100
-40 0 25 50 80
60
50
100
‧2:1 wide input range
‧1500VDC I/O isolation
‧Built-in remote ON/OFF control
‧Built-in EMI filter
‧Protections: Short circuit / Overload
‧Cooling by free air convection
‧Single in line package
‧100% full load burn-in test
‧Low cost / High reliability
‧Modified models available: output 3.3V/9V
‧2 years warranty
SPECIFICATION
File Name:SPB05-SPEC 2014-10-09
ORDER NO.
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
SWITCHING FREQUENCY
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT
INPUT
(Note. 5)
ENVIRONMENT
SAFETY
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ISOLATION CAPACITANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
WEIGHT
FILTER
PROTECTION
VOLTAGE ACCURACY
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC
100KHz min.
±2.0%
±0.5%
±0.5%
80mVp-p
5W
90mVp-p 90mVp-p
100 ~ 1000mA
5V
SPB05A-05 SPB05B-05 SPB05C-05 SPB05A-12 SPB05B-12 SPB05C-12 SPB05A-15 SPB05B-15 SPB05C-15
12V
42 ~ 417mA
15V
33 ~ 333mA
A: 515mA B: 250mA C: 125mA
A: 40mA B: 25mA C: 15mA
I/P-O/P:1.5KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH℃
80pF max.
600Khrs min. MIL-HDBK-217F(25 )℃
-40 ~ +80 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-55 ~ +105 , 10 ~ 95% RH℃
± ℃ ℃0.05% / (0 ~ 55 )
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
21.8*9.2*11.1mm or 0.86"*0.36"*0.44" inch (L*W*H)
4.8g
1.All parameters are specified at normal input, rated load, 25 70% RH ambient. ℃
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
81% 83% 83% 85% 85% 85% 84% 85% 85%
Full load
No load
Capacitor Type
Mechanical Specification
Unit:mm(inch)
Pin Configuration Derating Curve
■ Features :
RIPPLE & NOISE (max.) Note.2
LINE REGULATION Note.3
LOAD REGULATION Note.4
OVERLOAD
SHORT CIRCUIT
150 ~ 250% rated output power
Protection type : Recovers automatically after fault condition is removed
All output equipped with short circuit
Protection type : Recovers automatically after fault condition is removed
Ta ( )℃
Pi n N o .
O u t p u t
1
2
3
5
6
7
8
-V i n
+ Vi n
R . C .
N . C .
+ Vo u t
- Vo u t
N . C .
5W DC-DC Regulated Single Output Converter SPB05 s e r i e s
Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8 light industry level, criteria A
PROTECTION Fuse recommended A: 1000mA B: 600mA C: 300mA Slow-Blow Type
FRONT VIEW
21.8(0.86)
1 2 3 5 6 7 8
2.54(0.1)
5.08
(0.2)
17.78(0.7)
3.81 0.5(0.15)±
0.5
(0.02)
0.5 0.05(0.02)±
BOTTOM VIEW
2.01(0.08)
2.4(0.09)
EMC IMMUNITY
EMC EMISSION
EXTERNAL CAPACITANCE LOAD (max.)
220uF
REMOTE CONTROL Power ON : R.C. ~ -Vin < 1VDC or open ; Power OFF : R.C. ~ -Vin > 4VDC or short