INNOLINE
DC/DC-Converter
with 3 year Warranty
R-78B-1.0
1.0 AMP
SIP3
Single Output
●Efficiency up to 97%,Non isolated,
no need for heatsinks
●Pin-out compatible with LM78XX Linears
●Low profile( L*W*H=11.5*8.5*17.5mm)
●Wide input range.(4.75V ~ 34V)
●Short circuit protection, Thermal shutdown
●Low ripple and noise
●“L” version with 90° pins
●See Innoline Application Notes for use as an
inverter (alternative to LM79xx Linear)
Features
Selection Guide
Part Input Output Output Efficiency
Number Range Voltage Current Min. Vin Max. Vin
SIP3 (V) (V) (A) (%) (%)
R-78B1.5-1.0 4.75 – 26 1.5 1.0 77 71
R-78B1.8-1.0 4.75 – 26 1.8 1.0 80 74
R-78B2.5-1.0 4.75 – 32 2.5 1.0 85 78
R-78B3.3-1.0 4.75 – 32 3.3 1.0 89 83
R-78B5.0-1.0 6.5 – 32 5.0 1.0 93 88
R-78B6.5-1.0 9.0 – 32 6.5 1.0 94 90
R-78B9.0-1.0 12 – 32 9.0 1.0 95 93
R-78B12-1.0 16 – 32 12 1.0 96 95
R-78B15-1.0 20 – 32 15 1.0 97 96
Derating-Graph
(Ambient Temperature)
The R-78Bxx-1.0 Series high efficiency switching regulators are ideally suited to replace 78xx linear regulators and are
pin compatible. The efficiency of up to 97% means that very little energy is wasted as heat so there is no need for any
heat sinks with their additional space and mounting costs.
The L-Version with 90° pins allows direct replacement for laid-flat regulators where component height is at a premium.
Low ripple and noise figures and a short circuit input current of typically only 10mA round off the specifications of this
versatile converter series.
Description
* add Suffix “L” for 90° bent pins, e.g. R-78B5.0-1.0L
EN-55022 Certified
EN-55024 Certified
EN-60601-1-2 Certified
IEC/EN-60950-1 Certified
RoHS
2011/65/EU
6/6
Refer to Application Notes
Characteristics Conditions Min. Typ. Max.
Input Voltage Range 1.5V, 1.8V 4.75V 25 26V abs. max.
2.5V to 15.5V 4.75V 32 34V abs. max.
Output Voltage Range (for customized parts) All Series 1.5V 15.5V
Output Current (see Note 1) All Series 0mA* 1000mA
Short Circuit Input Current (Vin = 24V) All Series 60mA
Internal Power Dissipation 0.65W
Short Circuit Protection Continuous, automatic recovery
Output Voltage Accuracy (At 100% Load) All Series ±2% ±3%
Line Voltage Regulation (Vin = min. to max. at full load) 1.5V to 6.5V 0.2% 0.4%
9V to 15.5V 0.1% 0.2%
Load Regulation (10% to 100% full load) 1.5V to 6.5V 0.4% 0.6%
9V to 15.5V 0.25% 0.4%
Dynamic Load Stability (with Output Capacitor=100µF) 100% <-> 50% load ±100mV ±150mV
Transient Recovery Time 1.0ms 1.5ms
Ripple & Noise (without Output Capacitor) 1.5V to 6.5V 15mVp-p 20mVp-p
(10% to 100% full load) 9V to 15.5V 25mVp-p 35mVp-p
Temperature Coefficient -40°C ~ +85°C ambient 0.015%/°C
continued on next page
Specifications (refer to the standard application circuit, Ta: 25°C, minimum load = 10%)
www.recom-power.com I-21REV: 0/2015