Multi-channel Controller Series PSE200 How to Order PSE20 0 M Option 2 Input/Output specifications 0 1 Nil NPN 5 outputs + Auto shift input PNP 5 outputs + Auto shift input 4C Unit specifications Nil M Without connector Sensor connector (4 pcs.) With unit display switching function Fixed SI unit Note) Note) Fixed unit For vacuum low pressure & compound pressure: kPa For high pressure: MPa Connector Option 1 Without panel mount/protective cover Nil Panel mount Accessory: Power supply/Output connection cable (2 m) Included with the controller. A Mounting screws (M3 x 8L) (Accessory) Waterproof seal (Accessory) Power supply/Output connection cable ZS-26-A Panel mount adapter Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) (Accessory) Front protective cover Waterproof seal (Accessory) Option When only optional parts are required, order with the part numbers listed below. Description Panel mount adapter ZS-26-B Part no. Front protective cover ZS-26-01 Front protective cover + Panel mount adapter ZS-26-C ZS-26-D Note Waterproof seal, screws included Waterproof seal, screws included 48 conversion adapter 48 conversion adapter This adapter is used to mount Series PSE200 on the panel fitting of Series PS100. Order panel mount adapter separately. Connector 16-3-6 ZS-26-E (4 pcs. per set) Panel mount adapter Panel Multi-channel Controller Series PSE200 Specifications PSE200 Model Output specification PSE201 Power supply voltage NPN open collector PNP open collector 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 55 mA or less (Current consumption for sensor is not included.) [Power supply voltage] -1.5 V Power supply voltage for sensor Power supply current for sensor Note 1) 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.) 1 to 5 VDC (Input impedance: Approx. 800 k) Sensor input With excess voltage protection (Up to 26.4 V) Input protection Variable Hysteresis mode Hysteresis PSE 3-digit fixed Window comparator mode 5 outputs (CH1: 2 outputs, CH2 to 4: 1 output) No. of outputs Z I 80 mA Maximum load current Switch output ZSE ISE 4 inputs No. of inputs 30 VDC (With NPN) Maximum load voltage Residual voltage 1 V or less (With load current of 80 mA) Output protection With short circuit protection PS Z I 5 ms or less Response time Anti-chattering function With anti-chattering function, Response time selection: 20 ms, 160 ms, 640 ms 0.5% F.S. 1 digit or less (at ambient temperature of 25 3C) Setting/Display accuracy ISA2 For measured value display: 4-digit, 7-segment indicator, Display color: Yellow Display For channel display: 1-digit, 7-segment indicator, Display color: Red IS Indication light Red (Lights up when output is ON.) Auto shift input Non-voltage input (Reed or Solid state), Input 10 ms or more, Independently controllable auto shift function ON/OFF Auto identification function Note 2) Enclosure With auto identification function Front face: IP65, Other: IP40 Resistance Operating/Stored: 35 to 85% RH (No condensation) Ambient humidity range Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance Power supply/Output connection: 8P connector, Sensor connection: 4P connector Connection Enclosure: PBT; Display: Transparent nylon; Back rubber cover: CR Material Approx. 60 g (Power supply/output connecting cable not included) Weight Applicable pressure sensor Regulating pressure range Set pressure resolution Note 3) IF Data 0.5% F.S. or less based on 25C Temperature characteristics ZSM PF2 Operating: 0 to 50C, Stored: -10 to 60C (No freezing or condensation) Ambient temperature range SE 12 ZSP 0.1% F.S. or less Repeatability SE3 PSE530 (For high pressure) PSE531 (For vacuum) PSE532 (For low pressure) PSE533 (For compound pressure) -0.1 to 1 MPa 10 to -101 kPa -10 to 101 kPa -101 to 101 kPa kPa -- 0.1 0.1 0.1 MPa 0.001 -- -- -- kgf/cm2 0.01 0.001 0.001 0.001 bar 0.01 0.001 0.001 0.001 psi 0.1 0.01 0.01 0.02 mmHg -- 1 -- 1 -- 0.1 -- 0.1 InHg Note 1) If the Vcc and 0 V side of the sensor input connector are short circuited, the inside of the controller will be damaged. Note 2) Auto identification function comes with "Series PSE53" pressure sensor only. Other SMC series (PSE510 and PSE520) are not equipped with this function. Note 3) For controllers with unit display switching function. (Either of SI units, [kPa] or [MPa], will be the set unit for those controllers without unit switching function.) 