SPEC Pak TM Sealed Power For Environmental Connections Marine | Machine Tool Wind Power | | Lighting | Transportation Industrial Automation | Motor | | Pumps Solar Power | | Ground Support Harsh Environments (R) Anderson Power Products -1www.andersonpower.com (R) Rugged and Sealed (IP68) Plugs and Receptacles For Use with APP(R) Powerpole(R) Signal, Power & Ground Contacts & Housings The SPEC PakTM High Power uses rugged and environmentally sealed (IP68) shells to protect APP(R) Powerpole(R) contacts and housings. Customer configured SPEC PakTM High Power Connectors are capable of up to 260 amps and may be used anywhere a rugged and/or waterproof high power, signal and ground interconnect solution is required. The SPEC PakTM High Power shell accepts 75 to 180 amp Powerpole(R) contacts and up to 8 auxiliary contacts. The wide range of Powerpole(R) housing colors and contact sizes, coupled with the available Powerpole(R) insert holders, offers the user a wide array of design options. Wire sizes which can accommodate a range from 24 to 3/0 AWG (0.25 to 85.0 mm). SPEC PakTM High Power is highly configurable with thousands of design options in a single interconnect. 1 2 4 3 8 5 5 6 7 5 Powerpole(R) Insert Arrangement H02 H03 1 - Chemical & UV Resistant Ruggedized Shells * Wire to wire configurations * Wire to Panel configurations 2 - Stainless Steel Latches (securing plug to receptacle) 3 - IP68 Interfacial Sealing O-Ring 4 - Auxiliary Contacts (up to 8) 5 - Powerpole(R) Insert Holders (user configurable) * H02 Arrangement - up to two PP180 & 8 auxiliaries * H03 Arrangement - up to three PP120 & 8 auxiliaries * H06 Arrangement - up to six PP75 & 8 auxiliaries -2- www.andersonpower.com H06 6 - Power Contacts (up to 260 amps with 3/0 AWG) 7- Color Coded Powerpole(R) Housings Match Wire Colors 8 - Industry Standard Sealing (IP68) Components * PG Gland Compatible - Size 36 and 42 * Multi-hole Glands For Use With Discrete Wires * Single Hole Glands For Use With Jacketed Cable Specifications High Power SPEC PakTM Shell / Components Electrical UL Voltage Rating (AC/DC) Dielectric Withstanding Voltage (AC) Operating Temperature (C ) (F ) Flammability Rating of SPEC PakTM Shells UV Rating (equivalent) 600 3000 -40 to 105 * -40 to 221 UL94 V-0 UL746C F1 Inline Receptacle Latch Mechanical Shell/Latch Mating Cycles Average Connect/Disconnect (lbf) (N) IP Rating UL50 Sec. 36 Sealing Requirement Crush Test per EIA-364-40B Drop Test per UL50E Plug 1,500 Min. 28 125 IP68 Pass Pass Pass PG Gland Material SPEC PakTM - Receptacle, Plug & Holders Latch Latch Retainer Holder Mount Hardware PBT Stainless Steel Stainless Steel Nickel Plated Steel Mated Pair High Power Plug To Inline Receptacle Powerpole(R) Contacts PP180 PP120 PP75 PowerMod(R) UL Current Rating (Amperes) ** CSA (30C Rise) (Amperes) ** Voltage Rating (AC/DC) Contact Barrel Wire Size (AWG) (mm) Average Contact Resistance (milliohm) Contact Retention Force (lbf) (N) Operating Temperature (C) (F) Flammability Rating Contact Materials Contact Plating 260 140 600 3/0 to 6 85 to 13.3 0.10 170 756 -20 to 105 * -4 to 221 UL94 V-0 Copper Silver 190 100 600 1/0 to 6 53.5 to 13.3 0.14 100 445 -20 to 105 * -4 