JQ
1
ds_61B03_en_jq: 100811D
SPECIFICATIONS
Contact
Expected electrical life (min. operations)
Coil (at 20C 68F)
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
High electrical & mechanical
noise immunity relay JQ RELAYS
Standard type High capacity type
Arrangement 1 Form A, 1 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 100 m
Contact material AgSnO2 type
Rating
(resistive)
Nominal switching
capacity
1a 5 A 125 V AC, 2 A 250 V AC, 5 A 30 V DC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC
1c N.O. 5 A 125 V AC, 2 A 250 V AC, 3 A 30 V AC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC
N.C. 2 A 125 V AC, 1 A 250 V AC, 1 A 30 V DC 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC
Max. switching power 1a 625 VA, 150 W 1,250 VA, 150 W
1c N.O. 625 VA, 90 W 1,250 V AC, 150 W
N.C. 250 VA, 30 W 500 V AC, 30 W
Max. switching voltage 250 V AC, 110 V DC (0.3A)
Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A
Min. switching capacity#1 100 mA, 5 V DC
Expected mechanical life (at 180 cpm)(min. operations) 107
Type Switching capacity No. of operations
Standard type
1a 5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5104
2105
2105
105
1c
N.O. 5 A 125 V AC
2 A 250 V AC
3 A 30 V DC
5104
2105
105
N.C. 2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2105
2105
105
High capacity type
1a 10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5104
5104
105
1c
N.O. 10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5104
5104
105
N.C. 3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2105
2105
105
Nominal operating power 1a: 200 mW 1c: 400 mW
VDE
mm inch
FEATURES
High electrical noise immunity
High switching capacity in a compact
package
High sensitivity: 200 mW (1a),
400 mW (1c)
High surge voltage: 8,000 V between
contacts and coil
UL, CSA, VDE, TÜV, SEMKO
approved
Class B coil insulation type available
About Cd-free contacts
We have introduced cadmium-free type
products to reduce environmentally
hazardous substances. Please replace
parts that contain cadmium with Cd-free
products. Evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
20
.787
10
.394
15.6
.614
JQ
2ds_61B03_en_jq: 100811D
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Measurement at same location as “Initial breakdown voltage” section
*2Detection current: 10 mA
*3Wave is standard shock voltage of 1.2 50s according to JEC-212-1981
*4Excluding contact bounce time
*5Measured conditions
*6Half-wave pulse of sine wave: 11ms; detection time: 10s
*7Half-wave pulse of sine wave: 6ms
*8Detection time: 10s
*9 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
*10When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
Max. operating speed 20 cpm
Initial insulation resistance*1Min. 1,000 M at 500 V DC
Initial breakdown voltage*2Between open contacts 1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
Between contacts and coil 4,000 Vrms for 1 min.
Surge voltage between contact and coil*38,000 V
Operate time*4 (at nominal voltage) Max. 20 ms
Release time*4 (at nominal voltage)(without diode) Max. 10 ms
Temperature rise*5Max. 45C
Shock resistance Functional*6Min. 294 m/s2 {30 G}
Destructive*7Min. 980 m/s2 {100 G}
Vibration resistance Functional*898 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm
Destructive 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm
Conditions for operation, transport and storage*9
(Not freezing and condensing at low temperature) Ambient temp.*10 –40C to +85C –40F to +185F
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
Standard type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70C 158°F
High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70C 158°F
Contact
arrangement
1a: 1 Form A
1: 1 Form C
Nil: Standard
P: High capacity
5, 6, 9, 12, 18, 24, 48* V
Contact capacity
Nil: Class E coil insulation
B: Class B coil insulation
Coil insulation class
F: AgSnO2 type
Contact materialCoil voltage (DC)
UL/CSA, VDE, SEMKO approved type is standard.
* Available only for 1 Form C type
1a P BEx. JQ 12 FV
JQ
3
ds_61B03_en_jq: 100811D
TYPES AND COIL DATA at 20C 68F
DIMENSIONS (mm inch)
Part No. Nominal
voltage, V DC Pick-up
voltage, V DC
(min.)
Drop-out
voltage, V DC
(min.)
Nominal
operating
current, mA
Nominal
operating
power, mW Coil resistance,
(10%) Max. allowable
voltage, V DC
1 Form A
Standard type
JQ1a-5V-F 5 3.75 0.25 40
200
125
180% of
nominal voltage
(at 20C 68°F)
JQ1a-6V-F 6 4.5 0.3 33.3 180
JQ1a-9V-F 9 6.75 0.45 22.2 405
JQ1a-12V-F 12 9 0.6 16.7 720
JQ1a-18V-F 18 13.5 0.9 11.1 1,620
JQ1a-24V-F 24 18 1.2 8.3 2,880
High capacity type
JQ1aP-5V-F 5 4 0.25 40
200
125
130% of
nominal voltage
(at 85C 185°F)
JQ1aP-6V-F 6 4.8 0.3 33.3 180
JQ1aP-9V-F 9 7.2 0.45 22.2 405
JQ1aP-12V-F 12 9.6 0.6 16.7 720
JQ1aP-18V-F 18 14.4 0.9 11.1 1,620
JQ1aP-24V-F 24 19.2 1.2 8.3 2,880
1 Form C
Standard type
JQ1-5V-F 5 3.75 0.25 80
400
62.5
150% of
nominal voltage
(at 20C 68°F)
JQ1-6V-F 6 4.5 0.3 66.7 90
JQ1-9V-F 9 6.75 0.45 44.4 202.5
JQ1-12V-F 12 9 0.6 33.3 360
JQ1-18V-F 18 13.5 0.9 22.2 810
JQ1-24V-F 24 18 1.2 16.7 1,440
JQ1-48V-F 48 36 2.4 8.3 5,760
High capacity type
JQ1P-5V-F 5 4 0.25 80
400
62.5
110% of
nominal voltage
(at 85C 185°F)
JQ1P-6V-F 6 4.8 0.3 66.7 90
JQ1P-9V-F 9 7.2 0.45 44.4 202.5
JQ1P-12V-F 12 9.6 0.6 33.3 360
JQ1P-18V-F 18 14.4 0.9 22.2 810
JQ1P-24V-F 24 19.2 1.2 16.7 1,440
JQ1P-48V-F 48 38.4 2.4 8.3 5,760
Download from our Web site.
