50 RST 20i3 Mains, 3 pole General Application example The 3 pole connectors come in two variations. The standard version for general mains applications, and a green coding for applications in multi-phase systems. RST 20i3 Both connectors are mechanically coded. This means that only associated pairs of male and female can be connected with the correct polarity. You therefore have the security of a clear separation of different applications without having to redo any incorrect connections. The color of the connectors indicates the links that belong together. Coding Name Description Connectors 2 x cable entry Distribution units Distribution block 1 E/ 3 A RST compact distributor/ multi distributor 1 x cable entry Connection style Screw technology Spring clamp techn. Screw technology Spring clamp techn. Application Mains 250 V Mains 250/400 V Mechanical coding L, N, ground 1, 2, ground Strain relief housing Connection points per pole yes 1 yes 2 Cable assemblies black green available available available on request on request on request available available available on request on request on request Individual distribution box Connection cable Male - Free end Connection cable Female - Free end Extension cable Male - Female gray preassembled preassembled preassembled Connection cable Ground - Female Connection cable Contour European plug SK II - Female 51 Connectors Connector for cables of O 6 - 10 and 10 - 14 mm With spring clamp connections for rigid cables of 0.5 - 2.5 mm2, finestranded cables of 0.5 - 1.5 mm2 with ferrules, stranded cables of 0.75 - 1.5 mm2 with ferrules. Unassembled with cable gland1) and locking device. See "Technical Data" for sheath and insulation strip lengths as well as the ferrules to be used. Application Coding Cable diameter Color Part No. Std. Pack With screw connection2) for rigid, fine-stranded and stranded cables of 0.75 - 4.0 mm2. Unassembled with cable gland1) and locking device. See "Technical Data" for sheath and insulation strip lengths. Part No. Std. Pack Female connector 6 - 10 mm L, ground, N Mains 250 V 10 - 14 mm 13 - 18 mm 1, 2, ground Mains 250/400 V Application Coding 6 - 10 mm 10 - 14 mm 13 - 18 mm Cable diameter 96.031.0053.0 96.031.0053.1 96.031.0153.0 96.031.0153.1 96.031.4053.0 96.031.4053.1 96.031.4153.0 96.031.4153.1 green 96.031.0055.7 96.031.0155.7 96.031.4055.7 96.031.4155.7 Color Part No. Part No. gray black gray black gray black Std. Pack Std. Pack Male connector 6 - 10 mm Mains 250 V L, ground, N 10 - 14 mm 13 - 18 mm Mains 250/400 V 1, 2, ground 6 - 10 mm 10 - 14 mm 13 - 18 mm gray black gray black gray black green 96.032.0053.0 96.032.0053.1 96.032.0153.0 96.032.0153.1 96.032.4053.0 96.032.4053.1 96.032.4153.0 96.032.4153.1 96.032.0055.7 96.032.0155.7 96.032.4055.7 96.032.4155.7 1) 2) 52 Cable gland with bend protection available on request With wire protection available on request RST 20i3 With screw connection2) for rigid, fine-stranded and stranded cables of max. 4.0 mm2. Unassembled with cable gland and locking device. See "Technical Data" for sheath and insulation strip lengths. Part No. Std. Pack Mains, 3 pole Splitter connector With spring clamp connections for rigid cables of 0.5 - 2.5 mm2, finestranded cables of 0.5 - 1.5 mm2 with ferrules, stranded cables of 0.75 - 1.5 mm2 with ferrules. Unassembled with cable gland1) and locking device. See "Technical Data" for sheath and insulation strip lengths as well as the ferrules to be used. Part No. Std. Pack See "Accessories" for the mounting plate used to fasten the splitter connector. With screw connection2) for rigid, fine-stranded and stranded cables of 0.75 - 2.5 mm2. Unassembled with cable gland1) and locking device. See "Technical Data" for sheath and insulation strip lengths. Part No. Std. Pack See "Accessories" for the mounting plate used to fasten the splitter connector. 96.031.0253.0 96.031.0253.1 96.031.0353.0 96.031.0353.1 96.031.4253.0 96.031.4253.1 96.031.4353.0 96.031.4353.1 96.031.0255.7 96.031.0355.7 96.031.4255.7 96.031.4255.7 RST 20i3 Connector for cable O 13 - 18 mm 96.031.4553.0 96.031.4553.1 96.031.4555.7 Part No. Std. Pack 96.032.4553.0 96.032.4553.1 96.032.4555.7 53 Appliance connectors Appliance connector M25, standard With spring clamp connections for rigid cables of 0.5 - 2.5 mm2, finestranded cables of 0.5 - 1.5 mm2 with ferrules, stranded cables of 0.75 - 1.5 mm2 with ferrules. 2 connection points per pole. With locking device. Fixing in position guaranteed by flattening the thread. With M25x1.5 thread, external cable gland. Color Mains 250 V Part No. Std. Pack Part No. Std. Pack Appliance connector M20, modular, straight igid cables of 0.5 - 2.5 mm2, finestranded cables of 0.5 - 1.5 mm2 with ferrules, stranded cables of 0.75 - 1.5 mm2 with ferrules. 2 connection points per pole. With locking device. Fixing in position guaranteed by flattening the thread. With M20x1.5 thread, internal cable gland. With screw connections for rigid, fine-stranded and stranded cables of 0.75 - 4.0 mm2. 1 connection point per pole. With locking device. Fixing in position guaranteed by flattening the thread. With M20x1.5 thread, internal cable gland. Part No. Part No. Std. Pack Std. Pack See "Technical Data" for insulation strip lengths. See "Technical Data" for insulation See "Technical Data" for insulation strip lengths and the ferru- strip lengths. les to be used. gray 96.031.1053.0 black 96.031.1053.1 96.031.5053.0 96.031.5053.1 96.031.2053.0 96.031.2053.1 96.031.6053.0 96.031.6053.1 green 96.031.1055.7 96.031.5055.7 96.031.2055.7 96.031.6055.7 Part No. Part No. Female connector Application With screw connections for rigid, fine-stranded and stranded cables of 0.75 - 4.0 mm2. 1 connection point per pole. With lokking device. Fixing in position guaranteed by flattening the thread. With M25x1.5 thread, external cable gland. See "Technical Data" for insulation strip lengths and the ferrules to be used. L, N, ground Mains 250/400 V 1, 2, ground Color Part No. Std. Pack Std. Pack Std. Pack Part No. Std. Pack Male connector Application Mains 250 V gray 96.032.1053.0 black 96.032.1053.1 96.032.5053.0 96.032.5053.1 96.032.2053.0 96.032.2053.1 96.032.6053.0 96.032.6053.1 green 96.032.1055.7 96.032.5055.7 96.032.2055.7 96.032.6055.7 L, N, ground Mains 250/400 V 1, 2, ground 54 RST 20i3 Appliance connector M16, modular, straight With spring clamp connections for With screw connections for rigid, fine-stranded and stranded rigid cables of 0.5 - 2.5 mm2, finecables of 0.75 - 4.0 mm2. stranded cables of 0.5 - 1.5 mm2 1 connection point per pole. With with ferrules, stranded cables of locking device. Fixing in position 0.75 - 1.5 mm2 with ferrules. guaranteed by flattening the thread. 2 connection points per pole. With With M16x1.5 thread, internal cable locking device. Fixing in position guaranteed by flattening the thread. gland. With M16x1.5 thread, internal cable gland. Mains 250 V Part No. Std. Pack See "Technical Data" for insulation strip lengths and the ferrules to be used. Part No. Std. Pack See "Technical Data" for insulation strip lengths. With spring clamp connections for rigid cables of 0.5 - 2.5 mm2, finestranded cables of 0.5 - 1.5 mm2 with ferrules, stranded cables of 0.75 - 1.5 mm2 with ferrules. 