Uninsulated
Ferrules insure reliable elec-
trical connections when ter-
minating stranded flexible
wire in terminal blocks, cir-
cuit breakers or other con-
trol devices.
Uninsulated ferrules pre-
vent wire strands from fray-
ing and breaking and are
extremely cost effective.
Their shorter lengths and
uninsulated bodies offer
advantages when making
terminations in printed cir-
cuit board terminal blocks
and in other terminal blocks
with smaller clamps or nar-
row widths.
To ensure efficient ferrule
crimping, always select the
smallest ferrule diameter
that fits the wire and use
only professional crimping
tools. (Please refer to the
ordering pages and the
Crimper Selector Guide on
page 109.)
Tube: tin plated copper
AWG Cat. Stripping Length Ferrule Dimensions mm (in.) Std.
(mm2) Type No. mm (in.) A B (ID) C Pk.*
20 (.50) H0.50/6 2216.0 6.0 (.24) 6.0 (.24) 1.3 (.05) 2.1 (.08) 1000/100
18 (.75) H0.75/6 2217.0 6.0 (.24) 6.0 (.24) 1.5 (.06) 2.3 (.09) 1000/100
18 (.75) H0.75/10 2218.0 10.0 (.39) 10.0 (.39) 1.5 (.06) 2.3 (.09) 1000/100
18 (1.00) H1.00/6 2219.0 6.0 (.24) 6.0 (.24) 1.7 (.07) 2.5 (.10) 1000/100
18 (1.00) H1.00/10 2220.0 10.0(.39) 10.0 (.39) 1.7 (.07) 2.5 (.10) 1000/100
16 (1.50) H1.50/7 2221.0 7.0 (.28) 7.0 (.28) 2.3 (.09) 2.8 (.11) 1000/100
16 (1.50) H1.50/10 2222.0 10.0 (.39) 10.0 (.39) 2.3 (.09) 2.8 (.11) 1000/100
14 (2.50) H2.50/7 2223.0 7.0 (.28) 7.0 (.28) 2.5 (.10) 3.4 (.13) 1000/100
14 (2.50) H2.50/12 2224.0 12.0 (.47) 12.0 (.47) 2.5 (.10) 3.4 (.13) 1000/100
12 (4.00) H4.00/9 2225.0 9.0 (.35) 9.0 (.35) 3.2 (.13) 4.0 (.16) 1000/100
12 (4.00) H4.00/12 2226.0 12.0 (.47) 12.0 (.47) 3.2 (.13) 4.0 (.16) 1000/100
10 (6.00) H6.00/12 2227.0 12.0 (.47) 12.0 (.47) 3.9 (.15) 4.7 (.19) 500/100
10 (6.00) H6.00/15 2388.0 15.0 (.59) 15.0 (.59) 3.9 (.15) 4.7 (.19) 500/100
8 (10.00) H10.00/12 2228.0 12.0 (.47) 12.0 (.47) 4.9 (.19) 5.8 (.23) 500/100
8 (10.00) H10.00/15 2389.0 15.0 (.59) 15.0 (.59) 4.9 (.19) 5.8 (.23) 500/100
8 (10.00) H10.00/18 2229.0 18.0 (.71) 18.0 (.71) 4.9 (.19) 5.8 (.23) 500/100
6 (16.00) H16.00/12 2391.0 12.0 (.47) 12.0 (.47) 6.2 (.24) 7.5 (.30) 500/100
6 (16.00) H16.00/15 2392.0 15.0 (.59) 15.0 (.59) 6.2 (.24) 7.5 (.30) 500/100
6 (16.00) H16.00/18 2393.0 18.0 (.71) 18.0 (.71) 6.2 (.24) 7.5 (.30) 100
4 (25.00) H25.00/15 2394.0 15.0 (.59) 15.0 (.59) 7.7 (.30) 9.5 (.37) 500/100
4 (25.00) H25.00/18 2395.0 18.0 (.71) 18.0 (.71) 7.7 (.30) 9.5 (.37) 100
2 (35.00) H35.00/18 2396.0 18.0 (.71) 18.0 (.71) 8.7 (.34) 11.0 (.43) 100
1 (50.00) H50.00/32 2816.0 32.0 (1.26) 32.0 (1.26) 10.9(.43) 13.0 (.51) 100
2/0 (70.00) H70.00/25 2790.0 25.0 (0.98) 25.0 (.98) 13.3(.52) 15.0(.59) 100
3/0 (95.00) H95.00/32 2791.0 32.0 (1.26) 32.0 (1.26) 15.3(.60) 17.0 (.67) 50
4/0 (120.00) H120.00/32 2792.0 32.0 (1.26) 32.0 (1.26) 17.5(.69) 19.0 (.75) 25
250MCM(150.00) H150.00/32 2793.0 32.0 (1.26) 32.0 (1.26) 19.5(.77) 21.0 (.83) 25
350MCM(185.00) H185.00/32 2815.0 32.0 (1.26) 32.0 (1.26) 21.2(.83) 23.5 (.93) 25
500MCM(240.00) H240.00/40 2815.5 40.0 (1.58) 40.0 (1.58) 23.0(.91) 25.0 (.98) 25
UNINSULATED FERRULES
* Different standard packs are available as shown. To order the desired standard pack, please use the quantity required as a suffix to the cat. no.
Example for 100 standard pack: Type H0.50/6, Cat. No. 2216.0/100
CRIMPER SELECTOR
GUIDE
See page 122.
Altech Corp.®35 Royal Road • Flemington, NJ 08822-6000 Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com120
Ferrules
CSA Std C22.2 No. 65-93 - Wire Connectors
CSA Std C22.2 No. 188-M1983 - Splicing Wire and Cable Connectors
ANSI/UL Std No. 486A - Wire Connectors and Soldering Lugs for Use with Copper Conductors
ANSI/UL Std No. 486C - Splicing Wire Connectors
220672
Tested According To:
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Altech:
2395.0 2227.0 2389.0 2224.0 2226.0 2216.0 2222.0 2393.0 2220.0 2391.0 2223.0 2217.0 2221.0 2228.0
2388.0 2392.0 2229.0 2218.0 2225.0 2394.0 2396.0 2219.0 2815.5