CAD Data
CAD Data
CAD Data 1 Form A
1 Form C
Dimension : General tolerance
Max. 1mm .039 inch 0.2 .008
1 to 5mm .039 to .118 inch 0.3 .012
Min. 5mm .118 inch 0.4 .016
20
.787
15.6
.614
4.2
.165
0.4
.016
10.16
.400 7.62
.300 7.62
.300
7.62
.300
10
.394
0.3
.012 0.3
.012
0.5 dia.
.020 dia. 0.8
.031
4.2
.165
0.4
.016
20
.787
15.6
.614
10.16
.400
5.08
.200
2.54
.100 7.62
.300
7.62
.300
0.3
.012 0.3
.012
0.3
.012
0.5 dia.
.020 dia. 0.8
.031
10
.394
Schematic (Bottom view)
1 Form A 1 Form C
Coil
COM N.O.
Coil
COM N.O.
N.C.
PC board pattern (Bottom view)
1 Form A 1FormC
Tolerance: 0.1 .004
4-1.3 dia.
4-.051 dia.
7.62
.300
7.62
.300
10.16
.400
5-1.3 dia.
5-.051 dia.
7.62
.300
7.62
.300
10.16
.400
JQ
4ds_61B03_en_jq: 100811D
REFERENCE DATA
Standard type
Max. switching capacity (1 Form A type) Max. switching capacity (1 Form C type)
AC resistive load (High capacity type)
AC resistive load (Standard type)
1
10 100 277 1,000
10
100
5
Contact voltage, V
Contact current, A
1
10 100 277 1,000
10
100
2
3
5
Contact voltage, V
Contact current, A
AC resistive load
(High capacity type) N.O. side
AC resistive load
(High capacity type)
N.C. side
AC resistive load
(Standard type) N.O. side
AC resistive load
(Standard type)
N.C. side
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1a-12V-F, 25 pcs. 1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1-24V-F, 25 pcs. 2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
Max.
Min.
Min.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
100
10
1102345
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×104
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
100 110 120 130 140 160 190180170150
10
20
30
40
50
0
Coil applied voltage, %V
Temperature rise, C
3 A at 85C
5 A at 85C
3 A at 70C
5 A at 70C
100 110 120 130 140 160150
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, C
3 A at 70C
5 A at 70C
5 A at 85C
3 A at 85C
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1a-24V-F
Contact carrying current: 3 A, 5 A
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A 1Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 3 A)
2Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 5 A)
3Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 3 A)
4Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 5 A)
5Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
JQ
5
ds_61B03_en_jq: 100811D
High capacity type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V-F, 25 pcs. 1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V-F, 25 pcs. 2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
100
10
12046810
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×104
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
100 120 140 160 180
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, C
10 A at 70C
10 A at 85C
5 A at 70C
5 A at 85C
Coil applied voltage, %V
Temperature rise, C
100 110 120 130 140 150 160
10
20
30
40
50
60
70
0
10 A at 70C
10 A at 85C
5 A at 70C
5 A at 85C
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A 1Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 5 A)
2Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130C 266F) (Carrying current: 10 A)
3Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 5 A)
4Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115C 239F) (Carrying current: 10 A)
5Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
JQ
6ds_61B03_en_jq: 100811D
SAFETY STANDARDS
For Cautions for Use, see Relay Technical Information.
Item UL/C-UL (Recognized) CSA (Certified) VDE (Certified) TÜV (Certified) SEMKO (Certified)
File No. Contact rating File No. Contact rating File No. Contact rating File No. Rating File No. Contact rating
Standard type
(5A) 1 Form A E43028 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V
AC
1/6HP 277V AC
LR26550 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V
AC
1/6HP 277V AC
40011435 5A 250V AC
(cos=0.4) B 08 09
13461
252
5A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C E43028 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V
AC
1/6HP 277V AC
LR26550 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V
AC
1/6HP 277V AC
40011435 5A 250V AC
(cos=0.4)
(N.O.)
3A 250V AC
(cos=0.4)
(N.C.)
B 08 09
13461
252
5A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
High capacity
type
(10A) 1 Form A
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
40011435 10A 250V AC
(cos=0.4) B 08 09
13461
252
10A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC
High capacity
type
(10A) 1 Form C
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
40011435 (N.O.)
10A 250V AC
(cos=0.4)
(N.C.)
3A 250V AC
(cos=0.4)
B 08 09
13461
252
10A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC