Du line I/O-Module for Elevators Type G 2140 55.0 700 (R) Fieldbus Installationbus * * * * * * * 4 push-button inputs 4 PNP- or NPN-transistor outputs Open printed circuit board Bracket for DIN-rail mounting available LED-indications for supply and Dupline(R) carrier DC-supply 3-wire system with Dupline(R) and supply of module and output load through G 3485 0000 700 * Channel coding by GAP 1605 Product Description Ordering Key Only 3-wires needed to connect any number of I/O-units (including the DC-supply for the output load). Installerfriendly mounting, operation and maintenance without requirements for any special tools or programming. Type: Dupline(R) Open PCB I/O-module Number of I/Os I/O-type DC-supply Supply Ordering no. NPN-outputs Ordering no. PNP-outputs 10-30 VDC G 2140 5510 700 G 2140 5520 700 Direct interface to the I/O's of elevator floor stations, lift-car signals and lift controls. The input pulses are prolonged to 0.5 s to ensure transfer of fast pushbutton activations. Due to the small size of the module it can be integrated into most pushbutton panels. G 2140 5520 700 Type Selection Output Specifications G 2140 5510 700 G 2140 5520 700 Outputs Output voltage drop Output voltage 4 NPN-transistors 1.2 V 4 PNP-transistors Current pr. output Max. total load Short circuit protection Built-in protective diodes Off-state leakage current Response time 200 mA 500 mA None Yes 100 A 1 pulse train (136 ms @ 128 ch.) Typ. Vin -2.0 V Vin -2.8 V 200 mA 500 mA None Yes 200 A 1 pulse train (136 ms @ 128 ch.) Input Specifications Supply Specifications Inputs Power supply Rated operational voltage (Vin) Ripple Reverse polarity protection Current consumption Power dissipation Inrush current Transient protection voltage Dielectric voltage Supply - Dupline(R) Supply - Inputs Supply - Outputs Open loop voltage Short circuit current Start peak current Contact resistance Cable length Transmission delay Input OFF - ON Input ON - OFF 4 contacts or NPN-transistor 8.0 VDC 180 A 7 mA 100 3m 20 ms + 1 pulse train 550 ms Specifications are subject to change without notice (29.04.03) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group Overvoltage cat. III (IEC 60664) 10-30 VDC (ripple included) 3V Yes 20 mA 1W 1A 800 V None None None 1 Du line G 2140 55.0 700 (R) Fieldbus General Specifications Power ON delay Indication for Supply ON Dupline(R) carrier Environment Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Weight Installationbus Pin Allocation Typ. 2 s LED, green LED, yellow -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 20 - 80% 15 G (11 ms) 2 G (6 to 55 Hz) Open PCB 74 x 59 mm 4 pcs. of nylon PA6 snap locks are included for mounting the PCB in o 4.8 holes 100 g Terminal Input/Output DUP GND +24 IN +24 OUT I1 I2 I3 I4 O1 O2 O3 O4 Dupline(R) signal Dupline(R) + supply GND Supply IN DC for output loads Input 1 Input 2 Input 3 Input 4 Output 1 Output 2 Output 3 Output 4 Accessories Aluminium bracket for DIN mounting DIN-rail 8047 - bracket FMD 411 Mode of Operation The I/O-units use three wires for the communication with all the other I/O-units of an installation, for the supply of the I/O-units and for the loads connected to the outputs of the units. This implies, that the "common" of the communication signal is identical to the "minus" of the supply. The DC-supply voltage must connect to the system through a G 2196 0000 700, which also performs the channel generator function and the RS485 com- munication link to elevator controller (please refer to the data sheet for G 2196 0000 700 for details). Each I/O-unit has 4 inputs (NPN/contact) and 4 outputs (NPN or PNP). Every input an output is given its individual address with the coding unit GAP 1605 (please refer to the respective data sheet for details). The ON/OFF-signal that is applied to the input of an I/O-unit is associated to the address given to that input. Any output of an I/O-unit that is given the identical address will now follow that input signal and switch its output signal ON or OFF. This means that a signal which is input at one location (for example as an output from the lift controller) may be output wherever required and as many times as required. An input pulse stretcher is used on every input to assure that the changes of input signals (even extremely short ones) are communicated by the system. The output status of all outputs of an I/O-unit may be pre-defined for cases like loss of power and loss of communication. Please refer to the paragraph "Output status setting" of the data sheet for the GAP 1605 to change the default setting (all outputs OFF). Wiring Diagrams 2 Specifications are subject to change without notice (28.09.99) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group