CANNON KPT / KPSE / KPTC Connectors In Accordance with VG95328 ITT Corporation ITT is a diversified leading manufacturer of highly engineered critical components and customized technology solutions for the energy, transportation and industrial markets. Building on its heritage of innovation, ITT partners with its customers to deliver enduring solutions to the key industries that underpin our modern way of life. Founded in 1920, ITT is headquartered in White Plains, N. Y., with employees in more than 35 countries and sales in a total of approximately 125 countries. The company generated 2012 revenues of $ 2.2 billion. For more information, visit www.itt.com. Our connector portfolio remains the most extensive in the industry, offering a reliable and cost effective range of interconnect solutions with the brands of Cannon, VEAM and BIW Connector Systems. Continuous investment in technology and research & development have enabled ITT to provide new, innovative products and solutions to markets including: 2 www.ittcannon.com lndustrial / lnstrumentation Transportation Defense Vehicles Oil & Gas Automotive Commercial & Military Aerospace Our connector portfolio remains the most extensive in the industry, offering a reliable and cost effective range of interconnect solutions Computer, Telecom & Consumer Electronics www.ittcannon.com 3 Introduction to KPSE /KPT /KPTC ITT Cannon's miniature circular connector series KPT, KPSE and KPTC conform to meet the performance specification to MIL-C-26482 with a positive three point bayonet coupling, five-keyway polarization and high insert arrangement contact density. Purpose Highlights **General purpose solder connectors (KPT) - Our solution for small / prototype quantities using solder type contacts **All connectors conforming to the above mentioned standards are fully intermateable and accept a wide range of interchangeable accessories. **High versatility general purpose versions using crimp or solder contacts (KPTC) - Our commercial version for higher volume production with option for solder contacts **Design modifications can be achieved easily and a lower cost using Cannons KPSE / KPT or KPTC versions **VG95328 versions are based on MIL-C-26482 but comply to ECC directives and offer additional shielded versions **High performance crimp connectors (KPSE) - Our solution for volume production optimized for fast assembly featuring "clip-in" contact & insulator design **KPTC is based on MIL-C-26482 but offers a greater versatility in contacts, backshells and plating options **Military approved versions according to VG95328 or MIL-C-26482 **"Blue Generation" RoHS compliant, 500 hours salt spray and conductive plating is offered next to the standard Nickel, Zinc Cobalt or Cadmium platings. Contact us for detail or your request for a customized solution. The broad product range provides the most complete family of connectors conforming to VG95328 and MIL-C-26482 specifications. Dimensions shown in mm | Specifications and dimensions subject to change 4 www.ittcannon.com Product overview KPT KPSE KPTC Material and Finishes Shell Aluminum alloy Aluminum alloy Aluminum alloy Various RoHS compliant plating options are available like Zinc cobalt, Zinc Nickel and Nickel plus none compliant Cadmium Insulator Polychloroprene Polychloroprene Polychloroprene Grommet and seal Polychloroprene Polychloroprene Polychloroprene Contacts Copper alloy, gold and tin plated Copper alloy, gold and tin plated Copper alloy, hard gold and tin plated Mechanical Data Shell styles 00 - Wall mounting receptacle 07 - Jam nut receptacle 01 - Cable connecting plug 08 - Plug with 90 termination assemblies 02 - Box mounting receptacle B - Thru-bulkhead receptacle (KPT only) 06 - Straight plug Shell size 8 through 24 Polarization / Coupling Five keyways / 3-point bayonet A - General duty E - Grommet seal Service classes F - Grommet seal with strain relief PG - PG gland adapters ME - metric gland adapters According to VG95319 Part 2, Test No. 5.9.2 | For styles A to E and Z1, Z2 and Z3 and gaskets style A only, test pressure 0,2 bar overpressure, test duration 48 h, test temperature 25 3C, connector shall be free of moisture Environmental sealing Operating temperature -55 / +125C Durability 500 mating cycles Vibration 200 m/s at 10 to 2000 Hz Electrical Data Number of contacts 2 through 61 3 through 61 2 through 61 Wire size AWG 16 through 24 12 through 24 0,4 - 2,0 mm Contact termination Solder Crimp Crimp, solder KPT /KPSE /KPTC Contact rating Size Rated current A Test current A Millivolt drop mV 20 16 7,5 13,0 7,5 13,0 Less than 55 Less than 50 Insulation resistance ~ 5000 M Exceptions Test voltage Service rating between the central contact and the housing of the coaxial contact Seal Level Service class Vrms VDC 1 1500 2100 2 2300 3200 1 375 535 2 550 770 21336 m / 70 000 ft. Operating voltage (with scoop proof connectors operating voltages acc. to MIL-C-26482 and VG95328 are permitted) Service class Operating voltage VG95328 MIL-C-26482 1 140 VDC/100 VAC 850 VDC/600 VAC 2 165 VDC/115 VAC 1400 VDC/1000 VAC When the connectors in this catalogue are used for voltages greater than 50 Volts and have touchable conductive shell parts they must be used in accordance with the safety regulations DIN VDE Part 140; IEC 60364-4-41. This regulation basically dictates that the power source should be turned off before any mating and unmating of the connector. This regulation does not provide protection against electrical shock when mating and unmating the connectors in the live condition. Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 5 Table of contents Product overview.................................................. 5 How to use this catalogue..................................... 7 Part number creation............................................ 