PK-110 Electrical Test Kit Three Electrical Testers to Perform Quick and Safe Voltage Tests Amprobe's PK-110 Electrical Test Kit offers three electrical testers with testing functions suitable for a variety of residential applications. The kit includes the AM-420 Digital Multimeter, ST-102B Socket Tester with GFCI and VP-1000 Non-Contact Voltage Detector. From identifying voltage presence in outlets and switches to confirming proper wiring of regular and GFCI protected outlets, the PK-110 kit boasts all the features needed to perform quick and safe electrical tests. Troubleshoot light bulbs, fuses and detect voltage Quickly verify voltage presence AM-420 Test receptacles and GFCI breakers VP-1000 ST-102B PK-110 Features AM-420 Digital Multimeter * * * * * * * AC/DC Voltage DC Current Resistance Audible Continuity and Diode Test Battery Test (1.5V and 9V) Data Hold Safety Rated: CAT II 250 V VP-1000 Non-Contact Voltage Detector ST-102B Socket Tester with GFCI * AC Voltage Detection * Visual Voltage Presence Alert * Safety Rated: CAT IV 1000 V * * * * Tests Standard and GFCI Outlets Verifies Proper Wiring Detects Five Different Wiring Faults CSA Listed for Safety 250 V Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6004306 A PK-110 Applications AM-420 Digital Multimeter VP-1000 Non-Contact Voltage Detector ST-102B Socket Tester with GFCI AM-420 Digital Multimeter VP-1000 Non-Contact Voltage Detector ST-102B Socket Tester with GFCI Accurately measure voltage up to 250V in receptacles, switches, extension cords and light fixtures Troubleshoot light bulbs and fuses with the continuity function Check 1.5V and 9V batteries Test extension cords and verify proper wiring of an outlet with voltage function CAT II 250 V safety rating Easily and safely detect voltage presence between 90 and 1000 V. Quickly verify voltage presence in outlets, switches, extension cords, circuit breakers and fuses without disconnecting the electrical system. Bright LED alerts when voltage is present Test receptacle wiring and confirm GFCI sockets are properly wired with push button Detect five different wiring faults open ground, open neutral, open hot, hot/ground reverse, and hot/neutral reverse Three illuminated lights on the tester indicate the type of wiring problem Operates as `always on' using low power circuitry with no buttons for increased safety Double insulated, CAT IV 1000V safety rating Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6004306 A PK-110 Detailed Specifications Feature AM-420 Best Accuracy AC Voltage 200.0 / 250 V +/-(1.5% rdg + 4 LSD) @ 45 Hz to 400 Hz DC Voltage 200 mV 2.000 / 20.00 / 200.0 / 250 V 200.0 A 2.000 / 20.00 / 200.0 mA 200.0 2.000 / 20.00 / 200.0 k 2.000 M DC Current Resistance +/-(1.2% rdg + 2 LSD) @ 200 mV to 200 V +/-(1.2% rdg + 5 LSD) @ 200 A to 20 mA +/-(1.5% rdg + 5 LSD) @ 200 to 200 k Continuity Beeps at 10 , off at >70 Diode Test Open-circuit voltage is around 1.5V. Normal voltage is around 0.5V to 0.8V for silicon PN junction. Battery Test Data Hold 1.5 V, 9 V +/-(8.0% rdg + 1 LSD) * General Specifications: Maximum Display 1999, updates 2 to 3/sec Range Manual-ranging Operating Temperature Relative Humidity 32F ~ 104F (0C ~ +40C) 32F ~ 86F (0C ~ +30C) 75%; 86F ~ 104F (+30C ~ +40C) 50% Operating Altitude 2000 m Storage Temperature Electromagnetic Compatibility 14F ~ 122F (-10C ~ +50C) In an RF filed of 1V/m = Specified accuracy 5%. RF field > 1V/m is not specified. Over-range Indication Battery " 1 ", "-1" or maximum display reading One 9V alkaline battery (6LF22, 6LR61, MN1604) or equivalent Battery Life Alkaline: 100 hours typical Low Battery Indication Overvoltage Category Safety Compliance CAT II 250V safety rated IEC 61010-1, UL 61010-1 2nd Ed. and CAN/CSA C22.2 No. 61010-1-04 Update No.1:2008 EMC Compliance IEC 61326-1 Certification cCSAus and CE Dimensions (L x W x H) Weight 4.5 x 2.6 x 1.6 in (115 x 65 x 40 mm) Approximately 0.61 lb (275 g) with battery installed Feature VP-1000 90 Vac 1000 Vac, 50/60 Hz Operating Voltage Range Sensitivity Lights at approx. 0.39 in (10 mm) distance from a wire carrying 120 Vac Operating Temperature Storage Condition 32F to 104F (0C to +40C), 80% RH 14F to 122F (-10C to +50C), 95% RH Operating Altitude 2000 meters Power Supply Two 1.5 V AAA batteries Dimensions (L x W x H) 6.10 x 0.96 x 0.85 in (155 x 24.5 x 21.5 mm) Weight Approx. 0.11 lb (50 g) with batteries installed Safety Compliance IEC 61010-1, UL 61010-1 2nd Ed. and CAN/CSA C22.2 No. 61010-1-04 EMC Compliance IEC 61326-1 Certification cCSAus and CE Feature ST-102B Operating Voltage 110 - 125 Vac, 50 - 60 Hz Wattage 0.3 W Actuator Black button Indicator Red LED, three lights, neon Lamp Lens Colors Six Conditions Indicated Safety Compliance One red, two amber Open ground, open neutral, open hot, hot/ground reverse, hot/neutral reverse, correct C22.2 No. 160-M1985 / UL 1436 - 4th Edition Certification Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) cCSAus (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6004306 A