2 connection points per pole. With locking device. Fixing in position guaranteed by flattening the thread. With M20x1.5 thread, internal cable gland. With screw connections for rigid, fine-stranded and stranded cables of 0.75 - 4.0 mm2. 1 connection point per pole. With locking device. Fixing in position guaranteed by flattening the thread. With M20x1.5 thread, internal cable gland. Part No. Part No. Std. Pack Std. Pack See "Technical Data" for insulation See "Technical Data" for insulation strip lengths and the ferru- strip lengths. les to be used. RST 20i3 Color Female connector Application Appliance connector M20, modular, angled gray 96.031.2153.0 black 96.031.2153.1 96.031.6153.0 96.031.6153.1 96.033.2053.0 96.033.2053.1 96.033.6053.0 96.033.6053.1 green 96.031.2155.7 96.031.6155.7 96.033.2055.7 96.033.6055.7 Part No. Part No. L, N, ground Mains 250/400 V 1, 2, ground Color Part No. Std. Pack Std. Pack Std. Pack Part No. Std. Pack Male connector Application Mains 250 V gray 96.032.2153.0 black 96.032.2153.1 96.032.6153.0 96.032.6153.1 96.034.2053.0 96.034.2053.1 96.034.6053.0 96.034.6053.1 green 96.032.2155.7 96.032.6155.7 96.034.2055.7 96.034.6055.7 L, N, ground Mains 250/400 V 1, 2, ground 55 Cable assemblies, 1.5 mm2 Extension cable Connection cable Connection cable Mains connection cable H05VV-F 3G1,5 H05VV-F 3G1,5 H05VV-F 3G1,5 H05VV-F 3G1,5 mm2 Female - Male Female - Free end Male - Free end Safety plug with locking device with ultrasonically welded wire ends with ultrasonically welded wire ends and locking device RST female connector Cable strip length: Insulation strip length: Cable strip length: Insulation strip length: 35 mm 9 mm 35 mm 9 mm Cable assemblies N = bl L = br ground = gn/yl Cable1) and shrinkage tube in black Length2) Part No. L, N, ground Female 1, 2, ground Female Std. Pack Part No. Std. Pack m m m m m m m m 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Gray insulation 96.232.1000.0 96.232.2000.0 96.232.3000.0 96.232.4000.0 96.232.5000.0 96.232.6000.0 96.232.7000.0 96.232.8000.0 96.232.1003.0 96.232.2003.0 96.232.3003.0 96.232.4003.0 96.232.5003.0 96.232.6003.0 96.232.7003.0 96.232.8003.0 96.232.1004.0 96.232.2004.0 96.232.3004.0 96.232.4004.0 96.232.5004.0 96.232.6004.0 96.232.7004.0 96.232.8004.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Green insulation 96.232.1001.7 96.232.2001.7 96.232.3001.7 96.232.4001.7 96.232.5001.7 96.232.6001.7 96.232.7001.7 96.232.8001.7 96.232.1005.7 96.232.2005.7 96.232.3005.7 96.232.4005.7 96.232.5005.7 96.232.6005.7 96.232.7005.7 96.232.8005.7 96.232.1006.7 96.232.2006.7 96.232.3006.7 96.232.4006.7 96.232.5006.7 96.232.6006.7 96.232.7006.7 96.232.8006.7 Male 1) 2) 56 Part No. 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Male Mains 250/400 V Std. Pack Black insulation 96.232.1000.1 96.232.2000.1 96.232.3000.1 96.232.4000.1 96.232.5000.1 96.232.6000.1 96.232.7000.1 96.232.8000.1 Mains 250 V Other cables available on request Other lengths available on request 96.232.1003.1 96.232.2003.1 96.232.3003.1 96.232.4003.1 96.232.5003.1 96.232.6003.1 96.232.7003.1 96.232.8003.1 96.232.1004.1 96.232.2004.1 96.232.3004.1 96.232.4004.1 96.232.5004.1 96.232.6004.1 96.232.7004.1 96.232.8004.1 All gray 99.706.0000.7 99.707.0000.7 1.5 m 2.5 m RST 20i3 Extension cable Connection cable Connection cable Mains, 3 pole Mains connection cable H07RN-F 3G1,5 H07RN-F 3G1,5 H07RN-F 3G1,5 H07RN-F 3G1,5 Female - Male Female - Free end Male - Free end Safety plug with locking