LBA110L DUAL POLE OptoMOS(R) Relay Load Voltage Load Current Max RON LBA110L 350 120 35 Description LBA110L is 350V, 120mA, 35 independent 1-Form-A and 1-Form-B relays. It is designed to provide an ideal solution where a complimentary Form-A/Form-B relay pair is required. Current limiting version is available ("L" suffix). Units V mA Features * Small 8 Pin DIP Package * Low Drive Power Requirements (TTL/CMOS Compatible) * No Moving Parts * High Reliability * Arc-Free With No Snubbing Circuits * 3750VRMS Input/Output Isolation * FCC Compatible * VDE Compatible * No EMI/RFI Generation * Machine Insertable, Wave Solderable * Current Limiting Surface Mount and Tape & Reel Versions Available Applications * Telecommunications * Telecom Switching * Tip/Ring Circuits * Modem Switching (Laptop, Notebook, Pocket Size) * Hookswitch * Dial Pulsing * Ground Start * Ringer Injection * Instrumentation * Multiplexers * Data Acquisition * Electronic Switching * I/O Subsystems * Meters (Watt-Hour, Water, Gas) * Medical Equipment-Patient/Equipment Isolation * Security * Aerospace * Industrial Controls Approvals * UL Recognized: File Number E76270 * CSA Certified: File Number LR 43639-10 * BSI Certified to: * BS EN 60950:1992 (BS7002:1992) Certificate #: 7344 * BS EN 41003:1993 Certificate #: 7344 Ordering Information Part # LBA110L LBA110PL LBA110PLTR LBA110LS LBA110LSTR Description 8 Pin DIP (50/Tube) 8 Pin Flatpack (50/Tube) 8 Pin Flatpack (1000/Reel) 8 Pin Surface Mount (50/Tube) 8 Pin Surface Mount (1000/Reel) Pin Configuration LBA110L Pinout AC/DC Configuration + Control - Normally Closed - Control - Normally Closed + Control - Normally Open - Control - Normally Open 1 8 2 7 3 6 4 5 Switching Characteristics of Normally Open (Form A) Devices Normally Closed Pole Normally Open Pole Switching Characteristics of Normally Closed (Form B) Devices 10ms 10ms CONTROL CONTROL +90% + 90% LOAD 10%+ 10%+ TON DS-LBA110L-R3 www.clare.com TOFF + 90% +10% TOFF TON 1 LBA110L Absolute Maximum Ratings (@ 25 C) Parameter Min Input Power Dissipation - - 1501 Input Control Current Peak (10ms) - - 50 1 mW mA A Reverse Input Voltage - - 5 V Total Power Dissipation - - 8002 mW 3750 - - VRMS Operational Temperature -40 - +85 C Storage Temperature -40 - +125 C - - +260 C - - +220 C Isolation Voltage Input to Output Soldering Temperature DIP Package Flatpack/Surface Mount Package (10 Seconds Max.) 1 Derate Linearly 1.33 mw/C 2 Derate Linearly 6.67 mw/C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability. Typ Max Units Electrical Characteristics Parameter Conditions Symbol Min Typ Max Units - VL - - 350 V - IL - - 120 mA 10ms ILPK - - - mA Output Characteristics @ 25C Load Voltage (Peak) Load Current *(Continuous) AC/DC Configuration Peak Load Current On-Resistance AC/DC Configuration IL=120mA RON - 23 35 Off-State Leakage Current VL=350V ILEAK - - 1 A Switching Speeds Turn-On Turn-Off IF=5mA, VL=10V IF=5mA, VL=10V TON TOFF - - 3 3 ms ms Output Capacitance 50V; f=1MHz COUT - 25 - pF Load Current Limiting Form A only ICL 130 170 210 mA IL=Load Current IF 5 - 50 mA Input Characteristics @ 25C Input Control Current - IF 0.4 0.7 - mA IF=5mA VF 0.9 1.2 1.4 V Reverse Input Voltage - VR - - 5 V Reverse Input Current VR=5V IR - - 10 A Input Dropout Current Input Voltage Drop Input to Output Capacitance - CI/O - 3 - pF Input to Output Isolation - VI/O 3750 - - VRMS *NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value. 