date 02/19/2020
page 1 of 3
SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR
cuidevices.com
FEATURES
• locking
• metal bushing
• strain relief
RoHS
SD - X X LP
Base Number
PART NUMBER KEY
SPECIFICATIONS
parameter conditions/description min typ max units
rated input voltage 100 Vac
rated input current 2 A
contact resistance 20 mΩ
insulation resistance at 500 Vdc 100 MΩ
voltage withstand at 50/60Hz for 1 minute 1000 Vac
operating temperature -40 85 °C
RoHS yes
Pin Options
30 = 3 pins
40 = 4 pins
50 = 5 pins
60 = 6 pins
70 = 7 pins
80 = 8 pins
Additional Resources: Product Page | 3D Model
date 02/19/2020 page 2 of 3
cuidevices.com
CUI Devices SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR
7.00.276
45°
0.70.029
1.45 0.057
(8 PLCS)
7.00.276
45°
1.45 0.057
(7 PLCS)
7.0 0.276
60°
1.45 0.057
(6 PLCS)
7.00.276
45°
1.45 0.057
(5 PLCS)
7.00.276
72°
1.45 0.057
(4 PLCS)
7.00.276
1.45 0.057
(3 PLCS)
8.00.315
56.8 2.236
M16
13.3 0.524
1.41736.0
0.3549.0
0.74719.0
6.00.236
MECHANICAL DRAWINGS
units: mm[inches]
TOLERANCE: ±0.2mm
SD-30LP
SD-60LP
SD-40LP
SD-70LP
SD-50LP
SD-80LP
MATERIAL PLATING
contact terminals brass silver
clip plate cold rolled steel nickel
body/nut zinc alloy nickel
screw steel nickel
body zinc alloy nickel
strain relief PVC
plastic core nylon
Additional Resources: Product Page | 3D Model
CUI Devices SERIES: SD-LP DESCRIPTION: STANDARD DIN CONNECTOR date 02/19/2020 page 3 of 3
cuidevices.com
CUI Devices oers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no
responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any
component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to aect its safety or
eectiveness.
rev. description date
1.0 initial release 02/23/2006
1.01 new template applied 02/07/2012
1.02 updated datasheet 11/24/2015
1.03 updated datasheet 08/25/2017
1.04 brand update 02/19/2020
The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
Additional Resources: Product Page | 3D Model