Application Note (R) SM-UART-04L PM2.5 + PM10 Particulate Dust Sensor SM-UART-04L Particulate Dust Sensor is designed for a wide range of air quality applications where fine particle dust needs to be measured. Applications include air quality meters and air purifiers for both residential and light industrial monitoring and control. The optical design leverages laser technology, which allows customers to achieve excellent performance with balanced reliability. SM-UART-04L is an ideal solution for industrial and consumer applications. SM-UART-04L is a PM2.5 laser-based Particulate Dust Sensor that detects dust particle concentration in air by using an optical sensing method. A laser light emitting diode (laser LED) and a photo sensor are optically arranged in the device. The photo sensor detects the reflected laser LED light by dust particles in air. The dust sensor can detect small particles from large house dust, by the pulse pattern of the signal output. Features Applications * Laser Optical Dust * Indoor Air Quality Monitoring - High accuracy * Air Cleaners and Purifiers - Fast response * Air Conditioners and HVAC * PM2.5 Output * Outdoor Dust Monitoring (with additional protection) * PM10 Calculated Output * ROHS and REACH Compliant * UART Series Digital Output * Compact in size * Flexible mounting style * Protected from EMC intrusion by metal case * Wide detection range * Average Time Before Re-calibration: 40,000 hrs Figure 1 : Detection Principle Amphenol Advanced Sensors SM-UART-04L Particulate Dust Sensor Block Diagram Calibration Calibration carried out with cigarette smoke per GB/T1880 Absolute Maximum Ratings Absolute Maximum Ratings Parameter Symbol Rating Unit Supply Voltage Vcc 0 to + 5.5 V Operating Temperature Topr -10 to 50 C Storage Temperature Tstg -30 to 70 C RHopr 0 to 95 % RHstg 0 to 95 % Operating Humidity Storage Humidity (1) (1) 1) Non-condensing Electrical Characteristics Parameter Particle Size Detection Range Resolution Indication Error 1 ~100 ug/m3 (2) 100~999 ug/m3 Symbol Min. Typ. Max. Unit D 0.3 2.5 10 um Dreg 1 -- 999 g/m3 R -- 1 -- g /m3 -- -- +/-10 g /m3 Derr -- -- +/-10 % Warm-Up Time twup (2) -- 5 -- s Response Time trsp (2) -- 1 -- s T -- 40,000 -- hour VCC 4.8 5 5.2 V VCC Ripple -- -- 30 mV -- 60 100 mA Laser Life (Average Time Before Re-Calibration) Supply Voltage Supply Voltage Ripple Current Consumption ICC Output (UART) 1) Non-condensing 2 | Amphenol Advanced Sensors (2) 3.3V 2) Testing at T=25C, RH=40-60% SM-UART-04L Particulate Dust Sensor Connector Sensor Connector: CJT A1276WVA-N-2x5P-H72 Equivalent Connector: Harwin, Inc. M50-3000545; Amphenol FCI 20021311-00010T4LF Pin # Pin Name Description 1 5V Input Supply Voltage 2 5V Input Supply Voltage 3 GND Ground 4 GND Ground 5 RESET Reset Pin @3.3V TTL, Low level reset 6 NC -- 7 RXD UART Receiver @ 3.3V TTL 8 NC -- 9 TXD UART Transceiver @ 3.3V TTL 10 SET/SLEEP Working Mode Pin @ 3.3V TTL Floating or high level for normal working condition. Low level for dormancy mode. Application Circuit SM-UART-04L SM-UART-04L Particulate Dust Sensor Application Note (Rev. B - January, 2019) | 3 SM-UART-04L Particulate Dust Sensor Communication Protocol - UART UART Serial Configuration Baud Rate 9600 bps Data Bits 8 Parity None Stop Bits 1 Communication Protocol - Default Output UART Frame Format Head 1 0x42 Head 2 0x4D H_Length ... L_Length ... H_D1 ... L_D1 ... H_D2 ... L_D2 ... H_D3 ... L_D3 ... H_D4 ... L_D4 ... H_D5 ... L_D5 ... H_D6 ... L_D6 ... H_D7 ... L_D7 ... H_D8 ... L_D8 ... H_D9 ... L_D9 ... H_D10 ... L_D10 ... H_D11 ... L_D11 ... H_D12 ... L_D12 ... H_D13 ... Version number L_D13 ... Error code 0b0ABCDEFG A = 1 Laser error B = 1 Laser alarm C = 1 High temperature alarm D = 1 Low temperature alarm E = 1 Fan error F = 1 Fan speed compensation start G = 1 Fan speed alarm H_CS ... L_CS ... Length = 2 * 13 + 2 (Data+CS) PM1 = H_D1 * 256 + L_D1 ug/m3 (Standard Smoke, Calculated Value PM2.5 = H_D2 * 256 + L_D2 ug/m3 (Standard Smoke, Calibrated Value) PM10 = H_D3 * 256 + L_D3 ug/m3 (Standard Smoke, Calculated Value) PM1 = H_D4 * 256 + L_D4 ug/m3 (Environment, Calculated Value) PM2.5 = H_D5 * 256 + L_D5 ug/m3 (Environment, Calculated Value) PM10 = H_D6 * 256 + L_D6 ug/m3 (Environment, Calculated Value) CS = HEAD1 + HEAD2 + ... + L_D13 * We recommend the customers use PM values with the standard smoke. 