8 Ordering reference................................................10 Contact arrangements...........................................12 Alternate insert positions.......................................15 Wall mounting receptacles....................................16 Cable connecting plugs.........................................17 Box mounting receptacles.....................................18 Thru-bulkhead receptacles.....................................18 Straight plugs.......................................................19 Jam nut receptacles...............................................21 Right angle plugs..................................................22 Special versions Connectors with grounding continuity..................23 Receptacles with straight solder pins.....................26 Accessories and tooling Panel cutouts........................................................27 Protective caps......................................................28 Dummy receptacle................................................30 Cross reference lists ..............................................31 Tools and accessories ...........................................32 KPSE contact and sealing principle ........................33 Product safety information....................................34 Dimensions shown in mm | Specifications and dimensions subject to change 6 www.ittcannon.com How to use This catalog is split in several sections that help you to ** get a general overview of all product lines (product overview) ** create a product part number step by step (part number creation OR ordering reference) ** get all required detail information (dimensions, product details) ** get all required support products (accessories, tooling) The fastest way to find your product of choice is to follow these steps 1 Select your product using either the "part number creation" or "ordering reference" option 3 Add accessories and tooling as required on the related pages 2 Use the detail pages to better understand the available options and choose the best solution for your needs 4 Use the contact information on the back cover to contact us for further questions or to get advise on where you can purchase our products Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 7 Part number creation plug Follow these steps to design your connector part number. STEP 1 Select shell style (plug) Shell Style Plug Shell Style Plug Shell Style Plug Plug straight Solder KPT06 KPTC6 Crimp KPSE06 Plug straight shielded Solder KPT6-DZ KPTC6-DZ Crimp KPSE6-DZ Plug 90 Solder KPT08 KPTC8 Crimp KPSE08 Class F, 90 Grommet seal with thread and cable clamp Class A, 90 General duty with thread STEP 2 Choose backshell Class A General duty with thread Class F Grommet seal with strain relief Class E add mod. code DN Environmental, grommet seal, heat shrink boot adapter Class PG; ME KPTC only Environmental Class E add Mod. code DZ Environmental, grommet seal, shielded heat shrink boot adapter STEP 3 Choose layout see page 12 -14 for layouts STEP 4 Choose gender P=pin STEP 5 Choose rotation see page 15 for rotation (omit for normal position) STEP 6 Choose modification* see page 11 for modifications (omit if no modification is required) Class E, 90 Grommet seal with thread S=socket * If a modification is used the initial 0` in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial 0` e.g. KPTC6 Design your part number as per above steps KPSE / KPT Examples STEP 1 Shell style STEP 2 Class / Backshell STEP 3 Contact arrangement STEP 4 Contact gender Solder Industrial KPT6 E 20 - 41 P Crimp Industrial KPSE6 E 14 - 12 S KPTC Examples STEP 1 Shell style STEP 2 Class / Backshell STEP 3 Contact arrangement STEP 4 Contact gender Solder Industrial KPTC6 E 20 - 41 P Crimp Industrial KPTC6 PG 14 - 12 S STEP 5 Insulation rotation - DZ - STEP 6 Plating W STEP 5 Insulation rotation C - STEP 6 Mod code (max. 3 codes) D - F42 - A240 - F0 STEP 6 Mod code (max. 3 codes) - MA W - P13,5 - MB Dimensions shown in mm | Specifications and dimensions subject to change 8 www.ittcannon.com Part number creation receptacle Follow these steps to design your connector part number. STEP 1 Select shell style (receptacle) Wall Mount Solder KPT00 KPTC0 Crimp KPSE00 KPTC0 Cable connecting Jam Nut* Solder KPT01 KPTC1 Solder KPT07 KPTC7 Crimp KPSE01 Box Mount* Crimp KPSE07 KPTC7 Solder KPT02 KPTC2 Thru-Bulkhead Crimp KPSE02 KPTC2 KPTB (contacts pre-installed) STEP 2 Choose backshell Class A General duty with thread Class F Grommet seal with strain relief Class E Environmental, grommet seal, no clamp Class E add Mod. code DN Environmental, grommet seal, heat shrink boot adapter STEP 3 Choose layout see page 12 -14 for layouts STEP 4 Choose gender P=pin STEP 5 Choose rotation see page 15 for rotation (omit for normal position) STEP 6 Choose modification** see page 11 for modifications (omit if no modification is required) Class PG or ME Environmental, KPTC only Class E add Mod. code DZ Environmental, grommet seal shielded heat shrink boot adapter S=socket * Shell style 02 (box mount) and 07A (jam nut) doesn`t accept a backshell ** If a modification is used the initial 0` in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial 0` e.g. KPTC6 Design your part number as per above steps STEP 1 Shell style STEP 2 Class / Backshell STEP 3 Contact arrangement STEP 4 Contact gender Solder Industrial KPT02 E 20 - 41 P Crimp Industrial KPSE1 E 14 - 12 S KPSE / KPT Examples KPTC Examples STEP 1 Shell style STEP 2 Class / Backshell STEP 3 Contact arrangement STEP 4 Contact gender Solder Industrial KPTC2 E 20 - 41 P Crimp Industrial KPTC0 PG 14 - 12 S Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 9 STEP 5 Insulation rotation - STEP 6 Plating W STEP 5 Insulation rotation C - D STEP 6 Mod code (max. 3 codes) - F42 - A240 STEP 6 Mod code (max. 3 codes) - MA W - F0 - P13,5 - MB Ordering reference KPT / KPSE / KPTC KP.. 02 E 22 - 36 P W * Series KPSE - Cannon prefix crimp, contacts supplied KPT - Cannon prefix solder, contacts installed KPTC - Cannon prefix commercial version, contacts to be ordered separately Shell type Cannon designation omit 0 in case of a mod code and KPTC 00 - wall mounting receptacle see page 16 01 - cable connecting plug see page 17 02 - box mounting receptacle (class E only), thru-bulkhead recep. see page 18 06 - straight plug see page 19/20 07 - jam nut receptacle see page 21 08 - 90 angle plug see page 22 Class A - general duty with thread E - grommet seal, environmental, no clamp E - grommet seal, in combination with modification DN or DZ F - grommet seal with strain relief PG - endbell for PG glands ME - endbell for metric glands Shell size 8 - 24 Contact arrangement see page 12-14 Contact type P - pin S - socket Alternate insert position W, X, Y and Z (omit for normal position) see page 15 Modification see page 11 * If a modification is used the initial 0` in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial 0` e.g. KPTC6 Dimensions shown in mm | Specifications and dimensions subject to change 10 www.ittcannon.com KPSE/KPT-Modification codes Multiple codes can be used in order of listing below KPSE KPTC-Modification codes KPT Multiple codes can be used in order of listing below Endbell KPTC Plating DN - heat shrink boot adapter, grommet seal DN DN Nickel plating (RoHS compliant) C DZ - shielded, heat shrink boot adapter, grommet seal DZ DZ Zinc