B
a ff
u
GEIEC
Devices
C-2000™
3-Pole Contactors
Nonreversing
and
Reversing
AC/DC
Controlled
5-25
Hp
(460
V) DC
Only
To
complete
the
contactor
catalog
number,
replace
the
digit from
the
Coil Selection table.
in
the
catalog
number with
the
appropriate
AC-3
Max.
Amps
@460V
10
13.8
17.5
22
32
34
Single-phase-HP
60 Hz
115V
0.5
0.75
1
1.5
2
3
230V
1.5
2
3
3
5
5
Three-phase-HP
60 Hz
200V
3
3
5
5
10
10
230V
3
3
5
7.5
10
10
460V
5
7.5
10
15
20
25
575V
7.5
10
15
15
25
25
KW
50
Hz
380/
415V
4
5.5
7.5
11
16
18.5
Aux.
Contacts
(A600,
Q600)
1NO
1NO
1NO
1NO<2
1NO
1NO®
Coil
Volts
DC
DC
DC
DC
DC
DC
Nonreversing
Catalog
No.
CLOOD310T*
CL01D310T*
CL02D310T"
CL25D310T*
CL04D310M*
CL45D310M*
List
Price,
GO-10C2
$109.00
133.00
147.00
166.00
195.00
252.00
Reversing
(D
Catalog
No.
LDROOA*
LDR01A*
LDR02A*
LDR25A*
LDR04A*
LDR45A*
List
Price,
GO-10C2
$290.00
337.00
366.00
399.00
495.00
609.00
©
Reversing contactor consists
of two (2)
contactors,
a
mechanical interlock (BEL02) with built-in
NC
cross
electrical
contact,
power
wiring
and
cross
electrical
wiring
and
holding
interlock.
@
Nonreversing: A1NO front mounted auxiliary contact block
is
supplied (unassembled) with contactors that
begin with CL25
and
CL45.
Add
suffix
"S" to
catalog number
for
1
NO-1
NC
side auxiliary (assembled),
add
$11.00
GO-10C2
to
list
price
(example:
CL45D310MKS,
list
price
$252.00
+
$11.00
=
$263.00
GO-10C2)
Reversing: Reversing contactors with prefixes LDR25A
and
LDR45A supplied with
1NO
front-mounted
holding
interlock mounted
on
each contactor.
Add
suffix
"S" to
catalog number
Tor
1NO-1NC
side auxiliary
(assembled),
add
$22.00
GO-10C2
to
list price (example: LDR25AKS,
list
price
$399.00
+
$22.00
=
S421.00GO-10C2)
30-75
Hp
(460
V)
AC/DC
To
complete
the
contactor catalog number, replace
the t in the
catalog number with
the
appropriate
digit
from
the
Coil Selection table.
AC-3
Max.
Amps
©460V
48
62
68
80
96
Single-phase-HP
60 Hz
115V
3
5
5
7.5
10
230V
7.5
10
15
15
20
Three-phase-HP
60 Hz
200V
15
20
20
25
30
230V
15
20
25
30
40
460V
30
40
SO
60
75
575V
40
50
60
75
75
KW
50 Hz
380/
415V
22
30
37
45
55
Aux.
Contacts
(A600,
Q600)
1NO®
1NC
1NO<5>
1NC
1NO<5>
1NC
1NO<3>
1NC
1NO<3>
1NC
Coil
Volts
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
Nonreversing
Catalog
No,
CL06E311Mt
CL07E311Mt
CL08E311Mt
CL09E311Mt
CL10E311Mt
List
Price,
GO-10C2
$265.00
279.00
364.00
404.00
520.00
Reversing
CD
Catalog
No.
LER06At
LER07At
LEROSAt
LEROSAt
LERIOAt
List
Price,
GO-10C2
$675.00
703.00
873.00
1,003.00
1,235.00
*Coil
Selection Table
(CLOO,
CL01,
CL02,
CL25,
CL04,
CL45)
DC
Voltage
12
24
48
125
250
tCoil
Suffix
B
D
G
K
T
Note:
Additional coils available,
see
page
3-16.
tCoil
Selection Table
(CL06,
CL07, CL08,
CL09,
CL10)
AC/DC
Voltage
24-28
42-48
110-127
220-250
380-415
440-500
ttCoil
Suffix
D
F
J
N
U
Y
Nonreversing: A1NO
and 1NC
front-mounted auxiliary contact block
are
supplied (unassembled) with
contactors
that begin with CL06, CL07, CL08, CL09,
and
CL10.
Add
suffix
"S" to
catalog number
for
1NO-1NC
side auxiliary (assembled),
no
addition
in
price adder.
Reversing: Reversing contactors with prefixes LER06, LER07,
LER08,
LER09,
and
LER10
supplied with
1NO
and11NC
front-mounted auxiliary
on
each contactor.
Add
suffix
"S" to
catalog number
for
1NO-1NC
side
auxiliary,
no
additional price adder.References: Instructions Overload Relays
............
pages
3-8,3-9
GEH-6223
CLOO-CL25
Contactors
Accessories
............
pages 3-10
to
3-16
GEH-6224 CL03-CL45 Contactors Enclosures
.............
pages 3-17
to
3-19
GEH-6225
CL05-CL08 Contactors Technical Data
..........
pages
3-36
to
3-44
GEH-6226
CL09-CL10
Contactors
Prices
and
data subject
to
change
without
notice
1999
Issue
3-5
LJ-
GEIEC
Devices
General
Specifications
for
C-2000™
Contactors
&
Starters
Standards
And
Listings
EC
947-1
EC
947-4
EC
158-1
CENELECHD419
NFC.63-110
BS
5424
BS775
CEI 1
7-3/252
ASE 1 025
UL508
CSAC.22.2/14
EN
50005
UNE20109
VDE
0660/1
02
CE
Mark
ZH1/457
(Positive
Guided
Contacts)
Pending Standards
And
ListingsSEMKO, NEMKO, DEMKO, Lloyds Register
Ambient Temperature
Operating
Storage
.
-13°
to
+131°F/-25°to
+55°C
-58°
to
+176°F/-50°to
+80°C
Altitude Derating
Up to
10,000
ft. ;
(3,000
m)
10,000
to
13,200
ft.
(3,000
to
4,000
m)
13,200
to
16,000
ft.
(4,000
to
5,000
m)
Nominal Values
90%
rated current
80%
rated current
Rated
Insulation Voltage
600
Vac,
U,
=
1000V
(per
EC
947)
Mounting
Position
3-Pole
and
4-Pole
CL
Contactors (5-75
Hp)
To
maintain operating integrity,
the
contactor must
be
mounted
in one of the
positions shown below:
i)
o
o o
]QDOQ[
o
o o
I
o
o
o
!dH
BS
F!F!
o
o
o
J
o o o
DDDDDD
DDDDQD
000
[
o
o
o
HH
D 1=1
a
1=1
a en
O
o
o
3-Pole
and
4-Pole
CK
Contactors
(100-500
Hp)
The
contactor must
be
installed vertically
or
tilted
a
maximum
of 30°
from vertical,
as
shown below:
3-36
1999
Issue
Data
subject
to
change
without