Product datasheet
Characteristics
TM241CE40R
controller M241 40 IO relay Ethernet
Price* : 422.00 GBP
Main
Range of product Modicon M241
Product or component type Logic controller
[Us] rated supply voltage 100...240 V AC
Discrete input number 24 discrete input including 8 fast input conforming to IEC 61131-2 Type 1
Discrete output type Relay
Transistor
Discrete output number 12 relay
4 transistor including 4 fast output
Discrete output voltage 24 V DC for transistor output
5...125 V DC for relay output
5...250 V AC for relay output
Discrete output current 0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
2 A with Q4...Q15 terminal(s) for relay output
0.5 A with TR0...TR3 terminal(s) for transistor output
Complementary
Discrete I/O number 40
Number of I/O expansion module 7 (local I/O architecture)
14 (remote I/O architecture)
Supply voltage limits 85...264 V
Network frequency 50/60 Hz
Discrete input logic Sink or source
Discrete input voltage 24 V
Discrete input voltage type DC
Voltage state 1 guaranteed >= 15 V for input
Voltage state 0 guaranteed <= 5 V for input
Discrete input current 7 mA for input
Input impedance 4.7 kOhm for input
Response time 50 µs turn-on operation with I0...I15 terminal(s) for input
Configurable filtering time 1 µs for fast input
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Mar 14, 2019
1
Discrete output logic Positive logic (source)
Output voltage limits 125 V DC relay output
30 V DC transistor output
277 V AC relay output
Output frequency <= 1 kHz for transistor output
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode)
Accuracy +/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output
Protection type Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output
Reverse polarity protection for transistor output
Without protection for relay output
Reset time 10 ms automatic reset output
12 s automatic reset fast output
Memory capacity 8 MB for program
64 MB for system memory RAM
Data backed up 128 MB built-in flash memory for backup of user programs
Data storage equipment <= 16 GB SD card optional
Battery type BR2032 lithium non-rechargeable, battery life: 4 yr
Backup time 2 years at 25 °C
Execution time for 1 KInstruction 0.3 ms for event and periodic task
0.7 ms for other instruction
Application structure 8 event tasks
4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task
8 external event tasks
Realtime clock With
Clock drift <= 60 s/month at 25 °C
Positioning functions PTO function 4 channel(s) (positioning frequency: 100 kHz)
Counting input number 4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz
Control signal type A/B signal at 100 kHz for fast input (HSC mode)
Pulse/Direction signal at 200 kHz for fast input (HSC mode)
Single phase signal at 200 kHz for fast input (HSC mode)
Integrated connection type USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485
Supply Serial link supply "serial 1" at 5 V, <= 200 mA
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
480 Mbit/s for bus length of 3 m - communication protocol: USB
10/100 Mbit/s - communication protocol: Ethernet
Communication port protocol Modbus non isolated serial link with master/slave method
Port Ethernet 1 - 10BASE-T/100BASE-TX port with copper cable support
Ethernet services FDR
Downloading
IEC VAR ACCESS
Monitoring
NGVL
Programming
Updating firmware
SMS notifications
DHCP server (via TM4 Ethernet switch network module)
DHCP client (embedded Ethernet port)
SNMP client/server
FTP client/server
SQL client
Modbus TCP client I/O scanner
Ethernet/IP originator I/O scanner (embedded Ethernet port)
Ethernet/IP target, Modbus TCP server and Modbus TCP slave
Send and receive email from the controller based on TCP/UDP library
Web server (WebVisu & XWeb system)
OPC UA server
2
DNS client
Local signalling 1 LED green for SD card access (SD)
1 LED red for BAT
1 LED green for SL1
1 LED green for SL2
1 LED per channel green for I/O state
1 LED red for I/O error (I/O)
1 LED red for bus fault on TM4 (TM4)
1 LED green for Ethernet port activity
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
Electrical connection Removable screw terminal block for inputs and outputs (pitch 5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm)
Cable distance between devices Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input
Unshielded cable: <= 50 m for output
Shielded cable: <= 3 m for fast output
Insulation 500 V AC between supply and internal logic
Non-insulated between supply and ground
Marking CE
Sensor power supply 24 V DC at 400 mA supplied by the controller
Surge withstand 2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
1 kV for input in common mode conforming to EN/IEC 61000-4-5
1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5
Web services Web server
Maximum number of connections 8 connection(s) for Modbus server
8 connection(s) for SoMachine protocol
10 connection(s) for web server
4 connection(s) for FTP server
16 connection(s) for Ethernet/IP target
8 connection(s) for Modbus client
Number of slave 16 Ethernet/IP
64 Modbus TCP
Cycle time 10 ms 16 Ethernet/IP
64 ms 64 Modbus TCP
Mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
Height 90 mm
Depth 95 mm
Width 190 mm
Product weight 0.62 kg
Environment
Standards CSA C22.2 No 142
ANSI/ISA 12-12-01
UL 1604
CSA C22.2 No 213
EN/IEC 61131-2 : 2007
Marine specification (LR, ABS, DNV, GL)
UL 508
Product certifications CSA
cULus
IACS E10
RCM
Resistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
3
Resistance to fast transients 2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for input conforming to EN/IEC 61000-4-4
1 kV for transistor output conforming to EN/IEC 61000-4-4
Resistance to conducted disturbances 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine
specification (LR, ABS, DNV, GL)
Electromagnetic emission Conducted emissions, test level: 120...69 dBµV/m QP, condition of test: power lines (radio frequency:
10...150 kHz) conforming to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency:
1.5...30 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio
frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio
frequency: 0.5...300 MHz) conforming to EN/IEC 55011
Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency:
30...230 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency:
150...1500 kHz) conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency:
230...1000 MHz) conforming to EN/IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for operation -10...55 °C for horizontal installation
-10...50 °C for vertical installation
Ambient air temperature for storage -25...70 °C
Relative humidity 10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection IP20 with protective cover in place
Pollution degree 2
Operating altitude 0...2000 m
Storage altitude 0...3000 m
Vibration resistance 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
3 gn (vibration frequency: 8.4...150 Hz) on panel mounting
Shock resistance 15 gn for 11 ms
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1350 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference contains SVHC above the threshold - Go to CaP for more details
Go to CaP for more details
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information
4
Product datasheet
Dimensions Drawings
TM241CE40R
Dimensions
5
Product datasheet
Mounting and Clearance
TM241CE40R
Clearance
6
Product datasheet
Mounting and Clearance
TM241CE40R
Mounting Position
Acceptable Mounting
NOTE: Expansion modules must be mounted above the logic controller.
Incorrect Mounting
7
Product datasheet
Mounting and Clearance
TM241CE40R
Direct Mounting On a Panel Surface
Mounting Hole Layout
8
Product datasheet
Connections and Schema
TM241CE40R
Digital Inputs
Wiring Diagram (Positive Logic)
(*) : Type T fuse
(1) : The COM0, COM1 and COM2 terminals are not connected internally.
Wiring Diagram (Negative Logic)
(*) : Type T fuse
(1) : The COM0, COM1 and COM2 terminals are not connected internally.
9
Product datasheet
Connections and Schema
TM241CE40R
Fast Transistor Outputs
Wiring Diagram
(*) : 2 A fast-blow fuse
10
Product datasheet
Connections and Schema
TM241CE40R
Relay Outputs
Wiring Diagram
(*) : Type T fuse
(1) : The terminals COM1 to COM6 are not connected internally.
(2) : To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load
11
Product datasheet
Connections and Schema
TM241CE40R
USB Mini-B Connection
12
Product datasheet
Connections and Schema
TM241CE40R
Ethernet Connection to a PC
13