Cobalt black plating (RoHS compliant) R F42 - without endbell, grommet and ferrule F42 F42 Zinc Cobalt green plating (RoHS compliant) F Plating (Cadmium with olive drab chromate plating is standard; Alternative platings below) Zinc Nickel plating (RoHS compliant) (not for code DZ) H A232 - Zinc Cobalt, black plating (RoHS compliant) A232 A232 Cadmium with olive drab chromate D A240 - Zinc Nickel plating (RoHS compliant) (not for code DZ) A240 A240 Endbell A233 - Zinc Cobalt, green plating A233 A233 DN - heat shrink boot adapter, grommet seal A34 - Nickel plating (RoHS compliant) A34 A34 DZ - shielded, heat shrink boot adapter, grommet seal DZ F42 - without endbell, grommet and ferrule F42 Contact DN F0 - connector without contacts F0 F0 Endbell for PG glands (KPTC and KPT) EX - PCB solder pin 0,76x7mm (style 02 and 07 only) - EX PG09 - thread for shell size 10 P9 EW - PCB solder pin 0,6x7mm (style 02 and 07 only) - EW PG11 - thread for shell size 12 P11 PG13,5 - thread for shell size14 P13,5 PG16 - thread for shell size 16 P16 PG21 - thread for shell size 18, 20, 22 P21 PG29 - thread for shell size 24 P29 Endbell for metric glands (KPTC and KPT) M12 - thread for shell size 10 M12 M16 - thread for shell size 12 M16 M20 - thread for shell size 14 M20 M25 - thread for shell size 16, 18, 20 M25 M32 - thread for shell size 22, 24 M32 Contact Connector supplied with solder pot contacts installed MA Connector supplied with crimp contacts MB Military approved version VG95328 Specification Shell type see page 31 A - wall mounting receptacle with straight endbell B - wall mounting receptacle with cable clamp C - box mounting receptacle D - jam nut receptacle E - jam nut receptacle with cable clamp J - straight plug with adapter DN K - straight plug with cable clamp M - straight plug, version DZ R - wall mounting receptacle, version DZ S - jam nut receptacle with adapter DN T - jam nut receptacle, version DZ Shell size 8, 10, 12, 14, 16, 18, 20, 22 and 24 Contact arrangements Contact type P - pin see page 12 -14 S - socket Alternate insert position see page 15 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 11 A 18 - 1 S N CONTACT ARRANGEMENTS No. of contacts Contact arrangements Service rating Insulator position Contact size AWG W X Y Z 2 8-2 20 1 58 122 - - 3 8-3 20 1 60 210 - - 3 8-3A 20 1 60 - - - 3 8-33 20 1 90 - - - 4 8-4 20 1 45 - - - 6 10-6 20 1 90 - - - 7 10-7 20 1 90 - - - 6 10-98 20 1 90 180 240 270 3 12-3 16 2 - - 180 - 8 12-8 20 1 90 112 203 292 10 12-10 20 1 60 155 270 295 14 12-14 20 1 60 155 270 295 5 14-5 16 2 40 92 184 273 12 14-12 20 (8) 16 (4) 1 43 90 - - Legend KPT KPSE authorized per MIL-C-26482 authorized per VG95328 Dimensions shown in mm | Specifications and dimensions subject to change 12 www.ittcannon.com CONTACT ARRANGEMENTS No. of contacts Contact arrangements Service rating Insulator position Contact size AWG W X Y Z 15 14-15 20 (14) 16 (1) 1 17 110 155 234 18 14-18 20 1 15 90 180 270 19 14-19 20 1 30 165 315 - 5 14-22 12 (4) 20 (1) 1 - - - - 4 14A4 Coax RG 188 U 1 - - - - 8 16-8 16 2 54 152 180 331 23 16-23 20 (22) 16 (1) 1 158 270 - - 26 16-26 20 1 60 - 275 338 11 18-11 16 2 62 119 241 340 32 18-32 20 2 85 138 222 265 (not for receptacle shell style 02) Legend KPT KPSE authorized per MIL-C-26482 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 13 authorized per VG95328 CONTACT ARRANGEMENTS No. of contacts Contact arrangements Service rating Insulator position Contact size AWG W X Y Z 20A6 12 2 90 180 270 - 16 20-16 16 2 238 316 333 347 24 20-24 20 1 70 145 215 290 39 20-39 20 (37) 16 (2) 1 63 114 252 333 41 20-41 20 1 45 126 225 - 21 22-21 16 2 16 135 175 349 36 22-36 20 1 72 144 216 288 41 22-41 20 (27) 16 (14) 39 135 264 - 55 22-55 20 1 30 142 226 314 61 24-61 20 1 90 180 270 324 5 Note: contacts are 1 grounding pin and 4 standard size 12 pins Legend KPT 1 2 KPSE authorized per MIL-C-26482 authorized per VG95328 Dimensions shown in mm | Specifications and dimensions subject to change 14 www.ittcannon.com ALTERNATE INSERT POSITION The diagram indicates alternate insert positions. The six positions N, V, W, Y, Z differ in degree of rotation for various sizes and arrangements. For the exact degree of rotation, for the list of contact arrangements and for alternate positions available, refer to the table at the right. Shell size No. of contacts W X Y Z 8-2 - 58 122 - - 8-3 - 60 210 - - 3 8-3A - 60 - - - 3 8-33 - 90 - - - 4 8-4 - 45 - - - 6 10-6 - 90 - - - 7 10-7 - 90 - - - 6 10-98 - 90 180 240 270 3 12-3 - - - 180 - 8 12-8 - 90 112 203 292 10 12-10 - 60 155 270 295 14 12-14 - 60 155 270 295 4 14A4 - - - - - 5 14-5 - 40 92 184 273 12 14-12 - 43 90 - - 15 14-15 - 17 110 155 234 18 14-18 - 15 90 180 270 19 14-19 - 30 165 315 - 5 14-22 - - - - - 12 14 8 16-8 - 54 52 180 331 23 16-23 - 158 270 - - 26 16-26 - 60 - 275 338 11 18-11 - 62 119 241 340 32 18-32 - 85 138 222 265 16 5 20A6* - 90 180 270 - 16 20-16 - 238 318 333 347 24 20-24 - 70 145 215 290 39 20-39 - 63 114 252 333 41 20-41 - 45 126 225 - 21 22-21 - 16 135 175 349 36 22-36 - 72 144 216 288 41 22-41 - 39 135 264 - 55 22-55 - 30 142 226 314 61 24-61 - 90 180 270 324 20 24 V 3 10 22 Degree of Rotation 2 8 18 Contact arrangements * This contact arrangement features five contacts size 12. Four standard contacts and one is a first-to-mate contact. Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 15 WALL MOUNTING RECEPTACLES KPT00 / KPSE00 / KPTC0 Shell size OA Q +0,03 - 0,13 Thread Type 2A K M R S OT 0,1 0,15 0,15 max. 0,15 8 12,00 7/16-28UNEF 1,9 11,6 15,1 21,0 3,05 10 15,00 9/16-24UNEF 1,9 11,6 18,3 24,2 3,05 12 19,05 11/16-24UNEF 1,9 11,6 20,6 26,6 3,05 14 22,23 13/16-20UNEF 1,9 11,6 23,0 29,0 3,05 16 25,40 15/16-20UNEF 1,9 11,6 24,6 31,3 3,05 18 28,58 1-1/16-18UNEF 1,9 11,6 27,0 33,7 3,05 20 31,75 1-3/16-18UNEF 2,2 14,25 29,4 36,9 3,05 22 34,93 1-5/16-18UNEF 2,2 14,25 31,8 40,1 3,05 24 38,10 1-7/16-18UNEF 2,2 15,1 34,9 43,3 3,75 VTHD Thread Type 2A O GF min. LF max. O BE max. Backshell options Type A Shell size O DA min. LA max. Type F HF max. Type E LE max. 8 8,5 38,0 1/2-28UNEF 2,9 19,3 56,0 14,2 32,5 10 11,8 38,0 5/8-24UNEF 4,5 20,8 56,0 17,2 32,5 12 15,0 38,0 3/4-20UNEF 7,7 24,4 56,0 20,4 32,5 14 17,9 38,0 7/8-20UNEF 9,3 27,2 56,0 23,4 32,5 16 21,1 38,0 1-20UNEF 12,4 28,7 56,0 26,6 32,5 18 24,1 38,0 1-3/16-18UNEF 15,6 35,3 56,0 29,6 32,5 20 26,5 43,1 1-3/16-18UNEF 15,6 35,3 61,0 32,8 34,5 22 30,4 43,1 1-7/16-18UNEF 18,8 39,9 61,0 36,0 34,5 24 32,8 43,1 1-7/16-18UNEF 20,1 43,2 61,0 39,2 34,5 Mod. DN Shell size O D2 L1 L2 -0,5 max. 0,5 8 15,6 35,0 12,2 10 18,4 35,0 12,2 12 23,7 35,0 12,2 14 24,5 35,0 12,2 16 29,8 37,0 14,5 