16-3-7 Series PSE200 Dimensions PSE200 & PSE201 40 40.1 18.7 6 6.5 Connector (option) MPa kPa PSE200 CH OUT2 1 2 3 36.8 OUT1 4 PRESSURE MADE IN JAPAN ZZ SET Connector (Option) Sensor connector (4P x 4) PIN no. Terminal DC (-) 4321 DC (+) IN (1 to 5 V) N.C. Power supply/Output connector (8P) Power supply/Output connection cable (Included) PIN no. Terminal DC (+) 7 Green : CH4_OUT1 DC (-) 6 Red : CH3_OUT1 CH1_OUT1 5 Gray : CH2_OUT1 CH1_OUT2 4 White : CH1_OUT2 CH2_OUT1 3 Black : CH1_OUT1 CH3_OUT1 2 Blue : DC (-) CH4_OUT1 1 Brown : DC (+) Auto shift input 16-3-8 Pin no. 8 Yellow : Auto shift input 2000 Multi-channel Controller Series PSE200 Dimensions Front protective cover + Panel mount 53 (2) 9.4 47 42.4 ZSE ISE MPa kPa CH 1 2 3 4 PSE 46.4 OUT1 OUT2 Z I PRESSURE SE3 PS SET Z I Panel mount adapter Front protective cover Waterproof seal 48 conversion adapter + Panel mount 6 48 SE 12 ZSP Panel 2 ISA2 1.5 IS ZSM PF2 MPa kPa IF OUT1 OUT2 CH 1 2 3 4 Data PRESSURE SET Panel mount adapter Waterproof seal 48 conversion adapter Panel 55 or more +0.1 55 or more 37.5 -0.2 Panel fitting dimension Applicable panel thickness: 0.5 to 8 mm 16-3-9 Series PSE530/200 Descriptions 4-digit display Unit display Displays the measured pressure value, content for each setting, and error code. MPa kPa Switch output display Unit labels kgf/cm2 bar PSI inHg mmHg OUT1 OUT2 1 UP button 2 3 CH 4 PRESSURE Use this button to change the mode or set value. SET DOWN button SET button Use this button to change the mode or set value. Use this button to set the mode or set value. Bring the pressure back to atmospheric pressure and use the reset function (zero point adjustment) again. * NPN open collector 5 outputs + Auto shift 1 input specification DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. 7.3 k Auto shift input (Yellow) CH1_OUT1 (Black) +12 to 24 VDC CH1_OUT2 (White) + CH2_OUT1 (Gray) - CH3_OUT1 (Orange) CH4_OUT1 (Pink) DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. DC (-) (Blue) PSE201-(M) Supply pressure exceeds the maximum regulating Reduce/Increase pressure. supply pressure to within the regulating Supply pressure is pressure range. below the minimum regulating pressure. * PNP open collector 5 outputs + Auto shift 1 input specification DC (+) (Brown) DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. Internal data error. 1.2 k Load DC (+) (Brown) DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. Load Shut off the power supply. After eliminating the output factor that caused the excess current, turn the power supply back on. PSE200-(M) Load Excess current is flowing into the switch output of OUT2. Pressure is applied to a pressure sensor during the reset operation (a zero point adjustment) as follows: When compound pressure is used: 2.5% F.S. or more. When pressure other than compound pressure is used: 5% F.S. or more. After displaying for 2 seconds, it will return to the measuring mode. Solution Load Contents Excess current is flowing into the switch output of OUT1. Please contact SMC. DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. 1.2 k 7.3 k Auto shift input (Yellow) CH1_OUT1 (Black) Main circuit LED display Internal Circuit and Connection Main circuit Error Code & Solution Channel display Displays the selected channel. Load Displays the output status of OUT1 (CH1 to CH4), OUT2 (CH1 only). Lights up when it is ON. The selected unit lights up. Use unit labels for units other than MPa and kPa. CH1_OUT2 (White) +12 to 24 VDC + CH2_OUT1 (Gray) - CH3_OUT1 (Orange) Internal data error. Internal data error. 16-3-10 Shut off the power supply and turn it back on. Please contact SMC if it does not recover. DC (-) (Blue) Load Load Load Load DC (+) Sensor input: +1 to 5 VDC DC (-) N.C. Load CH4_OUT1 (Pink) Internal data error. Multi-channel Controller/Pressure Sensor Series PSE530/200 Operation 1: Initial Setting 1 Channel selection MPa kPa OUT1 OUT2 1 2 3 4 CH CH1 PRESSURE CH2 CH3 CH4 ZSE ISE SET PSE Press SET button and hold for 2 seconds or longer. Z I 2 Range setting SE3 PS Z I MPa kPa ZSP OUT1 OUT2 1 2 3 4 CH PRESSURE Compound pressure Vacuum Low pressure High pressure ISA2 SET IS Note) Sensor range varies depending on the type of pressure sensor. Pressure Sensor/Sensor Range Sensor supply pressure Regulating pressure range Applicable pressure sensor (Compound pressure) -101 to 101 kPa PSE533 (Vacuum) 10 to -101 kPa PSE531 (Low pressure) -10 to 101 kPa PSE532 ZSM (High pressure) -0.1 to 1 MPa PF2 PSE530 IF If the controller is equipped with a unit switching function, unit setting can be changed. (Refer to page 16-3-17 for details.) SET Data 3 Output mode setting OUT1 setting MPa kPa or OUT1 OUT2 1 2 3 4 CH PRESSURE Normally Open Normally Closed SET (For CH2, CH3, and CH4, go to SET Response time setting.) OUT2 setting/(CH1 only) MPa kPa or OUT1 OUT2 1 2 3 4 PRESSURE SE 12 CH Normally Open Normally Closed SET SET 16-3-11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 1 2 3 4 CH PRESSURE 5 ms SET 20 ms 160 ms 640 ms Press SET button. Anti-chattering function Pressure Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the