1
G3VM-601G1
MOS FET Relays
Ultrasensitive MOS FET Relays in 600-V Load series
for electric power saving.
Continuous load current of 70 mA.
Application Examples
Terminal Arrangement/Internal Connections
List of Models
*The AC peak and DC value are given for the load voltage.
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
Communication equipment
Test & Measurement equipment
Security equipment
Amusement equipment
Industrial equipment
Various battery-driven devices
43
12
OMRON logo
Pin 1 mark
Model name
LOT.No.
932
Mold pin
mark *
-601G1
Note: The actual product is marked differently from the image shown here.
*The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
Package type Contact form Terminals Load voltage
(peak value) *Model Minimum package quantity
Number per tube
Number per tape and reel
SOP4 1a
(SPST-NO) Surface-mounting Terminals 600 V G3VM-601G1 100 -
G3VM-601G1 (TR) -2,500
Item Symbol Rating Unit Measurement conditions
Input
LED forward current IF30 mA
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Repetitive peak LED forward current
IFP 1 A 100 μs pulses, 100 pps
LED forward current reduction rate
ΔIF/°C0.3 mA/°C Ta 25°C
LED reverse voltage VR5 V
Connection temperature
TJ125 °C
Output
Load voltage (AC peak/DC)
VOFF 600 V
Continuous load current (AC peak/DC)
IO70 mA
ON current reduction rate
ΔIO/°C0.7 mA/°C Ta 25°C
Pulse ON current IOP 0.21 A t = 100 ms, Duty = 1/10
Connection temperature
TJ125 °C
Dielectric strength between I/O (See note 1.)
VI-O 1500 Vrms AC for 1 min
Ambient operating temperature
Ta 40 to +85 °C With no icing or condensation
Ambient storage temperature
Tstg 55 to +125 °C With no icing or condensation
Soldering temperature - 260 °C 10 s
Item Symbol
Minimum
Typical
Maximum
Unit Measurement conditions
Input
LED forward voltage VF1.11.271.4 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times
Reverse current IR- - 10 μA VR = 5 V
Capacity between terminals
CT- 30 - pF V = 0, f = 1 MHz
Trigger LED forward current
IFT --0.2mA IO = 70 mA
Output
Maximum resistance with output ON
RON - 35 60 Ω
I
F
= 0.5mA, I
O
= 70 mA, t < 1 s
Current leakage when the relay is open
ILEAK - 1 1000 nA VOFF = 600 V
Capacity between terminals
Coff - 75 - pF V = 0, f = 1 MHz
Capacity between I/O terminals
CI-O - 0.8 - pF f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
RI-O 1000 - - MΩ
V
I-O
= 500 VDC, R
O
H
60 %
Turn-ON time tON -210ms
IF = 0.5 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
Turn-OFF time tOFF -15ms
VOUT
IF
tONtOFF
10%90%
IF1
2
4
3
RLVDD
VOUT
2
G3VM-601G1 MOS FET Relays
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Engineering Data
Safety Precautions
Refer to "Common Precautions" for all G3VM models.
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD - - 480 V
Operating LED forward current
IF-0.525mA
Continuous load current (AC peak/DC)
IO--60mA
Ambient operating temperature
Ta 20 - 65 °C
LED forward current vs. Ambient temperature
Continuous load current vs. Ambient temperature
LED forward curren t vs. LED forward voltage
Continuou s load current vs. On-state voltage
On-state resistance vs. Ambient temperature
Trigger LED forward current vs. Ambient temperature
Turn ON, Turn OFF time vs. LED forward current
Turn ON, Turn OFF tim e vs. Amb ient tem perature
Current leakage vs. Ambient temperature
Current leakage vs. Load voltage
IF - Ta
Ambient temperature Ta (°C)
LED forward current I
F
(mA)
0
10
20
30
40
50
-40 -20 0 20 40 60 80 100
IO - Ta
Ambient temperature Ta (°C)
Continuous load current IO (mA)
0
20
40
60
80
100
-40 -20 0 20 40 60 80 100
IF - VF
LED forward voltage VF (V)
LED forward current IF (mA)
0.1
1
10
100
0.811.21.41.6
Ta = 25 °C
IO - VON
On-state voltage V
ON
(V)
Continuous load current I
O
(mA)
-80
-60
-40
-20
0
20
40
60
80
-3 -2 -1 0 1 2 3
Ta = 25 °C
IF= 1 mA, t < 1 s
RON - Ta
Ambient temperature Ta (°C)
On-state resistance R
ON
()
0
20
40
60
80
-40 -20 0 20 40 60 80 100
IO= 70 mA
IF= 0.5 mA, t < 1 s
IFT - Ta
Ambient temperature Ta (°C)
Trigger LED forward current I
FT
(mA)
0
0.1
0.2
-40 -20 0 20 40 60 80 100
IO
= 70 mA
t < 1 s
tON, tOFF - IF
LED forward current I
F
(mA)
Turn ON, Turn OFF time t
ON
, t
OFF
(ms)
0.01
0.1
1
10
0.1 1 10 100
tON
tOFF
VDD
= 10 V
RL
= 200
Ta = 25 °C
tON, tOFF - Ta
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFF (ms)
0.1
1
10
-40-200 20406080100
tOFF
tON
VDD
= 10 V
RL
= 200
IF
= 0.5 mA
ILEAK - Ta
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
-40 -20 0 20 40 60 80 100
100
10
1
0.1
0.01
VOFF
= 600 V
Load voltage V
OFF
(v)
Current leakage I
LEAK
(nA)
ILEAK - VOFF
0
0.2
0.4
0.6
0.8
1
0 100 200 300 400 500 600
Ta = 25 °C
Appearance/Dimensions SOP4 type
Appearance
Dimensions (Unit: mm)
Note: The actual product is marked differently from the image shown here.
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
SOP4
SOP (Small Outline Package)SOP (Small Outline Package)
OMRON logo
Pin 1 mark
Model name
LOT.No.
932
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
Mold pin mark *
-601G1
4.4
±0.25
3.9
±0.2
0.4
±0.1
2.54
±0.25
2.1 max.
0.1
±0.1
7.0
±0.4
0.6
±0.3
0.15
6 to 6.3
1.2
0.8
2.54
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Cat. No. K259-E1-02
0613(0613)(O)
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
G3VM-401G1(TR) G3VM-601G1(TR) G3VM-601G1