Rev. 09.18.13
LCM600 Series
1 of 6
Embedded Power for
Business-Critical Continuity
LCM600
600 Watts
Bulk Front End
Special Features
•600Woutputpower
LowCost
•2.4”x4.5”x7.5”
•7.41W/cu-in
•Industrial/Medicalsafety
•-40°Cto70°Cwithderating
•Optional5V@2AHousekeeping
•HighEfficiency:89%typical
•Variablespeed“SmartFans”
•DSPcontrolledfrontend
•Conformalcoatoption
•±20%adjustmentrange
•Marginprogramming
•OR-ingFET
•Terminalblockinputoption
Compliance
•EMIClassB
EN61000Immunity
TotalPower: 600 W
#ofOutputs: Single
Output: 12to60V
Optional5.0Vstandby
Electrical Specifications
Safety
Input
Inputrange: 85-264Vac(Operating)
115/230Vac(Nominal)InputthroughstandardIECconnector/
TERMINALBLOCK
Frequency: 47-440Hz,Nominal50/60
Inputfusing: Internal10Afuses,bothlinesfused
Inrushcurrent: ≤25Apeak,eitherhotorcoldstart
Powerfactor: 0.99typical,meetsEN61000-3-2
Harmonics: MeetsIEC1000-3-2requirements
Inputcurrent: 8ARMSmaxinputcurrent,at100Vac
Holduptime: 20msminimumforMainO/P,atfullratedload
Efficiency: >89%atfullload
Leakagecurrent: <0.3mAat264Vac
ON/OFFpowerswitch: N/A
Powerlinetransient: MOVdirectlyafterthefuse
•UL 60950-1
508/1598/1433
60601-1
•CSA 60950-1
•VDE 60950-1
60601
•China CCC
•CBSchemeReport/Cert
LCM600Q Efficiency Without the 5 Vsb
76.00
78.00
80.00
82.00
84.00
86.00
88.00
90.00
92.00
25 50 75 100
Loading %
Efficiency %
100 Vac
230 Vac
Isolation: PRI-Chassis2000VACBasic
PRI-SEC3000VACReinforced
SEC-Chassis200VDC
Rev. 09.18.13
LCM600 Series
2 of 6
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number* Output Nominal Output
Voltage Set Point
Set Point
Tolerance
Adjustment
Range
Current Output Ripple
P/P
Power
Max.
Combined Line/
Load Regulation
Min Max
LCM600L 12V 12V ±0.5% 9.6-14.4V 0A 52A 120mV 600 W 2%
LCM600N 15V 15V ±0.5% 12.0-19.5V 0A 44A 150mV 600 W 2%
LCM600Q 24V 24V ±0.5% 19.2-28.8V 0A 27A 240mV 600 W 2%
LCM600U 36V 36V ±0.5% 28.8-43.2V 0A 16.7A 240mV 600 W 2%
LCM600W 48V 48V ±0.5% 38.4-57.6V 0A 14A 280mV 600 W 2%
*Note:Add“-T”forterminalblockinsteadofIECinput.
Add”-4”For5V,SB
Operatingtemperature: -40°Cto+70°C,linearderatingto50%from50°Cto70°C
Storagetemperature: -40°Cto+85°C
Humidity: 20to90%,non-condensing.Operating.Conformalcoatoptionavailable
Fannoise: <45dBA,80%loadat30°C“-N”LowNoiseOption<35dBA,80%Loadat30°C
Altitude: Operating-16,404.2feet
Storage-30,000feet
Shock: MIL-STD-810F516.5,ProcedureI,VI.Storage
Vibration: MIL-STD-810F514.5,Cat.4,10.Storage
EnvironmentalSpecifications
Output
Outputrating: Seetable1 85-264Vac
Setpoint: ±0.5% 85-264Vac
Totalregulationrange: Mainoutput±2%
5Vsb±1%
Combinedline/load/transientwhenmeasuredatoutputterminal
Ratedload: 600Wmaximum Deratelinearto50%from50°Cto70°C
Minimumload: Mainoutput@0.0A
5Vsb@0.0A
Nolossofregulation
Outputnoise(PARD): 1%maxp-p
50mVmaxp-p
Mainoutput
5Vsboutput
Measuredwitha0.1µFCeramicand10µFTantalumCapacitoron
anyoutput,20MHz
Outputvoltageovershoot: Noovershoot/undershootoutsidetheregulationbandduringonor
off cycle
Transientresponse: <300µSec 50%loadstep@1A/µs
Steploadvalidbetween10%to100%ofoutputrating
Recoverytimetowithin1%ofsetpointatonsetoftransient
Maxunitsinparallel: Upto10
Shortcircuitprotection: Protected,nodamagetooccur Bounce mode
Remotesense: Compensationupto500mV
Outputisolation: Standard per safety requirements
Forcedloadsharing: Towithin10%ofallsharedoutputs Analogsharingcontrol
Overloadprotection(OCP): 105%to125%
120%to170%
Mainoutput
5Vsboutput
Overvoltageprotection(OVP): 125%to145%
110%to125%
12Voutput
5Vsboutput
Overtempprotection: 10-15°Cabovesafeoperatingarea BothPFCandoutputconvertermonitored
FanFaultProtection: For-Noptiononly.WillshutdownoutputandDC_OK
Rev. 09.18.13
LCM600 Series
3 of 6
Embedded Power for
Business-Critical Continuity
PinAssignment
Signals NameDescription PinNumber(s)
+Vout Power rail SK4
GND PowerGND SK5
Signals NameDescription SK2PinNumber
A2 EEPROMAddress 1
-VPROG ReturnconnectionofexternalsupplyforMarginProgramming 2
A1 EEPROMAddress 3
-Vsense RemoteSenseReturn 4
ISHARE Loadsharevoltage 5
A0 EEPROMAddress 6
SDA1 SerialDataSignal(I2C) 7
+VPROG PositiveconnectionofexternalsupplyforMarginProgramming 8
SCL1 SerialClockSignal(I2C) 9
+Vsense RemoteSensePositive 10
5VSB 5Vstandby 11
GND 5VstandbyReturn 12
5VSB 5Vstandby 13
G_DCOK_C GlobalDCOKCollector 14
GPIOA6 EEPROMWriteProtect 15
G_DCOK_E GlobalDCOKEmitter(GND) 16
GND ReturnGroundforoutputsignalandI2Ccommunication 17
G_ACOK_C GlobalACOKCollector 18
INH_EN TurnOffMainOutput 19
G_ACOK_E GlobalACOKEmitter(GND) 20
Note:MatingconnectorforSK2isLANDWINCI0120P1HD0-LF
LED Indicators
2providedareclearlyvisibleuptoa45degreeoffsetfromverticalwithofficeenvironmentambientlighting.Thestatusisreflectedinthe
indicatorcolor.