supply pressure. This function prevents such momentary drops from being detected as abnormal pressures by changing the response time setting. The pressure values measured within the response time that is selected by the user are averaged. By comparing this average pressure value with the set pressure value, switch output (ON//OFF) is determined. Momentary change Set value P1 P2 t (ms) t (ms) Time Switch output ON operation when normal OFF Time Switch output ON operation when anti-chattering OFF function is used. 5 Manual setting/Auto preset MPa kPa or OUT1 OUT2 1 2 3 4 CH PRESSURE Manual set mode SET Press SET button. CH1 setting is completed when the channel display changes from blinking to lights on. Repeat the same setting steps for CH2 to CH4. 16-3-12 Auto preset mode Time Multi-channel Controller/Pressure Sensor PSE530/200 Series Operation 2: Pressure Setting Manual setting Channel selection Output mode Measuring mode MPa kPa Hysteresis mode: Hysteresis of the switch output can be set arbitrarily. OUT1 OUT2 1 2 3 Hysteresis CH 4 ON PRESSURE CH1 CH2 CH3 Switch output 1 & 2 CH4 SET ZSE ISE OFF P2 P4 SET MPa ON OFF Z I OUT1 OUT2 1 2 3 CH 4 PRESSURE Increases the set value Decreases the set value For normally closed SET OUT1 setting (2) Displays alternately kPa 1 2 3 Increases the set value Decreases the set value CH 4 For normally closed PRESSURE SET P1 P3 ON Displays alternately OFF n1 n3 OUT1 2 3 Increases the set value Decreases the set value CH 4 For normally closed PRESSURE For CH2 to CH4 SET SET MPa 3 CH 4 PRESSURE For normally closed Increases the set value Decreases the set value SET Main application SET Manual mode For CH1 MPa Note 1) Display Hysteresis mode Window Note 2) comparator mode -101.0 to 101.0 kPa Adsorption and vacuum P2(n2) P1(n1) P2(n1) > P1(n2) 10.0 to -101.0 kPa Adsorption verification P2(n2) P1(n1) P2(n1) < P1(n2) -10.0 to 101.0 kPa Supply pressure P2(n2) P1(n1) P2(n1) > P1(n2) -0.1 to 1000.0 MPa P2(n2) P1(n1) P2(n1) > P1(n2) release verification Displays alternately OUT1 2 High pressure: Compound pressure type Positive pressure type High vacuum: Vacuum type Note) The hysteresis is set to 3 digits. When setting the pressure, allow 7 digits or more. Regulating pressure range For normally open kPa 1 n2 n4 (For CH1) OUT2 setting (2)/CH1 only Manual mode OUT2 Hysteresis Hysteresis Switch output 1 & 2 For normally open 1 High pressure: Compound pressure type Positive pressure type High vacuum: Vacuum type OUT2 setting (1)/CH1 only kPa OUT2 P2 P4 (For CH1) MPa verification Leak test P3(n3) and P4(n4) are the same as P1(n1) and P2(n2). Note 1) If the hysteresis is set too small, the switch output may possibly chatter when the input pressure changes around the set value. Note 2) The hysteresis is set to 3 digits. When setting the pressure in the window comparator mode, allow 7 digits or more. If the allowance is less than 7 digits, the controller will not operate. kPa OUT1 OUT2 1 2 3 Displays rectified value CH 4 PRESSURE SET For CH2 to CH4 ZSP ISA2 IS ZSM OFF Manual mode SE 12 PF2 ON Switch output 1 & 2 SET SET High pressure: Compound pressure type Positive pressure type High vacuum: Vacuum type Hysteresis Hysteresis OUT1 OUT2 n1 n3 Window comparator mode: Allows the switch output to be turned ON or OFF within any set pressure range. For normally open MPa n2 n4 Note) If the hysteresis is set for less than 2 digits, the switch output may possibly chatter when the input pressure changes around the set value. SET Manual mode SE3 PS Switch output 1 & 2 Displays alternately PSE Z I Hysteresis For normally open kPa High pressure: Compound pressure type Positive pressure type High vacuum: Vacuum type OUT1 setting (1) Manual mode P1 P3 Displays zero when the auto shift input function is not turned on. SET To measuring mode 16-3-13 IF Data Series PSE530/200 Operation 2: Pressure Setting Auto preset Channel selection Measuring mode MPa kPa OUT1 OUT2 1 2 3 CH 4 PRESSURE CH1 CH2 CH3 CH4 SET Adsorption Verification SET High Auto preset mode MPa kPa OUT1 auto preset preparation Prepare the equipment to be set in this mode. Vacuum Suction Work 1 Work 2 Work n Max. A ON OUT1 OUT2 1 2 3 OFF CH 4 PRESSURE Min. B Released Work 1 SET Atmosphere SET kPa OUT1 OUT2 1 2 3 CH 4 PRESSURE ( In the case where OUT1 setting is not required. ) For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically. For supply pressure verification: The optimum values will be set automatically. SET + SET OUT2 auto preset preparation (CH1 only) MPa kPa OUT1 OUT2 1 2 3 CH 4 PRESSURE For adsorption verification: Change the conditions of the workpiece such as the (suction) nozzle with vacuum pad attachment and supply vacuum pressure. For supply pressure verification: Prepare the equipment for the OUT2 setting in this mode. SET SET OUT2 auto preset (CH1 only) MPa kPa OUT1 OUT2 1 2 3 CH 4 PRESSURE SET ( In the case where OUT2 setting is not required. 