BURNDY
Compression
C-48
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
TYPES Y A-2N,Y A-2TC,
YA-4N
UL LISTED 90°C,
600 V OLT TO 35 KV ELECTRO-TIN
PLATED CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
NO INSPECTION
WINDOW
BEVELED
ENTRY
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA8C2TC14 1.402.33
YA8C2TC14-45 21/45/8.40.81.082.20
YA8C2TC14-90 3 #8 STR. .411.49Y2MR (2)
YA8C2TC14E2 1† .412.45Y8MRB-1 (2) W8CVT (2) W8CVT (2)
YA8C2TC14E2-45 2 #6 SOL 1/43/4.41.81.082.33MY29-3 (2) W8CRT (2) W8CRT (2) U8CRT (1) Red 49 1
YA8C2TC14E2-90 310 .411.62MY29-11 (2) X8CRT (2) X8CRT (2)
YA8C2TC38 1 37/24 .732.89MRC840 (2)
YA8C2TC38-45 23/81.73.81.062.72
YA8C2TC38-90 3.732.05
YA6C2N 1.814.40
YA6C2N-45 21/21-3/4.811.12.124.29
YA6C2N-90 3.813.28
YA6C2TC14 1.452.65
YA6C2TC14-45 21/45/8.451.12.082.45
YA6C2TC14-90 3.451.51
YA6C2TC14E1 1.453.03
YA6C2TC14E1-45 21/41.451.12.082.83
YA6C2TC14E1-90 3.451.88Y1MR (2) W5CVT (2) W5CVT (2)
YA6C2TC14E2 1.452.78Y2MR (2) W5CRT (2) W5CRT (2) U5CRT (2)
YA6C2TC14E2-45 2 #6 AWG - 1/43/4.451.12.082.58MY29-3 (2) X5CRT (2) X5CRT (2) U8CABT (2) Blue 7 1-3/16
YA6C2TC14E2-90 3.451.63MY29-11 (2) X8CART (2) X8CART (2)
YA6C2TC38 1.633.22MRC840 (2)
YA6C2TC38-45 23/81.631.12.062.97
YA6C2TC38-90 3.632.06
YA6C2TC38E2 1.632.97
YA6C2TC38E2-45 23/83/4.631.12.062.72
YA6C2TC38E2-90 3.631.81
YA6C2TC38E6 1.632.99
YA6C2TC38E6-45 23/87/8.631.12.062.75
YA6C2TC38E6-90 3.631.83
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
The MM2conductor size listed here is for Class 2 and Class 5 conductor.
" Available undrilled.Add suffix "U" to catalog number (example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
BURNDY
Compression
C-49
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled.Add suffix "U" to catalog number (example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA5C2N 1 4.43MY29-3 (2) W5CRT (2) X5CRT (2)
YA5C2N-45 25 AWG -1/21-3/4.831.12.124.31MY29-1 (2) W5CVT (2) X5CVT (2) U5CRT (2) Blue 7 1-3/16
YA5C2N-90 3 3.28MRC840 (2) X5CRT (2) W5CRT (2)
Y644M (1)
YA4C2N 1 4.45
YA4C2N-45 21/21-3/4.811.12.124.32
YA4C2N-90 3 3.30
YA4C2TC14 1 2.70
YA4C2TC14-45 21/45/8.501.12.092.51
YA4C2TC14-90 3 1.54W4CVT (2) W4CVT (2) U4CRT (2)
YA4C2TC14E2 14 AWG - 2.83W4CRT (2) W4CRT (2) U6CABT (2) Gray 8 1-3/16
YA4C2TC14E2-45 21/43/4.501.12.092.64X4CRT (2) X4CRT (2)
YA4C2TC14E2-90 3 1.66
YA4C2TC38 1 . 3.26
YA4C2TC38-45 23/81.561.12.083.03
YA4C2TC38-90 3 2.09
YA3C2N 1 4.62
YA3C2N-45 21/21-3/4.811.25.124.44
YA3C2N-90 3 3.32
YA3C2TC14 1 2.87
YA3C2TC14-45 21/45/8.551.25.092.62
YA3C2TC14-90 3 #3 STR 1.55
