Additional Resources: Product Page | 3D Model date 02/19/2020 page 1 of 3 SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR FEATURES * locking * metal bushing * strain relief RoHS PART NUMBER KEY SD - X X LP Base Number Pin Options 30 = 3 pins 40 = 4 pins 50 = 5 pins 60 = 6 pins 70 = 7 pins 80 = 8 pins SPECIFICATIONS parameter conditions/description min rated input voltage typ max 100 units Vac rated input current 2 A contact resistance 20 m 1000 Vac 85 C insulation resistance at 500 Vdc voltage withstand at 50/60Hz for 1 minute 100 operating temperature RoHS -40 yes cuidevices.com M Additional Resources: Product Page | 3D Model CUI Devices SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR date 02/19/2020 page 2 of 3 MECHANICAL DRAWINGS units: mm[inches] TOLERANCE: 0.2mm MATERIAL PLATING contact terminals brass silver clip plate cold rolled steel nickel body/nut zinc alloy nickel screw steel nickel body zinc alloy nickel strain relief PVC plastic core nylon 56.8 2.236 36.0 1.417 M16 9.0 0.354 19.0 0.747 13.3 0.524 8.0 0.315 6.0 0.236 SD-30LP SD-40LP 1.45 0.057 (3 PLCS) SD-50LP 1.45 0.057 (5 PLCS) 1.45 0.057 (4 PLCS) 45 72 7.0 0.276 7.0 0.276 SD-60LP 7.0 0.276 SD-70LP 1.45 0.057 (6 PLCS) 60 SD-80LP 1.45 0.057 (7 PLCS) 45 0.7 0.029 1.45 0.057 (8 PLCS) 45 7.0 0.276 7.0 0.276 cuidevices.com 7.0 0.276 Additional Resources: Product Page CUI Devices SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR | 3D Model date 02/19/2020 page 3 of 3 REVISION HISTORY rev. description date 1.0 initial release 02/23/2006 1.01 new template applied 02/07/2012 1.02 updated datasheet 11/24/2015 1.03 updated datasheet 08/25/2017 brand update 02/19/2020 1.04 The revision history provided is for informational purposes only and is believed to be accurate. CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. cuidevices.com