18 32,0 37,0 14,5 20 36,1 42,0 15,8 22 38,5 42,0 15,8 24 41,6 42,0 14,9 Dimensions shown in mm | Specifications and dimensions subject to change 16 www.ittcannon.com CABLE CONNECTING PLUGS KPT01 / KPSE01 / KPTC1 Shell size OA K M QTHD S OY +0,03 - 0,13 0,1 0,15 Thread Type 2A max. max. 8 12,00 1,9 11,6 7/16-28UNEF 20,6 23,8 10 15,00 1,9 11,6 9/16-24UNEF 23,8 26,9 12 19,05 1,9 11,6 11/16-24UNEF 26,15 29,3 14 22,23 1,9 11,6 13/16-20UNEF 28,5 31,7 16 25,40 1,9 11,6 15/16-20UNEF 30,7 34,1 18 28,58 1,9 11,6 1-1/16-18UNEF 33,3 36,5 20 31,75 2,2 14,25 1-3/16-18UNEF 36,5 39,6 22 34,93 2,2 14,25 1-5/16-18UNEF 39,5 42,8 24 38,10 2,2 15,1 1-7/16-18UNEF 42,8 46,0 Backshell options Type A Shell size Type F Type E O DA LA VTHD O GF HF LF O BE LE min. max. Thread Type 2A min. max. max. max. max. 8 8,5 38,0 1/2-28UNEF 2,9 19,3 56,0 14,2 32,5 10 11,8 38,0 5/8-24UNEF 4,5 20,8 56,0 17,2 32,5 12 15,0 38,0 3/4-20UNEF 7,7 24,4 56,0 20,4 32,5 14 17,9 38,0 7/8-20UNEF 9,3 27,2 56,0 23,4 32,5 16 21,1 38,0 1-20UNEF 12,4 28,7 56,0 26,6 32,5 18 24,1 38,0 1-3/16-18UNEF 15,6 35,3 56,0 29,6 32,5 20 26,5 43,1 1-3/16-18UNEF 15,6 35,3 61,0 32,8 34,5 22 30,4 43,1 1-7/16-18UNEF 18,8 39,9 61,0 36,0 34,5 24 32,8 43,1 1-7/16-18UNEF 20,1 43,2 61,0 39,2 34,5 Mod. DN Shell size O D2 L1 L2 - 0,5 max. 0,5 8 15,6 35,0 12,2 10 18,4 35,0 12,2 12 23,7 35,0 12,2 14 24,5 35,0 12,2 16 29,8 37,0 14,5 18 32,0 37,0 14,5 20 36,1 42,0 15,8 22 38,5 42,0 15,8 24 41,6 42,0 14,9 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 17 BOX MOUNTING RECEPTACLE KPT02 / KPSE02 / KPTC2 KPT / KPSE / KPTC Shell size KPT / KPTC OA L ON K M R S OT +0,03 - 0,13 max. max. 0,1 0,15 0,15 max. 0,15 Z max. 8 12,00 21,1 11,1 1,9 11,6 15,1 21,0 3,05 12,3 10 15,00 21,1 14,3 1,9 11,6 18,3 24,2 3,05 12,3 12 19,05 21,1 17,5 1,9 11,6 20,6 26,6 3,05 12,3 14 22,23 21,1 20,6 1,9 11,6 23,0 29,0 3,05 12,3 16 25,40 21,1 23,8 1,9 11,6 24,6 31,3 3,05 12,3 18 28,58 21,1 27,0 1,9 11,6 27,0 33,7 3,05 12,3 20 31,75 22,7 30,2 2,2 14,25 29,4 36,9 3,05 10,8 22 34,93 22,7 33,4 2,2 14,25 31,8 40,1 3,05 10,8 24 38,10 22,7 36,5 2,2 15,1 34,9 43,3 3,75 10,0 THRU-BULKHEAD RECEPTACLES KPTB Shell size OA K L M T R S OX +0,03 - 0,13 0,1 max. 0,25 max. 0,15 max. 0,15 8 12,00 1,8 28,6 14,5 6,0 15,1 21,0 3,05 10 15,00 1,8 28,6 14,5 6,0 18,3 24,2 3,05 12 19,05 1,8 28,6 14,5 6,0 20,6 26,6 3,05 14 22,23 1,8 28,6 14,5 6,0 23,0 29,0 3,05 16 25,40 1,8 28,6 14,5 6,0 24,6 31,3 3,05 18 28,58 1,8 28,6 14,5 6,0 27,0 33,7 3,05 20 31,75 2,5 31,9 17,7 9,2 29,4 36,9 3,05 22 34,93 2,5 31,9 17,7 9,2 31,8 40,1 3,05 24 38,10 2,5 31,9 17,7 8,0 34,9 43,3 3,75 Dimensions shown in mm | Specifications and dimensions subject to change 18 www.ittcannon.com STRAIGHT PLUGS KPT06 / KPSE06 / KPTC6 Shell size OG QTHD max. Thread Type 2A 7/16-28UNEF 8 19,8 10 23,6 9/16-24UNEF 12 26,5 11/16-24UNEF 14 30,1 13/16-20UNEF 16 33,2 15/16-20UNEF 18 35,4 1-1/16-18UNEF 20 39,0 1-3/16-18UNEF 22 42,1 1-5/16-18UNEF 24 45,2 1-7/16-18UNEF Backshell options Type A Shell size Type F Type E O DA LA VTHD O GF LF HF O BE LE min. max. Thread Type 2A min. max. max. max. max. 8 8,5 42,0 1/2-28UNEF 2,9 56,0 19,3 14,2 32,5 10 11,8 42,0 5/8-24UNEF 4,5 56,0 20,8 17,2 32,5 12 15,0 42,0 3/4-20UNEF 7,7 56,0 24,4 20,4 32,5 14 17,9 42,0 7/8-20UNEF 9,3 56,0 27,2 23,4 32,5 16 21,1 42,0 1-20UNEF 12,4 59,0 28,7 26,6 32,5 18 24,1 42,0 1-3/16-18UNEF 15,6 59,0 35,3 29,6 32,5 20 26,5 45,0 1-3/16-18UNEF 15,6 59,0 35,3 32,8 34,5 22 30,4 45,0 1-7/16-18UNEF 18,8 59,0 39,9 36,0 34,5 24 32,8 45,0 1-7/16-18UNEF 20,1 59,0 43,2 39,2 34,5 Mod. DN Shell size O D2 L1 L2 - 0,5 max. 0,5 8 15,6 35,0 12,2 10 18,4 35,0 12,2 12 23,7 35,0 12,2 14 24,5 35,0 12,2 16 29,8 37,0 14,5 18 32,0 37,0 14,5 20 36,1 42,0 15,8 22 38,5 42,0 15,8 24 41,6 42,0 14,9 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 19 STRAIGHT PLUG KPT6PG / KPTC6PG Shell size OG OB C LPG max. max. min. max. PGTHD 10 23,6 19,0 10,5 58,5 12 26,5 22,5 10,5 58,5 PG 09 PG 11 14 30,1 25,0 10,5 58,5 PG 13,5 PG 16 16 33,2 28,0 10,5 73,0 18 35,4 32,5 11,5 73,0 PG 21 20 39,0 34,5 11,5 76,0 PG 21 22 42,1 38,0 11,5 82,0 PG 21 24 45,2 40,5 11,5 82,0 PG 29 Metric Thread STRAIGHT PLUG KPT6ME / KPTC6ME Shell size OG OB C LME max. max. min. max. 10 23,6 19,0 10,5 58,5 M 12 x 1,5 12 26,5 22,5 10,5 58,5 M 16 x 1,5 14 30,1 25,0 10,5 58,5 M 20 x 1,5 16 33,2 28,0 10,5 73,0 M 25 x 1,5 18 35,4 32,5 11,5 73,0 M 25 x 1,5 20 39,0 34,5 11,5 76,0 M 25 x 1,5 22 42,1 38,0 11,5 82,0 M 32 x 1,5 24 45,2 40,5 11,5 82,0 M 32 x 1,5 Dimensions shown in mm | Specifications and dimensions subject to change 20 www.ittcannon.com JAM NUT RECEPTACLES KPT07 / KPSE07 / KPTC7 Shell size OA F H K M RTHD S T Panel thickness ON +0,03 - 0,13 0,15 0,15 0,25 0,15 Thread Type 2A 0,5 min. max. max. 8 12,00 13,3 19,0 3,2 17,7 9/16-24UNEF 24,0 1,6 3,5 28,0 10 15,00 16,5 22,2 3,2 17,7 11/16-24UNEF 27,0 1,6 3,5 31,0 12 19,05 20,6 27,0 3,2 17,7 7/8-20UNEF 32,0 1,6 3,5 36,0 14 22,23 23,8 30,2 3,2 17,7 1-20UNEF 35,0 1,6 3,5 39,0 16 25,40 26,9 33,3 3,2 17,7 1-1/8-18UNEF 38,5 1,6 3,5 42,0 18 28,58 30,1 36,5 3,2 17,7 1-1/4-18UNEF 41,5 1,6 3,5 45,0 20 31,75 33,3 39,7 4,0 22,5 1-3/8-18UNEF 46,0 1,6 6,5 50,0 22 34,93 36,5 42,9 4,0 22,5 1-1/2-18UNEF 49,5 1,6 6,5 55,0 24 38,10 39,6 46,0 4,0 23,3 1-5/8-18UNEF 52,5 1,6 6,5 57,0 Backshell options Type F Shell size Type E Type DN Type A KPT / KPTC LF O GF HF O BE LE L1 L2 O D2 Z max. max. max. max. max. max. 0,5 max. max. 8 44,9 2,9 19,3 18,2 33,5 43,0 12,2 15,6 7,9 10 44,9 4,5 20,8 21,5 33,5 43,0 12,2 18,4 7,9 12 44,9 7,7 24,4 24,6 33,5 43,0 12,2 23,7 7,9 14 44,9 9,3 27,2 27,8 33,5 43,0 12,2 24,7 7,9 16 48,4 12,4 28,7 31,0 33,5 45,5 14,5 29,8 7,9 18 48,4 15,6 35,3 34,1 33,5 45,5 14,5 32,0 7,9 20 50,3 15,6 35,3 38,1 39,0 52,6 15,8 36,1 4,7 22 50,3 18,8 39,9 41,3 39,0 52,6 15,8 28,5 4,7 24 50,3 20,1 43,2 44,5 39,0 51,6 14,9 41,6 3,8 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 21 RIGHT ANGLE PLUG, 90 KPT08 / KPSE08 / KPTC8 Shell size OG Q max. Thread Type 2A 7/16-28UNEF 8 19,8 10 23,6 9/16-24UNEF 12 26,5 11/16-24UNEF 14 30,1 13/16-20UNEF 16 33,2 15/16-20UNEF 18 35,4 1-1/16-18UNEF 20 39,0 1-3/16-18UNEF 22 42,1 1-5/16-18UNEF 24 45,2 1-7/16-18UNEF Backshell options Type A and E Shell size Type F LAE DAE VTHD L DF LF max. max. Thread Type 2A max. max. max. 8 36,1 20,9 1/2-28UNEF 47,0 31,4 36,1 10 38,3 21,7 5/8-24UNEF 49,5 32,2 38,3 12 40,9 23,3 3/4-20UNEF 53,5 35,4 40,9 14 41,6 24,9 7/8-20UNEF 55,5 38,6 41,6 16 42,5 26,5 1-20UNEF 57,0 40,2 42,5 18 44,7 28,1 1-3/16-18UNEF 62,5 41,8 44,7 20 48,3 29,6 1-3/16-18UNEF 67,0 43,4 48,3 22 52,1 31,7 1-7/16-18UNEF 71,5 47,9 52,1 24 52,1 33,6 1-7/16-18UNEF 74,0 49,9 52,1 Dimensions shown in mm | Specifications and