16-3-14 ) SET To measuring mode For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically. For supply pressure verification: The optimum values will be set automatically. + Work n Min. B: Minimum pressure value when workpiece is not adsorbed. OUT1 auto preset MPa Work 2 Max. A: Maximum pressure value when workpiece is adsorbed. ON = A - A - B 4 OFF = B + A - B 4 Multi-channel Controller/Pressure Sensor Series PSE530/200 Operation 3: Special Setting 1 Precision indicator setting Refer to A Display calibration function on page 16-3-17 for details. Calibration mode Measuring mode + SET MPa kPa Press and hold for 2 seconds or longer. OUT1 OUT2 1 2 3 CH 4 PRESSURE ZSE ISE SET SET PSE or Channel selection Z I Calibration mode After setting all 4 channels, press SET button. PS MPa Proceed to the copy mode. kPa Z I OUT1 OUT2 1 2 3 CH 4 SE3 SE 12 PRESSURE Setting is complete (CH1). Return to calibration mode. Repeat the setting procedure for CH2 to CH4. SET SET ZSP SET ISA2 IS Calibration mode Displays alternately SET Displays alternately ZSM MPa kPa OUT1 OUT2 1 2 3 Displays the supply pressure value CH 4 PRESSURE button increases the value. SET 2 Copy setting button decreases the value. Copy mode or OUT1 Selection of the channel to be copied MPa kPa kPa OUT1 OUT2 1 2 3 CH 4 OUT2 1 PRESSURE 2 3 CH 4 PRESSURE SET SET SET Copy mode MPa kPa Selection of the channel to be copied to Displays alternately OUT1 SET OUT2 1 2 3 CH 4 PRESSURE ( After setting for copy mode, press SET . ) Proceed to the auto shift mode. PF2 IF Data Refer to B Copy setting function on page 16-3-17 for details. Copy mode MPa Displays the percentage. Displays the adjusted amount of pressure since the time of shipment (5% R.D. or less). SET SET Setting is complete. Return to the copy mode. 16-3-15 Series PSE530/200 Operation 3: Special Setting 3 Auto shift Refer to C Auto shift function on page 16-3-17 for details. Auto shift mode MPa or MPa kPa kPa OUT1 Displays alternately OUT1 OUT2 1 2 3 4 OUT2 CH 1 PRESSURE 2 3 CH 4 PRESSURE SET CH1 On Off On Off On Off On Off SET SET MPa kPa Displays alternately OUT1 OUT2 1 2 3 CH 4 PRESSURE CH2 SET SET MPa kPa SET Displays alternately OUT1 OUT2 1 2 3 CH 4 PRESSURE CH3 SET SET MPa kPa Displays alternately OUT1 OUT2 1 2 3 CH 4 PRESSURE CH4 SET SET 4 Auto identification Setting is complete. Proceed to the auto identification mode. Refer to D Auto identification function on page 16-3-17 for details. Auto identification mode MPa or MPa kPa OUT1 kPa OUT1 OUT2 1 2 3 4 CH PRESSURE SET Auto identification mode ON. SET Setting is complete. To measuring mode 16-3-16 OUT2 1 2 3 4 CH PRESSURE SET Auto identification mode OFF. Series Multi-channel Controller/Pressure Sensor PSE530/200 Function Details A Display calibration function Displayed pressure value This function eliminates slight differences in the output values of all 4 channels and allows uniformity in the numbers displayed. Displayed values of the pressure sensors can be adjusted to within 5%. 5% R.D. 0 B Copy function Information that can be copied includes the following: q Pressure set values, w Range settings, e Display Units, r Output modes, t Response times. * When CH1 is copied to CH2, CH3, and CH4, information of OUT1 in CH1 will be copied. + Applied pressure * When CH2, CH3, or CH4 is copied to CH1, information of OUT1 in CH2, CH3, or CH4 will be copied only to OUT1 in CH1. Note) When the copy function is used, the regulating pressure value of the copied channel may change 1 digit. PSE Displayed value at the time of shipment Z I Adjustable range of display calibration function Note) When the display calibration function is used, the regulating pressure value may change 1 digit. C Auto shift function If there is a fluctuation in the supply pressure, erroneous operation may occur (e.g., in the case of adsorption verification, the switch does not turn ON even though the workpiece is being adsorbed, or does not turn OFF even though the workpiece is no longer being adsorbed.) The auto shift function rectifies pressure changes to ensure proper ON/OFF switch response during such fluctuations. At the point when the supply pressure fluctuates, the set pressure value is rectified by setting the auto shift input (external input) to Lo (no-voltage input), using the pressure measured at that point as a standard. * This function is good only for those channels whose function selection is turned "on" during the auto shift mode setting. Set value Supply pressure drop Supply pressure normal Pressure ISA2 P1 P2 IS Time