TM241CE40R Product datasheet Characteristics controller M241 40 IO relay Ethernet Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Price* : 422.00 GBP Main Range of product Modicon M241 Product or component type Logic controller [Us] rated supply voltage 100...240 V AC Discrete input number 24 discrete input including 8 fast input conforming to IEC 61131-2 Type 1 Discrete output type Relay Transistor Discrete output number 12 relay 4 transistor including 4 fast output Discrete output voltage 24 V DC for transistor output 5...125 V DC for relay output 5...250 V AC for relay output Discrete output current 0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode) 2 A with Q4...Q15 terminal(s) for relay output 0.5 A with TR0...TR3 terminal(s) for transistor output Complementary Discrete I/O number 40 Number of I/O expansion module 7 (local I/O architecture) 14 (remote I/O architecture) Supply voltage limits 85...264 V Network frequency 50/60 Hz Discrete input logic Sink or source Discrete input voltage 24 V Discrete input voltage type DC Voltage state 1 guaranteed >= 15 V for input Voltage state 0 guaranteed <= 5 V for input Discrete input current 7 mA for input Input impedance 4.7 kOhm for input Response time 50 s turn-on operation with I0...I15 terminal(s) for input Configurable filtering time 1 s for fast input Mar 14, 2019 1 Discrete output logic Positive logic (source) Output voltage limits 125 V DC relay output 30 V DC transistor output 277 V AC relay output Output frequency <= 1 kHz for transistor output <= 20 kHz for fast output (PWM mode) <= 100 kHz for fast output (PLS mode) Accuracy +/- 0.1 % at 0.02...0.1 kHz for fast output +/- 1 % at 0.1...1 kHz for fast output Protection type Short-circuit protection for transistor output Short-circuit and overload protection with automatic reset for transistor output Reverse polarity protection for transistor output Without protection for relay output Reset time 10 ms automatic reset output 12 s automatic reset fast output Memory capacity 8 MB for program 64 MB for system memory RAM Data backed up 128 MB built-in flash memory for backup of user programs Data storage equipment <= 16 GB SD card optional Battery type BR2032 lithium non-rechargeable, battery life: 4 yr Backup time 2 years at 25 C Execution time for 1 KInstruction 0.3 ms for event and periodic task 0.7 ms for other instruction Application structure 8 event tasks 4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks Realtime clock With Clock drift <= 60 s/month at 25 C Positioning functions PTO function 4 channel(s) (positioning frequency: 100 kHz) Counting input number 4 fast input (HSC mode) at 200 kHz 14 standard input at 1 kHz Control signal type A/B signal at 100 kHz for fast input (HSC mode) Pulse/Direction signal at 200 kHz for fast input (HSC mode) Single phase signal at 200 kHz for fast input (HSC mode) Integrated connection type USB port with connector mini B USB 2.0 Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 Supply Serial link supply "serial 1" at 5 V, <= 200 mA Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s for bus length of 3 m - communication protocol: USB 10/100 Mbit/s - communication protocol: Ethernet Communication port protocol Modbus non isolated serial link with master/slave method Port Ethernet 1 - 10BASE-T/100BASE-TX port with copper cable support Ethernet services FDR Downloading IEC VAR ACCESS Monitoring NGVL Programming Updating firmware SMS notifications DHCP server (via TM4 Ethernet switch network module) DHCP client (embedded Ethernet port) SNMP client/server FTP client/server SQL client Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner (embedded Ethernet port) Ethernet/IP target, Modbus TCP server and Modbus TCP slave Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server 2 DNS client Local signalling 1 LED green for SD card access (SD) 1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for I/O error (I/O) 1 LED red for bus fault on TM4 (TM4) 1 LED green for Ethernet port activity 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN Electrical connection Removable screw terminal block for inputs and outputs (pitch 5.08 mm) Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) Cable distance between devices Unshielded cable: <= 50 m for input Shielded cable: <= 10 m for fast input Unshielded cable: <= 50 m for output Shielded cable: <= 3 m for fast output Insulation 500 V AC between supply and internal logic Non-insulated between supply and ground Marking CE Sensor power supply 24 V DC at 400 mA supplied by the controller Surge withstand 2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5 2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 Web services Web server Maximum number of connections 8 connection(s) for Modbus server 8 connection(s) for SoMachine protocol 10 connection(s) for web server 4 connection(s) for FTP server 16 connection(s) for Ethernet/IP target 8 connection(s) for Modbus client Number of slave 16 Ethernet/IP 64 Modbus TCP Cycle time 10 ms 16 Ethernet/IP 64 ms 64 Modbus TCP Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit Height 90 mm Depth 95 mm Width 190 mm Product weight 0.62 kg Environment Standards CSA C22.2 No 142 ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) UL 508 Product certifications CSA cULus IACS E10 RCM Resistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-2 8 kV in air conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 3 Resistance to fast transients 2 kV for power lines conforming to EN/IEC 61000-4-4 2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for transistor output conforming to EN/IEC 61000-4-4 Resistance to conducted disturbances 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) Electromagnetic emission Conducted emissions, test level: 120...69 dBV/m QP, condition of test: power lines (radio frequency: 10...150 kHz) conforming to EN/IEC 55011 Conducted emissions, test level: 63 dBV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79 dBV/m QP/66 dBV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 73 dBV/m QP/60 dBV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dBV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emissions, test level: 79...63 dBV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011 Radiated emissions, test level: 47 dBV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 Immunity to microbreaks 10 ms Ambient air temperature for operation -10...55 C for horizontal installation -10...50 C for vertical installation Ambient air temperature for storage -25...70 C Relative humidity 10...95 % without condensation in operation 10...95 % without condensation in storage IP degree of protection IP20 with protective cover in place Pollution degree 2 Operating altitude 0...2000 m Storage altitude 0...3000 m Vibration resistance 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail 3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on panel mounting Shock resistance 15 gn for 11 ms Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1350 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference contains SVHC above the threshold - Go to CaP for more details Product environmental profile Available Go to CaP for more details Product Environmental Profile Product end of life instructions Available End of Life Information 4 Product datasheet Dimensions Drawings TM241CE40R Dimensions 5 Product datasheet Mounting and Clearance Clearance 6 TM241CE40R Product datasheet Mounting and Clearance TM241CE40R Mounting Position Acceptable Mounting NOTE: Expansion modules must be mounted above the logic controller. Incorrect Mounting 7 Product datasheet Mounting and Clearance Direct Mounting On a Panel Surface Mounting Hole Layout 8 TM241CE40R Product datasheet Connections and Schema TM241CE40R Digital Inputs Wiring Diagram (Positive Logic) (*) : (1) : Type T fuse The COM0, COM1 and COM2 terminals are not connected internally. Wiring Diagram (Negative Logic) (*) : (1) : Type T fuse The COM0, COM1 and COM2 terminals are not connected internally. 9 Product datasheet Connections and Schema Fast Transistor Outputs Wiring Diagram (*) : 10 2 A fast-blow fuse TM241CE40R Product datasheet Connections and Schema TM241CE40R Relay Outputs Wiring Diagram (*) : (1) : (2) : Type T fuse The terminals COM1 to COM6 are not connected internally. To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to ea 11 Product datasheet Connections and Schema USB Mini-B Connection 12 TM241CE40R Product datasheet Connections and Schema TM241CE40R Ethernet Connection to a PC 13