1590A Paired - Category 5e Unbonded-Pair Cable For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents : No. 8 for DataTwist Cables (Modified Western Electric).pdf Description: 24 AWG solid bare copper conductors, plenum, FEP Teflon(R) insulation, twisted pairs, rip cord, see color code chart (below), Flamarrest(R) jacket (natural or blue). SUITABLE APPLICATIONS: Suitable Applications Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Pairs 2 Total Number of Conductors 4 AWG 24 Stranding Solid Conductor Material BC - Bare Copper INSULATION: Insulation Material FEP - Fluorinated Ethylene Propylene Pair Color Code Chart : Number 1 Color White/Blue Stripe & Blue Number 2 OUTER SHIELD: Outer Shield Material Unshielded OUTER JACKET: Outer Jacket Material Trade Name Flamarrest(R) Outer Jacket Material LS PVC - Low Smoke Polyvinyl Chloride Outer Jacket Ripcord Yes OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .165 in. Page 1 of 4 Color White/Orange Stripe & Orange 1590A Paired - Category 5e Unbonded-Pair Cable MECHANICAL CHARACTERISTICS: Operating Temperature Range -20C To +75C Bulk Cable Weight 21 lbs/1000 ft. Max. Recommended Pulling Tension 13 lbs. Min. Bend Radius (Install) 0.7 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification CMP, UL444 CEC/C(UL) Specification CMP EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005 TIA/EIA Specification 568-B.2 Category 5e Other Specification NEMA WC-63.1 Category 5e, UL verified to Category 5e FLAME TEST: UL Flame Test NFPA 262 CSA Flame Test FT4, FT6 PLENUM/NON-PLENUM: Plenum (Y/N) Y Non-Plenum Number 1588A, 1588R ELECTRICAL CHARACTERISTICS: Nom. Mutual Capacitance @ 1 KHz 14 pF/ft Maximum Capacitance Unbalance (pF/100 m) 330 pF/100 m Nominal Velocity of Propagation 72 % Maximum Delay (ns/100 m) 538 @ 100MHz ns/100 m Maximum Delay Skew (ns/100m) 45 ns/100 m Maximum Conductor DC Resistance @ 20 Deg. C 9.38 Ohms/100 m Maximum DCR Unbalance @ 20 Deg. C 5% Max. Operating Voltage - UL 300 V RMS ELECTRICAL CHARACTERISTICS - PREMISE: Premise Cable Electricals Table 1 : Page 2 of 4 1590A Paired - Category 5e Unbonded-Pair Cable Frequency (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT Min. ACR (dB) Min. PSACR (dB) (dB) Min. Return Loss (dB) 1 4 8 10 16 20 25 31.25 62.5 100 155 200 2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0 28.1 32.0 65.3 56.3 51.8 50.3 47.3 45.8 44.3 42.9 38.4 35.3 32.5 30.8 62.3 53.3 48.8 47.3 44.3 42.8 41.3 39.9 35.4 32.3 29.5 27.8 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 15.8 15.0 63.0 51.0 46.0 43.0 39.0 36.5 33.9 31.0 22.0 14.0 4.4 4.0 60.3 49.2 43.0 40.8 36.0 33.5 30.9 28.2 19.0 10.3 1.4 1.0 Min. Structural Return Loss (dB) 23.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 Premise Cable Electricals Table 2 : Frequency (MHz) 1 4 8 10 16 20 25 31.25 62.5 100 155 200 Input (Unfitted) Impedance (Ohms) 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 25 100 25 Fitted Impedance (Ohms) 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 100 15 Min. ELFEXT (dB) Min. PSELFEXT (dB) 63.8 51.7 45.7 43.8 39.7 37.7 35.8 33.9 27.8 23.8 19.9 17.7 60.8 48.7 42.7 40.8 36.7 34.7 32.8 30.9 24.9 20.8 16.9 14.7 NOTES: Notes Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568B.2, Category 5e. PUT-UPS AND COLORS: Item Description 1590A 8771000 2 PR #24 FEP FLMRST 1590A D151000 2 PR #24 FEP FLMRST Put-Up (ft.) 1000 Ship Weight (lbs.) 16 Jacket Color NATURAL 1000 16 BLUE C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 04-18-2006 Page 3 of 4 Notes C 1590A Paired - Category 5e Unbonded-Pair Cable (c) Copyright 2006 Belden, Inc All Rights Reserved. Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4