device with ultrasonically welded wire ends with ultrasonically welded wire ends and locking device with splash guard RST female connector Cable strip length: Insulation strip length: Cable strip length: Insulation strip length: 35 mm 9 mm 35 mm 9 mm RST 20i3 Cable assemblies N = bl L = br ground = gn/yl Cable1) and shrinkage tube in black Length2) Part No. L, N, ground Female 1, 2, ground Female Part No. Std. Pack Part No. Std. Pack 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Gray insulation 96.232.1030.0 96.232.2030.0 96.232.3030.0 96.232.4030.0 96.232.5030.0 96.232.6030.0 96.232.7030.0 96.232.8030.0 96.232.1033.0 96.232.2033.0 96.232.3033.0 96.232.4033.0 96.232.5033.0 96.232.6033.0 96.232.7033.0 96.232.8033.0 96.232.1034.0 96.232.2034.0 96.232.3034.0 96.232.4034.0 96.232.5034.0 96.232.6034.0 96.232.7034.0 96.232.8034.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Green insulation 96.232.1031.7 96.232.2031.7 96.232.3031.7 96.232.4031.7 96.232.5031.7 96.232.6031.7 96.232.7031.7 96.232.8031.7 96.232.1035.7 96.232.2035.7 96.232.3035.7 96.232.4035.7 96.232.5035.7 96.232.6035.7 96.232.7035.7 96.232.8035.7 96.232.1036.7 96.232.2036.7 96.232.3036.7 96.232.4036.7 96.232.5036.7 96.232.6036.7 96.232.7036.7 96.232.8036.7 Male Mains 250/400 V Std. Pack Black insulation 96.232.1030.1 96.232.2030.1 96.232.3030.1 96.232.4030.1 96.232.5030.1 96.232.6030.1 96.232.7030.1 96.232.8030.1 Mains 250 V 96.232.1033.1 96.232.2033.1 96.232.3033.1 96.232.4033.1 96.232.5033.1 96.232.6033.1 96.232.7033.1 96.232.8033.1 96.232.1034.1 96.232.2034.1 96.232.3034.1 96.232.4034.1 96.232.5034.1 96.232.6034.1 96.232.7034.1 96.232.8034.1 All black 99.704.0000.7 99.705.0000.7 1.5 m 2.5 m Male 1) 2) Other cables available on request Other lengths available on request 57 Cable assemblies, 2.5 mm2 Extension cable Connection cable Connection cable H05VV-F 3G2,5 H05VV-F 3G2,5 H05VV-F 3G2,5 Female - Male Female - Free end Male - Free end with locking device with ultrasonically welded wire ends with ultrasonically welded wire ends and locking device Cable strip length: Insulation strip length: Cable strip length: Insulation strip length: 35 mm 9 mm Cable assemblies N = bl L = br ground = gn/yl Cable1) and shrinkage tube in black Length2) Part No. L, N, ground Female 1, 2, ground Female Std. Pack Part No. Std. Pack m m m m m m m m 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Gray insulation 96.233.1000.0 96.233.2000.0 96.233.3000.0 96.233.4000.0 96.233.5000.0 96.233.6000.0 96.233.7000.0 96.233.8000.0 96.233.1003.0 96.233.2003.0 96.233.3003.0 96.233.4003.0 96.233.5003.0 96.233.6003.0 96.233.7003.0 96.233.8003.0 96.233.1004.0 96.233.2004.0 96.233.3004.0 96.233.4004.0 96.233.5004.0 96.233.6004.0 96.233.7004.0 96.233.8004.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Green insulation 96.233.1001.7 96.233.2001.7 96.233.3001.7 96.233.4001.7 96.233.5001.7 96.233.6001.7 96.233.7001.7 96.233.8001.7 96.233.1005.7 96.233.2005.7 96.233.3005.7 96.233.4005.7 96.233.5005.7 96.233.6005.7 96.233.7005.7 96.233.8005.7 96.233.1006.7 96.233.2006.7 96.233.3006.7 96.233.4006.7 96.233.5006.7 96.233.6006.7 96.233.7006.7 96.233.8006.7 Male 1) 2) 58 Part No. 