4 | Amphenol Advanced Sensors SM-UART-04L Particulate Dust Sensor Response Mode - Command Frame Head 1 Head 2 CMD D1 D2 CRC1 CRC2 0x42 0x4D CMD DATAH DATAL LRCH LRCL CMD DATAH 0xE2 X 0xE1 X 0xE4 X DATAL Description Response X Get reading Same format as above table 0x00 - Ask-answer mode Output 0x42 0x4D 0x00 0x04 0xE1 0x00 0x01 0x74 0x01 - Direct output mode mode switch 0x42 0x4D 0x00 0x04 0xE1 0x01 0x01 0x75 0x00 - Standby mode Standby 0x01 - Working mode control 0x42 0x4D 0x00 0x04 0xE4 0x00 0x01 0x77 Dimensions SM-UART-04L Particulate Dust Sensor Application Note (Rev. B - January, 2019) | 5 SM-UART-04L Particulate Dust Sensor Reliability 1 Drop Drop it unintentionally from 100 cm height down to the hard wooden board three times at random direction 2 High Temp. Storage Leave in the atmosphere 70C for 96 hours 3 Low Temp. Storage Leave in the atmosphere -30C for 72 hours 4 High Temp. Operation Operate it in the atmosphere of 50C for 96 hours 5 Low Temp. Operation Operate it in the atmosphere of -10C for 72 hours Repeat 30 times in the following cycle 6 Temperature Cycle 7 Operating Volt. Range VCC = 4.8V/5.0V/5.2V Verify Indication Error within SPEC (0~1000ug/m3) Slow Decrease & Increase of Supply Voltage Decrease the supply volt. from the minimum supply voltage 4.8V to 0V, then increase it from 0V to 5.2V, applying a change rate in equal steps of not more than 200 mV/ min. Test dust concentration is 250 +/- 50 ug/m3 Short Circuit Protection Connect all pins to the pins next to them for a duration of 60s with power supplied and all other pins remain open. Class C satisfied 8 9 10 Reliability - Operating TA=25C, RH=30~70%, VCC=5V Continuously operate 720h. Verify Indication Error within SPEC (0~1000ug/m3) 11 Reliability - ON/OFF 10s ON/10s OFF, operate for 72h. Verify Indication Error within SPEC (0~1000ug/m3) 12 Salt Spray According to GB/T 2423.17-93, spray 5% NaCl solution in salt mist box at 35C for 24 hours, then clean with water after test Data Consistency 6 | Amphenol Advanced Sensors SM-UART-04L Particulate Dust Sensor Packing Specifications Length (L) Width (W) Height (H) Inner Qty Total Qty Weight 418.2mm 295mm 210mm 5 layer 200 pcs 5kg max Application Notes Grounding The metal case is internally connected to GND. Do not strip the metal case. Maintenance The product is designed to be maintenance free. Do not attempt to disassemble the device. There are no user-servicable parts in the module. Disassembly will invalidate warranty. Electro-Magnetic (EM) Noise Excessive electro-magnetic (EM) noise may degrade sensor performance. Shield sensor from EM noise in application. Vibration Excessive vibration may degrade sensor's performance. Please keep sensor far from vibration in application. Ambient Light Excessive ambient light may degrade sensor performance. Keep sensor far from intense direct light. SM-UART-04L Particulate Dust Sensor Application Note (Rev. B - January, 2019) | 7 SM-UART-04L Particulate Dust Sensor Mounting Orientation Please take sensor mounting orientation into consideration to avoid the influence of adhered dust. The sensor is installed vertically as the best of below: In addition, please avoid any adhesive particle (fur, oil, etc). If particles adhere to optical part, malfunction may occur. Amphenol Advanced Sensors www.telaire.com www.amphenol-sensors.com (c) 2019 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. AAS-916-139B_EN - 02/2019