Switch output ON 1&2 OFF Does not turn ON When auto shift is used: Pressure Note) Rectified values are not saved in EEPROM. D Auto identification function This function automatically identifies the pressure range of the pressure sensor that is connected to the multi-channel pressure sensor controller, thus eliminating the need of having to reset the range again after replacing the sensor. This function will be activated either when "Aon" is set in the auto identification mode or when the power is turned back on in that condition. However, this function only works in conjunction with specific pressure sensors (SMC Series PSE53). When other pressure sensors are used, this function will not work. When using other types of pressure sensors, first set the auto identification mode to "AoF", and then proceed to setting the range. Turning the power back on while in the "Aon" setting can cause a malfunction. PF2 Supply pressure normal IF Set value rectification Set value rectification Supply pressure drop Data Supply pressure increase P1 P2 Time Switch output ON 1&2 OFF * When all of the auto shift functions are turned "off", "ooo" will not be displayed even if the auto shift input is set to Lo (no-voltage input). * Values "C_5" and "C_3", rectified after the auto shift function is used, will be reset to zero (initial value) when the power is turned back on again. ZSM Does not turn OFF Time Set value 10 ms or more 15 ms or less ( Time Switch output response time when auto shift is input. Hi Auto shift input SE 12 ZSP Supply pressure increase * When the auto shift function is turned "off", the shift value will be zero. * Values "C_5" and "C_3", rectified after the auto shift is input, will be lost once the power is turned off. Z I When auto shift is NOT used: When the supply pressure fluctuates, a correct sensing is no longer possible. * The time from the moment the auto shift is input, to the moment the switch output actually operates is 15 ms or less. * If the set value rectified by the auto shift input exceeds the regulating pressure range, it will be rectified once more to within the values of the regulating pressure range. SE3 PS * Maintain the constant pressure for 10 ms or more after a drop in the auto shift input. * When the auto shift is input, "ooo" will be displayed for approximately 1 second, and the pressure value at that point will be saved as a rectified value "C_5" (for CH1) or "C_3" (for CH2 and CH3). Based on the saved rectified values, the set value "P_1" to "P_4" or "n_1" to "n_4" will likewise be rectified. ZSE ISE Lo E Unit display switching function Display units can be switched with this function. Units that can be displayed vary depending on the range of the pressure sensors connected to the controller. . or Display units can be selected using either Unit Display and Resolution Applicable pressure sensor PSE530 PSE531 PSE532 PSE533 Regulating pressure range -0.1 to 1 MPa 10 to -101 kPa -10 to 101 kPa -101 to 101 kPa kPa -- 0.1 0.1 MPa 0.001 -- -- -- kgf/cm2 0.01 0.001 0.001 0.001 bar 0.01 0.001 0.001 0.001 psi 0.1 0.01 0.01 0.02 mmHg -- 1 -- 1 inHg -- 0.1 -- 0.1 0.1 16-3-17 ) Series PSE530/200 Operation 4: Other Functions Measuring mode Reset + Press and hold for 1 second or longer. Key lock Measuring mode Lock/Unlock selection SET SET Press and hold for 4 seconds or longer. Lock Unlock To measuring mode Note) Channel selection and channel scan operation will not be locked even if the key lock function is on. Peak/Bottom display Measuring mode Peak/Bottom selection Press and hold for 2 seconds or longer.Peak/Bottom mode OFF SET Bottom mode Peak mode SET SET Measuring mode Peak value blinks Bottom value blinks To return to the measuring mode, press any of these keys. SET If any buttons other than above are pressed during the peak/bottom mode, the peak/bottom mode will be deactivated. Measuring mode Channel scan Press and hold for 2 seconds or longer. CH1 CH2 CH4 CH3 Press and hold for 2 seconds or longer. Channel scan function deactivated. Return to the measuring mode. Pressure value for each channel are displayed at 2 second intervals. 16-3-18 Series PSE Specific Product Precautions 1 Be sure to read before handling. Controller Pressure Sensor Handling Handling 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 23 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor--do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. Do not use pressure sensors with corrosive and/or inflammable gases or liquids. 