to 221 UL94 V-0 Copper Silver 70 40 600 6 to 12 13.3 to 3.3 0.20 50 222 -20 to 105 * -4 to 221 UL94 V-0 Copper Silver 5 5 600 12 to 24 4.0 3.00 8 36 -20 to 105 * -4 to 221 UL94 V-0 Copper Alloy Gold over Nickel 10,000 20 10,000 8 10,000 5 (Low Detent) 7 (High Detent) 10,000 10 oz. (3N) Average Polycarbonate Polycarbonate Polycarbonate PBT Mechanical Mating Cycles - no load Average Connect/Disconnect (lbf) Material Powerpole(R) Housing Material NOTE: -40 to 120 C (-40 to 248 F) can be achieved by using APP Chemical Resistant Powerpole(R) housing. Contact factory for more information. Based on Panel Mount Receptacle to Plug configuration. * ** 1. Agency approvals - TUV Pending / Patents & Patents Pending www.andersonpower.com -3- Part Number Configurator PART NUMBER PLAN SPEC PakTM Series Shell Color Shell Style (1 Fixed Character) (1 Character) (1 Character) S K 2 S = SPEC PakTM Series K = Black 1 = Inline Receptacle 2 = Panel Mount Receptacle 6 = Straight Plug 9 = Environmental Receptacle Cover 9P = Environmental Plug Cover PLUG KIT Dash - PANEL MOUNT RECEPTACLE KIT Panel Mount Receptacle Gasket Powerpole(R) Holder Set Plug Shell Holder Retaining Screws Powerpole(R) Holder Set Shell Size Insert Arrangement (mm) (3 Characters) 095 095 = 095mm Panel Mount Receptacle Shell A95 = 095mm Shell, PG 36 B95 = 095mm Shell, PG 42 (3 Characters) H02 Detailed Information Is Available On: H02 = PP180, 2 Pole .................... Page 7 H03 = PP120 Housing, 3 Pole ...... Page 8 H06 = PP75, 6 Pole ...................... Page 9 INLINE RECEPTACLE KIT COVER KIT IP68 Sealing Plug Cover Powerpole(R) Holder Set Lanyard Panel Mount Receptacle Shell With Latches IP68 Sealing Receptacle Cover Inline Receptacle Shell With Latches Holder Retaining Screws Holder Retaining Screws Ordering Information Ordering Information Ordering Information Ordering Information Part Number & Description Part Number & Description Part Number & Description Part Number & Description - Inline Receptacle Kit, PG 36 compatible shell with, 2 pole PP180 holder - Receptacle Cover Kit with lanyard SK6-A95H02 SK2-095H02 SK6-A95H03 SK2-095H03 SK6-A95H06 SK2-095H06 - Plug Kit, PG 36 compatible shell with 2 pole PP180 holder - Plug Kit, PG 36 compatible shell with 3 pole PP120 holder - Plug Kit, PG 36 compatible shell with 6 pole PP75 holder - Panel Mount Receptacle Kit with 2 pole PP180 holder - Panel Mount Receptacle Kit with 3 pole PP120 holder - Panel Mount Receptacle Kit with 6 pole PP75 holder SK6-B95H02 - Plug Kit, PG 42 compatible shell with 2 pole PP180 holder SK6-B95H03 - Plug Kit, PG 42 compatible shell with 3 pole PP120 holder SK6-B95H06 - Plug Kit, PG 42 compatible shell with 6 pole PP75 holder NOTE: - Panel Mount Receptacle mounting hardware (8 each #10 or M5 screw) not included - Recommended torque for mounting hardware is 15 to 20 in-lbf (1.7 to 2.2 N-m) -4- www.andersonpower.com SK1-A95H02 SK1-A95H03 - Inline Receptacle Kit, PG 36 compatible shell with, 3 pole PP120 holder SK9-095 SK9P-095 - Plug Cover Kit with lanyard SK1-A95H06 Component Replacement Parts SK1-B95H02 Part Number & Description - Inline Receptacle Kit, PG 36 compatible shell with, 6 pole PP75 holder - Inline