YA3C2TC14E2 1 2.99Y1MR (4)
YA3C2TC14E2-45 2# 3 AWG251/43/4.551.25.092.75Y2MR (4) W3CRT (2) W3CRT (2) U3CRT (2) White 9 1-5/16
YA3C2TC14E2-90 3 1.68MY29-3 (2)
YA3C2TC38 1 #2 SOL 3.43MY29-11 (2)
YA3C2TC38-45 23/81.581.25.083.16MRC840 (2)
YA3C2TC38-90 3 2.11Y644M (1)
YA3C2TC38E2 1 3.18
YA3C2TC38E2-45 23/83/4.581.25.082.91
YA3C2TC38E2-90 3 1.86
YA2C2N 1 4.64
YA2C2N-45 21/21-3/4.811.25.124.46
YA2C2N-90 3 3.34
YA2C2TC14 1 2.86
YA2C2TC14-45 21/45/8.601.25.112.66
YA2C2TC14-90 3 1.58
YA2C2TC14E2 1 2.98
YA2C2TC14E2-45 21/43/4.601.25.112.78W2CVT (2) W2CVT (2)
YA2C2TC14E2-90 3#2 AWG 35 1.71W2CRT (2) W2CRT (2) U2CRT (2) Brown 10 1-5/16
YA2C2TC38E2 1 3.17X2CRT (2) X2CRT (2)
YA2C2TC38E2-45 23/83/4.601.25.112.97
YA2C2TC38E2-90 3 1.90
YA2C2TC516E2 1 3.05
YA2C2TC516E2-45 2 5/163/4.601.25.112.84
YA2C2TC516E2-90 3 1.77
YA2C2NTC38 1 4.17
YA2C2NTC38-45 23/81-3/4.601.25.113.97
YA2C2NTC38-90 3 2.90
BURNDY
Compression
C-50
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled.Add suffix "U" to catalog number.(Example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA2C2TC38 1 3.42
YA2C2TC38-45 23/81.601.25.113.22Y1MR (4)
YA2C2TC38-90 3 2.14Y2MR (4)
YA2C2TC38E6 1 3.30MY29-3 (2) W2CVT (2) W2CVT (2)
YA2C2TC38E6-45 2 #2 AWG 35 3/87/8.601.25.113.10MY29-11 (2) W2CRT (2) W2CRT (2) U2CRT (2) Brown 10 1-5/16
YA2C2TC38E6-90 3 2.02MRC840 (2) X2CRT (2) X2CRT (2)
YA2C2TC516E2 1 3.05Y644M (1)
YA2C2TC516E2-45 2 5/163/4.601.25.112.84
YA2C2TC516E2-90 3 1.77
YA1C2N 1 4.82
YA1C2N-45 21/21-3/4.811.38.124.58
YA1C2N-90 3 3.36
YA1C2TC14 1 3.03Y1MR (4)
YA1C2TC14-45 21/45/8.681.38.102.76MY29-3 (2) W1CVT (2) W1CVT (2)
YA1C2TC14-90 31 AWG 50 1.60MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2) U1CRT-1 (2) Green 11 1-1/2
YA1C2TC14E2 1 3.15MRC840 (2) X1CRT-1 (2) X1CRT-1 (2) U4CABT (2)
YA1C2TC14E2-45 21/43/4.751.38.102.88Y644M (1)
YA1C2TC14E2-90 3 1.73
YA1C2TC38 1 3.59
YA1C2TC38-45 23/81.681.38.103.32
YA1C2TC38-90 3 2.16
YA252N 1 4.81
YA252N-45 21/21-3/4.811.38.11’ 4.56
YA252N-90 3 3.38
YA252TC14 1 3.05
YA252TC14-45 21/45/8.751.38.122.82
YA252TC14-90 3 1.64
YA252TC14E2 1 3.18
YA252TC14E2-45 21/43/4.751.38.122.94W25VT (4) W25VT (4)
YA252TC14E2-90 31/0 AWG - 1.76W25RT (4) W25RT (4) U25RT (2) Pink 12 1-7/16
YA252TC38 1 3.62X25RT (4) X25RT (4) U2CABT (2)
YA252TC38-45 23/81.751.38.123.38
YA252TC38-90 3 2.20
YA252TC516 1 3.49MY29-3 (2)
YA252TC516-45 2 5/161.751.38.123.26MY29-11 (2)
YA252TC516-90 3 2.08MRC840 (4)
YA252NTC38 1 4.37Y644M (1)
YA252NTC38-45 23/81-3/4.751.38.124.13
YA252NTC38-90 3 2.95
YA262N 1 4.97
YA262N-45 21/21-3/4.831.50.124.69
YA262N-90 3 3.41