dimensions subject to change 22 www.ittcannon.com VERSIONS WITH GROUNDING CONTINUITY KPT / KPSE / KPTC These connectors are designed to ensure electrical continuity **at the cable shielding level to protect it against radio frequency interferences **at the grounding level (if it is connected to the shielding) The plugs are manufactured with grounding fingers fixed to the front face of the shell. They make contact with the inner side of the receptacle shell. Plug and receptacle feature a special backshell which supports the cable shielding. The connectors are in accordance with the VG95328 specification. RECEPTACLE WITH GROUNDING CONTINUITY (for shielded cable) KPT0E / KPSE0E / KPTC0E... DZ Shell size OA OB OC OD E K L M R S OT +0,03 - 0,13 min. 0,5 max. 1,0 0,1 max. 0,15 0,15 max. 0,15 8 12,00 6,6 16,0 13,3 15,0 1,9 52,0 11,6 15,1 21,0 3,05 10 15,00 9,2 18,0 16,1 15,0 1,9 52,0 11,6 18,3 24,2 3,05 12 19,05 12,2 22,0 20,0 17,0 1,9 52,0 11,6 20,6 26,6 3,05 14 22,23 15,2 25,0 22,2 18,0 1,9 53,0 11,6 23,0 29,0 3,05 16 25,40 18,3 28,0 26,2 18,0 1,9 53,0 11,6 24,6 31,3 3,05 18 28,58 20,0 32,0 28,5 18,0 1,9 53,0 11,6 27,0 33,7 3,05 20 31,75 23,0 34,0 32,5 18,0 2,2 58,0 14,25 29,4 36,9 3,05 22 34,93 26,0 38,0 34,8 18,0 2,2 58,0 14,25 31,7 40,1 3,05 24 38,10 28,8 41,0 37,9 18,0 2,2 58,0 15,1 34,9 43,3 3,75 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 23 CABLE CONNECTING PLUG WITH GROUNDING CONTINUITY (for shielded cable) KPT1E / KPSE1E / KPTC1E ... DZ Shell size OA M OB OC OD E K L S OY +0,03 - 0,13 0,15 min. 0,5 max. 1,0 0,1 max. max. max. 8 12,00 11,6 6,6 16,0 13,3 15,0 1,9 52,0 18,5 21,0 10 15,00 11,6 9,2 18,0 16,1 15,0 1,9 52,0 23,0 24,2 12 19,05 11,6 12,2 22,0 20,0 17,0 1,9 52,0 29,0 26,6 14 22,23 11,6 15,2 25,0 22,2 18,0 1,9 53,0 29,5 29,0 16 25,40 11,6 18,3 28,0 26,2 18,0 1,9 53,0 32,0 31,3 18 28,58 11,6 20,0 32,0 28,5 18,0 1,9 53,0 35,0 33,7 20 31,75 14,25 23,0 34,0 32,5 18,0 2,2 58,0 38,5 36,9 22 34,93 14,25 26,0 38,0 34,8 18,0 2,2 58,0 42,0 40,1 24 38,10 14,25 28,8 41,0 37,9 18,0 2,2 58,0 46,0 43,3 STRAIGHT PLUG WITH GROUNDING CONTINUITY KPT6E / KPSE6E / KPTC6E ... DZ Shell size OB OC OG OD E L S min. +0,5 max. max. 1,0 max. +0,2 8 6,6 16,0 19,1 13,3 15,0 48,0 17,00 10 9,2 18,0 22,0 16,1 15,0 48,0 19,00 12 12,2 22,0 26,2 20,0 17,0 48,0 23,00 14 15,2 25,0 29,4 22,2 18,0 49,0 26,00 16 18,3 28,0 32,8 26,2 18,0 49,0 29,00 18 20,0 32,0 35,4 28,5 18,0 49,0 33,00 20 23,0 34,0 39,0 32,5 18,0 53,0 35,00 22 26,0 38,0 42,1 34,8 18,0 53,0 39,00 24 28,8 41,0 45,2 37,9 18,0 53,0 42,00 Dimensions shown in mm | Specifications and dimensions subject to change 24 www.ittcannon.com JAM NUT RECEPTACLE WITH GROUNDING CONTINUITY (for shielded cable) KPT 7E / KPSE 7E / KPTC ... DZ Shell size OA OB OC OD E L S T min. +0,5 max. max. 1,0 max. 0,25 0,25 8 6,6 16,0 18,2 13,3 15,0 47,0 23,0 19,0 10 9,2 18,0 21,4 16,1 15,0 47,0 27,0 22,2 12 12,2 22,0 24,6 20,0 17,0 49,0 31,7 27,0 14 15,2 25,0 27,8 22,2 18,0 50,0 34,9 30,2 16 18,3 28,0 30,9 26,2 18,0 50,0 38,1 33,3 18 20,0 32,0 34,1 28,5 18,0 50,0 41,3 36,5 20 23,0 34,0 38,1 32,5 18,0 55,0 46,0 39,7 22 26,0 38,0 41,3 34,8 18,0 55,0 49,2 42,9 24 28,8 41,0 44,4 37,9 18,0 55,0 52,3 46,0 ASSEMBLY OF A CONNECTOR WITH A GROUND CONTINUITY BACKSHELL KPT / KPSE / KPTC ... DZ Shell size OC max. 8 6,6 10 9,2 12 12,2 14 15,2 16 18,3 18 20,0 20 23,0 22 26,0 24 28,8 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 25 BOX MOUNTING RECEPTACLE KPT2 / KPTC2 ... EX OR EW Shell size OA +0,03 - 0,13 K 0,1 L M ON R S OT max. 0,15 max. 0,15 max. 0,15 8 12,00 1,9 21,1 11,60 11,1 15,1 21,0 3,05 10 15,00 1,9 21,1 11,60 14,3 18,3 24,2 3,05 12 19,05 1,9 21,1 11,60 17,5 20,6 26,6 3,05 14 22,23 1,9 21,1 11,60 20,6 23,0 29,0 3,05 16 25,40 1,9 21,1 11,60 23,8 24,6 31,3 3,05 18 28,58 1,9 21,1 11,60 27,0 27,0 33,7 3,05 20 31,75 2,2 22,7 14,25 30,2 29,4 36,9 3,05 22 34,93 2,2 22,7 14,25 33,4 31,7 40,1 3,05 24 38,10 2,2 22,7 15,10 36,5 34,9 43,3 3,75 T (Panel Thickness) JAM NUT RECEPTACLES KPT7 / KPTC7 ...EX OR EW Shell size OA F H K M RTHD S +0,03 - 0,13 0,15 0,15 0,25 0,15 Thread Type 2A 0,5 min. max. ON max. 8 12,0 13,3 19,0 3,2 17,7 9/16-24UNEF 24,0 1,6 3,5 28,0 10 15,0 16,5 22,2 3,2 17,7 11/16-24UNEF 27,0 1,6 3,5 31,0 12 19,1 20,6 27,0 3,2 17,7 7/8-20UNEF 32,0 1,6 3,5 36,0 14 22,2 23,8 30,2 3,2 17,7 1-20UNEF 35,0 1,6 3,5 39,0 16 25,4 26,9 33,3 3,2 17,7 1-1/8-18UNEF 38,5 1,6 3,5 42,0 18 28,6 30,1 36,5 3,2 17,7 1-1/4-18UNEF 41,5 1,6 3,5 45,0 20 31,8 33,3 39,7 4,0 22,5 1-3/8-18UNEF 46,0 1,6 6,5 50,0 22 34,9 36,5 42,9 4,0 22,5 1-1/2-18UNEF 49,5 1,6 6,5 55,0 24 38,1 39,6 46,0 4,0 23,3 1-5/8-18UNEF 52,5 1,6 6,5 57,0 Dimensions shown in mm | Specifications and dimensions subject to change 26 www.ittcannon.com PANEL CUTOUTS KPT / KPSE / KPTC BOX MOUNTING RECEPTACLE Shell size For rear mounting For front mounting O D +0,25 / 0 O D +0,25 / 0 R 0,15 8 14,0 12,7 15,1 3,1 10 17,0 16,0 18,3 3,1 12 22,0 19,0 20,6 3,1 14 25,0 22,2 23,0 3,1 16 28,0 25,5 24,6 3,1 18 31,0 28,5 27,0 3,1 20 34,5 31,7 29,4 3,1 22 37,5 35,0 31,8 3,1 24 41,0 38,0 34,9 3,6 PANEL THICKNESS P - Panel thickness Shell size Height of screw head included 8 2,2 10 2,2 12 2,2 14 2,2 16 2,2 18 2,2 20 5,4 22 5,4 24 5,4 JAM NUT RECEPTACLE KPT / KPSE KPT / KPSE O A +0,25 / -0 B +0 / -0,12 8 14,5 13,6 10 17,7 16,8 12 22,7 20,9 14 25,7 24,1 16 28,8 27,2 18 32,0 30,4 20 35,1 33,6 22 38,4 36,8 24 41,5 40,0 Shell size Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 27 O T +0,3 PROTECTIVE CAPS KPT / KPSE / KPTC Material Finishes Protective cap Aluminum alloy A34 Nickel Sash chain Stainless steel A232 Zinc cobalt, black Cord Polyamide A233 Zinc cobalt, green Ring Stainless steel A240 Zinc Nickel plating Clip Aluminum alloy Standard (A66) Olive drab chromate over cadmium Gasket Fluor Silicone End link / rivet Stainless steel, passivated Bayonet pin Stainless steel, passivated HOW TO ORDER KPT80- 10 D- A34 KPTC80- Series Series KPT80 - for plug KPTC80 - for plug KPT81 - for receptacle KPTC81 - for receptacle Shell size Shell size 8 - 24 8 - 24 Termination Termination D - Nylon cord 400 mm C - Nylon cord and endlink 10 C- C Clip and end link attached (not assembled) Modification Crimp tool for end link: M317 (selector position 6) C - sash chain and terminal link C - Nickel plated CB - Nylon cord and terminal link D - Cadmium plated N - chain with ring (KPT81 only) R - Zinc cobalt, black NB - Nylon cord with ring (KPT81 only) F - Zinc cobalt, green H - Zinc nickel plating Modification A34 - Nickel plated (RoHS compliant) A232 - Zinc cobalt, black (RoHS compliant) A233 - Zinc cobalt, green A240 - Zinc nickel plating (RoHS compliant) A66 (without code) - Olive drab chromate