Receptacle Kit, PG 42 compatible shell with, 2 pole PP180 holder SK1-B95H03 - Inline Receptacle Kit, PG 42 compatible shell with, 3 pole PP120 holder SK1-B95H06 - Inline Receptacle Kit, PG 42 compatible shell with, 6 pole PP75 holder H1120P41 - #8 x 5/8 screw - Bulk Packaged PART NUMBER PLAN Housing Arrangement Wire Protection See page 6 (4 Characters) PS 00 = None PS = Plastic Short PM = Plastic Multi-hole Dash 00 0 Dash 00 APP Content (3 Characters) - A01 00 = None 00 - 99 = Various Gland Type 0 = Custom Configuration A = AC Single Phase B = AC 3 Phase, 3 Wire E = AC 3 Phase, 4 wire F = AC 3 phase, 5 wire G = DC 2 Circuit, 6 wire R = DC 1 Circuit, 2 Wire Z = All Black Part Numbering Notes: - Contact For more information see pages 7 thru 9 (1 Character) (2 Characters) Custom Configuration Insert Arrangement H03 H06 H06 H06 H06 H02, H03 H02, H03 Contact Code 00 11 12 13 14 15 16 Wire Size Contact AWG (mm) Custom Configuration - Use Next Section 5900 #6 13.3 5952 #8 8.4 5915 #10 to 12 5.3 to 3.3 5900 with Auxiliary #6 13.3 5952 with Auxiliary #8 8.4 5915 with Auxiliary #10 to 12 5.3 to 3.3 Available in Insert Arrangement H06 H06 H06 H06 H06 H06 20 21 22 23 24 25 26 27 28 29 1323G2 1/0 1323G1 #1 1319 #2 1319G4 #4 1319G6 #6 1323G2 with Auxiliary 1/0 1323G1 with Auxiliary #1 1319 with Auxiliary #2 1319G4 with Auxiliary #4 1319G6 with Auxiliary #6 53.5 42.4 33.6 21.2 13.3 53.5 42.4 33.6 21.2 13.3 H03 H03 H03 H03 H03 H03 H03 H03 H03 H03 80 81 82 83 84 85 86 87 88 89 90 91 92 93 1328G2 3/0 1328G1 2/0 1382 1/0 1347 #1 1383 #2 1384 #4 1348 #6 1328G2 with Auxiliary 3/0 1328G1 with Auxiliary 2/0 1382 with Auxiliary 1/0 1347 with Auxiliary #1 1383 with Auxiliary #2 1384 with Auxiliary #4 1348 with Auxiliary #6 85.0 67.4 53.5 42.4 33.6 21.2 13.3 85.0 67.4 53.5 42.4 33.6 21.2 13.3 H02 H02 H02 H02 H02 H02 H02 H02 H02 H02 H02 H02 H02 H02 1) To order SPEC PakTM Shell Kits only (no internal Powerpole(R) housings or contacts), use part numbering on page 4 only. Plug Shell Kit Example: SK6-A95H02 or SK6-B95H02. Powerpole(R) housings, contacts and wire protection may be ordered separately, see pages 6 thru 9 for information. 2) To order customer configured SPEC PakTM connectors (including internal Powerpole(R) housings and contacts) use Part Number Plan across the top of pages 4 and 5. Customer Configured SPEC PakTM Plug Connector Example: SK6-A95H03PS04-A22. 3) To order a custom configuration which is not listed on page 7 thru 9, use APP custom part number configurator on the APP(R) website, www.andersonpower.com or contact factory. NOTE: 1. Custom configurations may not be UL Recognized. 2. Contact code designation #14 to 16, #25 to 29 and #87 to 93 use 4 each of part number PM1612S30 (Pins) & 4 each of part number PM16S12S32 (Sockets) as signal. www.andersonpower.com -5- Wire Protection - PG Gland SPECIFICATIONS Mechanical Material Shell Gasket Color Torque Requirements Operating Temp IP Rating UV Rating Thread Type Nylon PA 66 (UL94 V-2) EPDM Black -40C to 105C (-40F to 221F) IP68 Equivalent to UL746C F1 PG Cable Gland Body to Plug Housing - Hand tighten until snug, tighten additional 1/8 - 1/4 turn with wrench Sealing Nut to Cable - Hand tighten