Refer to Application Notes
ECONOLINE
DC/DC-Converter
with 3 year Warranty
REC10/M
RoHS
2011/65/EU
6/6
Selection Guide
●10W in 2” x 1” Package
●2kVDC and 3kVDC Isolation Options
●2:1 or 4:1 Input Voltage Range
●Continuous Short Circuit Protection
(power limiting)
●Synchronous Rectification on all Del outputs
●Full SMD internal design
●Remote Control Pin
●Efficiency to 87%
Features
Regulated
Converters
Part Input Output Output Efficiency Max. Cap.
Number Voltage Voltage Current (typ.) Load
(VDC) (VDC) (mA) (%)
REC10-xx3.3S/H*/M 9-18, 18-36, 36-75 3.3 2000 83-84 2200µF
REC10-xx05S/H*/M 9-18, 18-36, 36-75 5 2000 86-87 2200µF
REC10-xx12S/H*/M 9-18, 18-36, 36-75 12 833 85-86 2200µF
REC10-xx15S/H*/M 9-18, 18-36, 36-75 15 667 85-86 2200µF
REC10-xx05D/H*/M 9-18, 18-36, 36-75 ±5 ±1000 82-83 ±1000µF
REC10-xx12D/H*/M 9-18, 18-36, 36-75 ±12 ±416 85-86 ±1000µF
REC10-xx15D/H*/M 9-18, 18-36, 36-75 ±15 ±333 85-86 ±1000µF
REC10-xx3.3SZ/H*/M 9-36, 18-75 3.3 2000 82 2200µF
REC10-xx05SZ/H*/M 9-36, 18-75 5 2000 86 2200µF
REC10-xx12SZ/H*/M 9-36, 18-75 12 833 85 2200µF
REC10-xx15SZ/H*/M 9-36, 18-75 15 667 86 2200µF
REC10-xx05DZ/H*/M 9-36, 18-75 ±5 ±1000 82 ±1000µF
REC10-xx12DZ/H*/M 9-36, 18-75 ±12 ±416 85 ±1000µF
REC10-xx15DZ/H*/M 9-36, 18-75 ±15 ±333 86 ±1000µF
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-75Vin = 48
* Standard is /H2 for 2kVDC isolation,
use /H3 for 3kVDC Isolation
Description
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
The REC10-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with
2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Re-
mote on/off control is standard. The converters can deliver 150% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents.
Input Voltage Range 2:1 or 4:1
Input Filter PI Network
Output Voltage Accuracy (the Output 3.3V is ±1.2% max.) ±1.0% max.
Line Voltage Regulation ±0.3% max.
Load Voltage Regulation Single ±0.5% max.
(25% to 100% full load ) Dual ±1.2% max.
Cross Regulation (100%: 25% to 100% full load ) ±5% max.
Output Ripple and Noise (with 100n output capacitor and 20MHz BW) 100mVp-p max.
Start-up time (Nom. Vin at 100% Load) 25ms typ.
Operating Frequency (Full Load) 300kHz typ.
Efficiency (Nom. Vin at 100% Load) see Selection Guide
Minimum Load 0%
Input Surge Voltage (100ms max.) 12V Input 36VDC
24V Input 50VDC
48V Input 100VDC
continued on next page
10 Watt
2” x 1”
Single &Dual
Output
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
E-224736
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015 www.recom-power.comE-166