over cadmium VG95328 Z2 C 10 VG Specification Style Z1 - for receptacle Z2 - for plug Z3 - for jam nut receptacle Termination A - chain and terminal link C - for Z1 and Z2: Nylon cord 400 mm and end link Clip and end link attached (not mounted) Crimp tool for end link: M317 (selector position 6) C - for Z3: Nylon cord with ring Shell size 8 - 24 Dimensions shown in mm | Specifications and dimensions subject to change 28 www.ittcannon.com PROTECTIVE CAPS KPT / KPSE / KPTC Cap with nylon cord For receptacle KPT81 termination D VG95328 Z1 termination C For plug KPT80 termination D VG95328 Z2 termination C Cap with nylon cord and terminal link For receptacle KPT81 termination C and CB VG95328 Z1 termination A For plug KPT80 termination C and CB VG95328 Z2 termination A Cap with nylon cord and ring For receptacle KPT81 termination N and NB VG95328 Z3 termination C Shell size OA L1 OB L2 H ON max. max. max. max. max. 0,5 8 18,26 19,84 18,0 21,44 76 14,7 10 21,44 19,84 20,3 21,44 76 17,9 12 25,40 19,84 25,1 21,44 89 22,6 14 28,58 19,84 28,2 21,44 89 25,8 16 31,75 19,84 31,5 21,44 89 29,0 18 34,92 19,84 34,5 21,44 89 32,2 20 38,10 21,44 37,8 21,44 101 35,3 22 41,28 21,44 40,9 21,44 101 38,5 24 44,45 22,22 44,2 22,22 101 41,7 Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 29 DUMMY RECEPTACLES KPT/KPSE/KPTC HOW TO ORDER KPT MS 158 3115- 8 A A Series Dummy receptacle Shell size Flange A - Standard Shell size OA K M R S OT +0,03 - 0,13 0,4 0,15 0,15 max. 0,15 *8A 12,00 1,6 12,1 15,1 21,0 3,05 * 10 A 15,00 1,6 12,1 18,3 24,2 3,05 * 12 A 19,05 1,6 12,1 20,6 26,6 3,05 * 14 A 22,23 1,6 12,1 23,0 29,0 3,05 * 16 A 25,40 1,6 12,1 24,6 31,3 3,05 * 18 A 28,58 1,6 12,1 27,0 33,7 3,05 * 20 A 31,75 2,4 14,5 29,4 36,9 3,05 * 22 A 34,93 2,4 14,5 31,8 40,1 3,05 * 24 A 38,10 2,4 15,4 34,9 43,3 3,75 * Add "KPT 15 -" or "MS 3115-" prefixes Dimensions shown in mm | Specifications and dimensions subject to change 30 www.ittcannon.com CROSS REFERENCE LIST KPT / KPSE / VG95328 / MIL-C-26482 Solder ITT Cannon MIL-C-26482 KPT00E MS3110E KPT00F MS3110F Crimp VG95328 ITT Cannon MIL-C-26482 VG95328 KPSE00E MS3120E VG95328A KPSE00F MS3120F VG95328B KPT0E-DN KPSE0E-DN KPT0E-DZ KPSE0E-DZ KPT01A KPSE01A VG95328R KPT01E MS3111E KPSE01E MS3121E KPT01F MS3111F KPSE01F MS3121F KPT1E-DN KPSE1E-DN KPT1E-DZ KPT02E KPSE1E-DZ MS3112E VG95328H KPSE02E KPT06A MS3122E VG95328C KPSE06A KPT06E MS3116E KPSE06E MS3126E KPT06F MS3116F KPSE06F MS3126F VG95328K KPT6E-DN KPSE6E-DN VG95328J KPT6E-DZ KPSE6E-DZ VG95328M KPT07A KPSE07A KPT07E MS3114E KPSE07E MS3124E VG95328D KPT07F MS3114F KPSE07F MS3124F VG95328E KPT7E-DN KPSE7E-DN VG95328S KPT7E-DZ KPSE7E-DZ VG95328T KPT08E KPSE08E KPT08F KPTB KPSE08F MS3119 VG95328P CROSS REFERENCE LIST PROTECTIVE CAPS KPT /VG95328 / MIL-C-26482 Part No. ITT Cannon KPT80 Part No. MIL-C-26482 MS3180 KPT80..C KPT81 Z2...VG95328 MS3181 KPT81..C KPT81..N Part No. VG95328 Z1...VG95328 MS 3181..N Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 31 TOOLS AND ACCESSORIES KPT / KPSE / KPTC TOOLS KPSE / KPTC Tool Hand crimp tool Crimp machine Crimp machine Designation M22520/1-01 WA27F-CE HACS Order reference 995-0001-585 121586-5067 HACS Locator* M22520/1-02 M22520/1-02 - Order reference 995-0001-736 995-0001-736 - Test gage M22520/3-1 M22520/3-1 - Order reference 995-0001-684 995-0001-684 - * for contact sizes 20, 16, 12 KPSE Contact size 20* 20** Insertion tool - M24256A20 Order reference 038894-0018 995-0001-950 Old designation Extraction tool CIT-20-16 MS2425R20 CIT-20-5A MS2425R20 Order reference 995-0001-965 995-0001-965 Extraction TIP 317-7130-000 317-7130-000 16 12 M24256A16 M24256A12 995-0001-951 995-0001-913 CIT-16-1 - MS2425R16 MS2425R12 995-0001-964 995-0001-966 317-7129-000 317-7131-000 Order ref. 121086-3101 121086-0097 Extraction tool CET-KPTC-20 CET-KPTC-16 Extraction TIP CET-KPTC-20-TIP CET-KPTC-16-TIP Order reference 070064-0000 LN - * without insulation support ** with insulation support KPTC Contact size 20 16 Insertion tool CITG-20A CIT-16 Order ref. 12086-3104 121086-3008 Insertion pliers CIT-KPTC-20 CIT-F80-16 Insertion tool - Order reference - Old designation Extraction tool - CET-C6B KPT14A4 Contact type Coaxial CONTACTS KPT / KPSE / KPTC / VG95328 KPSE / VG95328 Contact size Contact type 20 Socket with insulation support Pin with insulation support Socket Pin Contact order reference KPSE version VG95328 version 031-8704-203 031-8704-203 430-8560-006 430-8560-006 031-8704-000 031-8704-000 430-8560-004 430-8560-004 Socket 031-8704-012 Pin Grounding pin 430-8560-016 430-8560-020 16 12 KPTC Contact size 20 Socket Pin 16 Socket Pin Order reference (hard gold plated) 031-8704-508 430-8560-404 031-8704-502 430-8560-406 For shell size 8 and contact arrangements 12-14 only: Contact size Order reference hard gold plated hard silver plated 20 Socket 031-8704-509 031-8704-506 20 Pin 430-8560-411 430-8560-410 KPT14A4 Coaxial WIRE HOLE FILLERS KPSE / KPTC Pin Socket DM 53740-5001 DM 53742-5001 KPSE/KPTC Contact size 20 16 12* Coaxial 14A4* Colour code Red Blue Yellow Yellow MS MS3187A20 MS3187-16A MS3187-12 - Cannon 225-1012-000 225-1011-000 225-0072-000 225-0018-000 * KPSE only GASKETS KPT / KPSE / KPTC KPT / KPSE / KPTC Shell size 8 10 12 14 16 Alu-Flex conductive 075-8543-000 075-8543-001 075-8543-002 075-8543-003 075-8543-004 Chloroprene non conductive 075-8543-010 075-8543-011 075-8543-012 075-8543-013 075-8543-014 Shell size 18 20 22 24 Alu-Flex conductive 075-8543-005 075-8543-006 075-8543-007 075-8543-008 Chloroprene non conductive 075-8543-015 075-8543-016 075-8543-017 075-8543-018 Dimensions shown in mm | Specifications and dimensions subject to change 32 www.ittcannon.com KPSE CONTACT AND SEALING PRINCIPLE **High performance **Crimp termination **Closed entry socket contacts Series KPSE environmental, miniature circular, quick disconnect connectors are designed for the extracting requirements of today's electronic industry. They are intermateable, intermountable and interchangeable with all connectors manufactured according to MIL-C-26482, VG95328 and HE 301. Connectors of Cannon series KPSE have obtained the VDE Expertise No. 63761. 