until snug, tighten additional 1/2 - 3/4 turn with wrench STRAIGHT PLASTIC SHORT THREAD TYPE - STD PACK 10 / UL LISTED C1 Lock Nut Washer C2 Body Seal Sealing Nut APP(R) P/N PS1P36-26X PS1P36-32X Wire Protection Designation (4 Characters) PS04 PS05 PG Gland Size 36 36 Number Of Holes 1 1 Cable Range Wire Outer Dia. mm (in) 26.5 - 21.0 (1.04 - 0.83) 32.0 - 24.0 (1.26 - 0.94) Thread O.D. C1 mm (in) 47 (1.85) 47 (1.85) Panel Mounting Hole mm (in) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) Thread Length C2 mm (in) 15 (0.59) 15 (0.59) Wrench Size Lock Nut (mm) 57 57 Wrench Size Sealing Nut (mm) 52 52 PL1P42-19X PS1P42-32X PS1P42-41X PS01 PS02 PS03 42 42 42 1 1 1 19.5 - 16.0 (0.77 - 0.63) 32.0 - 26.0 (1.26 - 0.79) 41.0 - 31.0 (1.61 - 1.22) 54 (2.13) 54 (2.13) 54 (2.13) 54 - 54.4 (2.13 - 2.14) 54 - 54.4 (2.13 - 2.14) 54 - 54.4 (2.13 - 2.14) 15.5 (0.61) 15.5 (0.61) 15.5 (0.61) 64 64 64 62 62 62 STRAIGHT PLASTIC MULTI-HOLE TYPE - STD PACK 10 / NOT UL LISTED C1 Lock Nut Washer C2 Body Seal Claw Sealing Nut Wire Protection Designation PG Gland Number Cable Range Wire Outer Thread O.D. C1 Panel Mounting Thread Length Wrench Wrench Size Lock Size Sealing PS2P36-13X PS2P36-9X PS3P36-7X PS3P36-10X PS4P36-12X PS5P36-8X (4 Characters) PM21 PM22 PM31 PM32 PM41 PM51 Size 36 36 36 36 36 36 Of Holes 2 2 3 3 4 5 Dia. mm (in) 13.0 - 11.0 (0.51 - 0.43) 9.0 - 7.0 (0.35 - 0.28) 7.8 - 6.5 (0.31 - 0.26) 10 - 7.7 (0.39 - 0.30) 12.0 - 10.0 (0.48 - 0.39) 8.3 - 6.5 (0.33 - 0.26) mm (in) 47 (1.85) 47 (1.85) 47 (1.85) 47 (1.85) 47 (1.85) 47 (1.85) Hole mm (in) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) 47 - 47.4 (1.85 - 1.67) C2 mm (in) 15 (0.59) 15 (0.59) 15 (0.59) 15 (0.59) 15 (0.59) 15 (0.59) Nut (mm) 57 57 57 57 57 57 Nut (mm) 52 52 52 52 52 52 PL4P42-10X PL6P42-7X PL8P42-7X PM46 PM66 PM86 42 42 42 4 6 8 10.5 - 8.5 (0.41 - 0.33) 7.0 - 5.0 (0.28 - 0.20) 7.0 - 5.7 (0.28 - 0.22) 54 (2.13) 54 (2.13) 54 (2.13) 54 - 54.4 (2.13 - 2.14) 54 - 54.4 (2.13 - 2.14) 54 - 54.4 (2.13 - 2.14) 15.5 (0.61) 15.5 (0.61) 15.5 (0.61) 64 64 64 62 62 62 APP(R) P/N NOTE: 1. Other PG Gland configurations and specifications are available, please contact the factory. 2. Only UL listed cable glands are UL recognized components when used with SPEC PakTM connector(s). 3. Shading indicates stock item. -6- www.andersonpower.com H02 Insert Arrangement Configured with up to 2 PP180 Contacts (up to 260 amps) Standard & Custom Configuration Options POWERPOLE(R) INSERT HOLDER HOUSING ARRANGEMENT 0 Custom Configuration DC 1 Circuit, 2 Wire R 1381G1 1381G3 All Black Z 1381G1 1381G1 NOTE: 1. For custom configuration, use APP(R) custom part number configurator at www.andersonpower.com or contact the factory. 2. Arrangement represents front view of the receptacle. H02 POWERPOLE(R) CONTACTS & HOUSINGS FOR H02 INSERT ARRANGEMENT PP180 Contacts Standard Part Number 1328G2-BK 1328G1-BK 1382-BK 1347-BK 1383-BK 1384-BK 1348-BK Minimum & Multiples 100 100 500 500 500 500 200 PP180 Contact Housings Packaged Part Number 1328G2 1328G1 1382 1347 1383 1384 1348 Minimum & Multiples 20 20 10 10 10 10 10 Contact Code Designation 80 81 82 83 84 85 86 Description Individual Individual Individual Individual