5. Connecting the sensor cable (Option) 1. Do not drop, bump, or apply excessive impacts (1000 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause a malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N. Applying a greater pulling force than the applicable specified tensile strength to either of these components can lead to a malfunction. When handling, hold the body of the controller--do not dangle it from the cord. Warning Warning Hold the female connector of the sensor cable with your fingers and carefully insert it into the connector. Sensor Male connector Female connector A connector cover is provided as part of the cable assembly (see the figure below). It is designed to keep the female connector from slipping out of the sensor. To lock the connector cover in place, first make sure it is facing in the right direction as you slip it over the female connector, then lock it to the sensor body by turning it clockwise. To remove the cover, first unlock it by turning it counterclockwise, then pull back on it. To remove the female connector, grab it with your fingers and pull back on it. Do not pull on the cable. Lock Sensor Connector cover Unlock Operating Environment Warning 1. The pressure sensors are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. ZSE ISE PSE Z I SE3 PS Z I SE 12 ZSP ISA2 Connection Warning IS 1. Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output. Connections should be done while the power is turned off. 2. Do not attempt to insert or pull the pressure sensor or its connector when the power is on. Switch output may malfunction. 3. Wire separately from power lines and high voltage lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise from these other lines. 4. If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. Operating Environment Warning 1. Our multi-channel pressure sensor controllers are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. Our multi-channel pressure sensor controllers do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. 3. Enclosure "IP65" applies only to the front face of the panel when mounting. Do not use in an environment where oil splashing or spraying are anticipated. 16-3-19 ZSM PF2 IF Data Series PSE Specific Product Precautions 2 Be sure to read before handling. Mounting Wiring Caution Caution The front face of the panel mount conforms to IP65 (IP40 when using the 48 conversion adapter); however, there is a possibility of liquid filtration if the panel mount adapter is not installed securely and properly. Securely fix the adaptor with screws as shown below. 1. Connecting sensor cable and connector (ZS-26-E) * Cut the sensor cable as shown below. * Insert each lead wire into the corresponding connector number by following the chart provided below. Connector no. Standard Front protective cover (ZS-26-01) Panel mount (ZS-26-B) 2-M3 x 8L Tighten screws 1/4 to 1/2 turn after the heads are flush with the panel. When using 48 conversion adapter Core wire color of sensor cable 1 Brown (DC+) 2 Black (Analog output) 3 Blue (DC-) 4 N.C. 20 mm or more Brown Black Blue N.C. 1 2 3 4 * Make sure that the number of connector and the core wire color match. After verifying that the wires are inserted all the way, temporarily hold the connector down manually. * Using pliers, snap A into B as shown below so that there is no gap between A and B, and secure the connector. * The A and B portion of the sensor connector are already tacked down temporarily at the time of shipment. Do not snap the A portion in place before inserting the cable. Note that the connector cannot be taken apart to be reused once it is crimped. Use a new sensor connector in case wiring or the snapping of A into B are done incorrectly. 48 conversion adapter (ZS-26-D) B 4321 A 432 1 432 1 Verify from the top side of A that the lead wires are inserted completely. * To connect the connector to the multi-channel pressure sensor, push the connector with its A portion facing toward you into the socket until it clicks as shown below. * To remove the connector, pull it straight out while applying pressure to the fingers on both sides. 1 2 3 4 Sensor connector port Power supply/Output connector 2. Connecting power supply/output connection cable * To connect the power supply/output connection cable to the controller, insert the cable connector with the C part facing down until it clicks. C 2m 16-3-20 Series PSE Specific Product Precautions 3 Be sure to read before handling. Wiring Caution 3. Connecting to other series ZSE ISE * Any pressure sensor (SW) can be connected as long as it generates analog output (1 to 5 V) signal. However, the pressure range must match. * SMC pressure sensors, Series PSE510 & PSE520, are also connectable. * When connecting to pressure sensors other than the Series PSE530, connector types will vary depending on the wire core size of the cable and the outside diameter of the insulation cover. Refer to the table provided below. Connector