1 Standard MIL-C-26482 or Hardware mates with any connector designed to MIL-C-26482 and VG95328 model 2 Crimp, snap-in contacts are designed to SAE-AS-39029 and can be crimped with the standard M22520/1 crimp tool. Complete moisture sealing is achieved by combining four seals: shell, peripheral, interfacial and wire seals. CLOSED-ENTRY SOCKET CONTACTS eliminate damage from abuse by test probes and help to correct any misaligned pins during engagement. SHELL SEAL is effected when the plug shell pushes against the sealing ring in the receptacle when the connectors are mated. CONTACT INSERTION is accomplished from the rear of the connector. When the contact is fully inserted, the clip tines snap securely behind the contact shoulder. PERIPHERAL SEAL around the edge of the pin insulator is designed so that mating the connector puts tension on the seal and greatly reduces compression set. CONTACT EXTRACTION is accomplished with a frontinserted extraction tool. Pressing the tool plunger pushes the contact out through the rear of the connector. INTERFACIAL SEAL is achieved by the insulator faces meeting when the plug and receptacle are mated. 4 Contact retention RETAINING CLIP: completely encased in a tough plastic wafer to protect the clip from damage PLASTIC WAFER: latest version for easier and faster assembly and disassembly of contacts (used on selected layouts) WIRE SEAL is accomplished by a multiple ripple design, exceeding the wire sealing requirements of MIL-C-26482. 3 5 Monobloc insulator does not leave any access to moisture and avoids interfacial empty space. Dimensions shown in mm | Specifications and dimensions subject to change www.ittcannon.com 33 Positive insert-to-shell mechanical retention with hard plastic wafer firmly locked into a groove in the shell, in addition to a strong adhesive bond between the insert and shell. PRODUCT SAFETY INFORMATION 1. MATERIAL CONTENT AND PHYSICAL FORM Electrical connectors do not usually contain hazardous materials. They contain conducting and non-conducting materials and can be divided into two groups. a) Printed circuit types and low cost audio types which employ all plastic insulators and casings. b) Rugged, Fire Barrier and High Reliability types with metal casings and either natural rubber, synthetic rubber, plastic or glass insulating materials. Contact materials vary with type of connector and also application and are usually manufactured from either: Copper, copper alloys, nickel, alumel, chromel or steel. In special applications, other alloys may be specified. 2. FIRE CHARACTERISTICS AND ELECTRIC SHOCK HAZARD There is no fire hazard when the connector is correctly wired and used within the specified parameters. Incorrect wiring or assembly of the connector or careless use of metal tools or conductive fluids, or transit damage to any of the component parts may cause electric shock or burns. Live circuits must not be broken by separating mated connectors as this may cause arcing, ionization and burning. Heat dissipation is greater at maximum resistance in a circuit. Hot spots may occur when resistance is raised locally by damage, e.g. cracked or deformed contacts, broken strands of wire. Local overheating may also result from the use of the incorrect application tools or from poor quality soldering or slack screw terminals. Overheating may occur if the ratings in the product Data Sheet/Catalog are exceeded and can cause breakdown of insulation and hence electric shock. If heating is allowed to continue it intensifies by further increasing the local resistance through loss of temper of spring contacts, formation of oxide film on contacts and wires and leakage currents through carbonization of insulation and tracking paths. Fire can then result in the presence of combustible materials and this may release noxious fumes. Overheating may not be visually apparent. Burns may result from touching overheated components. 3. HANDLING Care must be taken to avoid damage to any component parts of electrical connectors during installation and use. Although there are normally no sharp edges, care must be taken when handling certain components to avoid injury to fingers. Electrical connectors may be damaged in transit to the customers, and damage may result in creation of hazards. Products should therefore be examined prior to installation/use and rejected if found to be damaged. 4. DISPOSAL Incineration of certain materials may release noxious or even toxic fumes. 5. APPLICATION Connectors with exposed contacts should not be selected for use on the current supply side of an electrical circuit, because an electric shock could result from touching exposed contacts on an unmated connector. Voltages in excess of 30 V ac or 42.5 V DC are potentially hazardous and care should be taken to ensure that such voltages cannot be transmitted in any way to exposed metal parts of the connector body. The connector and wiring should be checked, before making live, to have no damage to metal parts or insulators, no solder blobs, loose strands, conducting lubricants, swarf, or any other undesired conducting particles. Circuit resistance and continuity check should be made to make certain that there are no high resistance joints or spurious conducting paths. Always use the correct application tools as specified in the Data Sheet/Catalog. Do not permit untrained personnel to wire, assemble or tamper with connectors. For operation voltage please see appropriate national regulations. IMPORTANT GENERAL INFORMATION (i) Air and creepage paths/Operating voltage. The admissible operating voltages depend on the individual applications and the valid national and other applicable safety regulations. For this reason the air and creepage path data are only reference values. Observe reduction of air and creepage paths due to PC board and/or harnessing. (ii) Temperature All information given are temperature limits. The operation temperature depends on the individual application. intended to be used in accordance with the specifications in this publication. Any use or application that deviates from the stated operating specifications is not recommended and may be unsafe. No information and data contained in this publication shall be construed to create any liability on the part of Cannon. Any new issue of this publication shall automatically invalidate and supersede any and all previous issues. Product Warranty A limited warranty applies to Cannon products. In general, except for obligations assumed by Cannon under this warranty, Cannon shall not be liable for any loss, damage, cost of repairs, incidental or consequential damages of any kind, whether or not based on express or implied warranty, contract, negligence or strict liability arising in connection with the design, manufacture, sale, use or repair of the products. Product availability, prices and delivery dates are exclusively subject to our respective order confirmation form; the same applies to orders based on development samples delivered. Please refer to www.ittcannon.com (General Terms of Sale) for the complete text of Cannon's