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Male Mains 250/400 V Std. Pack Black insulation 96.233.1000.1 96.233.2000.1 96.233.3000.1 96.233.4000.1 96.233.5000.1 96.233.6000.1 96.233.7000.1 96.233.8000.1 Mains 250 V Other cables available on request Other lengths available on request 96.233.1003.1 96.233.2003.1 96.233.3003.1 96.233.4003.1 96.233.5003.1 96.233.6003.1 96.233.7003.1 96.233.8003.1 96.233.1004.1 96.233.2004.1 96.233.3004.1 96.233.4004.1 96.233.5004.1 96.233.6004.1 96.233.7004.1 96.233.8004.1 35 mm 9 mm RST 20i3 Mains, 3 pole Extension cable Connection cable Connection cable H07RN-F 3G2,5 H07RN-F 3G2,5 H07RN-F 3G2,5 Female - Male Female - Free end Male - Free end with locking device with ultrasonically welded wire ends with ultrasonically welded wire ends and locking device Cable strip length: Insulation strip length: Cable strip length: Insulation strip length: 35 mm 9 mm 35 mm 9 mm RST 20i3 Cable assemblies N = bl L = br ground = gn/yl Cable1) and shrinkage tube in black Length2) Part No. L, N, ground Female 1, 2, ground Female Part No. Std. Pack Part No. Std. Pack 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Gray insulation 96.233.1030.0 96.233.2030.0 96.233.3030.0 96.233.4030.0 96.233.5030.0 96.233.6030.0 96.233.7030.0 96.233.8030.0 96.233.1033.0 96.233.2033.0 96.233.3033.0 96.233.4033.0 96.233.5033.0 96.233.6033.0 96.233.7033.0 96.233.8033.0 96.233.1034.0 96.233.2034.0 96.233.3034.0 96.233.4034.0 96.233.5034.0 96.233.6034.0 96.233.7034.0 96.233.8034.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 m m m m m m m m Green insulation 96.233.1031.7 96.233.2031.7 96.233.3031.7 96.233.4031.7 96.233.5031.7 96.233.6031.7 96.233.7031.7 96.233.8031.7 96.233.1035.7 96.233.2035.7 96.233.3035.7 96.233.4035.7 96.233.5035.7 96.233.6035.7 96.233.7035.7 96.233.8035.7 96.233.1036.7 96.233.2036.7 96.233.3036.7 96.233.4036.7 96.233.5036.7 96.233.6036.7 96.233.7036.7 96.233.8036.7 Male Mains 250/400 V Std. Pack Black insulation 96.233.1030.1 96.233.2030.1 96.233.3030.1 96.233.4030.1 96.233.5030.1 96.233.6030.1 96.233.7030.1 96.233.8030.1 Mains 250 V 96.233.1033.1 96.233.2033.1 96.233.3033.1 96.233.4033.1 96.233.5033.1 96.233.6033.1 96.233.7033.1 96.233.8033.1 96.233.1034.1 96.233.2034.1 96.233.3034.1 96.233.4034.1 96.233.5034.1 96.233.6034.1 96.233.7034.1 96.233.8034.1 Male 1) 2) Other cables available on request Other lengths available on request 59 Distribution units Color Mains 250 V L, N, ground Mains 250/400 V 1, 2, ground 60 Distribution block, 1E/3A Distribution block, 1E/3A with mounting option with locking levers 1 input, male connector, 3 pole 3 outputs, female connector, 3 pole without mounting option with locking levers 1 input, male connector, 3 pole 3 outputs, female connector, 3 pole Part No. Part No. Std. Pack Std. Pack gray black 96.030.0153.0 96.030.0153.1 96.030.0253.0 96.030.0253.1 green 96.030.0155.7 96.030.0255.7 RST 20i3 Mains, 3 pole RST compact distributor RST multi distributor Distribution box - Equip as needed with M25 appliance connectors 2 to 5 pole - 1 input; 3 outputs - pre-wired with 2.5 mm2 - with mounting option - Equip as needed with M25 appliance connectors 2 to 5 pole - 1 input; 7 outputs (max.) - Safety fuses 6.3 or 10 A can be integrated - pre-wired with 2.5 mm2 - with mounting option The individual distribution boxes offer optimum solutions for your specific application. The distributors are available in different dimensions and can accept DIN rail mounted devices and terminal blocks in any combination. Further connection to the consumer devices is carried out by the gesis IP+ connector system. Distribution blocks manufactured and tested according to specific customer requirements can be delivered to the construction site as pre-assembled components. The locking devices are already integrated. Std. Pack Part No. Std. Pack Part No. Std. Pack RST 20i3 Part No. Forecasted for the 4th quarter of 2006 Forecasted for the 4th quarter of 2006 Available on request 61