2 www.clare.com Rev. 3 LBA110L PERFORMANCE DATA* 35 30 30 25 20 15 10 20 15 10 5 0 0 1.19 1.21 1.23 1.25 10 16.1 16.4 16.7 17.0 17.3 17.6 27.8 25 25 20 20 15 10 Device Count (N) 30 25 20 15 10 5 5 0 0 376.8 378.3 379.8 381.3 382.8 384.3 385.8 5 0.5 LBA110L - FormA Typical IF for Switch Dropout (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 20 20 Device Count (N) 25 Device Count (N) 25 5 15 10 5 0 0 1.5 1.9 0.45 LED Current (mA) 5 0.75 1.05 1.35 1.65 1.95 0.35 Device Count (N) 20 Device Count (N) 25 25 20 15 10 5 0.15 0.25 0.35 0.45 Turn-On (ms) 0.55 0.65 0.55 0.65 0.75 0.85 0.95 LBA110L - FormA Typical Turn-Off Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) LBA110L - FormB Typical Turn-On Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) 30 0 0.45 LED Current (mA) 20 5 1.5 10 25 10 1.3 15 LED Current (mA) 15 1.1 0 0.15 LBA110L - FormA Typical Turn-On Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) 0.9 LBA110L - FormB Typical IF for Switch Dropout (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 25 1.3 0.7 LED Current (mA) 30 10 32.0 10 Blocking Voltage (V) 15 31.3 0 Blocking Voltage (V) 20 30.6 15 386.3 388.8 391.3 393.8 396.3 398.8 401.3 LBA110L - FormB Typical IF for Switch Operation (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 29.9 LBA110L - FormA Typical IF for Switch Operation (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) LBA110L - FormB Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25C) 30 1.1 29.2 On-Resistance () 35 0.7 28.5 On-Resistance () Device Count (N) Device Count (N) 15 0 15.8 LBA110L - FormA Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25C) Device Count (N) 20 5 LED Forward Voltage Drop (V) Device Count (N) 30 LBA110L - FormB Typical On-Resistance Distribution (N=50 Ambient Temperature = 25C) (Load Current = 120mADC, IF=5mADC) 25 25 5 1.17 LBA110L - FormA Typical On-Resistance Distribution (N=50 Ambient Temperature = 25C) (Load Current = 120mADC, IF=5mADC) Device Count (N) 35 Device Count (N) Device Count (N) LBA110L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25C; IF = 5mADC) 15 10 5 0 0 0.10 0.14 0.18 0.22 0.26 0.30 Turn-On (ms) 0.03 0.08 0.13 0.18 0.23 Turn-Off (ms) The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. Rev. 3 www.clare.com 3 LBA110 PERFORMANCE DATA* LBA110L - FormB Typical Turn-Off Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) LBA110L - Form A Typical Load Current vs. Temperature Load Current (mA) 20 15 10 5 180 160 160 140 140 120 100 20mA 10mA 5mA 80 60 40 20 0.25 0.35 0.45 0.55 0.65 -20 0 20 LBA110L Typical Leakage vs. Temperature (Measured across Pins 5 & 6 or 7 & 8) 80 100 0.015 0.010 -20 0 20 40 60 80 390 385 380 375 370 365 -40 360 -40 -20 0 20 40 60 80 100 0.30 20mA 0.25 0.25 0.20 0.15 0.10 0.20 0.05 0.15 0 60 80 Turn-Off (ms) 10mA 5mA -40 100 -20 0 5mA 10mA 0.4 