applicable Terms and Conditions, including Warranty. This publication is not to be construed as an offer. It is intended merely as an invitation to make an offer. By this publication, Cannon does not assume responsibility or any liability for any patent infringements or other rights of third parties which may result from its use. Reprinting this publication is generally permitted, indicating the source. However, Cannon's prior consent must be obtained in all cases. "Engineered for life" is a registered trademark of ITT Corporation (c)2012. All other trademarks or registered trademarks are property of their respective owners. All data subject to change without notice. This document does not contain technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., App 2401 et. Seq.) (iii) Other important information Cannon continuously endeavors to improve their products. Therefore, Cannon products may deviate from the description, technical data and shape as shown in this catalog and data sheets. ITT's Interconnect Solutions, is a division of ITT Corporation who manufactures the highest quality products available in the marketplace; however these products are 34 www.ittcannon.com Circular / Filter / Hermetic / Fiber Optic Connectors As a world leader in circular, filter, and hermetic connectors, ITT can leverage its design and manufacturing expertise to fit virtually any application. Our expertise includes fast positive mating for a wide range of military applications, as well as numerous sizes and contact configurations for various harsh environments. Our wide variety of fiber optic products include hybrid contacts, multi-channel, rack and panel, and hi-rel assemblies, including MIL and ARINC standard solutions that meet numerous specifications, including NATO and MIL standards. D-Subminiature Connectors Cannon invented D-sub connectors in 1952. Our family of D-Subs now includes combinations of signal, power and RF, as well as severe service sealed connectors. Cannon D-Subs are available with an extensive line of backshells and accessories and are one of the most economical shielded connector solutions available. ITT D-Sub connectors are qualified to the MIL-DTL-24308 specification. Microminiature Connectors Developed first by Cannon in the 1960's, ITT's Interconnect Solutions microminiature connectors offer high performance and reliability with exceptional versatility. Available in rectangular, circular, and strip configurations for countless applications, many of our connectors meet or exceed applicable requirements of the MIL-DTL-83513 specification. Rack and Panel Connectors Initially pioneered by Cannon during the 1930s, ITT's Interconnect Solutions is the world leader in rack and panel connectors, offering unmatched variety of shell configurations and insert arrangements, materials, plating, and contact options. Many of our standard and custom designs meet the stringent requirements of ARINC 600, ARINC 404 (MIL-C-81659), and MIL-DTL-83733 standards. Trident Cannon's Trident Connector System is a versatile range of electrical connectors based on a standard contact design. These contacts are fully interchangeable throughout the Trident Connector System. The connector options include low cost rectangular, rack and panel, industrial grade circulars, harsh environment circulars and shielded circulars. Transportation The ITT's Interconnect Solutions includes sealed circular and rectangular connectors in metal or plastic shells. These configurations include board to cable or cable to cable / bulkhead applications. Both signal and power contacts can be combined in various layouts. All product lines within the Transportation segment offer very low contact resistance providing maximum signal integrity. ITT's Interconnect Solutions is an international manufacturer and supplier of connectors including circular, rectangular, fiber optic, RF, power and high voltage, audio, PMCIA, Compact Flash Card, enclosures, cable assemblies, and application specific custom solutions. The Interconnect Solutions portfolio includes the brands Cannon, VEAM, and BIW Connector Systems. As a worldwide leader in connector technology for nearly a century, ITT offers one of the broadest product offerings, six sigma manufacturing capability, Value Based Product Development with exceptional engineering capability, and an extensive sales, distribution, and customer support network. www.ittcannon.com 35 ITT Interconnect Solutions Cannon, VEAM, BIW Connector Systems Visit our website at www.ittcannon.com Global Design & Manufacturing Customer Support North America Europe & Middle East Asia MEXICO - Cannon, VEAM Av. Libre Comercio s/nentre Calzada Industrial Nuevo Nogales y Calzada del Raquet Club, Parque Industrial Nuevo Nogales phone: +52.631.3110050 fax: +52.631.3110060 FRANCE - Cannon, VEAM 15, Boulevard Robert Thiboust Serris, France 77700 phone: +33.1.60.04.93.93 fax: +33.1.60.04.93.90 CHINA - Cannon, VEAM Tuopandun Industrial Area, Jinda Cheng, Xiner Village, Shajing Town, Boan District, Shenzhen City, Guangdong Province, China 518125 phone: +86.755.2726.7238 fax: +86.755.2726.7515 USA - Cannon 666 East Dyer Road Santa Ana, CA 92705 toll free: +1.800.854.3028 phone: +1.714.557.4700 fax: +1.714.628.2142 USA - BIW Connector Systems 500 Tesconi Circle Santa Rosa, CA 95401 phone: +1.707.523.2300 fax: +1.707.523.3567 USA - VEAM 100 New Wood Road Watertown, CT 06795 phone: +1.860.274.9681 fax: +1.860.274.4963 GERMANY - Cannon, VEAM Cannonstrasse 1 71384 Weinstadt phone: +49.7151.699.0 fax: +49.7151.699.217 ITALY - VEAM Corso Europa 41/43 Lainate (MI), Italy 20020 phone: +39.02938721 fax: +39.0293872300 LEBANON - BIW Connector Systems P.O. Box 199 Jounieh Lebanon phone: +961.9.911.560 fax: +961.9.912.126 UK - Cannon, VEAM Jays Close, Viables Estate Basingstoke, RG22 4BA phone: +44.1256.311200 fax: +44.1256.323356 HONG KONG - Cannon, VEAM Units 2405-6, 24/F, ING Tower 308 Des Voeux Road Central Hong Kong phone: +852.2732.2720 fax: +852.2732.2919 INDIA - Cannon, VEAM ITT Corporation India Pvt Ltd Money Chamber, Unit No. 202 #6, KH Road, Bangalore 560027 phone: +91 22 67843000 fax: +91 22 26783033 JAPAN - Cannon, VEAM 5-11-3, Hibarigaoka, Zama-shi, Kanagawa, Japan 252-0003 phone: +81.462.57.2010 fax: +81.462.57.1680 SINGAPORE - Cannon, VEAM 10 Jalan Kilang #06-01 Singapore 159410 phone: +65.62763693 ext 232 fax: +65.62763685 (c) 2013 ITT Corporation "Engineered for life" and "Cannon" are registered trademarks of ITT Corporation. Specification and other data are based on information available at the time of printing, and are subject to change without notice.