12
Notes:
1. Derate linearly above 70°C free-air temperature at a rate of 0.8 mA/°C (8-Pin DIP).
Derate linearly above 85°C free-air temperature at a rate of 0.5 mA/°C (SO-8).
2. Derate linearly above 70°C free-air temperature at a rate of 1.6 mA/°C (8-Pin DIP).
Derate linearly above 85°C free-air temperature at a rate of 1.0 mA/°C (SO-8).
3. Derate linearly above 70°C free-air temperature at a rate of 0.9 mW/°C (8-Pin DIP).
Derate linearly above 85°C free-air temperature at a rate of 1.1 mW/°C (SO-8).
4. Derate linearly above 70°C free-air temperature at a rate of 2.0 mW/°C (8-Pin DIP).
Derate linearly above 85°C free-air temperature at a rate of 2.3 mW/°C (SO-8).
5. CURRENT TRANSFER RATIO in percent is dened as the ratio of output collector current, IO, to the forward LED input current, IF, times 100.
6. Device considered a two-terminal device: Pins 1, 2, 3, and 4 shorted together and Pins 5, 6, 7, and 8 shorted together.
7. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dVCM/dt on the leading edge of the common mode
pulse signal, V
CM, to assure that the output will remain in a Logic High state (i.e., VO > 2.0 V). Common mode transient immunity in a Logic Low
level is the maximum tolerable (negative) dVCM/dt on the trailing edge of the common mode pulse signal, VCM, to assure that the output will
remain in a Logic Low state (i.e., VO < 0.8 V).
8. The 1.9 kΩ load represents 1 TTL unit load of 1.6 mA and the 5.6 kΩ pull-up resistor.
9. The 4.1 kΩ load represents 1 LSTTL unit load of 0.36 mA and 6.1 kΩ pull-up resistor.
10. The frequency at which the ac output voltage is 3 dB below its mid-frequency value.
11. The JEDEC registration for the 6N136 species a minimum CTR of 15%. Avago guarantees a minimum CTR of 19%.
12. See Option 020 data sheet for more information.
13. Use of a 0.1 µf bypass capacitor connected between pins 5 and 8 is recommended.
14. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 V rms for 1 second (leakage detec-
tion current limit, II-O ≤ 5 µA). This test is performed before the 100% Production test shown in the IEC/EN/DIN EN 60747-5-5 Insulation Related
Characteristics Table if applicable.
15. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (leakage detec-
tion current limit, II-O ≤ 5 µA). This test is performed before the 100% Production test shown in the IEC/EN/DIN EN 60747-5-5 Insulation Related
Characteristics Table if applicable.
16. This rating is equally validated by an equivalent ac proof test.
Package Characteristics
Over recommended temperature (TA = 0°C to 70°C) unless otherwise specied.
Parameter Sym. Device Min. Typ.* Max. Units Test Conditions Fig. Note
Input-Output
Momentary
Withstand
Voltage**
VISO 8-Pin DIP SO-8 3750 V rms RH < 50%,
t = 1 min.,
TA = 25°C
6, 14
Widebody 5000 6, 15
8-Pin DIP (Option 020) 5000 6, 12, 15
II-O 8-Pin DIP 1 µA 45% RH, t = 5 s,
VI-O = 3 kVdc,
TA = 25°C
6, 16
Input-Output
Resistance
RI-O 8-Pin DIP SO-8 1012 Ω VI-O = 500 Vdc 6
Widebody 1012 1013 TA = 25°C
1011 TA = 100°C
Input-Output
Capacitance
CI-O 8-Pin DIP SO-8 0.6 pF f = 1 MHz 6
Widebody 0.5 0.6
* All typicals at TA = 25°C.
** The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics Table (if applicable), your
equipment level safety specication or Avago Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage,” publication number
5963-2203E.