Specifications are subject to change without notice (25.06.99) 1
Level Sensors
1 to 4 electrodes
Isolated or unisolated electrodes
Cable or screw connection
1/2”, 1” or 1 1/2” without pipe thread according to
ISO 228/1-Gxxx”
Product Description Ordering Key
Level sensor for measuring
the level of conductive li-
quids, i.e. max./min. control
of charging or discharging.
The function is determined by
the amplifier relay used. The
sensors are delivered with
standard length electrodes -
these are cut off to suit the
application.
Type
Housing material
Number of electrodes
Thread
Specifications
Pipe thread Electrode Housing Ordering no. Ordering no. Ordering no. Ordering no.
isolation Material 1 electrode 2 electrodes 3 electrodes 4 electrodes
1 1/2” No Nylon 6 VN 1 VN 2 VN 3 VN 4
1 1/2” No Nylon 6 VNY 1 VNY 2 VNY 3 VNY 4
1 1/2” Polyethylene Nylon 6 VNI 1 VNI 2 VNI 3 VNI 4
1 1/2” Polyethylene Nylon 6 VNYI 1 VNYI 2 VNYI 3 VNYI 4
1/2” Polyethylene PVC VPC 105 VPC 205
1” Polyethylene PVC VPC 110 VPC 210 VPC 310
1/2” Polypropylene Kynar (PVDF) VPP 105 VPP 205
1” Polypropylene Kynar (PVDF) VPP 110 VPP 210 VPP 310
Type Selection
Electrodes
Material Stainless steel
Standard length
VN, VNY 100 cm
VPC, VPP 50 cm
Diameter
VN, VNY Ø 5 mm
VPC, VPP Ø 4 mm
Housing
Connection
VN Cable (PVC), 2 m
VNY, VPC, VPP Screw terminals
Environment
Degree of protection IP 67
Operating temperature
VN, VNY 0º to 90ºC (32º to 194 ºF)
VPC 0º to 60ºC (32º to 140 ºF)
VPP 0º to 100ºC (32º to 212 ºF)
Storage temperature
VN, VNY -25º to 100ºC (-13º to 212ºF)
VPC, VPP -20º to 110ºC (-40º to 230ºF)
Pressure
VN, VNY, VPP 10 bar at 60°C
VPC 2 bar at 60°C
VPC 110
Types VN, VNY, VPC, VPP
Conductive
VN VNY VPC/VPP
2Specifications are subject to change without notice (25.06.99)
VN/VNI 1 VN/VNI 2 VN/VNI 3 VN/VNI 4
Mode of Operation
The length of the electrodes
determines the levels which
will be detected and the
amplifier chosen determines
the function (see SV...,
S195/196, S1961, ELA, ELC
or ELD). If the container is
made of a conductive mate-
rial this can be used as com-
mon electrode.
Dimensions
Pipe thread ISO 228/1-G 1 1/2”
Pipe thread ISO 228/1-G 1 1/2”
Pipe thread ISO 228/1-G 1/2”
Pipe thread ISO 228/1-G 1”
VN
VPC10, VPP10VPC05, VPP05
VNY
VN, VNY, VPC, VPP
Wiring Diagrams
BK
GY
BK
GY
BK
BU
BN
BK
BU
BN
BK
Accessories
Extension joint for Ø5 mm
electrodes (VN/VNI): VD1