General Purpose Panel/Plug-in Relays SCHRACK Multimode Relay MT n2/3 pole 10A, 2 form C (CO) or 3 form C (CO) contacts and AC coils nMechanical indicator as standard nElectrical indicator nNew test system with front operated finger protected push-to-test button and integral locking test tab nWhite write on panel nDC Typical applications Mechanical engineering, plant control. Z Contact Data (continued) Approvals Mechanical endurance DC coil AC coil VDE Cert. No. 40009096, UL E214025 Technical data of approved types on request. Contact Data Contact arrangement 2 form C (CO) or 3 form C (CO) Rated voltage 240VAC Max. switching voltage 400VAC Rated current 10A 10A Limiting making current, max. 20ms 20A 20A Limiting breaking current 10A 10A Switching power 2500VA 2500VA Contact material AgNi90/10 AgNi90/10 - gold plated Contact style single single contact contact Min. recommended contact load 12V 20mV at 10mA at 1mA Initial voltage drop 30mV at 100mA/6VAC/1kHz Frequency of operation, with/without load 1200/6000h-1 Operate time typ, DC coil 15ms Release time typ, DC coil 10ms Bounce time max., DC coil, form A/form B 4/10ms Contact ratings Type Contact Load IEC 61810 MT22 DC coil C (CO) 10A, 250VAC, cos=1, 35C MT22 AC coil C (CO) 10A, 250VAC, cos=1, 35C MT32 DC coil C (CO) 10A, 250VAC, cos=1, 35C MT32 AC coil C (CO) 10A, 250VAC, cos=1, 35C UL 508 MT3 A (NO)/B (NC) B300, 40C MT2 C (CO) 10A, 250VAC, resistive, 40 MT2 A (NO)/B (NC) B300 40C MT3 C (CO) 10A, 250VAC, resistive, 40C Cycles 100x103 20x103 100x103 20x103 6.000 30x103 6.000 100x103 Coil Data Coil voltage range Operative range, IEC 61810 Coil insulation system according UL 20x106 operations 20x106 operations 6 to 220VDC 12 to 230VAC 2 class 130 (B) Coil versions, DC coil Coil code Rated Operate Release Coil Rated coil STD PD3) voltage voltage voltageresistance power VDC VDC VDC 10%1)2)W 006 0A6 6 4.5 0.6 30 1.1 012 0B2 12 9.0 1.2 115 1.3 024 0C4 24 18.0 2.4 475 1.2 048 0E8 48 36.0 4.8 1900 1.2 060 0G0 60 45.0 6.0 2950 1.3 110 1B0 11082.511.5 97001)1.2 220 2C0 220 165.0 22.0 387002)1.2 1) Coil resistance 12%, 2) Coil resistance 15%. 3) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10. All figures are given for coil without pre-energization, at ambient temperature +23C. Coil versions, AC coil, 50/60Hz Coil Rated Operate Release Coil Rated coil codevoltagevoltagevoltage resistancepower 50/60Hz 50/60Hz50/60Hz VACVACVAC 10%1)VA 012 12 9.6/10.2 3.6 24 2.19/1.86 024 24 19.2/20.4 7.2 86 2.26/1.95 048 48 38.4/40.8 14.4 345 2.28/1.97 060 60 48.0/51.0 18.0 544 2.27/1.96 115 115 92.0/97.8 34.5 2000 2.37/2.00 230 230 184.0/195.5 69.0 83001)2.32/1.96 1) Coil resistance 12%. All figures are given for coil without pre-energization, at ambient temperature +23C. 05-2019, Rev. 0219 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 1 General Purpose Panel/Plug-in Relays SCHRACK Multimode Relay MT (Continued) Insulation Data Initial dielectric strength between open contacts 1500Vrms between contact and coil 2500Vrms between adjacent contacts 2500Vrms Clearance/creepage between contact and coil 2.8/4mm between adjacent contacts 2.8/4mm Material group of insulation parts IIIa Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature DC coil -40 to +60C AC coil -40 to +50C Category of environmental protection IEC 61810 RTI - dust protected Vibration resistance (functional), form A (NO)/form B (NC) 5/2g Terminal type plug-in Cover retention, pull/push force 100/100N Weight80g Packaging unit 25 pcs. Accessories For details see datasheet Accessories Multimode Relay MT Note: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1); for relays mounted on sockets deratings may apply. Terminal assignment Dimensions Bottom view on pins 2 05-2019, Rev. 0219 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. General Purpose Panel/Plug-in Relays SCHRACK Multimode Relay MT (Continued) Product code structure Typical product code MT 3 2 6 230 Type MT Multimode Relay MT Contact configuration 2 2 form C contacts (2 CO contacts), 8-pin 3 3 form C contacts (3 CO contacts), 11-pin Contact material 2 AgNi 90/10 3 AgNi 90/10, gold plated Version 1 DC with test button 3 DC with test button and bipolar LED 6 8 AC with test button AC with test button and LED Coil Coil code: please refer to coil versions table Other types on request Product code Contact Configuration Contact material Version Coil Part number MT221012 MT221024 MT221048 MT221060 MT221110 MT221220 MT223024 MT226012 MT226024 MT226048 MT226115 MT226230 MT228024 MT228115 MT228230 MT321012 MT321024 MT321048 MT321060 MT321110 MT321220 MT323024 MT3230C4 MT326012 MT326024 MT326048 MT326115 MT326230 MT328024 MT328115 MT328230 MT331024 MT331110 MT331220 MT333024 MT3330C4 MT333110 MT333220 MT336115 MT336230 MT338024 MT338115 MT338230 2 form C 2 CO contacts 8-pin AgNi 90/10 DC with test button 12VDC 24VDC 48VDC 60VDC 110VDC 220VDC 24VDC 12VAC 24VAC 48VAC 115VAC 230VAC 24VAC 115VAC 230VAC 12VDC 24VDC 48VDC 60VDC 110VDC 220VDC 24VDC 24VDC 12VAC 24VAC 48VAC 115VAC 230VAC 24VAC 115VAC 230VAC 24VDC 110VDC 220VDC 24VDC 24VDC 110VDC 220VDC 115VAC 230VAC 24VAC 115VAC 230VAC 4-1393090-9 5-1393090-0 5-1393090-1 5-1393090-2 5-1393090-3 5-1393090-4 5-1393090-7 6-1393090-3 6-1393090-4 6-1393090-5 6-1393090-7 6-1393090-8 6-1393090-9 7-1393090-0 7-1393090-1 6-1393091-8 7-1393091-0 7-1393091-1 7-1393091-2 7-1393091-4 7-1393091-7 8-1393091-4 7-1393091-9 9-1393091-6 9-1393091-7 9-1393091-8 1393092-1 1393092-2 1393092-4 1393092-7 1393092-8 1-1393092-1 1-1393092-3 1-1393092-5 1-1393092-8 1-1393092-6 2-1393092-0 2-1393092-2 2-1393092-5 2-1393092-6 2-1393092-7 8-1415025-1 2-1393092-8 05-2019, Rev. 0219 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. DC+LED+test button AC test button AC+LED test button 3 form C 3 CO contacts 11-pin AgNi 90/10 DC with test button DC+LED+test button DC+LED+PD+TB AC test button AC+LED test button AgNi 90/10 gold plated DC with test button DC+LED+test button DC+LED+PD+TB DC+LED test button AC test button AC+LED test button Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 3