Individual Individual Individual Wire Size (AWG) 3/0 2/0 1/0 #1 #2 #4 #6 Standard Part Number 1381G1-BK 1381-BK 1381G4-BK 1381G3-BK 1381G2-BK Minimum & Multiples 250 250 250 250 250 Packaged Part Number 1381G1 1381 1381G4 1381G3 1381G2 Minimum & Multiples 10 10 10 10 10 Description Black Blue Green Red White Signal Contacts for Standard & Custom Configurations Standard Part Number PM16P12S30 PM16P1416S30 PM16P1620S30 PM16P2024S30 Minimum & Multiples 500 500 500 500 Packaged Part Number PM16P12S30-50 PM16P1416S30 -50 PM16P1620S30-50 PM16P2024S30-50 Minimum & Multiples 50 50 50 50 Contact Code Designation 87 thru 93 - Description Individual Individual Individual Individual Wire Size (AWG) #12 #14 to 16 #16 to 20 #20 to 24 PM16S12S32 PM16S1416S32 PM16S1620S32 PM16S2024S32 500 500 500 500 PM16S12S32-50 PM16S1416S32-50 PM16S1620S32 -50 PM16S2024S32-50 50 50 50 50 87 thru 93 - Individual Individual Individual Individual #12 #14 to 16 #16 to 20 #20 to 24 NOTE: 1. Contact code designation #87 to 93 is 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole(R) & Multipole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 12. www.andersonpower.com -7- H03 Insert Arrangement Configured with up to 3 PP120 Contacts (up to 190 amps) Standard & Custom Configuration Options POWERPOLE(R) INSERT HOLDER HOUSING ARRANGEMENT 0 Custom Configuration AC Single Phase A 1321G1 R 1321G2 1321G4 DC 1 Circuit, 2 Wire All Black Z E 1321G3 1321G1 1321G1 1321G1 1321G1 H03 1321G1 NOTE: 1. E = Empty 2. For custom configuration, use APP(R) custom part number configurator at www.andersonpower.com or contact the factory. 3. Arrangement represents front view of the receptacle. POWERPOLE(R) CONTACTS & HOUSINGS FOR H03 INSERT ARRANGEMENT PP120 Contact Housings PP120 Contacts Standard Part Number 1323G2-BK 1323G1-BK 1319-BK 1319G4-BK 1319G6-BK Minimum & Multiples 100 100 500 500 500 Packaged Part Number 1323G2 1323G1 1319 1319G4 1319G6 Minimum & Multiples 20 20 20 20 20 Contact Code Designation 20 21 22 23 24 Description Individual Individual Individual Individual Individual Wire Size (AWG) 1/0 #1 #2 #4 #6 Standard Part Number 1321G1-BK 1321-BK 1321G4-BK 1321G3-BK 1321G2-BK Minimum & Multiples 500 500 500 500 500 Packaged Minimum & Part Number Multiples 1321G1 20 1321 20 1321G4 20 1321G3 20 1321G2 20 Signal Contacts for Standard & Custom Configurations Standard Part Number PM16P12S30 PM16P1416S30 PM16P1620S30 PM16P2024S30 Minimum & Multiples 500 500 500 500 Packaged Part Number PM16P12S30-50 PM16P1416S30-50 PM16P1620S30-50 PM16P2024S30-50 Minimum & Multiples 50 50 50 50 Contact Code Designation 25 thru 29 - Description Individual Individual Individual Individual Wire Size (AWG) #12 #14 to 16 #16 to 20 #20 to 24 PM16S12S32 PM16S1416S32 PM16S1620S32 PM16S2024S32 500 500 500 500 PM16S12S32-50 PM16S1416S32-50 PM16S1620S32-50 PM16S2024S32-50 50 50 50 50 25 thru 29 - Individual Individual Individual Individual #12 #14 to 16 #16 to 20 #20 to 24 NOTE: 1. Contact code designation #25 to 29 uses 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole(R) & Mulitpole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 12. -8- www.andersonpower.com Description Black Blue Green