The DC_OK LEDisbicolor.ItshalllightgreeniftheDCoutputiswithinspecification,andamberiftheoutputfallsoutofspecification.
The AC_OK LEDisGreeniftheACiswithinspecificationandoffwhenoutofspecification.Note:With5Vstandby,Amberalsoindicates
thatPSUisinstandbymode/outputoff.
Control Signals
AC_OK Opencollector0.5Vmaximumat10mA.Bothemitterandcollectoraccessprovided.
DC_OK Opencollector0.5Vmaximumat10mA.Bothemitterandcollectoraccessprovided.
DC_OKwillde-assertwhenoutputislossduetoOCP,OVP,OTP,orFanFault(for-Noption).
PS_INHIBIT/ENABLE Signal 0.0-0.5Vcontactclosure,outputOFF
PSU Front View (24V & 48V UNITS) Signal Output Signal Connectors (SK2)
SK2MatingConnector:JSTPartNumberPHDR-20VS;
ContactPins:JSTPartNumberSPHD-001T-P0.5
Rev. 09.18.13
LCM600 Series
4 of 6
Embedded Power for
Business-Critical Continuity
MechanicalDrawing-IECInput
Weight:2.84lbs(1.29Kg)
OrderingInformation
LCMXXXY AB C ###
CaseSize InputTermination AcousticNoise OptionCodes HardwareCode
1-PhaseinputwhereXXX=
600=2.4”x4.5”x7.5”,
600W Blank=IECconnector Blank=Standard Blank=NoOptions FactoryAssignedfor
Modiefiedstandards
T=TerminalBlock N=LowNoiseFan 1=ConformalCoat
VoltageCodeY= 4=5VStandby
5=Opt1+4
Code
L 12
N 15
Q 24
U36
W48
NOTE:OPTIONALBARRIERSTRIPOUTPUTTERMINALAVAILABLE
OPTIONALMOLEXTYPECONNECTOROUTPUTAVAILABLE
Rev. 09.18.13
LCM600 Series
5 of 6
Embedded Power for
Business-Critical Continuity
MechanicalDrawing-TerminalBlockInput Weight:2.84lbs(1.29Kg)
Rev. 09.18.13
LCM600 Series
6 of 6
Embedded Power for
Business-Critical Continuity
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
Waterfront Business Park
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonandtheEmersonNetworkPower
logoaretrademarksofEmersonElectric
Co.©2012EmersonElectricCo.Allrights
reserved.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower
Burn-In
100%Burn-inat45°C,at80-90%load.Durationofburn-indeterminedbyQualityAssurance
Procedures
MTBF
ThepowersupplyhasaminimumMTBFof300KhoursusingtheBellcore332,issue6
specification@25°Cand40°C,ambient,atfullload.Withthepowersupplyinstalledinasystemin
a25°Cambientenvironmentandoperatingatfullload,capacitorlifeshallbe10years,minimum
forALLelectrolyticcapacitorscontainedwithinthispowersupply.Thepowersupplyshall
demonstrateaMTBFlevelof>500,000hours.
Quality Assurance
FullQAVtestingshallbeconductedinaccordancewithEmersonNetworkPowerStandardswith
reportsavailableuponrequest.
Warranty
EmersonNetworkPowershallwarrantthepowersupplytobefreeofdefectsinmaterialsand
workmanshipforaminimumperiodofthree yearsfromthedateofshipment,whenoperated
withinspecifications.Thewarrantyshallbefullytransferabletotheendowneroftheequipment
poweredbythesupply.
MiscellaneousSpecifications
Orderkitpartnumber73-788-001forcontrolconnectorinterfacewith.3mwiresattached
Orderkitpartnumber73-788-002forcontrolconnectorinterfacewithunloadedhousingand20pins
Accessories
PIN 20
PIN 2
PIN 19
PIN 1
PIN 3
300 ± 5 mm
PIN 20
PIN 2
PIN 19
PIN 1
PIN 3