YA262TC14 1 . 3.22W26VT (4) W26VT (4)
YA262TC14-45 2 2/0 AWG 70 1/45/8.831.50.122.94W26RT (4) W26RT (4) U26RT (2) Black 13 1-9/16
YA262TC14-90 3 1.66X26RT (4) X26RT (4)
YA262TC14E2 1 . 3.34
YA262TC14E2-45 21/43/4.831.50.123.06
YA262TC14E2-90 3 1.79
BURNDY
Compression
C-51
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled.Add suffix "U" to catalog number (example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA262TC38 1 3.78W26VT (4) W26VT (4)
YA262TC38-45 23/81.831.50.123.50W26RT (4) W26RT (4) U26RT (2) Black 13 1-9/16
YA262TC38-90 3 2.22X26RT (4) X26RT (4)
YA272N 1 5.01
YA272N-45 21/21-3/4.911.50.134.73
YA272N-90 33/0 AWG - 3.44
YA272TC14E2 1 3.38W27VT (4) W27VT (4)
YA272TC14E2-45 21/43/4.911.50.123.10W27RT (4) W27RT (4) U27RT (2)
Orange
14 1-9/16
YA272TC14E2-90 3 1.82X27RT (6) X27RT (6)
YA272TC38 1 3.82
YA272TC38-45 23/81.901.50.123.54MY29-3 (2)
YA272TC38-90 3 2.25MY29-11 (2)
YA282N 1 5.17MRC840 (4)
YA282N-45 21/21-3/41.021.62.144.88Y644M (1)
YA282N-90 3 3.49
YA282TC38 1 3.99
YA282TC38-45 23/811.021.62.143.69W28VT (4) W28VT (4)
YA282TC38-90 34/0 AWG - 2.30W28RT (4) W28RT (4) U28RT (2)
Purple
15
1-11/16
YA282TC14E2 1 3.55X28RT (6) X28RT (6)
YA282TC14E2-45 21/43/41.021.62.143.25
YA282TC14E2-90 3 1.86
YA282NTC38 1 4.74
YA282NTC38-45 23/81-3/41.021.62.144.44
YA282NTC38-90 3 3.05
YA292N 1 5.21
YA292N-45 21/21-3/41.111.62.164.94MY29-3 (2) W29VT (4)
YA292N-90 3250 kcmil - 3.52MY29-11 (2) W29VT (4) W29RT (4) U29RT (2) Yellow 16
1-11/16
YA292TC38 1 4.02Y644M (1) X29RT (8) X29RT (8)
YA292TC38-45 23/811.101.62.163.75
YA292TC38-90 3 2.34
YA302TC38 1 4.45
YA302TC38-45 23/811.202.00.164.07
YA302TC38-90 3300 kcmil 150 2.37W30VT (4) W30VT (4) U30RT (4) White 17 2
YA302N 1 5.64W30RT (4) U28ART (4)
YA302N-45 21/21-3/41.202.00.165.26
YA302N-90 3 3.56
YA312N 1 5.68
YA312N-45 21/21-3/41.292.00.185.31
YA312N-90 3 3.60
YA312TC14E2 1 4.05Y644M (1) W31VT (4) U31RT (4)
YA312TC14E2-45 2 350 kcmil 185 1/43/41.292.00.183.68W31VT (4) Red 18 2-1/16
YA312TC14E2-90 3 1.97W31RT (4) U29ART (4)
YA312TC38 1 4.49
YA312TC38-45 23/811.292.00.184.12
YA312TC38-90 3 2.41
YA322N 1 5.85W32VT (4) U32RT (4)
YA322N-45 2 400 kcmil - 1/21-3/41.382.12.195.47W32VT (4) Blue 19 2-3/16
YA322N-90 3 3.64W32RT (4) U30ART (4)
BURNDY
Compression
C-52
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled.Add suffix "U" to catalog number (example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA322TC38 1 4.66W32VT (4) U32RT (4)
YA322TC38-45 2 450 kcmi - 3/811.382.12.194.28W32VT (4) Blue 19 2-3/16
YA322TC38-90 3 2.46W32RT (4) U30RT (4)
YA332N 1 5.93W33VT (4)
