date Code Category Manufacturing Plant Passive Flammability Metallized Polypropylene Film EMI Suppression Capacitors Category: R46, Class X2, 310 VAC, 110C B for volume 1750 mm3 C for volume < 1750 mm3 NOTE: Hot imprinting with or without color or ink jet or laser marking Marking cont. Lead Spacing 22.5 and 27.5 mm (alternatives*) and 37.5 mm FRONT TOP Series Dielectric Safety Code Class Self Healing Capacitance, Capacitance Tolerance, Rated Voltage Manufacturer's Logo Approval Marks IEC Climatic Category QA Number Passive Flammability Category Manufacturing Plant Date Code *Differences are caused by technology (clichee, laser, or ink) and production line. Manufacturing Date Code (IEC-60062) Y = Year, Z = Month Year Code Month Code 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 A B C D E F H J K L M N P R S T U V W X A January February March April May June July August September October November December 1 2 3 4 5 6 7 8 9 O N D (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 15 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Packaging Quantities Lead Spacing (mm) Thickness (mm) Height (mm) Length (mm) Bulk Short Leads Bulk Long Leads Standard Reel o 355 mm Large Reel o 500 mm Ammo Taped 10 4 5 6 9 11 12 13 13 13 2,000 1,300 1,000 1,800 1,500 1,200 750 600 500 1,500 1,250 1,000 1,000 800 680 15 5 6 6 7.5 7.5 8.5 9 10 11 13 11 12 17.5 13.5 18.5 14.5 12.5 16 19 12 18 18 18 18 18 18 18 18 18 18 2,000 1,750 1,000 1,000 900 1,000 1,000 750 450 750 1,000 900 700 700 500 500 520 500 350 490 600 500 500 350 - 300 270 300 - 200 1,250 1,000 1,000 800 800 700 650 600 500 480 800 680 680 500 500 440 410 380 340 280 22.5 6 7 10 11 13 15 16 18.5 20 22 26.5 26.5 26.5 26.5 26.5 805 700 396 360 300 500 500 300 250 200 - - - - - 700 550 350 350 300 464 380 235 217 - 27.5 9 11 13 13 14 18 22 17 20 22 25 28 33 37 32 32 32 32 32 32 32 816 560 480 480 352 256 168 408 336 288 288 176 128 112 - - - - - - - 450 350 300 - - - - - - - - - - - 37.5 11 13 16 19 20 24 30 22 24 28.5 32 40 44 45 41.5 41.5 41.5 41.5 41.5 41.5 41.5 420 360 216 192 126 108 90 252 216 108 96 84 72 60 - - - - - - - - - - - - - - - - - - - - - (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 16 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Lead Taping & Packaging (IEC 60286-2) Figure 1 Lead Spacing 10 mm Figure 2 Lead Spacing 15 mm Figure 3 Lead Spacing 22.5 - 27.5 mm P W2 P2 od A B W W0 W1 H0 P1 P0 F P h h D0 P1 P2 A-B t Taping Specification Dimensions (mm) Description Symbol 10 Fig. 1 Lead Space 15 22.5 Fig. 2 Fig. 3 27.5 Fig. 3 Tol. Lead wire diameter d 0.6 0.6-0.8 0.8 0.8 0.05 Taping lead space P 25.4 25.4 38.1 38.1 1 Feedholeleadspace* P0 12.7 12.7 12.7 12.7 0.2** Centering of the lead wire P1 7.7 5.2 7.8 5.3 0.7 Centeringofthebody P2 12.7 12.7 19.05 19.05 1.3 Leadspacing(pitch)*** F 10 15 22.5 27.5 +0.6/-0.1 Component alignment h 0 0 0 0 2 Height of component from tape center H 0**** 18.5 18.5 18.5 18.5 0.5 Carrier tape width W 18 18 18 18 +1/-0.5 Hold down tape width W0 9 10 10 10 Minimum Hole position W1 9 9 9 9 0.5 Hold down tape position W2 3 3 3 3 Maximum Feed hole diameter D0 4 4 4 4 0.2 Total tape thickness t 0.7 0.7 0.7 0.7 0.2 * 15 mm also available ** Maximum of 1 mm on 20 lead spaces *** Pitches 15 mm and 10 mm taped to 7.5 mm (crimped leads) available upon request **** H0 = 16.5 mm is available upon request (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 17 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C Lead Taping & Packaging (IEC 60286-2) cont. Ammo Specifications Dimensions (mm) H W T 360 340 59 H T W Reel Specifications Reel Size Standard Large Dimensions (mm) D H W 355 500 30 25 55Maximum D H W (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 18 Metallized Polypropylene Film EMI Suppression Capacitors R46, Class X2, 310 VAC, 110C KEMET Electronics Corporation Sales Offices Foracompletelistofourglobalsalesoffices,pleasevisitwww.kemet.com/sales. Disclaimer Allproductspecifications,statements,informationanddata(collectively,the"Information")inthisdatasheetaresubjecttochange.Thecustomerisresponsiblefor checkingandverifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced.AllInformationgiven hereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation's("KEMET")knowledgeoftypicaloperatingconditionsforsuch applications,butarenotintendedtoconstitute-andKEMETspecificallydisclaims-anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse. TheInformationisintendedforuseonlybycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.Any technicaladviceinferredfromthisInformationorotherwiseprovidedbyKEMETwithreferencetotheuseofKEMET'sproductsisgivengratis,andKEMETassumes noobligationorliabilityfortheadvicegivenorresultsobtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failuresmaystilloccur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards (suchasinstallationofprotectivecircuitryorredundancies)inordertoensurethatthefailureofanelectricalcomponentdoesnotresultinariskofpersonalinjury or property damage. Althoughallproduct-relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatother measuresmaynotberequired. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com KEM_F3095_R46_X2_310_110C * 11/3/2020 19