TYPE PRODUCT SPECIFICATION NUMBER GS-12-279
TITLE PAGE REVISION
Straddle mount type Power edge connector 4 of 11 F
AUTHORIZED BY DATE
Hai-Ling Liu April 10,2015
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C GS-01-029
7.2 Normal Force - The contact normal force shall not be less than 150 grams per contact when tested in
accordance with FCI Test Specification BUS-03-404.
7.3 Contact Retention - Individual power contacts shall withstand an axial retention load of 300 gf minimum
per pin to seat further into housing.
a. Rate of 25.4 mm/minute without dislodging from the housing cavity.
b. Test PCB thickness is 1.57+/-0.13mm (inclusive of two pads).
c. Test pin numbers: 1, 10, 19, 20, 29, 38
7.4 Solder tails Insertion- the insertion force of Straddle type solder and mounting PCB shall not exceed 10
Kgf per all solder tails to insert into mounting PCB.
The following details shall apply:
a. Rate of 25.4mm/minute with Mounting PCB.
b. Test PCB thickness is 1.57+/-0.13mm (inclusive of two pads).
7.5 Reseating
The connector pair needs to undergo 3 manual plug/unplug cycles.
a. Sample Size – Dependent upon current test group, refer to specific sample sizes.
b. Failure Criteria - No evidence of physical damage.
c. No lubrication to be used during cycling.
7.6 Vibration Sinusoidal - EIA 364 TP 28
a. Test procedure: Test Condition – VII, test condition letter D.
b. Mounting – To eliminate relative motion between the contacts, both mating halves should be
rigidly fixed.
c. Duration – 1 hour per axis / 3 axis.
d. Failure criteria - No evidence of physical damage. No interruptions > 1.0 micro-second.
7.7 Mechanical Shock - EIA 364-27
a. Condition A (50G, 11 millisecond half sine wave )
b. Shocks - 3 shocks in both directions along each of three orthogonal axes (18 total)
c. Mounting - rigidly mount assemblies
d. No discontinuities of greater than 1.0 micro-second
7.8 Durability - Standard laboratory procedure as applicable to the specific product EIA-364-09
a. Number of Cycles - 200
b. Cycling rate – 25.4mm per minute
7.9 Durability (preconditioning) EIA-364-09
The intent of this test is encompassed in latest version of EIA-364-09.
a. Number of Cycles - 5
b. Sample Size – Dependent upon current test group, refer to specific sample sizes.
c. Failure Criteria – No evidence of physical damage.
PDS: Rev :F STATUS:Released Printed: May 14, 2015