20mA 0.3 0.2 0.1 -40 -20 0 20 40 60 Temperature (C) 80 100 LED Forward Voltage Drop (V) 0.7 0.5 20 40 60 80 0.35 1.4 50mA 30mA 20mA 10mA 5mA 1.2 1.0 -20 0 40 60 20 40 60 80 100 -20 0 20 40 60 80 100 80 Temperature (C) 100 0.30 0.25 0.20 0.15 0.8 20 120 LBA110L - FormA Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) 0.40 0 100 Temperature (C) 1.6 -20 80 5mA -40 1.8 -40 60 0.20 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 100 LBA110L Typical LED Forward Voltage Drop vs. Temperature LBA110L - FormB Typical Turn-Off vs. Temperature (Load Current = 120mADC) 0.6 -40 Temperature (C) Temperature (C) 40 LBA110L - FormA Typical Turn-Off vs. Temperature (Load Current = 120mADC) 0.30 Turn-On (ms) 0.40 40 20 Temperature (C) 0.35 0.35 410 405 400 395 390 385 380 375 370 365 360 LBA110L - FormB Typical Turn-On vs. Temperature (Load Current = 120mADC) 5mA 0.45 20 0 Temperature (C) 0.50 0 -20 LBA110L - FormB Typical Blocking Voltage vs. Temperature 355 100 LBA110L - FormA Typical Turn-On vs. Temperature (Load Current = 120mADC) -20 40 Temperature (C) 395 Temperature (C) -40 60 120 Blocking Voltage (VRMS) Blocking Voltage (VRMS) Leakage (A) 0.020 0.005 Turn-On (ms) 60 400 0.025 Turn-Off (ms) 40 LBA110L - FormA Typical Blocking Voltage vs. Temperature 0.030 -40 5mA 80 Temperature (C) Turn-Off (ms) 0 100 0 -40 0.75 120 20 0 0 Turn-On (ms) Device Count (N) 25 LBA110L - Form B Typical Load Current vs. Temperature 180 Load Current (mA) 30 120 0.10 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com Rev. 3 LBA110L PERFORMANCE DATA* LBA110L - FormB Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) LBA110L - FormA Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) 0.092 0.7 0.090 0.6 0.088 0.15 0.10 0.5 Turn-Off (ms) 0.20 Turn-Off (ms) Turn-On (ms) 0.25 LBA110L - FormB Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) 0.086 0.084 0.082 0.080 0.4 0.3 0.2 0.078 0.1 0.076 0.05 0.074 0 5 10 15 20 25 30 35 40 45 50 0 0 5 LED Forward Current (mA) 25 30 35 40 45 50 0 2.500 50 2.000 16 14 12 LED Current (mA) 60 40 30 20 0 20 40 60 80 25 30 35 40 45 50 0.500 0 -40 100 20 1.000 0 8 15 1.500 10 -20 10 LBA110L - FormA Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) 18 -40 5 LED Forward Current (mA) 20 On-Resistance () On-Resistance () 20 LBA110L - FormB Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) 10 -20 0 20 40 60 80 -40 100 -20 0 20 40 60 80 100 Temperature (C) Temperature (C) Temperature (C) LBA110L - FormB Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) LBA110L - FormA Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) LBA110L - FormB Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) 3.000 3.0 2.500 2.000 1.500 1.000 1.500 1.000 0.500 0.500 0 0 -40 -20 0 20 40 60 80 2.5 2.000 LED Current (mA) LED Current (mA) 2.500 100 -20 0 40 60 80 50 0 -50 -100 50 0 -50 -100 -150 -1.5 -1.0 -0.5 0 0.5 1.0 1.5 2.0 Load Voltage (V) -4 -3 -2 -1 0 1 -20 0 20 40 60 80 100 Temperature (C) LBA110L Energy Rating Curve Load Current (A) 100 Load Current (mA) 100 1.0 -40 100 LBA110L - FormB Typical Load Current vs. Load Voltage (Ambient Temperature = 25C; IF = 5mADC) 150 -150 -2.0 20 