Resistance to fast transients 2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for input conforming to EN/IEC 61000-4-4
1 kV for transistor output conforming to EN/IEC 61000-4-4
Resistance to conducted disturbances 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine
specification (LR, ABS, DNV, GL)
Electromagnetic emission Conducted emissions, test level: 120...69 dBµV/m QP, condition of test: power lines (radio frequency:
10...150 kHz) conforming to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency:
1.5...30 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio
frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio
frequency: 0.5...300 MHz) conforming to EN/IEC 55011
Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency:
30...230 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency:
150...1500 kHz) conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency:
230...1000 MHz) conforming to EN/IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for operation -10...55 °C for horizontal installation
-10...50 °C for vertical installation
Ambient air temperature for storage -25...70 °C
Relative humidity 10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection IP20 with protective cover in place
Pollution degree 2
Operating altitude 0...2000 m
Storage altitude 0...3000 m
Vibration resistance 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
3 gn (vibration frequency: 8.4...150 Hz) on panel mounting
Shock resistance 15 gn for 11 ms
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1350 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference contains SVHC above the threshold - Go to CaP for more details
Go to CaP for more details
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information