PB-360 360W Single Output Battery Charger series Features : Charger for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese) (Note.1) 3 stage charging AC 115/230VAC selected by switch Built-in passive PFC function compliance to EN61000-3-2 Class A (option) Protection: Short circuit / Reverse polarity / Over voltage / Over temperature 2 color LED loading indicator Low cost, High reliability FAN on/off control(Depends on charging current) 3 years warranty (except for 48V) PB 360 P (P type only) 12 12:14.4V 24:28.8V 48:57.6V P:With Passive PFC N:Without Passive PFC SPECIFICATION PB-360-24 PB-360-48 BOOST CHARGE VOLTAGE Vboost 14.4V PB-360-12 28.8V 57.6V FLOAT CHARGE VOLTAGE Vfloat 13.6V 27.2V 54.4V VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V 26 ~ 28.8V 52 ~ 58.6V 40 ~ 125Ah 20 ~ 65Ah MODEL OUTPUT RECOMMENDED BATTERY CAPACITY(AMP HOURS) Note 6 BATTERY TYPE 80 ~ 240Ah Open & Sealed Lead Acid OUTPUT CURRENT (Typ.) Note 7 24.3A INPUT PROTECTION 90 ~ 132VAC / 180 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115VAC 3.5A/230VAC COLD START 60A 86% 87% LEAKAGE CURRENT <3.5mA / 240VAC O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on REVERSE POLARITY By internal fuse OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 5) EMC EMISSION 16 ~ 18V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work 59 ~ 64V Short: Stop Charging -20 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing 0.05%/ (0 ~ 45) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 (only P type) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A MTBF DIMENSION 115.8Khrs min. PACKING NOTE 6.25A 127 ~ 187VDC / 254 ~ 370VDC SHORT CIRCUIT OVER TEMPERATURE FUNCTION REMOTE CONTROL (CN5) OTHERS 12.5A VOLTAGE RANGE MIL-HDBK-217F (25) 253*135*48.5mm(L*W*H) 1.5Kg; 6pcs/10Kg/0.95CUFT 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 7. Maximum charging current will be in the range of 90~110% rated output current. File Name:PB-360-SPEC 2017-07-14 PB-360 360W Single Output Battery Charger Mechanical Specification Case No.801A series Unit:mm 253 235 12 54 127 48.5 11 -V ON/OFF SWITCH +V 230 12 LED INLET 9.25 9 .7 5 5.5 CN5 135 SVR1 Air flow direction Remote Control( CN5 ) : JST B2B-XH or equivalent Assignment PIN1,2 Open: Normal work PIN1,2 Short: Stop Charging Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent Block Diagram fosc : 70KHz FAN ON/OFF CONTROL RECTIFIERS & PASSIVE P.F.C. EMI FILTER I/P POWER SWITCHING POLARITY REVERSE PROTECTION RECTIFIERS & FILTER +V -V O.C.P. FG O.L.P. DETECTION CIRCUIT PWM CONTROL O.V.P. Output Load VS Temperature Charging Curve Start V boost 100 V float Charge Voltage 90 80 100% Charge Current Constant Current Constant Voltage stage 1 Color of LED Loading Indicator stage 2 stage 3 Red LOAD (%) 70 10% 60 40 30 Green -20 State Constant Current V boost V float PB-360-12 24.3A 14.4V 13.6V PB-360-24 12.5A 28.8V 27.2V PB-360-48 6.25A 57.6V 54.4V 10 20 30 40 50 60 70 AMBIENT TEMPERATURE () File Name:PB-360-SPEC 2017-07-14