SD-500 500W Single Output DC-DC Converter series SPECIFICATION MODEL OUTPUT SD-500L-12 SD-500L-24 SD-500L-48 SD-500H-12 SD-500H-24 SD-500H-48 DC VOLTAGE 12V 24V 48V 12V 24V 48V RATED CURRENT 40A 21A 10.5A 40A 21A 10.5A CURRENT RANGE 0 ~ 40A 0 ~ 21A 0 ~ 10.5A 0 ~ 40A 0 ~ 21A 0 ~ 10.5A RATED POWER 480W 504W 504W 480W 504W 504W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE 23 ~ 30V 46 ~ 60V 11 ~ 15V 23 ~ 30V 46 ~ 60V VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 500ms, 50ms at full load 89% 90% VOLTAGE RANGE INPUT 11 ~ 15V 72 ~ 144VDC Note.5 19 ~ 72VDC EFFICIENCY (Typ.) DC CURRENT (Typ.) CURRENT (AT NO LOAD) INRUSH CURRENT (Typ.) 86% 24.2A/19VDC 88% 24.8A/24VDC 89% 12A/48VDC 87% 8A/72VDC 6A/96VDC Max. 0.2A/48VDC Max. 0.1A/96VDC 60A/48VDC 60A/96VDC 105 ~ 125% rated output power OVERLOAD Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE REMOTE ON/OFF CONTROL Please refer to function manual FUNCTION Open collector signal low when PSU turns on, max. sink current :10mA OUTPUT OK SIGNAL PROTECTION WORKING TEMP. 20 ~ 90% RH non-condensing TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION 0.02%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60950-1 CB approved by TUV, EAC TP TC 004 approved OTHERS DIMENSION PACKING NOTE 62 ~ 68V -20 ~ +60 (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY EMC IMMUNITY MTBF 30.8 ~ 35.2V -40 ~ +85, 10 ~ 95% RH I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020 Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A, EAC TP TC 020 196.3K hrs min. MIL-HDBK-217F (25) 215*115*50mm (L*W*H) 1.15Kg; 12pcs/14.8Kg/0.92CUFT File Name:SD-500-SPEC 2018-01-12 SD-500 500W Single Output DC-DC Converter Mechanical Specification Case No. 912A series Unit:mm 117.5 32.5 150 27.5 177.5 38.95 7 115 95 5-M3 L=3mm 50.5 2 1 47.7 4-M4 L=5mm 16 8.6 10 CN3 3 32.5 2 1 6 5 50 LED +V ADJ. 10 135 6 5 4 15 215 150 32.5 Air flow direction 50 CL 25 14 max. 6-M4 L=5mm Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent DC Input Terminal Pin No. Assignment Pin No. Assignment 1 DC INPUT V+ 2 DC INPUT V3 FG Pin No. 4,5 6,7 Assignment -V +V Pin No. 1 2 3 Assignment +S -S OUTPUT OK Pin No. 4 5 6 Assignment GND RC RCG Mating Housing Terminal HRS DF11-6DS or equivalent JST SPHD-002T-P0.5 or equivalent Block Diagram BOOST fosc : 65KHz PWM fosc : 110KHz +S ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P POWER SWITCHING BOOST RECTIFIERS & FILTER +V -V -S BOOST CONTROL O.T.P. O.V.P. O.L.P. PWM CONTROL AUX POWER Derating Curve DETECTION CIRCUIT OUTPUT REMOTE CONTROL ON/OFF FAN Static Characteristics 100 100 90 80 only for SD-500L-12 LOAD (%) LOAD (%) 60 80 75 70 40 20 -20 for SD-500L 60 for SD-500H 50 40 0 10 20 30 40 45 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 19 24 36 48 72 96 144 INPUT VOLTAGE (VDC) File Name:SD-500-SPEC 2018-01-12 SD-500 500W Single Output DC-DC Converter series Function Description of CN3 Pin No. Function Description Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to 1 +S minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 2 3 4 5 6 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Open collector signal, reference to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum O/P OK external voltage is 13V. GND RC RCG These pins connect to the negative terminal (-V). Remote ON/OFF Remote ON/OFF ground Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Output on SW Open Output off SW Close Fig. 1.2(B) V=0~0.8Vdc V=4~10Vdc Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source 1K (B)Using external voltage source RC 5V 1K RC V SW RCG RCG 2.Output OK signal "Output OK" is an open collector signal. It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signal ; the other is sending out a voltage signal. 2-1 Sink current : The maximum sink current is 10mA and the maximum external voltage is 13V. 2-2 Voltage signal : Between O/P OK(pin3) and GND(pin4) +Vo +Vo -Vo -Vo +V ADJ. CN3 TB1 Output Status 0 ~ 0.5V ON 12 ~ 13V OFF 1 5 2 6 1 CN3 5 +S O/P OK RC -S GND RCG 2 6 File Name:SD-500-SPEC 2018-01-12 SD-500 500W Single Output DC-DC Converter series 3.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. +Vo +Vo -Vo -Vo +V ADJ. CN3 TB1 1 5 2 6 +S (pin1) LOAD + - -S (pin2) Sense lines should be twisted in pairs 1 CN3 5 +S O/P OK RC -S GND RCG 2 6 File Name:SD-500-SPEC 2018-01-12