Embedded Power for Business-Critical Continuity Rev.12.04.07 cxa10 1 of 4 CXA10 Single output Total Power: 10W Input Voltage: 18 - 75VDC # of Outputs: Single Special Features * 4:1 input voltage range * Operating ambient temperature of -40C to +70C in still air * High demonstrated reliability with conservative component deratings * Complies with ETS 300 019-1-3/2-3 * Complies with ETS 300 132-2 input voltage and current requirements * Fully compliant with ETS 300 386-1 * Pin compatible with NFC10 and BXA10 series * Basic insulation system (input to output) * 2 year warranty Safety UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950-1 File No. E132002 VDE Certificate No.112607. File No. 1040100-3336-0136 CB Report and Certificate to IEC60950-1, #DE 1-30686 The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.3 V, 5 V, 12 V, 5 V, 12 V and 15 V. The series has a wide 4:1 input voltage range of 18Vdc to 75 Vdc. The CXA10 has been designed as a competitive open-frame alternative for the communications market. The product is supplied in the industry standard footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection, short-circuit protection and remote ON/OFF. All components are placed in a fully automated environment. Planar magnetics are used in the design to improve the reliability and reduce the profile of the dc-dc converter. The series has full international safety approvals reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications. Embedded Power for Business-Critical Continuity Rev.12.04.07 cxa10 2 of 4 Specifications All specifications are typical at nominal input, full load at 25C unless otherwise stated. OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage accuracy 1.0% Line regulation (LL to HL) Singles/dual positives Dual negatives Load regulation (not incl. cross reg.) Full load to minimum load Min. load All outputs Ripple and noise 20 MHz bandwidth 3.3 V and 5.0 V All others All models 0.1% 0.2% 0.15% 10% 30 mV pk-pk 60 mV pk-pk 12 mV rms Temperature coefficient 0.01%/C Overvoltage protection Clamp type (See table and Notes 3, 4) Short circuit protection Short <20 m Hiccup Transient response Min. load to FL 1.0% Load cross regulation Min. load to FL (See Note 1) 5.0% Continuous auto. recovery INPUT SPECIFICATIONS Input voltage range 48 Vin nominal 18-75 Vdc Input fuse (See Note 10) 1.5 A HRC Max. input rise and fall time 48 V ETS300 132-2 UVLO turn ON voltage UVLO turn OFF voltage (See Note 5) (See Note 5) Remote ON/OFF Logic compatibility ON OFF 5 V/ms 94% 86% (See Note 7) CMOS/TTL/Open Collector Open circuit <1 Vdc ETS 300 386-1 table 5 Conducted emissions Radiated emissions ESD air ESD contact Surge (500 V) Fast transients Radiated immunity Conducted immunity EN55022 (See Note 6) EN55022, external filter, VDE0878, 48 V models See Application Note 100 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3, 4 EN61000-4-4, level 3, 4 EN61000-4-3, level 3 EN61000-4-6, level 3 Level A Level B GENERAL SPECIFICATIONS Efficiency Isolation voltage Switching frequency Approvals and standards (See Notes 7,8,9,10,11) Material flammability Weight MTBF (Representative model 48S05J @ 48 Vin) See table Input/output test voltage 1500 Vdc Fixed 400 kHz EN60950, UL1950 CSA C22.2 No. 950 UL94V-0 12 g (0.42 oz) MIL-HDBK-217F 456,621 hours Parts stress method Ground Benign @ 25 C ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient -40 C to +70 C, temperature See curves Non-operating -55 C to +105 C ETS 300 019-2-3 Classes T3.1 to T3.5 Air temperature Low: IEC 68-2-1 -40 C High: IEC 68-2-2 +70 C Change: IEC 68-2-14 -40C to +70 C Relative humidity IEC 68-2-56 10% to 100% RH IEC 68-2-30 Condensation Vibration, Class 3M5 IEC68-2-6 2-9 Hz, 3 mm disp. 9-200 Hz 1 g MIL-STD-202F Method 204 cond. A Shock, Class 3M5 IEC-68-2-29 Method 213B cond. A MIL-STD-202F Embedded Power for Business-Critical Continuity Rev.12.04.07 cxa10 3 of 4 Specifications Contd. INPUT VOLTAGE OUTPUT VOLTAGE OVERVOLTAGE PROTECTION (3,4) OUTPUT CURRENT (MAX.) (9) TYPICAL EFFICIENCY MODEL NUMBER (7,12,13) 18-75 Vdc 3.3 V 3.9 V 2.4 A 78% CXA10-48S3V3J 18-75 Vdc 5V 6.8 V 2A 81% CXA10-48S05J 18-75 Vdc 12 V 16 V 0.83 A 83% CXA10-48S12J 18-75 Vdc 5 V 6.8 V 1A 81% CXA10-48D05J 18-75 Vdc 12 V 16 V 0.41 A 83% CXA10-48D12J 18-75 Vdc 15 V 19 V 0.33 A 81% CXA10-48D15J Notes 1 2 3 4 5 6 7 8 9 10 11 12 13 Negative output voltage deviation when positive load is changed. Guaranteed minimum output voltage range. TVS spec: See Application Note 100 on our web site. On dual output models, OVP protection is on negative outputs only. With respect to minimum input voltage. With one external ITW Paktron 4.7 F film capacitor across the input. For units with optional remote ON/OFF, please add the suffix `-S' to the model number, e.g. CXA10-48S05-SJ. Additional alphanumeric suffixes maybe added to indicate minor modifications not affecting the safety approvals. Unit provides basic insulation up to the 75 Vdc maximum input voltage. Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for the 3V3 model. User must provide 1.5 A in line fuse in order to comply with safety approvals. Maximum temperature on components Q100, CR101, CR102 not to exceed 120 C. See Application Note 100 for details. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. 0.400 (10.16) 0.100 (2.54) 0.400 (10.16) 0.020 (0.50) O0.040 0.002 Dia. (O1.02 0.05) 3 4 5 0.800 (20.32) 0.020 (0.5) 2.000 (50.80) 1 2 6 0.600 (15.24) 0.400 (10.16) 0.200 (5.08) 0.300 (7.62) 0.394 (10.00) Max. 0.142 (3.60) 0.012 (0.3) OPENFRAME HEIGHT 0.012 (0.3) 0.536 (13.60) 1.000 (25.40) 0.020 (0.5) ALL DIMENSIONS IN INCHES (mm) Tolerance on all dimensions of 0.005 (0.127) Unless otherwise specified PIN CONNECTIONS DERATING CURVE (Output Power %) 100% Output Power (%) 75% PIN NUMBER SINGLE OUTPUT DUAL OUTPUT 1 + Input + Input 2 - Input - Input 6* Remote ON/OFF Remote ON/OFF 3 + Output + Output 4 No Pin Common 5 - Output - Output 50% 25% 27.5% 0% -40C -30C -20C -10C 0C 10C 20C 30C 40C 50C 60C 70C 80C 90C 100C AMBIENT TEMPERATURE (C) Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100 * Optional remote ON/OFF pin. Please add the suffix `-S' to the model number, e.g. CXA10-48S05-SJ (See Note 7). CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. Embedded Power for Business-Critical Continuity Rev.12.04.07 cxa10 4 of 4 Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com technicalsupport@powerconversion.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2007 Emerson Electric Co.