Temperature (C) 150 1.5 0 -40 LBA110L - FormA Typical Load Current vs. Load Voltage (Ambient Temperature = 25C; IF = 5mADC) 2.0 0.5 Temperature (C) Load Current (mA) 15 LED Forward Current (mA) LBA110L - FormA Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) LED Current (mA) 10 2 Load Voltage (V) 3 4 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10s 100s 1ms 10ms 100ms 1s 10s 100s Time LBA110L Typical Current Limiting Characteristics vs. Temperature IF = 5mA Current Limit (mA) 250 200 150 100 50 0 -40 -20 0 20 40 60 80 100 Temperature (C) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. Rev. 3 www.clare.com 5 LBA110L Mechanical Dimensions 2.540 .127 8-.800 DIA. (.100 .005) (8-.031 DIA.) 2.540 .127 (.100 .005) 7.620 .254 (.300 .010) 7.239 TYP. (.285) PC Board Pattern (Top View) 9.652 .381 (.380 .015) 8 Pin DIP Through Hole (Standard) 3.302 (.130) 9.144 .508 (.360 .020) 6.350 .127 (.250 .005) 9.144 TYP. (.360) 7.620 .127 (.300 .005) 6.350 .127 (.250 .005) .457 .076 (.018 .003) 7.620 .127 (.300 .005) 8.077 .127 (.318 .005 ) 9.652 .381 (.380 .015) 2.540 .127 (.100 .005) 8 Pin Flatpack ("P" Suffix) 2.159 TYP. (.085) PC Board Pattern (Top View) 2.540 .127 (.100 .005) 7.620 .254 (.300 .010) 6.350 .127 (.250 .005) 2.286 MAX. .635 .127 (.090) (.025) 9.398 .127 (.370 .005) .203 (.008) 1.193 (.047) .457 .076 (.018 .003) 8.077 .127 (.318 .005) 3.302 (.130) .635 TYP. (.025) PC Board Pattern (Top View) 2.540 .127 2.540 .127 (.100 .005) 7.620 .254 (.300 .010) 4.445 .127 (.175 .005) .787 (.031) 9.652 .381 (.380 .015) 8 Pin DIP Surface Mount ("S" Suffix) (.100 .005) 9.525 .254 (.375 .010) 6.350 .127 (.250 .005) .254 TYP. (.010) 8.763 .127 (.345 .005) 8.305 .127 (.327 .005) 1.905 .127 (.075 .005) .457 .076 (.018 .003) 8.077 .127 (.318 .005) 1.498 .127 (.059 .005) Dimensions mm (inches) 6 www.clare.com Rev. 3 LBA110L Mechanical Dimensions Tape and Reel Packaging for 8 Pin Surface Mount Package 330.2 DIA. (13.00) 6.731 MAX. 1.753 .102 (.265) (.069 .004) .406 MAX. (.016) Top Cover Tape Thickness .102 MAX. (.004) 2.007 .102 1.498 .102 3.987 .102 (.079 .004) (.059 .004) (.157 .004) 7.493 .102 (.295 .004) 1 16.002 .305 (.630 .012) 8 12.090 (.476) 10.300 (.405) 4.877 (.192) Top Cover Tape Embossed Carrier .050R TYP. 11.989 .102 (.472 .004) 10.300 .102 (.405 .004) 1.549 .102 (.061 .004) User Direction of Feed Embossment Tape and Reel Packaging for 8 Pin Flatpack Package 330.2 DIA. (13.00) Top Cover Tape Thickness .102 MAX. (.004) 6.731 MAX. 1.753 0.102 (.265) (.069 .004) .406 MAX. (.016) 2.007 .102 1.498 .102 3.987 .102 (.079 .004) (.059 .004) (.157 .004) 7.493 .102 (.295 .004) 1 8 12.090 (.476) 10.287 (.405) 4.877 (.192) Top Cover Tape Embossed Carrier 16.002 .305 (.630 .012) .050R TYP. 11.988 .102 (.472 .004) Embossment 10.287 .102 (.405 .004) 1.549 .102 (.061 .004) User Direction of Feed Dimensions mm (inches) Rev. 3 www.clare.com 7 For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare's Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare's product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LBA110L-R3.0 (c)Copyright 2002, Clare, Inc. All rights reserved. Printed in USA. 6/25/02