YA332N-45 2 450 kcmi - 1/21-3/41.482.12.215.57W33VT (4) U33RT Gray 326 2-5/16
YA332N-90 3 3.70W33RT (4)
YA342N 1 6.06
YA342N-45 21/21-3/41.522.25.235.72
YA342N-90 3 3.73
YA342TC14E2 1 4.46W34VT (4) U34RT (4)
YA342TC14E2-45 2 500 kcmil 240 1/43/41.552.25.234.09W34VT (4)
Brown
20 2-1/2
YA342TC14E2-90 3 2.10W34RT (4) U31ART (4)
YA342TC38 1 4.90
YA342TC38-45 23/811.552.25.234.53
YA342TC38-90 3 2.54
YA352N 1 6.49
YA352N-45 2 550 kcmil - 1/21-3/41.652.63.256.06- - U35RT (4)
Yellow
21
2-11/16
YA352N-90 3 3.77
YA362N 1 6.59
YA362N-45 21/21-3/41.696.17
YA362N-90 3600 kcmil 300 2.69.273.81--
U36RT (4)
Green
22 2-3/4
YA362TC38 1 5.59U32ART (4)
YA362TC38-45 23/811.742.69.265.17
YA362TC38-90 3 2.81Y644M (1)
YA372N 1 6.74
YA372N-45 2 650 kcmil - 1/21-3/41.802.81.276.29- - U37RT (4)
Orange
23 2-7/8
YA372N-90 3 3.84
YA382N 1 6.77
YA382N-45 21/21-3/41.842.81.276.29
YA382N-90 3700 kcmil - 3.84- - U38RT (4) Pink 400 2-7/8
YA382TC38 1 5.76
YA382TC38-45 23/811.842.81.275.29
YA382TC38-90 3 2.84
YA392N 1 6.87
YA392N-45 21/21-3/41.892.88.276.38
YA392N-90 3 3.87
YA392NT38 1 5.87U39RT (4)
YA392NT38-45 2 750 kcmil - 3/811.632.88.275.38- - P39RT (4) Black 24 2-3/4
YA392NT38-90 3 2.87**
YA392TC38 1 5.87
YA392TC38-45 23/811.912.88.275.38
YA392TC38-90 3 2.87
YA402N 1 6.95
YA402N-45 2 800 kcmil 400 1/21-3/41.952.94.306.50- - P40RT (4)
Orange
25 3
YA402N-90 3 3.91**
YA412N 1 6.96
YA412N-45 2 850 kcmil - 1/21-3/42.012.94.316.52- - - Gold 26 3
YA412N-90 3 3.93
BURNDY
Compression
C-53
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM2conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled.Add suffix "U" to catalog number (example:YA25U).
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instr uctions.
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
T T T
B
B
B
90°
L
45°
LL
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA442N 1 7.14
YA442N-45 21/21-3/42.173.00.336.71
YA442N-90 31000 kcmil 500 4.02Y644M (1) - - P44RT (4)
White
27 3-1/16
YA442TC38 1 6.14**
YA442TC38-45 23/812.193.00.335.71
YA442TC38-90 3 3.02
YA-452N 1 7.44
YA-452N-45 2 1250 kcmil - 1/21-3/42.463.19.387.03- - P45RT (6)
Yellow
29 3-1/4
YA-452N-90 3 4.13**
YA-4532N 1 7.48
YA-4532N-45 2 1300 kcmil - 1/21-3/42.533.19.397.07-- -
Orange
30 2-1/16
YA-4532N-90 3 4.16
YA462N 1 7.55
YA462N-45 2 1500 kcmil - 1/21-3/42.673.19.407.15- - P46RT (6)
Green
31 3-1/4
YA462N-90 3 4.22**
YA472N 1 7.89
YA472N-45 2 1750 kcmil - 1/21-3/42.903.44.427.45- - - Gray 33 3-1/2
YA472N-90 3 4.30
YA482N 1 7.98
YA482N-45 2 2000 kcmil - 1/21-3/43.103.44.467.60-- -
Brown
34 3-1/2
YA482N-90 3 4.40