part no. ZS-26-E ZS-26-E-1 ZS-26-E-2 ZS-26-E-3 PSE Z I PS Z I Insulation Sensor part no. cover Wire core size O.D. AWG24-26 (0.14 to 0.2 mm2) o1.0 to 1.4 PSE510, PSE530 AWG24-26 (0.14 to 0.2 mm2) o1.4 to 2.0 AWG20-22 (0.3 to 0.5 mm2) o1.0 to 1.4 PSE521 AWG20-22 (0.3 to 0.5 mm2) o1.4 to 2.0 PSE520 ISA2 IS ZSM PF2 1 2 3 4 IF Data F.G. Connect the shielding wire to the frame ground (F.G.) or F.G. terminal. ( There is no shielding wire for Series PSE510 & PSE530. SE 12 ZSP * Refer to the following diagram for connecting Series PSE520 to the connector. Brown Black Blue N.C. SE3 ) Regulating Pressure Range & Rated Pressure Range Caution 1. Regulating pressure range: Refers to allowable pressure range in a pressure setting mode. * Setting range is between P_1(n_1) to P_4(n_4). * For Series PSE200, the regulating pressure range and the setting pressure range that can be displayed are the same. 2. Rated pressure range: Refers to the pressure range that satisfies the product specifications. * Pressure range that satisfies the product specifications (accuracy and linearity) for PSE530. 16-3-21 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 16-14-3 Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. Selection Warning 1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. Do not use the product outside their design parameters. Please contact SMC when using the products in applications other than compressed air (including vacuum). Mounting Warning 1. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 4. Use clean air If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. Operating Environment Warning 1. Do not use in environments where the product is directly exposed to corrosive gases, chemicals, salt water, water or steam. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibrations and/or shocks. 4. Do not mount the product in locations where it is exposed to radiant heat. Maintenance 2. Securing the space for maintenance When installing the products, please allow access for maintenance. 3. Tightening torque When installing the products, please follow the listed torque specifications. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Air Supply Warning 1. Operating fluid Please consult with SMC when using the product in applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SMC about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to "Air Preparation Equipment" catalog. 16-14-4 Warning 1. Maintenance procedures are outlined in the operation manual. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 3. Drain flushing Remove drainage from air filters regularly. (Refer to the specifications.) 4. Shut-down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. Start-up after maintenance and inspection Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation is abnormal, please verify product set-up parameters. 6. Do not make any modifications to be product. Do not take the product apart. Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards "ISO 9001" and "ISO 14001", and created a complete structure for quality assurance and environmental controls. SMC products pursue to meet its customers' expectations while also considering company's contribution in society. SMC's quality control system Make customers our first priority, offering them reliable and friendly service. Produce the highest quality with the participation of all employees. Create new products using the latest technology, and offer the finest products in a timely manner. Quality policies Market research Product planning After service Sales coordination Quality management system ISO 9001 This is an international standard for quality control and quality assurance. SMC has obtained a large number of certifications in Japan and overseas, providing assurance to our customers throughout the world. Quality system education Training of suppliers Research Education Design Training Development Production New product evaluation Reliability design Reliability testing New technical development Process control Inspection, testing, etc. Initial production control Quality control activities Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SMC is also making diligent efforts to preserve the environment. 16-14-5 SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once "A manufacturer himself" declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP (European hydraulics and pneumatics committee) guide lines. As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark, Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg EC Directives and Pneumatic Components * Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File required for a Declaration of Conformity. * Electromagnetic Compatibility (EMC) Directive The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). * Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. * Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards. Mark of compliance for CSA/UL Mark of compliance for CSA CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA or UL standards are accepted in most states and governments beyond question. Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard With CE symbol for simple visual recognition In this catalog each accredited product series is indicated with a CE mark symbol. However, in some cases, every available models may not meet CE compliance. Please visit our web site for the latest selection of available models with CE mark. http://www.smcworld.com 16-14-7 SMC's Global Service Network America Europe U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 U.K. SMC Pneumatics (U.K.) Ltd. Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. TEL: 01908-563888 FAX: 01908-561185 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 GERMANY SMC Pneumatik GmbH Boschring 13-15 D-63329 Egelsbach, Germany TEL: 06103-4020 FAX: 06103-402139 MEXICO SMC Corporation (Mexico), S.A. DE C.V. Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 ITALY SMC Italia S.p.A. Via Garibaldi 62 I-20061 Carugate Milano, Italy TEL: 02-9271365 FAX: 02-9271365 CHILE SMC Pneumatics (Chile) S.A. Av. La Montana 1,115 km. 16,5 P. Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 ARGENTINA SMC Argentina S.A. Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 BOLIVIA SMC Pneumatics Bolivia S.R.L. Avenida Beni Numero 4665 Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia TEL: 591-3-3428383 FAX: 591-3-3449900 VENEZUELA SMC Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, Local 5, Caracas 1040-A, Venezuela TEL: 2-632-1310 FAX: 2-632-3871 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 SWEDEN SMC Pneumatics Sweden AB Ekhagsvagen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 SWITZERLAND SMC Pneumatik AG Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland TEL: 052-396-3131 FAX: 052-396-3191 AUSTRIA SMC Pneumatik GmbH (Austria) Girakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 SPAIN SMC Espana, S.A. Zuazobidea 14 Pol. Ind. Jundiz 01015 Vitoria, Spain TEL: 945-184-100 FAX: 945-184-510 PERU (Distributor) IMPECO Automatizacion Industrial S.A. AV. Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay TEL: 2-401-6603 FAX: 2-409-4306 NETHERLANDS (Associated company) SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands TEL: 020-5318888 FAX: 020-5318880 BRAZIL SMC Pneumaticos Do Brasil Ltda. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogota, Colombia TEL: 1-424-9240 FAX: 1-424-9260 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 16-14-20 SMC's Global Service Network Europe Oceania/Asia FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Naeringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland TEL: 022-548-5085 FAX: 022-548-5087 HONG KONG SMC Pneumatics (Hong Kong) Ltd. 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon, Hong Kong TEL: 2744-0121 FAX: 2785-1314 TURKEY (Distributor) Entek Pnomatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Turkiye TEL: 0212-221-1512 FAX: 0212-221-1519 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia TEL: 812-118-5445 FAX: 812-118-5449 CZECH SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 HUNGARY SMC Hungary Ipari Automatizalasi kft. Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 ROMANIA SMC Romania S.r.l. Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania TEL: 01-3205111 FAX: 01-3261489 SLOVAKIA SMC Priemyselna automatizacia, s.r.o Nova 3, SK-83103 Bratislava TEL: 02-4445-6725 FAX: 02-4445-6028 SLOVENIA SMC Industrijska Avtomatilca d.o.o. Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia TEL: 07388-5240 FAX: 07388-5249 SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.Box 240 Paardeneiland 7420 South Africa TEL: 021-511-7021 FAX: 021-511-4456 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 PHILIPPINES SHOKETSU SMC Corporation Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines TEL: 02-8090565 FAX: 02-8090586 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam Selangor, Malaysia TEL: 03-56350590 FAX: 03-56350602 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 CHINA SMC (China) Co., Ltd. 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China TEL: 010-67882111 FAX: 010-67881837 THAILAND SMC Thailand Ltd. 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 02-963-7099 FAX: 02-501-2937 INDIA SMC Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 INDONESIA (Distributor) P.T. Riyadi Putera Makmur Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21