www.andersonpower.com - 5 -
PART NUMBER PLAN
Housing
Wire Protection Arrangement Contact
See page 6 For more information see pages 7 thru 9 APP Content
(4 Characters) Dash (1 Character) (2 Characters) Dash (3 Characters)
PS 00 - 0 00 - A01
00 = None 00 = None Custom
PS = Plastic Short 00 - 99 = Various Gland Type Configuration
PM = Plastic Multi-hole Contact Wire Size Available in Insert
Code Contact AWG (mm²) Arrangement
00 Custom Configuration - Use Next Section
11 5900 #6 13.3 H06
12 5952 #8 8.4 H06
13 5915 #10 to 12 5.3 to 3.3 H06
14 5900 with Auxiliary #6 13.3 H06
15 5952 with Auxiliary #8 8.4 H06
16 5915 with Auxiliary #10 to 12 5.3 to 3.3 H06
20 1323G2 1/0 53.5 H03
21 1323G1 #1 42.4 H03
22 1319 #2 33.6 H03
23 1319G4 #4 21.2 H03
24 1319G6 #6 13.3 H03
25 1323G2 with Auxiliary 1/0 53.5 H03
26 1323G1 with Auxiliary #1 42.4 H03
27 1319 with Auxiliary #2 33.6 H03
28 1319G4 with Auxiliary #4 21.2 H03
29 1319G6 with Auxiliary #6 13.3 H03
80 1328G2 3/0 85.0 H02
81 1328G1 2/0 67.4 H02
82 1382 1/0 53.5 H02
83 1347 #1 42.4 H02
84 1383 #2 33.6 H02
85 1384 #4 21.2 H02
86 1348 #6 13.3 H02
87 1328G2 with Auxiliary 3/0 85.0 H02
88 1328G1 with Auxiliary 2/0 67.4 H02
89 1382 with Auxiliary 1/0 53.5 H02
90 1347 with Auxiliary #1 42.4 H02
91 1383 with Auxiliary #2 33.6 H02
92 1384 with Auxiliary #4 21.2 H02
93 1348 with Auxiliary #6 13.3 H02
Insert Arrangement
0 = Custom Configuration -
A = AC Single Phase H03
B = AC 3 Phase, 3 Wire H06
E = AC 3 Phase, 4 wire H06
F = AC 3 phase, 5 wire H06
G = DC 2 Circuit, 6 wire H06
R = DC 1 Circuit, 2 Wire H02, H03
Z = All Black H02, H03
Part Numbering Notes:
1) To order SPEC Pak™ Shell Kits only (no internal Powerpole® housings or contacts), use part numbering on page 4 only. Plug Shell Kit
Example: SK6-A95H02 or SK6-B95H02. Powerpole®
housings, contacts and wire protection may be ordered separately, see pages 6 thru 9 for
information.
2) To order customer configured SPEC Pak™ connectors (including internal Powerpole® housings and contacts) use Part Number Plan across
the top of pages 4 and 5. Customer Configured SPEC Pak™ Plug Connector Example: SK6-A95H03PS04-A22.
3) To order a custom configuration which is not listed on page 7 thru 9, use APP custom part number configurator on the APP® website,
www.andersonpower.com or contact factory.
NOTE: 1. Custom configurations may not be UL Recognized.
2. Contact code designation #14 to 16, #25 to 29 and #87 to 93 use 4 each of part number PM1612S30 (Pins) & 4 each of part number PM16S12S32 (Sockets) as signal.