Red White H06 Insert Arrangement Configured with up to 6 PP75 Contacts (up to 75 amps) Standard & Custom Configuration Options POWERPOLE(R) INSERT HOLDER HOUSING ARRANGEMENT 0 Custom Configuration B AC 3 Phase, 3 Wire 5916G4 E 5916G7 E AC 3 Phase, 4 Wire E 5916G4 5916G6 F 5916G4 5916 G 5916G5 5916G6 5916 5916G7 5916G5 E AC3 Phase, 5 Wire 5916G5 5916G6 5916G7 5916 H06 DC 2 Circuit, 6 Wire 5916G4 5916G7 5916G4 5916G7 5916G4 5916G7 NOTE: 1. E = Empty 2. For custom configuration, use APP(R) custom part number configurator at www.andersonpower.com or contact the factory. 3. Arrangement represents front view of the receptacle. POWERPOLE(R) CONTACTS & HOUSINGS FOR H06 INSERT ARRANGEMENT PP75 Contacts Standard Part Number 5900-BK 5952-BK 5915-BK Minimum & Multiples 1000 1000 1000 PP75 Contact Housings Packaged Part Number 5900 5952 5915 Minimum & Multiples 25 25 100 Contact Code Designation 11 12 13 Description Individual Individual Individual Wire Size (AWG) #6 #8 #10 to 12 Standard Part Number 5916G4-BK 5916-BK 5916G6-BK 5916G7-BK 5916G5-BK Minimum & Multiples 1000 1000 1000 1000 1000 Packaged Part Number 5916G4 5916 5916G6 5916G7 5916G5 Minimum & Multiples 25 25 25 25 25 Description Black Blue Green Red White Signal Contacts for Standard & Custom Configurations Standard Part Number PM16P12S30 PM16P1416S30 PM16P1620S30 PM16P2024S30 Minimum & Multiples 500 500 500 500 Packaged Part Number PM16P12S30-50 PM16P1416S30-50 PM16P1620S30-50 PM16P2024S30-50 Minimum & Multiples 50 50 50 50 Contact Code Designation 14 thru 16 - Description Individual Individual Individual Individual Wire Size (AWG) #12 #14 to 16 #16 to 20 #20 to 24 PM16S12S32 PM16S1416S32 PM16S1620S32 PM16S2024S32 500 500 500 500 PM16S12S32-50 PM16S1416S32-50 PM16S1620S32-50 PM16S2024S32-50 50 50 50 50 14 thru 16 - Individual Individual Individual Individual #12 #14 to 16 #16 to 20 #20 to 24 NOTE: 1. Contact code designation #14 to 16 uses 4 each of PM16P12S30 (pins) & 4 each of part number PM16S12S32 (sockets) as signal. 2. See Powerpole(R) & Mulitpole Power Connectors Catalog for additional contacts and/or housings options. 3. Application tooling information is available on page 12. www.andersonpower.com -9- Dimensions PLUG Top View Side View [ 3.24 ] 82.3 [ 5.85 ] 148.6 X [ 3.95 ] 100.3 Insert Arrangements Front View - H02 APPROXIMATE OVERALL LENGTH W/ GLAND X MM IN [ 5.85 ] 148.6 Shell with PG 36 Shell with PG 42 Front View - H03 [ 3.24 ] 82.3 193 201 7.6 7.9 Front View - H06 [ 3.24 ] 82.3 [ 3.24 ] 82.3 [ 3.65 ] 92.8 [ 3.96 ] 100.7 [ 3.65 ] 92.8 [ 3.96 ] 100.7 [ 3.65 ] 92.8 [ 3.96 ] 100.7 MATED SIDE VIEW Plug to Panel Mount Receptacle Plug to Inline Receptacle [ 4.47 ] 114.0 X PLUG TO PANEL MOUNT RECEPTACLE X MM IN MM IN 114.0 114.0 X [ 1.7 ] 43.1 MAX PP180 PANEL Shell with PG 36 Shell with PG 36 [ 3.57 ] 90.7 4.7 4.7 200.7 7.90 207.3 8.16 PLUG TO INLINE RECEPTACLE Shell with PG 36 Shell with PG 36 MM 90.7 90.7 IN 3.57 3.57 MM X IN 354.1 13.94 370.3 14.58 PLUG COVER Front View Side View [ 3.65 ] 92.7 [ 4.80 ] 121.88 - 10 - [ 0.150 ] 3.81 [ 1.003 ] 24.48 www.andersonpower.com [ 4.798 ] 121.88 INLINE RECEPTACLE Top View Side View Latch Range [ 0.55 ] 14.0 [ 155.2 ] 6.11 [ 3.57 ] 90.7 APPROXIMATE OVERALL LENGTH W/ GLAND X MM IN [ 6.11 ] 155.2 [ 127.0 ] 5.00 Shell with PG 36 Shell with PG 42 X Insert Arrangements Front View - H02 Front View - H03 200 208 Front View - H06 [ 3.57 ] 90.7 [ 3.57 ] 90.7 [ 3.57 ] 90.7 [ 4.98 ] 126.5 [ 4.98 ] 126.5 7.9 8.2 [ 4.98 ] 126.5 PANEL MOUNT RECEPTACLE Panel Cutout [ 2.94 ] 74.7 Top View CL [ 3.84 ] 97.5 [ 1.7 ] 43.1 MAX PP180 [ 0.22 ] O 5.6 TYP (8) CL [ 1.23 ] R31.2 TYP (2) [ 5.0 ] 127.0 Insert Arrangements Front View - H02 [ 1.80 ] 45.7 Front View - H03 Front View - H06 [ 4.49 ] 114.0 [ 4.49 ] 114.0 [ 4.49 ] 114.0 [ 5.10 ] 129.5 [ 5.10 ] 129.5 [ 4.49 ] 114.0 [ 3.50 ] 88.8 [ 1.80 ] 45.7 [ 0.71 ] 18.0 [ 3.30 ] 83.8 [ 1.50 ] 38.1 Side View Latch Range [ 0.55 ] 14.0 [ 2.94 ] 74.6 [ 5.10 ] 129.5 RECEPTACLE COVER Front View Side View [ 1.09 ] 27.6 REF [ 2.25 ] 57.15 [ 3.96 ] 100.7 [ 1.09 ] 27.6 REF [ 2.25 ] 57.15 [ 3.015 ] 76.58 www.andersonpower.com - 11 - Tooling Charts APPLICATION TOOLING PP180 Contact Tools PP75 Contact Tools Contact Part Number + Hand Tool 5900 Pneumatic or Bench Tool 1309G4 5952 1387G1 5915 + Die + Locator 1388G6 1389G6 1388G7 1388G7 PP120 Contact Tools Contact Part Number Dieless Pneumatic Hydraulic Tool or Bench Tool + 1319G6 1368 1387G1 1323G1 1323G2 1389G4 1388G3 1389G3 1387G2 1387G1 1368 1384 + Locator 1388G4 Pneumatic or Bench Tool 1383 1347 Die Dieless Hydraulic Tool 1382 1348 1328G1 1319 1319G4 Contact Part Number 1387G2 1328G2 + Die + 1303G4 Locator 1304G32 1388G3 1389G3 1388G5 1389G5 1303G4 1303G12 1304G32 PowerMod(R) Signal Contact Tools Contact Part Number Crimp Pins PM16P12S30 PM16P1416S30 PM16P1620S30 PM16P2024S30 APP Hand Tool PM1000G1 Crimp Sockets PM16S12S32 PM16S1416S32 PM16S1620S32 PM16S2024S32 1309 Mil Std.Hand Pneumatic Tool Tool for Locator / or (APP Part #) or Locator / Turret or Turret No Mil Std. (TL0001) M22520/1-01 (TM0001) TP0001 No Mil Std. (TL0002) PM1000G1 TM0001 1387G2 1368 Die NOTE: Visit www.andersonpower.com for additional tooling options. All Data Subject To Change Without Notice Locator Patents with Patents Pending 1387G1 DS-HPSPAK REV00 HEADQUARTERS: Anderson Power Products(R), 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-3700 EUROPE: Anderson Power Products(R) Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203 ASIA / PACIFIC: IDEAL Anderson Asia Pacific Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036 CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218 - 12 - www.andersonpower.com TAIWAN: IDEAL Anderson Asia Pacific Ltd., Taiwan Branch, 4F.-2, No.116, Dadun 20th St., Situn District, Taichung City 407, Taiwan (R.O.C.) T: +(886) 4 2310 6451 F:+(886) 4 2310 6460 www.andersonpower.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Anderson Power Products: 114971G1 114972G1 114972G2 114973P1 3-5965P1 3-5966P1 3-5982P1 3-5982P2 3-5983P1 3-5983P2 35984P1 3-5984P2 3-5986P1 3-5994P2 H1120P41 PL4P42-10X PL6P42-7X PL8P42-7X PS1P36-26X PS1P3632X PS1P42-32X PS1P42-41X PS2P36-13X PS2P36-9X PS3P36-10X PS3P36-7X PS4P36-12X PS5P36-8X SK1-A95H02 SK1-A95H03 SK1-A95H06 SK1-B95H02 SK1-B95H03 SK1-B95H06 SK2-095H02 SK2-095H03 SK2-095H06 SK6-A95H02 SK6-A95H03 SK6-A95H06 SK6-B95H02 SK6-B95H03 SK6-B95H06 SK9-095 SK9P095